ID |
Date |
Author |
Type |
Category |
Subject |
10403
|
Fri Aug 15 17:24:44 2014 |
Harry | Update | General | Fiber Temp. |
Earlier today Q and I somewhat resurrected my old PER measurement setup so I could run the temperature characterization experiment.
Unfortunately, when I tried to use the fiber illuminator, no light came from the other end, causing me to fail my primary goal for the summer of "don't break anything." The fiber has been re-spooled and labeled appropriately. Also sorry.
In addition to this, Q and I scavenged parts from the telescopes on the PSL and Y End tables, which were either not functional, or needed to have their mode matching adjusted, since we're using the non-PM fibers for FOL, which have a different numerical aperture, and thus slightly different output modes.
Specifically, this is involved removing the rotational mounts, and appropriate beam dumping.
My "calorimeter" still remains intact, in case anyone wants to make this measurement in the future, as this is my last day in the lab.
It's also effective at keeping drinks cold, if you'd rather use it for that. |
10092
|
Tue Jun 24 13:04:49 2014 |
Harry, Manasa | Update | General | Razorblade Beam Analysis Setup |
Harry will update this elog with details about his beam waist measurements for the old NPRO on the SP table. |
10099
|
Wed Jun 25 09:17:33 2014 |
Harry, Manasa | Update | General | Razorblade Beam Analysis Setup |
Quote: |
Harry will update this elog with details about his beam waist measurements for the old NPRO on the SP table.
|
see http://nodus.ligo.caltech.edu:8080/40m/10098 for the update |
2708
|
Wed Mar 24 12:38:17 2010 |
Hartmut | Configuration | Green Locking | Broadband PD for green PLL |
Modified one of the PD assemblies carrying a large SI-Diode (~10mm diameter).
Removed elements used for resonant operation and changed PD readout to transimpedance
configuration. The opamp is a CLC409 with 240 Ohm feedback (i.e. transimpedance) resistor.
To prevent noise peaking at very high frequencies and get some decoupling of the PD,
I added a small series resistor in line with the PD and the inverting opamp input.
It was chosen as 13 Ohm, and still allows for operation up to ~100MHz.
Perhaps it could be smaller, but much more bandwith seems not possible with this opamp anyway.
Changes are marked in the schematic, and I list affected components here.
(Numbers refer to version 'PD327.SCH' from 30-April-1997):
-removed L4
-connected L3 (now open pad) via 100 Ohm to RF opamp output. This restores the DC sognal output.
-removed c17
-connected pin 3 of opamp via 25 Ohm to GND
-connected kathode of PD via 13 Ohm to pin 2 of opamp
-removed L6, C26, L5, C18, and C27
-shorted C27 pad to get signal to the RF output
Measured the optical TF with the test laser setup.
(Note that this is at 1064nm, although the PD is meant to work with green light at 532nm!)
Essentially it looks usable out to 100MHz, where the gain dropped only by about
6dB compared to 10MHz.
Beyond 100MHz the TF falls pretty steeply then, probably dominated by the opamp.
The maximal bias used is -150V.
If the bias is 'reduced' from -150V to -50V, the response goes down by 4dB at 10MHz and
by 9dB at 100MHz.
The average output was 30mV at the RF output, corresponding to 60mV at the opamp output (50Ohm divider chain).
With 240 Ohm transimpedance this yields 250µA photo-current used for these transfer functions.


|
2745
|
Wed Mar 31 19:29:58 2010 |
Hartmut | Update | Electronics | (1cm-) Si PD transfer functions update |
Recorded transfer functions for the 1cm Si-PD as described on p. 2708
for different biases. I put the plots in there, to keep the info in one place,
where the label on the PD case (which Steve made without asking him) points
to.
I talked to some people recently about the fact that the responsivity (A/W) of the PD
changes even at DC for different biases. I tested this again and should be more precise about this:
The first time I observed this was in the transfer functions as shown on p. 2708.
With 'DC' I meant 'low frequency' there, as you can still see an effect of the bias as low as 100kHz.
Then at one point I saw the responsivity changing with bias also at true DC.
However, it turned out that this is only the case if the photocurrent is too high.
If the photocurrent is 4mA, you need 400mV bias to get the max. responsivity.
For 2mA photocurrent, the responsivity is already maximal for 0V bias.
An effect for relative low frequencies remains however.
The DC check of responsivity was done with white light from a bulb.
|
2752
|
Thu Apr 1 16:34:29 2010 |
Hartmut | Update | Green Locking | Silicon PDs |
just a few infos on Silicon PDs I looked up.
If you want to go beyond the 100MHz achievable with the device I worked on,
the one thing to improve is the opamp, where Steve is trying to find OPA657.
This is a FET with 1.6GHz BWP, minimum stable gain of 7, and 4.8nV/rt(Hz) noise.
Should be ok with 750-1000 Ohm transimpedance.
The other thing you might want to change is the PD
(although it might be the 1cm PD with high bias is as fast as smaller ones with lower bias).
There are two types of other Si diodes at the 40m right now (~3mm):
-Rana and I found a Centronic OSD 15-5T in the old equipment
-Frank gave me a Hamamatsu S1223-01 on a Thorlabs pre-amp device (could be taken out).
The Centronic OSD 15-5T has up to 80pF with 12 V bias according to the datasheet.
The Hamamatsu S1223-01 is stated with 20pF only, but stated to have a max. frequency resp. of 20MHz ('-3db point').
I dont know what this means, as the corner freq. of 10pF into 50Ohm is still 160MHz.
In any case there are faster 3mm types to start with, as for example Hamamatsu S3399 (~ 90$),
which is stated to have the corner at 100MHz with 50 Ohm load.
For this type the stated capacity (20pF) looks consistent with ~100MHz corner into 50 Ohm.
So probably you can get higher BW with this one using much smaller load, as in transimpedance stage.
|
2757
|
Thu Apr 1 20:29:02 2010 |
Hartmut | Update | Green Locking | simple PD test circuit |
I made a simple PD test circuit which may allow to test PD response up to few 100MHz.
Its not for low noise, only for characterising PD response.
Here is the circuit:
The 2 capacitor values (for bypassing) are kind of arbitrary, just what I found around
(one medium, one small capacity). Could be improved by better RF types (e.g. Mica).
The PD type has no meaning. I put in the Centronic 15-T5 for a start.
The bias can be up to 20V for this diode.
The signal appears across R1. It is small, to make a large bandwidth.
R2 is just for slightly decoupling the signal from the following RF amplifier.
The wire into the RF amplifier is short (~cm). And the amplifier is supposed to have 50 Ohm
input impedance.
I use a mini circuits ZFL 500 here.
power supply for this is 15V.

