ID |
Date |
Author |
Type |
Category |
Subject |
15311
|
Thu Apr 23 09:52:02 2020 |
Jon | Update | Cameras | GigE w better NIR sensitivvity |
Nice, and we should also permanently install the camera server (c1cam) which is still sitting on the electronics bench. It is running an adapted version of the Python 2/Debian 8 site code. Maybe if COVID continues long enough I'll get around to making the Python 3 version we've long discussed.
Quote: |
There's this elog from Stephen about better 1064 sensitivity from Basler. We should consider getting one if he finds that its actual SNR is as good as we would expect from the QE improvement.
|
|
1006
|
Mon Sep 29 13:33:39 2008 |
josephb | Configuration | Computers | Gigabit network finished and conlog available on Nodus |
The last 100 Mb unmounted hub has been removed (or at least of the ones I could find). We should be on a fully gigabit network with Cat6 cables and lots and lots of labels.
In other news, the pearl script that runs the web interface on linux1 for the conlog has been copied to /cvs/cds/caltech/apache/cgi-bin/ and is now being pointed to by the apache server on Nodus.
https://nodus.ligo.caltech.edu:30889/cgi-bin/conlog_web.pl |
471
|
Thu May 8 16:40:36 2008 |
josephb | Configuration | Cameras | Gige Camera currently on PSL table |
Andrey and myself were working on the PSL table today, using a pickoff of a pickoff of the main beam (adding a microscope slide to pickoff ~4% of the original pickoff) to the GC750 GigeCam.
At the time we left, we scanned the area with a beam scan and didn't see any new stray beams, and nothing in any useful beam paths should have changed. We also strung a Cat 6 cable from the control room switch out to the PSL table in the cable trays, and then above the PSL table.
Currently, its not as well aligned as it could be, and also requires a very low exposure setting, of -E 50 or so to avoid saturation. |
3082
|
Wed Jun 16 18:14:13 2010 |
Aidan | Update | General | Glass cover from overhead light smashed on PSL table |
I was giving a tour of the 40m yesterday. We were looking at the PSL table. About 30 seconds after I turned the lights on a glass cover from one of the lights (NW corner) popped out of its holder and smashed on the table.
I've cleaned up all the broken glass I could see but there may be some small shards there. Please use caution in that area. |
Attachment 1: DSC_1769.JPG
|
|
Attachment 2: DSC_1768.JPG
|
|
13199
|
Sat Aug 12 14:09:36 2017 |
gautam | Update | SUS | Glitches stay on MC1 |
Even in the switched state, the glitches stayed on MC1.
The coil driver electronics for MC1, upstream of the Satellite box, was what was previously MC3 electronics.
Attachment #1 shows that there were no glitches in MC3 sensor channels (which are now physically connected to what was previously MC1 coil driver electronics).
Attachment #2 shows the second trends for a 12 hour period for MC1 and MC3 sensor channels. The MC3 channels look well behaved, but there are frequent glitches (at least 9 in the last 12 hours ) visible in the MC1 channels.
So to recap:
- We switched MC1 satellite box - but glitch stayed on MC1, so it would seem the Satellite box is not to blame.
- We shutdown the watchdog and the glitches persisted.
- We switched the coil driver electronics for MC1, but glitches remained on MC1, and MC3 doesn't show any evidence of glitching. This and the previous bullet point suggest the coil driver electronics are not to blame.
- For the glitch posted in Attachment #1, I could see the MC-REFL spot moving around on the CCD monitors, so the glitches aren't just a feature in the shadow sensor readout.
I need to confirm that the output of the coil driver board goes straight to the Sat. Box, but if there are no intermediate elements, the problem is either in the cable from coil driver to sat. box, or downstream of the Satellite box - i.e. vacuum feedthroughs or the suspension itself? The size of the glitches is roughly the same in all 4 face channels (~60-80cts pp).
Quote: |
About 30mins ago, I saw another glitch on MC1 - this happened while the Watchdog was shutdown.
In order to further narrow down the cause of the glitch, we switched the Coil Driver Board --> Satellite box DB(15?) connectors on the coil drivers between MC1 and MC3 coil driver boards. I also changed the static PIT/YAW bias voltages to MC1 and MC3 such that MC-REFL is now approximately back to the center of the CCD monitor.
|
GV addendum 14 Aug 2017, 10.30am: Attachment #3 shows the second trend for the MC sensor channels over the weekend. While there were many on Saturday, it seems that Sunday was quieter. |
Attachment 1: MC1_glitch.png
|
|
Attachment 2: MC_12hr_trend.png
|
|
Attachment 3: MC1_glitches_intermittent.png
|
|
13200
|
Sat Aug 12 22:35:22 2017 |
rana | Update | SUS | Glitches stay on MC1 |
To add to Gautam's entry: we swapped the cables at the coil driver side (these are the ones that go from coil driver to sat box). In this state, damping is not useable since the MC1 servos would drive MC3.
~70 counts in the sensor means ~70 microns of motion. Since the watchdogs are off and the coil drivers are swapped, this can't be laser beam getting in to the sensors.
WE have to consider that these are some real strain release type events happening in the suspension wire or wire standoff, so may require a vent to inspect and possible repair MC1. |
13201
|
Sun Aug 13 01:35:09 2017 |
Koji | Update | SUS | Glitches stay on MC1 |
We used to have similar suspension excursion at ETMX. This was the motivation to replace the stand-offs from Al ones to ruby ones. Did the replacement solve the issue at ETMX? |
13206
|
Mon Aug 14 20:01:38 2017 |
gautam | Update | SUS | Glitches stay on MC1 |
I don't think we can say for sure. I was just talking to EricQ about this, he said the glitches were often seen when changing the alignment offsets when aligning the arm. I am pretty sure I have seen the ETMX alignment change abruptly since the Ruby Standoff replacement (the Oplev spot just slides across the MEDM display rapidly), but I can't find an elog where I've put in details. I also haven't done a whole lot of work with the arm cavities where I would have noticed this problem. There is this test that Eric did, and it didn't throw up any red flags. But the suspension can be well behaved for weeks at a time before this problem pops up again.
There was also the flaky power connection to the timing card on the ETMX expansion chassis which was fixed only recently, after which there has been no systematic investigation of the status of ETMX.
If it is true that these events are caused by strain building up in the suspension wire, I wonder how we can take systematic steps to avoid it. From what I remember of the SOS assembly procedure, the (unglued) standoff is slid along the optic with the wire under slight tension until the wire slips into the groove on the standoff. Then the tension in the wire is adjusted till the optic is pitch balanced and at the desired height. But it is easy to imagine imprinting some torsional stresses in the (40 um?) wire during this process of looping it around under the optic and placing it in the groove. But perhaps this mechanism makes a negligible contribution to the effect we are seeing, and some other mechanism is responsible in this case.
Quote: |
We used to have similar suspension excursion at ETMX. This was the motivation to replace the stand-offs from Al ones to ruby ones. Did the replacement solve the issue at ETMX?
|
|
14107
|
Fri Jul 27 02:30:51 2018 |
gautam | Update | General | Glitchy MC |
Kevin and I saw some weird IMC / PEM BLRMS behaviour today - see Attached screenshot. Not sure what was happening with the IMC, but MCtrans was oscillating at ~3Hz for a good 20 minutes or so. I just killed the lock, and restarted MCautolocker on megatron. There was a strange feature in the 3-10Hz BLRMS around that time as well. All seems back to normal now... |
Attachment 1: 38.png
|
|
14131
|
Fri Aug 3 18:54:58 2018 |
gautam | Update | SUS | Glitchy MC1 |
The wall StripTool indicated that the IMC wasn't too happy when I came in today. Specifically:
- MC1 watchdog was tripped.
- Even in the tripped state, MC REFL spot on the camera showed spot motion that was too large to be explained as normal seismic driven motion (i.e. with local damping supposedly disabled).
- Strange excursions were observed in the MC1 shadow sensor signal levels as well, see Attachment #1 - negative values don't make any sense for this readout.
The last time this happened, it was due to the Sorensens not spitting out the correct voltages. This time, there were no indications on the Sorensens that anything was funky. So I just disabled the MCautolocker and figured I'd debug later in the evening.
However, around 5pm, the shadow sensor values looked nominal again, and when I re-enabled the local damping, the MC REFL spot suggested that the local damping was working just fine. I re-enabled the MCautolocker, MC re-locked almost immediately. To re-iterate, I did nothing to the electronics inside the VEA. Anyways, this enabled us to work on the X arm ASS (next elog). |
Attachment 1: MC1_sensorAnomaly.png
|
|
15443
|
Tue Jun 30 22:00:04 2020 |
gautam | Update | Electronics | Glitchy POX resurfaces |
This problem reared its ugly head again. I am inclined to believe the problem is electronic and not on the light, since the POY channels seem immune to this issue (see Attachment #1). I will investigate in the daytime tomorrow. Note that while the POX photodiode head has ~twice the transimpedance than POY (per measurement), the POY signal gets amplified by a ZHL-500-HLN amplifier before heading to the demod electronics (nominal gain is 19dB = x9). There is also some imbalance in the light level at the photodiodes I guess, because overall, the PDH fringe is ~twice as large for the Y arm as the X arm. Basically, the y-axes of the attached plot cannot be directly compared between POX and POY.
Mostly this is an annoyance - right now, the POX signal is only used for locking and dither aligning the X arm cavity, and so once that is done, the locking can proceed (as long as the other channels, e.g. REFL11, aren't glitching as well...) |
Attachment 1: glitchyPOX.jpg
|
|
8220
|
Mon Mar 4 16:26:45 2013 |
Brett | Update | SUS | Global Damping Noise Measurement |
Here is an amplitude spectrum plot of y-arm cavity noise with a 50 Hz cutoff damping filter of the form zpk(0,[50;50],1). The low passing of this filter was intentionally extremely poor in order to see the damping noise in the cavity. The blue trace is the noise with no damping, which may be considered the 'best case' scenario from a noise point of view. The green has regular local damping on the ITMY. The ETMY has no damping for this measurement because the cavity control feedback to the ETMY takes care of its control when the cavity is locked. Notice the the large increase in noise from 40 Hz to 250 Hz, up to 1 order of magnitude. This noise is from the OSEM sensors passing through the damping loops. The red curve shows the y-arm noise with the exact same damping, except it is now applied in the global scheme. In this case, the damping noise falls completely below the baseline level of the cavity and becomes indistinguishable from the 'no damping' case.
If the damping injected enough noise I'd expect we would see a drop of 50 to 80 times switching from local to global. That is, the same factor measured in the transfer functions listed in log entry 8193. However, the damping noise is only at most 1 order of magnitude above the baseline in this measurement. We would have to increase the damping noise by about another order of magnitude before we could expect to see the global damping noise in the cavity measurement.
The units of the cavity displacement in the plot were calculated using the 1.4e12 counts per meter calibration in log 6834. The measured UGF of the LSC loop at the time was 205 Hz. The peak in the plot above 200 Hz appears to be from this unity crossing. Moving the UGF also moves this peak.
Moral of the story: global damping can isolate the damping noise pretty well from the cavity signal. |
Attachment 1: YARM_Noise.png
|
|
8174
|
Tue Feb 26 17:56:15 2013 |
Brett | Update | SUS | Global Damping Update |
The global damping input and output matrices were installed to run for the Y-arm. Since we are using just one arm for now, only the DARM and CARM DOFs were entered into the matrices.
The input matrix was set to have elements with magnitudes of 0.5 while the output matrix was set to have elements with magnitudes of 1. The input matrix gets the 0.5 because the sensor signals must be avergaed for each global DOF, to make an 'equivalent sensor' with the same gain. The output matrix gets magnitudes of 1 so that the overall gain of the global loops is the same as the local loops. A transfer function was measured on the CARM loop to check that the overall gain is in fact the same as the measured ITMY and ETMY loops.
Simple damping filters were installed for the ITMY and ETMY as well as the global y arm CARM and DARM loops.
The ETMY output tuning filter ETMY_GLOBPOS was set to have a gain of 0.4 because there is an extra gain of 2.5 relative to ITMY in some mysterious place as discussed in log 8172. |
8193
|
Wed Feb 27 22:28:53 2013 |
Brett | Update | SUS | Global Damping Update |
New excitation points were added after the global damping loops for more testing options. The updated c1sus.mdl model was re-committed to the svn. Two interesting simulink 'requirements' were found during this minor modification. First, excitation points must be placed on the top level of the diagram. If they are in a subsystem you will get compiling errors. Second, the excitation name must end in _EXC. It will compile OK if you don't do this, but the excitation points will not put out any excitations.
To do further investigation on the mysterious gain factor of 2.5 between the ETMY and ITMY POS damping loops, I measured TFs in the POS direction to the locked YARM signal for each. This provides an additional sensor, common to both, so we can see if the gain is coming from the actuation side or sensing side of the damping loops. The difference in these TFs is about
2.895
So it seems the majority of the damping gain difference is on the actuation side with some small difference on the sensing side. In order to allow for the later splitting of YARM LSC control between ITMY and ETMY (global damping and the cavity control must be along the same coordinate system), I placed this gain of 2.95 in ITMY_LSC.
To get a first measure of the relative performance of global damping to local damping I measured some TFs between the sensor signal inputs and YARM. So first, while the cavity was still locked with just ETMY, I measured a TF between C1:SUS-ITMY_SUSPOS_EXC and C1:LSC-YARM_IN1. Second, I split the cavity control evenly between the ETMY and ITMY by adjusting C1:LSC-OUTPUT_MTRX. I turned off the local damping and turned on the common DOF global damping (called CARM at this point despite being on just one arm). I then repeated the same TF but driving from C1:SUS-GLOBAL_CARMDAMP_EXC.
The resulting TFs are displayed in the attached figure. The blue curve is then the TF from local damping sensor noise to YARM. The green is global damping sensor noise to YARM. The suppression between local to global is in red. The global damping curve is about 50 to 100 times lower (better) than local damping. This can probably be improved with further tuning to account for remaining differences between the ITMY and ETMY.
Note, the damping loop used in the filter modules for all of these is zpk(0,[15 15],1), with a gain of 30. This purposely has little high frequency filtering so it is easier to see the influence on YARM. |
Attachment 1: DampNoise_to_YARM_fig_27Feb2013.png
|
|
8207
|
Fri Mar 1 16:37:45 2013 |
Brett | Update | SUS | Global Damping Update |
Brett and Kamal
The global damping testing for the week is now complete. The c1sus.mdl simulink diagram settled on the attached screenshot. The top level of c1sus.mdl is shown on the left zoomed in over the new global damping block. The right shows the inside of that block. Also attached in the second screenshot are two of the modal damping MEDM screens. The left shows the main overview screen, the right shows the global damping filters. The overview screen is called C1SUS_GLOBAL.adl and is found in ...medm/c1sus/master/.
We have measured transfer functions and power spectra that show that global damping, with just a moderate amount of tuning (30 minutes of work) reduces the OSEM damping noise seen by YARM_IN1 by a factor between 50 and 80. Log 8193 highlights the transfer function measurements. The power spectra directly measure the noise in the cavity. I am not putting that data here because I have to catch. I will process the data and post it here later.
Overall the global damping tests appear to have been successful, isolating (not removing) the test mass damping noise from the cavity by almost 2 orders of magnitude. Presumably even more isolation is possible with more tuning.
|
Attachment 1: GlobalDamp_Simulink.png
|
|
Attachment 2: GlobalDampScreens.png
|
|
16039
|
Fri Apr 16 00:21:52 2021 |
Koji | Update | General | Glue Freezer completely frozen |
I was looking at the laser head/amp and somehow decided to open the glue freezer. And it was stuck. I've managed to open it but the upper room was completely frozen.
Some of the batteries were embedded in a block of ice. I think we should throw them out.
Can the person who comes in the morning work on defrosting?
- Coordinate with Yehonathan and move the amps and the wooden crate so that you can move the freezer.
- Remove the contents to somewhere (it's OK to be room temp for a while)
- Unplug the freezer
- Leave the freezer outside with the door open. After a while, the ice will fall without care.
- At the end of the day, move it back to the lab. Continue defrosting the other day if the ice remains. |
Attachment 1: P_20210416_000906.jpg
|
|
Attachment 2: P_20210416_000850.jpg
|
|
16040
|
Fri Apr 16 10:58:16 2021 |
Yehonathan | Update | General | Glue Freezer completely frozen |
{Paco, Anchal, Yehonathan}
We emptied the fridge and moved the amplifier equipment on top of the amplifier crate. We unplugged the freezer and moved it out of the lab to defrost (attachment).
Quote: |
I was looking at the laser head/amp and somehow decided to open the glue freezer. And it was stuck. I've managed to open it but the upper room was completely frozen.
Some of the batteries were embedded in a block of ice. I think we should throw them out.
Can the person who comes in the morning work on defrosting?
- Coordinate with Yehonathan and move the amps and the wooden crate so that you can move the freezer.
- Remove the contents to somewhere (it's OK to be room temp for a while)
- Unplug the freezer
- Leave the freezer outside with the door open. After a while, the ice will fall without care.
- At the end of the day, move it back to the lab. Continue defrosting the other day if the ice remains.
|
|
Attachment 1: 20210416_105048.jpg
|
|
16045
|
Fri Apr 16 19:07:31 2021 |
Yehonathan | Update | General | Glue Freezer completely frozen |
There is still a huge chunk of unmelted ice in the fridge. I moved the content of that fridge in the main fridge and put "do not eat" warning signs.
I returned the fridge to the lab and plugged it back in to prevent flooding.
Defrosting will have to continue on Monday. |
16048
|
Mon Apr 19 10:52:27 2021 |
Yehonathan | Update | General | Glue Freezer completely frozen |
{Anchal, Paco, Yehonathan}
We took the glue fridge outside. |
16051
|
Mon Apr 19 19:40:54 2021 |
Yehonathan | Update | General | Glue Freezer completely frozen |
{Paco, Yehonathan}
We broke the last chunk of ice and cleaned the fridge. We move the fridge back inside and plugged it into the wall. The glues were moved back from the main fridge.
The batteries that were found soaking wet are now somewhat dry and were left on the cabinet drawers for future recycling.
Quote: |
{Anchal, Paco, Yehonathan}
We took the glue fridge outside.
|
|
3958
|
Fri Nov 19 18:20:59 2010 |
Suresh | Update | SUS | Glue dynamics! |
I examined the magnet-dumbbell joints under the microscope to see whether the glue that I applied yesterday was sufficient or in excess.
I think the pictures below speak for themselves !
During the gluing process the Al dumbbell stays below and the magnet with a drop of glue on the lower face is placed on it and held in the teflon fixture. As seen in the pics the glue seems to have run up the surface of the magnet and has not collected in the narrow part of the dumbell. So it has climbed up along the narrow gaps between the magnet and the teflon fixture by capillary action. The glue stops where the teflon fixture ends, a little before reaching the free end of the magnet, which further indicates the capillary action.
|
Attachment 2: Too_much_glue_2.jpg
|
|
2618
|
Fri Feb 19 15:29:14 2010 |
kiwamu | Update | COC | Gluing dumbbells and magnets |
Jenne and kiwamu
We have glued the dumbbells to the magnets that will be used for the ITMs
We made two sets of glued pair of the dumbbell and the magnet ( one set means 6 pairs of the dumbbell and the magnet. Therefore in total we got 12 pairs. )
You can see the detailed procedure we did on the LIGO document E990196.
Actually we performed one different thing from the documented procedure;
we made scratch lines on the surface of the both dumbbells and magnets by a razor blade.
According to Steve and Bod, these scratch make the strength of the glues stronger.
Now the dumbbell-magnet pairs are on the flow bench in the clean room, and supported by a fixture Betsy sent us.
- - notes
On the bench the left set is composed by magnets of 244 +/- 3 Gauss and the right set is 255 +/- 3 Gauss.
|
12305
|
Fri Jul 15 16:23:51 2016 |
ericq | Update | General | Gluing setbacks |
[ericq, Lydia]
Here is a picture of the ETMX guide rod post-gluing. There is unfortunately a fair amount of excess. The "tab" is the result from the epoxy travelling along the finger of the fixture arm that held the guide rod.