|
16654
|
Wed Feb 9 14:34:27 2022 |
Ian | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
Restarted the C1sim machine at about 12:30 to help diagnose a network problem. Everything is back up and running |
Attachment 1: SummaryMdemScreen.png
|
|
16021
|
Tue Apr 13 16:24:38 2021 |
Ian MacMillan | Update | CDS | 40m LSC simPlant model |
Added Matlab to the Docker machine. This should help immensely with workflow as well as keeping installed libraries consistent. Next step is outlining the project so coding is easier
Command to launch is: $ matlab &
From Jon just for bookkeeping:
Then in the Matlab command window, open the CDS parts library via:
addpath /home/controls/simLink/lib/
open /home/controls/simLink/CDS_PARTS.mdl
Then open an RTCDS model (for example, here the LSC plant) via:
open /home/controls/docker-cymac/userapps/x1lsp.mdl
|
16050
|
Mon Apr 19 13:15:20 2021 |
Ian MacMillan | Update | CDS | 40m LSC simPlant model |
The x1SUSsim model on the docker was made in a more recent version of Simulink so I updated Matlab (see this)
I updated Matlab to 2021a so now the docker has 2020b and 2021a installed. This should also install Simulink 10.3 for the sus model to open. I used my account to activate it but I can change it over if I get a dedicated license for this. I am not sure what Jon did for the 2020b that he installed.
it is giving me "License error: -9,57" so I guess it didn't work... I will try to just make the model on the 2020b just so I have something.
-----------------------------------------------------------------------------------------------------------------------------
I was able to fix the problem with the activation (using this).
I can now open the x1sussim.mdl file. It is trying to access a BSFM_MASTER Library that it doesn't seem to have. the other files don't seem to have any warnings though.
the simple suspension model can be found in home/controls/docker-cymac/userapps/c1simpsus.mdl on the docker system. This is where I will put my model. (right now it is just a copied file)
Also using Simulink on the docker is very slow. I think this is either a limit of the x2goclient software or the hardware that the docker is running on. |
16059
|
Wed Apr 21 10:03:01 2021 |
Ian MacMillan | Update | CDS | 40m LSC simPlant model |
So I am stuck on how to add the control block to my model. I am trying to make it as simple as possible with just a simple transfer function for a damped harmonic oscillator and then the control block (see overview.png).
The transfer function I am using is:

For future generations: To measure the transfer function (to verify that it is doing what it says it is) I am using the discrete transfer function estimator block. To get a quick transfer function estimator Simulink program run ex_discrete_transfer_function_estimator in the Matlab command line. This works well for filters but it was hit or miss using the discrete transfer function.
The roadblock I am running into right now is that I can't figure out how to add the controller to the model. Not on an interpretation level but in a very straightforward "can I drag it into my model and will it just work" kind of way.
I am also a little confused as to exactly which block would do the controlling. Because I want to just use the x of the pendulum (its position) I think I want to use the suspension controls which come are connected to in the suspension plant model. But where exactly is it and how can I get the model? I can't seem to find it. |
Attachment 1: Overview.png
|
|
16081
|
Fri Apr 23 15:52:19 2021 |
Ian MacMillan | Update | CDS | 40m LSC simPlant model |
I have attached the framework that I am using for the full system. Plantframework.pdf has the important aspects that I will be changed. Right now I am trying to keep it mostly as is, but I have disconnected the Optic Force Noise and hope to disconnect the Suspension Position Noise. The Optic Force Noise Block is additive to the signal so eliminating it from the system should make it less realistic but simpler. It can be added back easily by reconnecting it.
The next step is adding my plant response, which is simply the transfer function and measurement from the last post. These should be inserted in the place of the red TM_RESP in the model.
The TM_RESP block takes in a vector of dimension 12 and returns a vector of dimension 6. The confusing part is that the block does not seem to do anything. it simply passes the vector through with no changes. I'm not sure why this is the case and I am looking for documentation to explain it but haven't found anything. As to how a 12 vector turns into a 6 vector I am also lost. I will probably just disconnect everything but the x position.
I tried to just throw in my model (see Simple_Plant.pdf) and see what happened but the model would not let me add built-in blocks to the model. This is weird because all the blocks that I am adding are part of the basic library. My guess is that this mode will only accept blocks from the CDL library. I will either need to change my blocks to be made from blocks in the CDL library or maybe I can pass the signal out of the plant framework model then into my model then back to the plant framework model. I think this is just a Matlab thing that I don't know about yet. (Jon probably knows)
I have also attached an image of the controls model for reference. It looks like a mess but I'm sure there is a method. I won't get lost in going through it just assume it works... for now.
The next question I have been asking is how do I show that the system works. When anchal and I made a python simulation of the system, we tested it by seeing the evolution of the degrees of freedom over time given some initial conditions. We could see the pendulum propagating and some of the coupling between the DOFs. This is a fast and dirty way to check if everything is working and should be easy to add. I simply recorded the POS signal and graph it over time. Once we get to a state-space model we can test it by taking the transfer function, but since our plant is literally already just a transfer function there isn't much of a point yet.
Also, I need to add color to my Simple_Plant.pdf model because it looks really boring :( |
Attachment 1: Plant_framework.pdf
|
|
Attachment 2: Simple_Plant.pdf
|
|
Attachment 3: Controls.pdf
|
|
16088
|
Tue Apr 27 15:15:17 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
The first version of the single filter plant is below. Jon and I went through compiling a model and running it on the docker (see this post)
We activated an early version of the plant model (from about 10 years ago) but this model was not designed to run on its own so we had to ground lots of unconnected pieces. the model compiled and ran so we moved on to the x1sus_single_plant model that I prepared.
This model is shown in the first attachment wasn't made to be run alone because it is technically a locked library (see the lock in the bottom left). It is supposed to be referenced by another file: x1sup.mdl (see the second attachment). This works great in the Simulink framework. I add the x1sus_single_plant model to the path and Matlab automatically attaches the two. but the docker does not seem to be able to combine the two. Starting the cymac it gives these errors:
cymac | Can't find sus_single_plant.mdl; RCG_LIB_PATH=/opt/rtcds/userapps:/opt/rtcds/userapps/lib:/usr/share/advligorts/src/src/epics/simLink/:/usr/share/advligorts/src/src/epics/simLink/lib:/usr/share/advligorts/src/src/epics/simLink
cymac | make[1]: *** [Makefile:30: x1sup] Error 2
cymac | make: *** [Makefile:35: x1sup] Error 1
I have tried putting the x1sus_single_plant.mdl file everywhere as well as physically dragging the blocks that I need into the x1sup.mdl file but it always seems to throw an error. Basically, I want to combine them into one file that is not referencing anything other than the CDS library but I cant figure out how to combine them.