We set out to glue the previously remove ETMX side magnet, and set up the fixture to do so. For ETMX we needed 3 mm of shimming on the thick side, and 6mm on the thin side.
However, while cleaning the magnet+dumbbell base of epoxy residue, I broke the dumbbell off of the magnet 
We then fetched the spare side magnet that Steve had been holding onto. While cleaning it, it was dropped and dissapeared from this plane of existence  
So, instead of gluing a side magnet today, we are gluing the existing magnet and dumbbell back together:

Sadly, this used up the last of our EP30.  
Though Koji had the foresight to order more( ), it will not arrive until Monday/Tuesday, so no side magnet gluing until then. |
5850
|
Wed Nov 9 16:03:21 2011 |
kiwamu | Summary | General | Goal this week |
Goal of this week : ALS on the Y arm
Minimum success : Detection of the green beatnote between the freq-doubled PSL and the Y arm transmitted light
|
5885
|
Mon Nov 14 11:32:02 2011 |
kiwamu | Summary | General | Goal this week |
Goal of this week : Noise budgeting on the Y arm ALS
Minimum success : bring the Y arm to the resonance by using ALS NOISE BUDGETING!!!
=> as a preparation the incident beam pointing needs to be fixed by steering the MC suspensions.
|
3651
|
Tue Oct 5 14:11:09 2010 |
josephb, alex | Update | CDS | Going to from rtlinux to Gentoo requires front end code clean out |
Apparently when updating front end codes from rtlinux to the patched Gentoo, certain files don't get deleted when running make clean, such as the sysfe.rtl files in the advLigoRTS/src/fe/sys directories. This fouls the start up scripts by making it think it should be configured for rtlinux rather than the Gentoo kernel module. |
13304
|
Fri Sep 8 12:08:32 2017 |
Gabriele | Summary | LSC | Good reconstruction of PRMI degrees of freedom with deep learning |
Introduction
This is an update of my previous reports on applications of deep learning to the reconstruction of PRMI degrees of freedom (MICH/PRCL) from real free swinging data. The results shown here are improved with respect to elog 13274 and 13294. The training is performed in two steps, the first one using simulated data, and the second one fine tuning the parameters on real data.
First step: training with simulation
This step is exactly the same already described in the previous entries and in my talks at the CSWG and LVC. For details on the DNN architecture please refer to G1701455 or G1701589. Or if you really want all the details you can look at the code. I used the following signals as input to the DNN: POPDC, POP22_Q, ASDC, REFL11_I/Q, REFL55_I/Q, AS55_I/Q. The network is trained using linear trajectories in the PRCL/MICH space, and signals obtained from a model that simulates the PRMI behavior in the plane wave approximation. A total of 150000 trajectories are used. The model includes uncertainties in all the optical parameters of the 40m PRMI configuration, so that the optical signals for each trajectory are actually computed using random optical parameteres, drwn from gaussian distributions with proper mean and width. Also, white random gaussian sensing noise is added to all signals with levels comparable to the measured sensing noise.
The typical performance on real data of a network pre-trained in this way was already described in elog 13274, and although being reasoble, it was not too good.
Second step: training with real data
Real free swinging data is used in this step. I fine tuned the demodulation phases of the real signals. Please note that due to an old mistake, my convention for phases is 90 degrees off, so for example REFL11 is tuned such that PRCL is maximized in Q instead of I. Regardless of this convention confusion, here's how I tuned the phases:
- REFL11: PRCL is all in Q when crossing the carrier resonance
- REFL55: PRCL is all in Q when crossing the carrier resonance
- AS55: MICH is all in Q when crossing the PRCL carrier resonance
- POP22: signal peaking in Q when crossing carrier or sideband resonances. Carrier resonance crossing gives positive sign
Then I built the following training architecture. The neural network takes the real signals and produces estimates of PRCL and MICH for each time sample. Those estimates are used as the input for the PRMI model, to produce the corresponding simulated optical signals. My cost function is the squared difference of the simulated versus real signals. The training data is generated from the real signals, by selection 100000 random 0.25s long chunks: the history of real signal over the whole 0.25s is used as input, and only the last sample is used for the cost function computation. The weights and biases of the neural network, as well as the model parameters are allowed to change during the learning process. The model parameters are regularized to suppress large deviations from the nominal values.
One side note here. At first sight it might seems weird that I'm actually fedding as input the last sample and at the same time using it as the reference for the loss function. However, you have to remember that there is no "direct" path from input to output: instead all goes through the estimated MICH/PRCL degrees of freedom, and the optical model. So this actually forces the network to tune the reconstruction to the model. This approach is very similar to the auto-encoder architectures used in unsupervised feature learning in image recognition.
Results
After trainng the network with the two previous steps, I can produce time domain plots like the one below, which show MICH and PRCL signals behaving reasonably well:

To get a feeling of how good the reconstruction is, I produced the 2d maps shown below. I divided the MICH/PRCL plane in 51x51 bins, and averaged the real optical signals with binning determined by the reconstructed MICH and PRCL degrees of freedom. For comparison the expected simulation results are shown. I would say that reconstructed and simulated results match quite well. It looks like MICH reconstruction is still a bit "compressed", but this should not be a big issue, since it should still work for lock acquisition.
 
Next steps
There a few things that can be done to futher tune the network. Those are mostly details, and I don't expect significant improvements. However, I think the results are good enough to move on to the next step, which is the on-line implementation of the neural network in the real time system. |
14044
|
Sun Jul 8 12:20:12 2018 |
Jon | Summary | AUX | Gouy Phase Measurements from AUX-Laser Scans |
This note reports analysis of cavity scans made by directly sweeping the AUX laser carrier frequency (no sidebands). The measurement is made by sweeping the RF offset of the AUX-PSL phase-locked loop and demodulating the cavity reflection/transmission signal at the offset frequency.
Y-Arm Scan
Due to the simplicity of its expected response, the Y-arm cavity was scanned first as a test of the AUX hardware and the sensitivity of the technique. Attachment 1 shows the measured cavity transmission with respect to RF drive signal.

The AUX laser launch setup is capable of injecting up to 9.3 mW into the AS port. This high-power measurement is shown by the black trace. The same measurement is repeated for a realistic SQZ injection power, 70 uW, indicated by the red curve. At low power, the technique still clearly resolves the FSR and six HOM resonances. From the identified mode resonance frequencies the following cavity parameters are directly extracted.
YARM |
Gautam's Finesse Model |
Actual |
FSR |
3.966 MHz |
3.967 MHz |
Gouy phase |
54.2 deg |
52.0 deg |
PRC Scan
An analogous scan was performed for the PRC, with the IFO locked on PSL carrier in PRMI. Attachment 2 shows the measurement of PRC transmission with respect to drive signal.