Okay but the next problem is the medm screen generation. When we had the original 2010 model running the sitemap did not include it. It included models that weren't even running before but not the model Jon and I had added. I think this is because the other models that were not running had medm screens made for them. I need to figure out how to generate those screens. I need to figure out how to use the tool Chris made to auto-generate medm screens from Simulink but I can't seem to figure it out. And honestly, it won't be much use to me until I can actually connect the plant block to its framework. One option is to just copy each piece over one by one. this will take forever but at this point, I am frustrated enough to try it. I'll try to give another update later tonight. |
Attachment 1: x1sus_single_plant.pdf
|
|
Attachment 2: x1sup.pdf
|
|
16096
|
Thu Apr 29 13:41:40 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
To add the required library: put the .mdl file that contains the library into the userapps/lib folder. That will allow it to compile correctly
I got these errors:
Module ‘mbuf’ symvers file could not be found.
Module ‘gpstime’ symvers file could not be found.
***ERROR: IPCx parameter file /opt/rtcds/zzz/c1/chans/ipc/c1.ipc not found
make[1]: *** [Makefile:30: c1sup] Error 2
make: *** [Makefile:35: c1sup] Error 1
I removed all IPC parts (as seen in Attachment 1) and that did the trick. IPC parts (Inter-Process Communication) were how this model was linked to the controller so I don't know how exactly how I can link them now.
I also went through the model and grounded all un-attached inputs and outputs. Now the model compiles
Also, The computer seems to be running very slowly in the past 24 hours. I know Jon was working on it so I'm wondering if that had any impact. I think it has to do with the connection speed because I am connected through X2goclient. And one thing that has probably been said before but I want to note again is that you don't need a campus VPN to access the docker. |
Attachment 1: Non-IPC_Plant.pdf
|
|
16106
|
Fri Apr 30 12:52:14 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
Now that the model is finally compiled I need to make an medm screen for it and put it in the c1sim:/home/controls/docker-cymac/userapps/medm/ directory.
But before doing that I really want to test it using the autogenerated medm screens which are in the virtual cymac in the folder /opt/rtcds/tst/x1/medm/x1sup . In Jon's post he said that I can use the virtual path for sitemap after running $ eval $(./env_cymac) |
16109
|
Mon May 3 13:35:12 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
When the cymac is started it gives me a list of channels shown below.
$ Initialized TP interface node=8, host=98e93ecffcca
$ Creating X1:DAQ-DC0_X1IOP_STATUS
$ Creating X1:DAQ-DC0_X1IOP_CRC_CPS
$ Creating X1:DAQ-DC0_X1IOP_CRC_SUM
$ Creating X1:DAQ-DC0_X1SUP_STATUS
$ Creating X1:DAQ-DC0_X1SUP_CRC_CPS
$ Creating X1:DAQ-DC0_X1SUP_CRC_SUM
But when I enter it into the Diaggui I get an error:
The following channel could not be found:
X1:DAQ-DC0_X1SUP_CRC_CPS
My guess is that need to connect to the Diaggui to something that can access those channels. I also need to figure out what those channels are. |
16118
|
Tue May 4 14:55:38 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
After a helpful meeting with Jon, we realized that I have somehow corrupted the sitemap file. So I am going to use the code Chris wrote to regenerate it.
Also, I am going to connect the controller using the IPC parts. The error that I was having before had to do with the IPC parts not being connected properly. |
16122
|
Wed May 5 15:11:54 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
I added the IPC parts back to the plant model so that should be done now. It looks like this again here.
I can't seem to find the control model which should look like this. When I open sus_single_control.mdl , it just shows the C1_SUS_SINGLE_PLANT.mdl model. Which should not be the case. |
16124
|
Thu May 6 16:13:24 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
When using mdl2adl I was getting the error:
$ cd /home/controls/mdl2adl
$ ./mdl2adl x1sup.mdl
error: set $site and $ifo environment variables
to set these in the terminal use the following commands:
$ export site=tst
$ export ifo=x1
On most of the systems, there is a script that automatically runs when a terminal is opened that sets these but that hasn't been added here so you must run these commands every time you open the terminal when you are using mdl2adl. |
16126
|
Fri May 7 11:19:29 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
I copied c1scx.mdl to the docker to attach to the plant using the commands:
$ ssh nodus.ligo.caltech.edu
[Enter Password]
$ cd opt/rtcds/userapps/release/isc/c1/models/simPlant
$ scp c1scx.mdl controls@c1sim:/home/controls/docker-cymac/userapps
|
16134
|
Wed May 12 13:06:15 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
Working with Chris, we decided that it is probably better to use a simple filter module as a controller before we make the model more complicated. I will use the plant model that I have already made (see attachment 1 of this). then attach a single control filter module to that: as seen in attachment 1. because I only want to work with one degree of freedom (position) I will average the four outputs which should give me the position. Then by feeding the same signal to all four inputs I should isolate one degree of freedom while still using the premade plant model.
The model I made that is shown in attachment 2 is the model I made from the plan. And it complies! yay! I think there is a better way to do the average than the way I showed. And since the model is feeding back on itself I think I need to add a delay which Rana noted a while ago. I think it was a UnitDelay (see page 41 of RTS Developer’s Guide). So I will add that if we run into problems but I think there is enough going on that it might already be delayed.
Since our model (x1sup_isolated.mdl) has compiled we can open the medm screens for it. I provide a procedure below which is based on Jon's post.
[First start the cymac and have the model running]
$ cd docker-cymac
$ eval $(./env_cymac)
$ medm -x /opt/rtcds/tst/x1/medm/x1sup_isolated/X1SUP_ISOLATED_GDS_TP.adl
To see a list of all medm screens use:
$ cd docker-cymac
$ ./login_cymac
# cd /opt/rtcds/tst/x1/medm/x1sup_isolated
# ls
Some of the other useful ones are:
adl screen |
Description |
X1SUP_ISOLATED_Control_Module.adl |
This is the control filter module shown in attachment 2 at the top in the center. This module will represent the control system. |
X1SUP_ISOLATED_C1_SUS_SINGLE_PLANT_Plant_POS_Mod.adl |
See attachment 4. This screen shows the POS plant filter module that will be filled by the filter representing the transfer function of a damped harmonic oscillator: 
THIS TF HAS BEEN UPDATED SEE NEXT POST
|
The first one of these screens that are of interest to us (shown in attachment 3) is the X1SUP_ISOLATED_GDS_TP.adl screen, which is the CDS runtime diagnostics screen. This screen tells us "the success/fail state of the model and all its dependencies." I am still figuring out these screens and the best guide is T1100625.
The next step is taking some data and seeing if I can see the position damp over time. To do this I need to:
- Edit the plant filter for the model and add the correct filter.