The scan resolves HOM resonances to at least ~13th order, whose frequencies yield the following cavity parameters.
PRC |
Gautam's Finesse Model |
Actual |
FSR |
22.30 MHz |
22.20 MHz |
Gouy phase |
13.4 deg |
15.4 deg |
SRC Scan
Ideally (and at the sites) the SRC mode resonances will be measured in SRMI configuration. Because every other cavity is misaligned, this configuration provides an easily-interpretable spectrum whose resonances can all be attributed to the SRC.
Due to time constraints at the 40m, the IFO could not be restored to lockability in SRMI. It has been more than two years since this configuration was last run. For this reason the scan was made instead with the IFO locked in DRMI, as shown in Attachment 3. The quantity measured is the AUX reflection with respect to drive signal.
This result requires far more interpretation because resonances of both the SRC and PRC are superposed. However, the resonances of the PRC are known a priori from the independent PRMI scan. The SRC mode resonances identified below do not conincide with any of the first five PRC mode resonances.

Based on the identified mode resonance frequencies, the SRC parameters are measured as follows.
SRC |
Gautam's Finesse Model |
Actual |
FSR |
27.65 MHz |
27.97 MHz |
Gouy phase |
10.9 deg |
8.8 deg |
Lessons Learned
From experience with the 40m, the main challenges to repeating this measurement at the sites will be the following.
- Pointing jitter of the input AUX beam. This causes the PSL-AUX beam overlap to vary at transmission (or reflection), causing variation in the amplitude of the AUX-PSL beat note. As far as we can tell, the frequency of the resonances (the only object of this measurement) is not changing in time, only the relative amplitudes of the diferent mode peaks. I believe the SQZ alignment loops will mitigate this problem at the sites.
- Stabilization of the network analyzer time base. We found the intrinsic frequency stability of the network analyzer (Agilent 4395A) to be unacceptably large. We solved this problem by phase-locking the Agilent to an external reference, a 10-MHz signal provided by an atomic clock.
|
Attachment 1: yarm_aux_carrier_trans.pdf
|
|
Attachment 2: prmi_aux_carrier_trans.pdf
|
|
Attachment 3: drmi_aux_carrier_trans.pdf
|
|
Draft
|
Wed Jul 11 18:13:19 2018 |
keerthana | Summary | AUX | Gouy Phase Measurements from AUX-Laser Scans |
From the Measurement Jon made, FSR is 3.967 MHz and the Gouy phase is 52 degrees. From this, the length of the Y-arm cavity seems to be 37.78 m and the radius of curvature of the mirror seems to be 60.85 m.



FSR = Free spectral Range
L = Lenth of the arm
R = Radius of curvature of the mirror (R1 = , R2= unknown)
Quote: |
This note reports analysis of cavity scans made by directly sweeping the AUX laser carrier frequency (no sidebands). The measurement is made by sweeping the RF offset of the AUX-PSL phase-locked loop and demodulating the cavity reflection/transmission signal at the offset frequency.
Y-Arm Scan
Due to the simplicity of its expected response, the Y-arm cavity was scanned first as a test of the AUX hardware and the sensitivity of the technique. Attachment 1 shows the measured cavity transmission with respect to RF drive signal.

The AUX laser launch setup is capable of injecting up to 9.3 mW into the AS port. This high-power measurement is shown by the black trace. The same measurement is repeated for a realistic SQZ injection power, 70 uW, indicated by the red curve. At low power, the technique still clearly resolves the FSR and six HOM resonances. From the identified mode resonance frequencies the following cavity parameters are directly extracted.
YARM |
Gautam V. Finesse Model |
Actual |
FSR |
3.966 MHz |
3.967 MHz |
Gouy phase |
54.2 deg |
52.0 deg |
|
|
14822
|
Thu Aug 1 13:55:34 2019 |
Duo | Bureaucracy | Equipment loan | Gpib module taken to QIL lab |
vanna --> QIL.
gautam 20190804: The GPIB module + power supply were returned to me by Duo ~5pm today at the 40m. |
4433
|
Wed Mar 23 14:19:35 2011 |
Koji | Summary | General | Grand Plan |
This is the grand plan we talked about in the beginning of the meeting.
- (Kiwamu) X-end Green cleaning up / Prep for DRMI
- (Bryan) Y-end Green
- (Suresh) Help Bryan / RF (w. Kevin)
- (Jenne) MC WFS / Y-arm IR alignment / MC adaptive feedforward (incl. CDS)
- (Koji) LSC
- (Joe) CDS cleaning up
- (Jamie) Help Joe / Noise Budget
- (Larisa) PMC scan / PSL photo&diagram
- (Barbarela) ASS
|
3018
|
Sun May 30 22:18:49 2010 |
rana | Update | PEM | Granite slab w/ lead balls is so far a flop |
The seismometers showed an increased noise in the Y-direction when put on top of the granite slab. By tapping the slab, you can tell that its really a mechanical resonance of the lead balls + granite system at ~15-20 Hz.
I tried new balls, flipping the slab upside down, and sitting on the slab for awhile. None of this changed the qualitative behavior, although each of the actions changed the resonance frequencies by several Hz.
I have removed the granite/balls and put the seismometers back on the linoleum floor. The excess noise is gone. I have put the new big box back on top of them and we'll see how the data looks overnight.
I expect that we should remove the linoleum in a wider area and put the seismometers directly on the floor. |
3022
|
Mon May 31 22:52:57 2010 |
rana | Update | PEM | Granite slab w/ lead balls is so far a flop |
This plot shows the noise with the box on, but no granite. We're still pretty far off from the Guralp data sheet.

I implemented software rotation in the huddle subtraction as Valera suggested and it works much better. The two plots below show the before and after. So far this is just 2 deg. of rotation around the z-axis. I'm assuming that aligning the seismometers vertically via bubble level is good enough for the z-axis, but I haven't calibrated the bubble yet.
 
The residual slope is now suspiciously smooth. I somehow suspect that our readout electronics can still be responsible. We need to hook up a 9V battery to the input terminals to check it out. Its a little steeper than 1/f and I thought that we had exonerated the Guralp breakout box in the past, but now I'm not so sure. I'll let Jenne comment on that.
I also noticed that we have not yet divided by sqrt(2) to account for the fact that we are subtracting 2 seismometers. In principle, an unbiased estimate of the single seismometer noise will be lower by sqrt(2) than the green curve. |
8414
|
Thu Apr 4 13:39:12 2013 |
Max Horton | Update | Summary Pages | Graph Limits |
Graph Limits: The limits on graphs have been problematic. They often reflect too large of a range of values, usually because of dropouts in data collection. Thus, they do not provide useful information because the important information is washed out by the large limits on the graph. For example, the graph below shows data over an unnecessarily large range, because of the dropout in the 300-1000Hz pressure values.

The limits on the graphs can be modified using the config file found in /40m-summary/share/c1_summary_page.ini. At the entry for the appropriate graph, change the amplitude-lim=y1,y2 line by setting y1 to the desired lower limit and y2 to the desired upper limit. For example, I changed the amplitude limits on the above graph to amplitude-lim=.001,1, and achieved the following graph.