- Figure out a filter for the control system and add it to that. (I can leave it as is to see what the plant is doing)
- Take some position data to show that the plant is a harmonic oscillator and is damping away.
|
Attachment 1: SimplePlant_SingleContr.pdf
|
|
Attachment 2: x1sup_isolated.pdf
|
|
Attachment 3: X1SUP_ISOLATED_GDS_TP.png
|
|
Attachment 4: X1SUP_ISOLATED_C1_SUS_SINGLE_PLANT_Plant_POS_Mod.png
|
|
16151
|
Fri May 21 09:44:52 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
The transfer function given in the previous post was slightly incorrect the units did not make sense the new function is:

I have attached a quick derivation below in attachment 1 |
Attachment 1: Transfer_Function_of_Damped_Harmonic_Oscillator.pdf
|
|
16153
|
Fri May 21 14:36:20 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
The plant transfer function of the pendulum in the s domain is:

Using Foton to make a plot of the TF needed and using m=40kg, w0=3Hz, and Q=50 (See attachment 1). It is easiest to enter the above filter using RPoly and saved it as Plant_V1 |
Attachment 1: Plant_Mod_TF.pdf
|
|
16177
|
Thu Jun 3 13:06:47 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
I was able to measure the transfer function of the plant filter module from the channel X1:SUP-C1_SUS_SINGLE_PLANT_Plant_POS_Mod_EXC to X1:SUP-C1_SUS_SINGLE_PLANT_Plant_POS_Mod_OUT . The resulting transfer function is shown below. I have also attached the raw data for making the graph.
Next, I will make a script that will make the photon filters for all the degrees of freedom and start working on the matrix version of the filter module so that there can be multiple degrees of freedom. |
Attachment 1: SingleSusPlantTF.pdf
|
|
Attachment 2: SUS_PLANT_TF.zip
|
16191
|
Mon Jun 7 17:49:19 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
Added difference to the graph. I included the code so that others could see what it looks like and use it for easy use. |
Attachment 1: SingleSusPlantTF.pdf
|
|
Attachment 2: TF_Graph_Code.zip
|
16195
|
Wed Jun 9 13:50:48 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
I have attached an updated transfer function graph with the residual easier to see. I thought here I would include a better explanation of what this transfer function was measuring.
This transfer function was mainly about learning how to use DTT and Foton to make and measure transfer functions. Therefore it is just measuring across a single CDS filter block. X1SUP_ISOLATED_C1_SUS_SINGLE_PLANT_Plant_POS_Mod block to be specific. This measurement shows that the block is doing what I programmed it to do with Foton. The residual is probably just because the measured TF had fewer points than the calculated one.
The next step is to take a closed-loop TF of the system and the control module.
After that, I want to add more degrees of freedom to the model. both in the plant and in the controls. |
Attachment 1: SingleSusPlantTF.pdf
|
|
16201
|
Tue Jun 15 11:46:40 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
I have added more degrees of freedom. The model includes x, y, z, pitch, yaw, roll and is controlled by a matrix of transfer functions (See Attachment 2). I have added 5 control filters to individually control UL, UR, LL, LR, and side. Eventually, this should become a matrix too but for the moment this is fine.
Note the Unit delay blocks in the control in Attachment 1. The model will not compile without these blocks. |
Attachment 1: x1sup_isolated-6-15-v1.pdf
|
|
Attachment 2: C1_SUS_SINGLE_PLANT-6-15-v1.pdf
|
|
16208
|
Thu Jun 17 11:19:37 2021 |
Ian MacMillan | Update | CDS | CDS Upgrade |
Jon and I tested the ADC and DAC cards in both of the systems on the test stand. We had to swap out an 18-bit DAC for a 16-bit one that worked but now both machines have at least one working ADC and DAC.
[Still working on this post. I need to look at what is in the machines to say everything ] |
16217
|
Mon Jun 21 17:15:49 2021 |
Ian MacMillan | Update | CDS | CDS Upgrade |
Anchal and I wrote a script (Attachment 1) that will test the ADC and DAC connections with inputs on the INMON from -3000 to 3000. We could not run it because some of the channels seemed to be frozen. |
Attachment 1: DAC2ADC_Test.py
|
import os
import time
import numpy as np
import subprocess
from traceback import print_exc
import argparse
def grabInputArgs():
parser = argparse.ArgumentParser(
... 75 more lines ...
|
16220
|
Tue Jun 22 16:53:01 2021 |
Ian MacMillan | Update | CDS | Front-End Assembly and Testing |
The channels on both the C1BHD and C1SUS2 seem to be frozen: they arent updating and are holding one value. To fix this Anchal and I tried:
- restarting the computers
- restarting basically everything including the models
- Changing the matrix values
- adding filters
- messing with the offset
- restarting the network ports (Paco suggested this apparently it worked for him at some point)
- Checking to make sure everything was still connected inside the case (DAC, ADC, etc..)
I wonder if Jon has any ideas. |
16224
|
Thu Jun 24 17:32:52 2021 |
Ian MacMillan | Update | CDS | Front-End Assembly and Testing |
Anchal and I ran tests on the two systems (C1-SUS2 and C1-BHD). Attached are the results and the code and data to recreate them.
We connected one DAC channel to one ADC channel and thus all of the results represent a DAC/ADC pair. We then set the offset to different values from -3000 to 3000 and recorded the measured signal. I then plotted the response curve of every DAC/ADC pair so each was tested at least once.
There are two types of plots included in the attachments
1) a summary plot found on the last pages of the pdf files. This is a quick and dirty way to see if all of the channels are working. It is NOT a replacement for the other plots. It shows all the data quickly but sacrifices precision.
2) In an in-depth look at an ADC/DAC pair. Here I show the measured value for a defined DC offset. The Gain of the system should be 0.5 (put in an offset of 100 and measure 50). I included a line to show where this should be. I also plotted the difference between the 0.5 gain line and the measured data.
As seen in the provided plots the channels get saturated after about the -2000 to 2000 mark, which is why the difference graph is only concentrated on -2000 to 2000 range.
Summary: all the channels look to be working they all report very little deviation off of the theoretical gain.
Note: ADC channel 31 is the timing signal so it is the only channel that is wildly off. It is not a measurement channel and we just measured it by mistake. |
Attachment 1: C1-SU2_Channel_Responses.pdf
|
|
Attachment 2: C1-BHD_Channel_Responses.pdf
|
|
Attachment 3: CDS_Channel_Test.zip
|
16230
|
Wed Jun 30 14:09:26 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
I have looked at my code from the previous plot of the transfer function and realized that there is a slight error that must be fixed before we can analyze the difference between the theoretical transfer function and the measured transfer function.