The limits could be tightened further to improve clarity - this is easily done by modifying the config file. I modified the config file for all the 2D plots to improve the bounds. However, on some plots, I wasn't sure what bounds were appropriate or what range of values we were interested in, so I will have to ask someone to find out.
Next: I now want to fix all the funny little problems with the site, such as scroll bars appearing where they should not appear, and graphs only plotting until 6PM. In order to do this most effectively, I need to restructure the code and factor it into several files. Otherwise, the code will not only be much harder to edit, but will become more and more confusing as I add on to it, compounding the problems that we currently have (i.e. that this code isn't very well documented and nobody knows how it works). We need lots of specific documentation on what exactly is happening before too many changes are made. Take the config files, for example. Someone put a lot of work into them, but we need a README specifying which options are supported for which types of graphs, etc. So we are slowed down because I have to figure out what is going on before I make small changes.
To fix this, I will divide the code into three main sectors. The division of labor will be:
- Sector 1: Figure out what the user wants (i.e. read config files, create a ConfigParser, etc...)
- Sector 2: Process the data and generate the plots based on what the user wants
- Sector 3: Generate the HTML |
3418
|
Fri Aug 13 01:53:12 2010 |
Gopal | Update | Optic Stacks | Gravity Implementation Confirmed |
Time Domain Analysis on a Driven, Damped Simple Pendulum has produced a method for implementing gravity. 
COMSOL made this simple task a cryptic one: the following methods had previously failed:
- Previous Frequency Domain testing lead to unwanted oscillations of all loads.
- Prescribed accelerations at first seemed to create a constant gravity, but instead incorrectly constrained net acceleration to the inputted amount
Methodology:
1) An (approximately) impulse displacement was applied in the horizontal direction. The pendulum bob's displacement was observed for varying pendulum lengths.
2) The drive and response displacements vs. time were FFT'd to produce transfer functions.
3) The fundamental frequencies were inverted, squared, and plotted against frequency.
4) Since the graph is linear with an R^2 of over 0.99, it is reasonable to assume that gravity is properly acting as a restoration force.

|
Attachment 1: Pendulum_Length.png
|
|
Attachment 2: Pendulum_Length.png
|
|
15062
|
Tue Dec 3 00:03:57 2019 |
gautam | Update | LSC | Green ALS also shows elevated noise with high arm buildup |
Summary:
- While noisier, I was able to control the arm lengths to ~30pm RMS(!) using the green ALS beats as error signals (cf. ~10 pm RMS with the IR ALS system).
- The PRMI could be locked with a CARM offset applied.
- When lowering the CARM offset, I saw an increase in the in-loop ALS error signal, just as I had with the IR beat.
- IR TRX / TRY unsurprisingly did not stabilize in any meaningful way.