The theoretical transfer function, which was generated from Photon has approximately 1000 data points while the measured one has about 120. There are no points between the two datasets that have the same frequency values, so they are not directly comparable. In order to compare them I must infer the data between the points. In the previous post [16195] I expanded the measured dataset. In other words: I filled in the space between points linearly so that I could compare the two data sets. Using this code:
#make values for the comparison
tck_mag = splrep(tst_f, tst_mag) # get bspline representation given (x,y) values
gen_mag = splev(sim_f, tck_mag) # generate intermediate values
dif_mag=[]
for x in range(len(gen_mag)):
dif_mag.append(gen_mag[x]-sim_mag[x]) # measured minus predicted
tck_ph = splrep(tst_f, tst_ph) # get bspline representation given (x,y) values
gen_ph = splev(sim_f, tck_ph) # generate intermediate values
dif_ph=[]
for x in range(len(gen_ph)):
dif_ph.append(gen_ph[x]-sim_ph[x])
At points like a sharp peak where the measured data set was sparse compared to the peak, the difference would see the difference between the intermediate “measured” values and the theoretical ones, which would make the difference much higher than it really was.
To fix this I changed the code to generate the intermediate values for the theoretical data set. Using the code here:
tck_mag = splrep(sim_f, sim_mag) # get bspline representation given (x,y) values
gen_mag = splev(tst_f, tck_mag) # generate intermediate values
dif_mag=[]
for x in range(len(tst_mag)):
dif_mag.append(tst_mag[x]-gen_mag[x])#measured minus predicted
tck_ph = splrep(sim_f, sim_ph) # get bspline representation given (x,y) values
gen_ph = splev(tst_f, tck_ph) # generate intermediate values
dif_ph=[]
for x in range(len(tst_ph)):
dif_ph.append(tst_ph[x]-gen_ph[x])
Because this dataset has far more values (about 10 times more) the previous problem is not such an issue. In addition, there is never an inferred measured value used. That makes it more representative of the true accuracy of the real transfer function.
This is an update to a previous plot, so I am still using the same data just changing the way it is coded. This plot/data does not have a Q of 1000. That plot will be in a later post along with the error estimation that we talked about in this week’s meeting.
The new plot is shown below in attachment 1. Data and code are contained in attachment 2 |
Attachment 1: SingleSusPlantTF.pdf
|
|
Attachment 2: Plant_TF_Test.zip
|
16289
|
Mon Aug 23 15:25:59 2021 |
Ian MacMillan | Update | CDS | SUS simPlant model |
I am adding a State-space block to the SimPlant cds model using the example Chris gave. I made a new folder in controls called SimPlantStateSpace. wI used the code below to make a state-space LTI model with a 1D pendulum then I converted it to a discrete system using c2d matlab function. Then I used these in the rtss.m file to create the state space code I need in the SimPlantStateSpace_1D_model.h file.
%sys_model.m
Q = 1000;
phi = 1/Q;
g = 9.806;
m = 0.24; % mass of pendulum
l = 0.248; %length of pendulum
w_0 = sqrt(g/l);
f=16000 %this is the frequency of the channel that will be used
A = [0 1; -w_0^2*(1+1/Q*1i) -w_0/Q]
B = [0; 1/m];
C = [1 0];
D = [0];
sys_dc = ss(A,B,C,D)
sys=c2d(sys_dc, 1/f)
This code outputs the discrete state space that is added to the header file attached. |
Attachment 1: SimPlantStateSpace.zip
|
16339
|
Thu Sep 16 14:08:14 2021 |
Ian MacMillan | Frogs | | Tour |
I gave some of the data analysts a look around because they asked and nothing was currently going on in the 40m. Nothing was changed. |
16348
|
Mon Sep 20 15:42:44 2021 |
Ian MacMillan | Summary | Computers | Quantization Code Summary |
This post serves as a summary and description of code to run to test the impacts of quantization noise on a state-space implementation of the suspension model.
Purpose: We want to use a state-space model in our suspension plant code. Before we can do this we want to test to see if the state-space model is prone to problems with quantization noise. We will compare two models one for a standard direct-ii filter and one with a state-space model and then compare the noise from both.
Signal Generation:
First I built a basic signal generator that can produce a sine wave for a specified amount of time then can produce a zero signal for a specified amount of time. This will let the model ring up with the sine wave then decay away with the zero signal. This input signal is generated at a sample rate of 2^16 samples per second then stored in a numpy array. I later feed this back into both models and record their results.
State-space Model:
The code can be seen here
The state-space model takes in the list of excitation values and feeds them through a loop that calculates the next value in the output.
Given that the state-space model follows the form
and ,
the model has three parts the first equation, an integration, and the second equation.
- The first equation takes the input x and the excitation u and generates the x dot vector shown on the left-hand side of the first state-space equation.
- The second part must integrate x to obtain the x that is found in the next equation. This uses the velocity and acceleration to integrate to the next x that will be plugged into the second equation
- The second equation in the state space representation takes the x vector we just calculated and then multiplies it with the sensing matrix C. we don't have a D matrix so this gives us the next output in our system
This system is the coded form of the block diagram of the state space representation shown in attachment 1
Direct-II Model:
The direct form 2 filter works in a much simpler way. because it involves no integration and follows the block diagram shown in Attachment 2, we can use a single difference equation to find the next output. However, the only complication that comes into play is that we also have to keep track of the w(n) seen in the middle of the block diagram. We use these two equations to calculate the output value
, where w[n] is ![\omega[n]=x[n] - a_1 \omega [n-1] -a_2 \omega[n-2]](https://latex.codecogs.com/gif.latex?%5Comega%5Bn%5D%3Dx%5Bn%5D%20-%20a_1%20%5Comega%20%5Bn-1%5D%20-a_2%20%5Comega%5Bn-2%5D)
Bit length Control:
To control the bit length of each of the models I typecast all the inputs using np.float then the bit length that I want. This simulates the computer using only a specified bit length. I have to go through the code and force the code to use 128 bit by default. Currently, the default is 64 bit which so at the moment I am limited to 64 bit for highest bit length. I also need to go in and examine how numpy truncates floats to make sure it isn't doing anything unexpected.
Bode Plot:
The bode plot at the bottom shows the transfer function for both the IIR model and the state-space model. I generated about 100 seconds of white noise then computed the transfer function as

which is the cross-spectral density divided by the power spectral density. We can see that they match pretty closely at 64 bits. The IIR direct II model seems to have more noise on the surface but we are going to examine that in the next elog
|
Attachment 1: 472px-Typical_State_Space_model.svg.png
|
|
Attachment 2: Biquad_filter_DF-IIx.svg.png
|
|
Attachment 3: SS-IIR-TF.pdf
|
|
16355
|
Wed Sep 22 14:22:35 2021 |
Ian MacMillan | Summary | Computers | Quantization Noise Calculation Summary |
Now that we have a model of how the SS and IIR filters work we can get to the problem of how to measure the quantization noise in each of the systems. Den Martynov's thesis talks a little about this. from my understanding: He measured quantization noise by having two filters using two types of variables with different numbers of bits. He had one filter with many more bits than the second one. He fed the same input signal to both filters then recorded their outputs x_1 and x_2, where x_2 had the higher number of bits. He then took the difference x_1-x_2. Since the CDS system uses double format, he assumes that quantization noise scales with mantissa length. He can therefore extrapolate the quantization noise for any mantissa length.
Here is the Code that follows the following procedure (as of today at least)
This problem is a little harder than I had originally thought. I took Rana's advice and asked Aaron about how he had tackled a similar problem. We came up with a procedure explained below (though any mistakes are my own):
- Feed different white noise data into three of the same filter this should yield the following equation:
, where is the power spectrum of the output for the ith filter, is the noise filtered through an "ideal" filter with no quantization noise, and is the power spectrum of the quantization noise. Since we are feeding random noise into the input the power of the quantization noise should be the same for all three of our runs.
- Next, we have our three outputs:
, , and that follow the equations:



From these three equations, we calculate the three quantities: , , and which are calculated by:



from these quantities, we can calculate three values: , , and since these are just estimates we are using a bar on top. These are calculated using:



using these estimates we can then estimate using the formula:

we can average the three estimates for to come up with one estimate.
This procedure should be able to give us a good estimate of the quantization noise. However, in the graph shown in the attachments below show that the noise follows the transfer function of the model to begin with. I would not expect this to be true so I believe that there is an error in the above procedure or in my code that I am working on finding. I may have to rework this three-corner hat approach. I may have a mistake in my code that I will have to go through.
I would expect the quantization noise to be flatter and not follow the shape of the transfer function of the model. Instead, we have what looks like just the result of random noise being filtered through the model.
Next steps:
The first real step is being able to quantify the quantization noise but after I fix the issues in my code I will be able to start liking at optimal model design for both the state-space model and the direct form II model. I have been looking through the book "Quantization noise" by Bernard Widrow and Istvan Kollar which offers some good insights on how to minimize quantization noise. |
Attachment 1: IIR64-bitnoisespectrum.pdf
|
|
16360
|
Mon Sep 27 12:12:15 2021 |
Ian MacMillan | Summary | Computers | Quantization Noise Calculation Summary |
I have not been able to figure out a way to make the system that Aaron and I talked about. I'm not even sure it is possible to pull the information out of the information I have in this way. Even the book uses a comparison to a high precision filter as a way to calculate the quantization noise:
"Quantization noise in digital filters can be studied in simulation by comparing the behavior of the actual quantized digital filter with that of a refrence digital filter having the same structure but whose numerical calculations are done extremely accurately."
-Quantization Noise by Bernard Widrow and Istvan Kollar (pg. 416)
Thus I will use a technique closer to that used in Den Martynov's thesis (see appendix B starting on page 171). A summary of my understanding of his method is given here:
A filter is given raw unfiltered gaussian data then it is filtered and the result is the filtered data thus we get the result: where is the raw noise filtered through an ideal filter and is the difference which in this case is the quantization noise. Thus I will input about 100-1000 seconds of the same white noise into a 32-bit and a 64-bit filter. (hopefully, I can increase the more precise one to 128 bit in the future) then I record their outputs and subtract the from each other. this should give us the Quantization error :

and since because they are both running through ideal filters:


and since in this case, we are assuming that the higher bit-rate process is essentially noiseless we get the Quantization noise .
If we make some assumptions, then we can actually calculate a more precise version of the quantization noise:
"Since aLIGO CDS system uses double precision format, quantization noise is extrapolated assuming that it scales with mantissa length"
-Denis Martynov's Thesis (pg. 173)
From this assumption, we can say that the noise difference between the 32-bit and 64-bit filter outputs: is proportional to the difference between their mantissa length. by averaging over many different bit lengths, we can estimate a better quantization noise number.
I am building the code to do this in this file |
16361
|
Mon Sep 27 16:03:15 2021 |
Ian MacMillan | Summary | Computers | Quantization Noise Calculation Summary |
I have coded up the procedure in the previous post: The result does not look like what I would expect.
As shown in Attachment1 I have the power spectrum of the 32-bit output and the 64-bit output as well as the power spectrum of the two subtracted time series as well as the subtracted power spectra of both. unfortunately, all of them follow the same general shape of the raw output of the filter.
I would not expect quantization noise to follow the shape of the filter. I would instead expect it to be more uniform. If anything I would expect the quantization noise to increase with frequency. If a high-frequency signal is run through a filter that has high quantization noise then it will severely degrade: i.e. higher quantization noise.
This is one reason why I am confused by what I am seeing here. In all cases including feeding the same and different white noise into both filters, I have found that the calculated quantization noise is proportional to the response of the filter. this seems wrong to me so I will continue to play around with it to see if I can gain any intuition about what might be happening. |
Attachment 1: DeltaNoiseSpectrum.pdf
|
|
16366
|
Thu Sep 30 11:46:33 2021 |
Ian MacMillan | Summary | Computers | Quantization Noise Calculation Summary |
First and foremost I have the updated bode plot with the mode moved to 10 Hz. See Attachment 1. Note that the comparison measurement is a % difference whereas in the previous bode plot it was just the difference. I also wrapped the phase so that jumps from -180 to 180 are moved down. This eliminates massive jumps in the % difference.
Next, I have two comparison plots: 32 bit and 64bit. As mentioned above I moved the mode to 10 Hz and just excited both systems at 3.4283Hz with an amplitude of 1. As we can see on the plot the two models are practically the same when using 64bits. With the 32bit system, we can see that the noise in the IIR filter is much greater than in the State-space model at frequencies greater than our mode.
Note about windowing and averaging: I used a Hanning window with averaging over 4 neighbor points. I came to this number after looking at the results with less averaging and more averaging. In the code, this can be seen as nperseg=num_samples/4 which is then fed into signal.welch |
Attachment 1: SS-IIR-Bode.pdf
|
|
Attachment 2: PSD_32bit.pdf
|
|
Attachment 3: PSD_64bit.pdf
|
|
16403
|
Thu Oct 14 16:38:26 2021 |
Ian MacMillan | Update | General | Kicking optics in freeSwing measurment |
[Ian, Anchal]
We are going to kick the optics tonight at 2am.
The optics we will kick are the PRM BS ITMX ITMY ETMX ETMY
We will kick each one once and record for 2000 seconds and the log files will be placed in users/ian/20211015_FreeSwingTest/logs. |
16406
|
Fri Oct 15 12:14:27 2021 |
Ian MacMillan | Update | General | Kicking optics in freeSwing measurment |
[Ian, Anchal]
we ran the free swinging test last night and the results match up with in 1/10th of a Hz. We calculated the peak using the getPeakFreqs2 script to find the peaks and they are close to previous values from 2016.