- The noise increase seems to have some periodicity along the frequency axis - need to think about what this means.
- Since there is no apparent benefit to using the green ALS beats, I restored the IR system. The green PDs should still retain somewhat good alignment if one wishes to do a comparison measurement.
- While the shadow sensors of the ITMs report elevated noise, it is unlikely to be responsible for the cavity moving by the amount suggested by the elevated ALS error signals because of the digital low-pass filtering and 1/f^2 of the pendulum.
- I confirmed that the ITM shadow sensors do not report elevated noise when the PRMI is locked such that the carrier is resonant. In this config, there is comparable circulating power in the PRC as to when the CARM offset is reduced to ~0.
- The fact that the IR and green beats both show similar increase in noise suggestes that the cavity length / laser frequency is in fact being modulated, but I still don't know what the exact mechanism is.
was worth a shot i guess.
Trawling through some elogs, I see that this kind of feature showing up in the ALS CARM is not a new problem, see for example here. But I can't find out what the resolution was. |
Attachment 1: ALSnoiseIncrease_greenBeat.pdf
|
|
15058
|
Mon Dec 2 00:27:20 2019 |
gautam | Update | ALS | Green ALS resurrection |
Attachment #1 - comparison of phase tracker servo angle fluctuations for the green beat vs IR beat.
- To convert to Hz, I used the PT servo calibration detailed here.
- This is only a function of the delay line length and not the signal strength, so shouldn't be affected by the difference in signal strength between the IR and green beats.
- For the green beat - I divided the measured spectra by 2 to convert the green beat frequency fluctuations into equivalent IR frequency fluctuations.
- There is no whitening before digitization. I believe the measured spectra are dominated by ADC noise above ~50 Hz. See this elog for the frequency discriminant as a funtion of signal strength, so 5uV/rtHz ADC noise would be ~2 Hz/rtHz for a -5dBm signal, which is what I expect for the Y beat, and ~0.5 Hz/rtHz for a +5dBm signal, which is what I expect for the X beat. Hence the brown (Green beat, XARM) being lower than the green trace (IR beat, XARM) isn't real, it is just because of my division of 2. So I guess that calibration factor I applied is misleading.
- I did not yet check the noise in the other configuration - arm lengths controlled using ALS, and POX/POY as the OOL sensors. To be tried tonight.
Attachment #2 - RIN of the DCPDs.
- I noticed that over 10s of seconds, the GTRY level was fluctuating by ~5%.
- This was much more than any drift seen in the GTRX level.
- Measuring the RIN on the DCPDs (Thorlabs PDA36A) supports this observation (spectra were divided by DC value to convert into RIN units).
- There is ~120uW (1.6 VDC, compatible with 30dB gain setting) incident on the GTRX PD, and ~6uW (170 mVDC, compatible with 40dB gain setting) incident on the GTRY PD.
- Not sure what is driving this drift - I don't see any coherence with the IR TRY signal, so doesn't seem like it's the cavity.
Characterization of the green beat setup [past numbers]:
- With some patient alignment effort (usual near-field/far-field matching), I was able to recover the green beat signals.
- Overall, the numbers I measured today are consistent with what was seen in the past when we had the ability to lock using green ALS.
- The mode-matching between the PSL and AUX green beams are still pretty abysmal, ~40-50%. The mode shapes are clearly different, but for now, I don't worry about this.
- I saw some strong AM of the beat signal (for both EX and EY beats) while I was looking at it on a scope, see Attachment #3. This AM is not visible in the IR beat, not sure what to make of it. The frequency of the AM is ~1 MHz, but it's hard to nail this down because the scope doesn't have a very long buffer, and I didn't look at the frequency content on the Agilent (yet).
o BBPD DC output (mV), all measured with Fluke DMM
XARM YARM
V_DARK: +1.0 +2.0
V_PSL: +8.0 +13.0
V_ARM: +157.0 +8.0
o BBPD DC photocurrent (uA)
I_DC = V_DC / R_DC ... R_DC: DC transimpedance (2kOhm)
I_PSL: 3.5 5.5
I_ARM: 78.0 3.0
o Expected beat note amplitude
I_beat_full = I1 + I2 + 2 sqrt(e I1 I2) cos(w t) ... e: mode overlap (in power)
I_beat_RF = 2 sqrt(e I1 I2)
V_RF = 2 R sqrt(e I1 I2) ... R: RF transimpedance (2kOhm)
P_RF = V_RF^2/2/50 [Watt]
= 10 log10(V_RF^2/2/50*1000) [dBm]
= 10 log10(e I1 I2) + 82.0412 [dBm]
= 10 log10(e) +10 log10(I1 I2) + 82.0412 [dBm]
for e=1, the expected RF power at the PDs [dBm]
P_RF: -13.6 -25.8
o Measured beat note power (measured with oscilloscope, 50 ohm input impedance)
P_RF: -17.95dBm (80 mVpp) -28.4dBm (24mVpp) (40MHz and 42MHz)
e: 37% 55 [%]
I also measured the various green powers with the Ophir power meter (filter off):
o Green light power (uW) [measured just before PD, does not consider reflection off the PD]
P_PSL: 18 24
P_ARM: 400 13
The IR beat is not being made at the moment because I blocked the PSL beam entering the fiber. |
Attachment 1: ALSnoiseComparison.pdf
|
|
Attachment 2: ALS_TR_RIN.pdf
|
|
Attachment 3: GreemAM.pdf
|
|
9406
|
Tue Nov 19 00:18:30 2013 |
Jenne | Update | LSC | Green ALS wishlist |
EricQ said that he's going to start hanging out at the 40m a bit, and I was thinking about what I can have him help me with. This lead to me writing up a wishlist for things that have to do with the ALS system and green lasers. Some of these are very small tasks, while others are pretty big. They are certainly not all high priority. But, they're on my wishlist.
Calibrations
- How many counts of SLOW_SERVO2_OFFSET is one green FSR (for each arm)?
- Calibrate ALS OFFSETTER#_OFFSET counts to nm or Hz offset between the end lasers and the PSL.
Automation / script writing
- Automate finding the beatnotes (requires freq counters)
- Automate locking the ALS
Digital Acquisition
- All 3 laser temperatures
- Frequency counting of beatnotes
Hardware
- Install flipper mirrors on the PSL table to switch between trans DCPDs and far-field views of beam overlap for each arm.
- IR beatnote project - send pickoff of end lasers to PSL via fiber, set up beat detection for each arm, create PLLs.
- Yarm PZT installation and autoalignment.
|
16845
|
Wed May 11 15:49:42 2022 |
JC | Update | OPLEV Tables | Green Beam OPLEV Alignment |
[Paco, JC]
Paco and I began aligning the Green Beam in the BS Oplev Table. while aligning the GRN-TRX, the initial beam was entering the table a bit low. To fix this, Paco went into the chamber and correcting the pitch with the steering mirror. The GRN-TRX is now set up, both the PD and Camera. Paco is continuing to work on the GRN-TRY and will update later on today.
In the morning, I will update this post with photos of the new arrangement of the BS OPLEV Table.
Update Wed May 11 16:54:49 2022
[Paco]
GRY is now better mode matched to the YARM and is on the edge of locking, but it more work is needed to improve the alignment. The key difference this time with respect to previous attempts was to scan the two lenses on translation stages along the green injection path. This improved the GTRY level by a factor of 2.5, and I know it can be further improved. Anyways, the locked HOMs are nicely centered on the GTRY PD, so we are likely done with the in-vac GTRY GTRX alignment.
Update Wed May 12 10:59:22 2022
[JC]
The GTRX PD is now set up and connected. The camera have been set to an angle because the cable to connect it is too thick for the camera to maintain its original position along the side.
|
Attachment 1: IMG_0770.jpeg
|
|
2907
|
Mon May 10 20:03:22 2010 |
Kevin | Update | Green Locking | Green Laser Beam Profile |
Kiwamu and Kevin measured the beam profile of the green laser by the south arm ETM.
The following measurements were made with 1.984A injection current and 39.65°C laser crystal temperature.
Two vertical scans (one up and one down) were taken with a razor blocking light entering a photodiode with the razor 7.2cm from the center of the lens. This data was fit to