In attachment 1 you will see the results of the test for each optic.
The peak values are as follows:
Optic |
POS (Hz) |
PIT (Hz) |
YAW (Hz) |
SIDE (Hz) |
PRM |
0.94 |
0.96 |
0.99 |
0.99 |
MC2 |
0.97 |
0.75 |
0.82 |
0.99 |
ETMY |
0.98 |
0.98 |
0.95 |
0.95 |
MC1 |
0.97 |
0.68 |
0.80 |
1.00 |
ITMX |
0.95 |
0.68 |
0.68 |
0.98 |
ETMX |
0.96 |
0.73 |
0.85 |
1.00 |
BS |
0.99 |
0.74 |
0.80 |
0.96 |
ITMY |
0.98 |
0.72 |
0.72 |
0.98 |
MC3 |
0.98 |
0.77 |
0.84 |
0.97 |
The results from 2016 can be found at: /cvs/cds/rtcdt/caltech/c1/scripts/SUS/PeakFit/parameters2.m |
Attachment 1: 20211015_Kicktest_plot.pdf
|
|
16414
|
Tue Oct 19 18:20:33 2021 |
Ian MacMillan | Summary | CDS | c1sus2 DAC to ADC test |
I ran a DAC to ADC test on c1sus2 channels where I hooked up the outputs on the DAC to the input channels on the ADC. We used different combinations of ADCs and DACs to make sure that there were no errors that cancel each other out in the end. I took a transfer function across these channel combinations to reproduce figure 1 in T2000188.
As seen in the two attached PDFs the channels seem to be working properly they have a flat response with a gain of 0.5 (-6 dB). This is the response that is expected and is the result of the DAC signal being sent as a single ended signal and the ADC receiving as a differential input signal. This should result in a recorded signal of 0.5 the amplitude of the actual output signal.
The drop off on the high frequency end is the result of the anti-aliasing filter and the anti-imaging filter. Both of these are 8-pole elliptical filters so when combined we should get a drop off of 320dB per decade. I measured the slope on the last few points of each filter and the averaged value was around 347dB per decade. This is slightly steeper than expected but since it is to cut off higher frequencies it shouldn't have an effect on the operation of the system. Also it is very close to the expected value.
The ripples seen before the drop off are also an effect of the elliptical filters and are seen in T2000188.
Note: the transfer function that doesn't seem to match the others is the heartbeat timing signal. |
Attachment 1: data3_Plots.pdf
|
|
Attachment 2: data2_Plots.pdf
|
|
16423
|
Fri Oct 22 17:35:08 2021 |
Ian MacMillan | Summary | PEM | Particle counter setup near BS Chamber |
I have done some reading about where would be the best place to put the particle counter. The ISO standard (14644-1:2015) for cleanrooms is one every 1000 m^2 so one for every 30m x 30m space. We should have the particle counter reasonably close to the open chamber and all the manufactures that I read about suggest a little more than 1 every 30x30m. We will have it much closer than this so it is nice to know that it should still get a good reading. They also suggest keeping it in the open and not tucked away which is a little obvious. I think the best spot is attached to the cable tray that is right above the door to the control room. This should put it out of the way and within about 5m of where we are working. I ordered some cables to route it over there last night so when they come in I can put it up there. |
16430
|
Tue Oct 26 18:24:00 2021 |
Ian MacMillan | Summary | CDS | c1sus2 DAC to ADC test |
[Ian, Anchal, Paco]
After the Koji found that there was a problem with the power source Anchal and I fixed the power then reran the measurment. The only change this time around is that I increased the excitation amplitude to 100. In the first run the excitation amplitude was 1 which seemed to come out noise free but is too low to give a reliable value.
link to previous results
The new plots are attached. |
Attachment 1: data2_Plots.pdf
|
|
Attachment 2: data3_Plots.pdf
|
|
16447
|
Wed Nov 3 16:55:23 2021 |
Ian MacMillan | Summary | SUS | SUS Plant Plan for New Optics |
[Ian, Tega, Raj]
This is the rough plan for the testing of the new suspension models with the created plant model. We will test the suspensions on the plant model before we implement them into the full
- Get State-space matrices from the surf model for the SOS. Set up simplant model on teststand
- The state-space model is only 3 degrees of freedom. (even the surf's model)
- There are filter modules that have the 6 degrees of freedom for the suspensions. We will use these instead. I have implemented them in the same suspension model that would hold the state space model. If we ever get the state space matrices then we can easily substitute them.
- Load new controller model onto test stand. This new controller will be a copy of an existing suspension controller.
- Hook up controller to simplant. These should form a closed loop where the outputs from the controller go into the plant inputs and the plant outputs go to the controller inputs.
- Do tests on set up.
- Look at the step response for each degree of freedom. Then compare them to the results from an existing optic.
- Also, working with Raj let him do the same model in python then compare the two.
- Make sure that the data is being written to the local frame handler.
MEDM file location
/opt/rtcds/userapps/release/sus/common/medm/hsss_tega_gautam
run using
For ITMX display, use:
hsss_tega_gautam>medm -x -macro "site=caltech,ifo=c1,IFO=C1,OPTIC=ITMX,SUSTYPE=IM,DCU_ID=21,FEC=45" SUS_CUST_HSSS_OVERVIEW.adl
|
16457
|
Mon Nov 8 17:52:22 2021 |
Ian MacMillan | Update | SUS | Setting up suspension test model |
[Ian, Tega]
We combined a controler and a plant model into a single modle (See first attachment) called x1sus_cp.mdl in the userapps folder of the cymac in c1sim . This model combines 2 blocks: the controler block which is used to control the current optics and is found in cvs/cds/rtcds/userapps/release/sus/c1/models/c1sus.mdl further the control block we are using comes from the same path but from the c1sup.mdl model. This plant model is the bases for all of my custom plant models and thus is a good starting point for the testing. It is also ideal because I know it can beeasily altered into a my state-space plant model. However, we had to make a few adjustments to get the model up to date for the cds system. So it is now a unique block.
These two library blocks are set in the userapps/lib folder on the cymac. This is the lib file that the docker system looks to when it is compiling models. For a quick overview see this. All other models have been removed from the MatLab path so that when we open x1sus_cp.mdl in MatLab it is using the same models it will compile with.
We could not find the rtbitget library part, but chris pointed us to userapps, and we copied it over using: scp /opt/rtcds/userapps/trunk/cds/common/models/rtbitget.mdl controls@c1sim:/home/controls/simLink/lib .
NOTE TO FUTURE IAN: don't forget that unit delays exist.
Next step: now that we have a model that is compiling and familiar we need to make medm screens. We will use the auto mdl2adl for this so that it is quick. Then we can start adding our custom pieces one by one so that we know that they are working. We will also work with Raj to get an independent python model working. Which will allow us to compare the cds and python models. |
Attachment 1: x1sus_cp.png
|
|
16460
|
Tue Nov 9 13:40:02 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
After talking with Rana we have an updated plan. We will be working on this plan step by step in this order.
- Remove c1sim from the test stand rack and move it to the rack in the office next to the printer. When connecting it we will NOT connect it to the Martian network! This is to make sure that nothing is connected to the 40m system and we can't mess anything up.
- Once we have moved the computer over physically, we will need to update anyone who uses it on how to connect to it. The way we connect to it will have changed.
- Now that we have the computer moved and everyone can connect to it we will work on the model. Currently, we have the empty models connected.
- recompile the model since we moved the computer.
- verify that nothing has changed in the move and the model can still operate and compile properly
- The model has the proper structure but we need to fill it with the proper filters and such
- For the Plant model
- To get it up and running quickly we will use the premade plant filters for the plant model. These filters were made for the c1sup.mdl and should work in our modified plant model. This will allow us to verify that everything is working. And allow us to run tests on the system.
- We need to update the model and add the state space block. (we are skipping this step for now because we are fast-tracking the testing)
- Check with Chris to make sure that this is the right way to do it. I am pretty sure it is, but I don't know anything
- Make the 6 DOF state-space matrix. We only have a three DOF one. The surf never made a 6 DOF.
- Make the block to input into the model
- make a switch that will allow us to switch between the state-space model and the filter block
- For the controller
- Load filter coefficients for the controller model from one of the current optics and use this as a starting point.
- Add medm screens for the controller and plant. We are skipping this for now because we want results and we don't care if the screens look nice and are useable at the moment.
- Test the model
- we will take an open-loop transfer function of all six of the DOFs to all other DOFs which will leave us with 36 TFs. Many will be zero
- If you are looking at this post then we are measuring transfer functions from the blue flags to the green flags across the plant model.
- We will want to look at the TFs across the controller
|
16461
|
Tue Nov 9 16:55:52 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
We have moved c1sim computer from the test stand to the server rack in the office area. (see picture)
It is connected to the general campus network. Through the network switch at the top of the rack. This switch seeds the entire Martian network.
Test to show that I am not lying:
- you can ping it or ssh into it at
controls@131.215.114.116
Using the same password as before. Notice this is not going through the nodus network.
- It also has a different beginning of the IP addresses. Martian network IP addresses start with 191.168.113
c1sim is now as connected to the 40m network as my mom's 10-year-old laptop.
unfortunately, I have not been able to get the x2go client to connect to it. I will have to investigate further. It is nice to have access to the GUI of c1sim occasionally.
|
Attachment 1: IMG_8107.JPG
|
|
16462
|
Tue Nov 9 18:05:03 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
Now that the computer is in its new rack I have copied over the filter two files that I will use in the plant and the controller from pianosa:/opt/rtcds/caltech/c1/chans to the docker system in c1sim:/home/controls/docker-cymac/chans. That is to say, C1SUP.txt -> X1SUP.txt and C1SUS.txt -> X1SUS_CP.txt, where we have updated the names of the plant and controller inside the txt files to match our testing system, e.g. ITMX -> OPT_PLANT in plant model and ITMX -> OPT_CTRL in the controller and the remaining optics (BS, ITMY, PRM, SRM) are stripped out of C1SUS.txt in order to make X1SUS_CP.txt.
Once the filter files were copied over need to add them to the filters that are in my models to do this I run the commands:
$ cd docker-cymac
$ eval $(./env_cymac)
$ ./login_cymac
# cd /opt/rtcds/tst/x1/medm/x1sus_cp
# medm -x X1SUS_OPT_PLANT_TM_RESP.adl
see this post for more detail
Unfortunately, the graphics forwarding from the docker is not working and is giving the errors:
arg: X1SUS_OPT_PLANT_TM_RESP.adl
locateResource 'X1SUS_OPT_PLANT_TM_RESP.adl'
isNetworkRequest X1SUS_OPT_PLANT_TM_RESP.adl
canAccess('X1SUS_OPT_PLANT_TM_RESP.adl', 4) = 0
can directly access 'X1SUS_OPT_PLANT_TM_RESP.adl'
isNetworkRequest X1SUS_OPT_PLANT_TM_RESP.adl
locateResource(X1SUS_OPT_PLANT_TM_RESP.adl...) returning 1
Error: Can't open display:
This means that the easiest way to add the filters to the model is through the GUI that can be opened through X2go client. It is probably easiest to get that working. graphics forwarding from inside the docker is most likely very hard.
unfortunately again x2go client won't connect even with updated IP and routing. It gives me the error: unable to execute: startkde. Going into the files on c1sim:/usr/bin and trying to start startkde by myself also did not work, telling me that there was no such thing even though it was right in front of me.
|
16466
|
Mon Nov 15 15:12:28 2021 |
Ian MacMillan | Summary | Computer Scripts / Programs | SUS Plant Plan for New Optics |
[Ian, Tega]
We are working on three fronts for the suspension plant model:
- Filters
- We now have the state-space matrices as given at the end of this post. From these matrices, we can derive transfer functions that can be used as filter inputs. For a procedure see HERE. We accomplish this using Matlab's built-in
ss(A,B,C,D); function. then we make it discrete using c2d(sys, 1/f); this gives us our discrete system running at the right frequency. We can get the transfer functions of either of these systems using tf(sys);
- from there we can copy the transfer functions into our photon filters. Tega is working on this right now.
- State-Space
- We have our matrices as listed at the end of this post. With those compiled into a discrete system in MatLab we can use the code Chris made called
rtss.m to convert this system into a .c file and a .h file.
- from there we have moved those files under the userapps folder in the docker system. then we added a c-code block to our .mdl model for the plant and pointed it at the custom c file we made. See section 7.2 of T080135-v10
- We have done all this and this should implement a custom state-space function into our .mdl file. the downside of this is that to change our SS model we have to edit the matrices we can't edit this from an medm screen. We have to recompile every time.
- Python Check
- This python check is run by Raj and will take in the state-space matrices which are given then will take transfer functions along all inputs and outputs and will compare them to what we have from the CDS model.
Here are the State-space matrices:

A few notes: If you want the values for these parameters see the .yml file or the State-space model file. I also haven't been able to find what exactly this s is in the matrices.
UPDATE [11/16/21 4:26pm]: I updated the matrices to make them more general and eliminate the "s" that I couldn't identify.
The input vector will take the form:

where x is the position, theta is the pitch, phi is the yaw, and y is the y-direction displacement
|