b + a*erf(sqrt(2)*(x-x0)/w) with the following results:
scan down: w = (0.908 ± 0.030)mm chi^2 = 3.8
scan up: w = (0.853 ± 0.025)mm chi^2 = 2.9
giving a weighted value of w = (0.876 ± 0.019)mm at this distance.
The beam widths for the profile fits were measured with the beam scanner. The widths are measured as the full width at 13.5% of the maximum. Each measurement was averaged over 100 samples. The distance is measured from the back of the lens mount to the front face of the beam scanner.
distance (cm) |
vertical w (µm) |
horizontal w (µm) |
3.2 ± 0.1 |
1231 ± 8 |
1186 ± 7 |
4.7 ± 0.1 |
1400 ± 4 |
1363 ± 6 |
7.4 ± 0.1 |
1656 ± 5 |
1625 ± 9 |
9.6 ± 0.1 |
1910 ± 10 |
1863 ± 9 |
12.5 ± 0.1 |
2197 ± 8 |
2176 ± 8 |
14.6 ± 0.1 |
2450 ± 12 |
2416 ± 10 |
17.5 ± 0.1 |
2717 ± 12 |
2694 ± 14 |
20.0 ± 0.1 |
2973 ± 16 |
2959 ± 8 |
22.4 ± 0.1 |
3234 ± 12 |
3193 ± 14 |
This data was fit to w = sqrt(w0^2+lambda^2*(x-x0)^2/(pi*w0)^2) with lambda = 532nm with the following results:
For the vertical beam profile:
reduced chi^2 = 3.29
x0 = (-87 ± 1) mm
w0 = (16.30 ± 0.14) µm
For the horizontal beam profile:
reduced chi^2 = 2.01
x0 = (-82 ± 1) mm
w0 = (16.12 ± 0.10) µm
Note: These fits were done with the beam diameter instead of the beam radius. The correct fits to the beam radius are here: http://nodus.ligo.caltech.edu:8080/40m/2912
|
Attachment 1: vbp.jpg
|
|
Attachment 2: vbp_residuals.jpg
|
|
Attachment 3: hbp.jpg
|
|
Attachment 4: hbp_residuals.jpg
|
|
2909
|
Mon May 10 22:25:03 2010 |
Koji | Update | Green Locking | Green Laser Beam Profile |
Hey, what a quick work!
But, wait...
1) The radius of the beam was measured by the razor blade.
2) The diameter of the beam (13.5% full-width) at each point was measured by Beam Scan. The one at z=~7cm was consistent with 1)
3) The data 2) was fitted by a function w = sqrt(w0^2+lambda^2*(x-x0)^2/(pi*w0)^2). This is defined for the radius, isn't it?
So the fitting must be recalculated with correct radius.
Make sure that you always use radius and write with a explicit word "radius" in the record.
Quote: |
Kiwamu and Kevin measured the beam profile of the green laser by the south arm ETM.
The following measurements were made with 1.984A injection current and 39.65°C laser crystal temperature.
Two vertical scans (one up and one down) were taken with a razor blocking light entering a photodiode with the razor 7.2cm from the center of the lens. This data was fit to
b + a*erf(sqrt(2)*(x-x0)/w) with the following results:
scan down: w = (0.908 ± 0.030)mm chi^2 = 3.8
scan up: w = (0.853 ± 0.025)mm chi^2 = 2.9
giving a weighted value of w = (0.876 ± 0.019)mm at this distance.
The beam widths for the profile fits were measured with the beam scanner. The widths are measured as the full width at 13.5% of the maximum. Each measurement was averaged over 100 samples. The distance is measured from the back of the lens mount to the front face of the beam scanner.
distance (cm) |
vertical w (µm) |
horizontal w (µm) |
3.2 ± 0.1 |
1231 ± 8 |
1186 ± 7 |
4.7 ± 0.1 |
1400 ± 4 |
1363 ± 6 |
7.4 ± 0.1 |
1656 ± 5 |
1625 ± 9 |
9.6 ± 0.1 |
1910 ± 10 |
1863 ± 9 |
12.5 ± 0.1 |
2197 ± 8 |
2176 ± 8 |
14.6 ± 0.1 |
2450 ± 12 |
2416 ± 10 |
17.5 ± 0.1 |
2717 ± 12 |
2694 ± 14 |
20.0 ± 0.1 |
2973 ± 16 |
2959 ± 8 |
22.4 ± 0.1 |
3234 ± 12 |
3193 ± 14 |
This data was fit to w = sqrt(w0^2+lambda^2*(x-x0)^2/(pi*w0)^2) with lambda = 532nm with the following results:
For the vertical beam profile:
reduced chi^2 = 3.29
x0 = (-87 ± 1)mm
w0 = (16.30 ± 0.14)µm
For the horizontal beam profile:
reduced chi^2 = 2.01
x0 = (-82 ± 1)mm
w0 = (16.12 ± 0.10)µm
|
|
2910
|
Tue May 11 14:39:17 2010 |
Aidan | Update | Green Locking | Green Laser Beam Profile |
Here's a photo of the set-up used. The beam profile is measured relative to the f=-100mm lens. |
Attachment 1: P5110057_beams.jpg
|
|
2912
|
Tue May 11 17:02:43 2010 |
Kevin | Update | Green Locking | Green Laser Beam Profile |
Quote:
|
Hey, what a quick work!
But, wait...
1) The radius of the beam was measured by the razor blade.
2) The diameter of the beam (13.5% full-width) at each point was measured by Beam Scan. The one at z=~7cm was consistent with 1)
3) The data 2) was fitted by a function w = sqrt(w0^2+lambda^2*(x-x0)^2/(pi*w0)^2). This is defined for the radius, isn't it?
So the fitting must be recalculated with correct radius.
Make sure that you always use radius and write with a explicit word "radius" in the record.
|
I recalculated the fits using the radius of the beam instead of the diameter of the beam at 13.5% full-width with the following results:
For the vertical beam profile:
reduced chi^2 = 3.25
x0 = (-86 ± 1)mm
w0 = (46.01 ± 0.38)µm
For the horizontal beam profile:
reduced chi^2 = 2.05
x0 = (-81 ± 1)mm
w0 = (45.50 ± 0.28)µm |
Attachment 1: vbp.jpg
|
|
Attachment 2: vbp_residuals.jpg
|
|
Attachment 3: hbp.jpg
|
|
Attachment 4: hbp_residuals.jpg
|
|
2916
|
Wed May 12 03:42:38 2010 |
Koji | Update | Green Locking | Green Laser Beam Profile |
Strange. I thought the new result became twice of the first result. i.e. w0=32um or so.
Can you explain why the waist raidus is estimated to be three times of the last one?
Can you explain why the measured radius @~70mm is not 0.8mm, which you told us last time,
but is 0.6mm?
The measurements have been done at the outside of the Rayleigh range.
This means that the waist size is derived from the divergence angle
theta = lambda / (pi w0)
At the beginning you used diameter instead of radius. This means you used twice larger theta to determine w0.
So if that mistake is corrected, the result for w0 should be just twice of the previous wrong fit.
Quote: |
I recalculated the fits using the radius of the beam instead of the diameter of the beam at 13.5% full-width with the following results:
For the vertical beam profile:
reduced chi^2 = 3.25
x0 = (-86 ± 1)mm
w0 = (46.01 ± 0.38)µm
For the horizontal beam profile:
reduced chi^2 = 2.05
x0 = (-81 ± 1)mm
w0 = (45.50 ± 0.28)µm
|
|
2933
|
Fri May 14 16:14:37 2010 |
Kevin | Update | Green Locking | Green Laser Beam Profile |
Quote: |
Strange. I thought the new result became twice of the first result. i.e. w0=32um or so.
Can you explain why the waist raidus is estimated to be three times of the last one?
Can you explain why the measured radius @~70mm is not 0.8mm, which you told us last time,
but is 0.6mm?
The measurements have been done at the outside of the Rayleigh range.
This means that the waist size is derived from the divergence angle
theta = lambda / (pi w0)
At the beginning you used diameter instead of radius. This means you used twice larger theta to determine w0.
So if that mistake is corrected, the result for w0 should be just twice of the previous wrong fit.
|
I was off by a factor of sqrt(2). The correct fit parameters are
for the vertical beam profile:
reduced chi^2 = 3.28
x0 = (-87 ± 1) mm
w0 = (32.59 ± 27) µm
for the horizontal beam profile
reduced chi^2 = 2.02
x0 = (-82 ± 1) mm
w0 = (32.23 ± 20) µm
In the following plots * denotes vertical data points and + denotes horizontal data points. The blue curve is the fit to the vertical data and the purple curve is the fit to the horizontal data. |
Attachment 1: profile.png
|
|
Attachment 2: residuals.png
|
|
9442
|
Wed Dec 4 21:41:09 2013 |
ericq | Update | Green Locking | Green PDH Characterization |
My job right now is to characterize the green PDH loops on each arm. Today, Jenne took me around and pointed at the optics and electronics involved. She then showed me how to lock the green beams to the arms (i.e. opening the shutters until you hit a TM00 shape on the transmitted beam camera). Before lunch, the y arm was easiest to lock, and the transmitted power registered at around 0.75.
After lunch, I took a laptop and SR785 down to the y end station. I unhooked the PDH electronics and took a TF of the servo (without its boost engaged, which is how it is currently running) and noise spectrum with the servo input terminated.
I then set up things a la ELOG 8817 to try and measure the OLTF. However, at this point, getting the beam to lock on a TM00 (or something that looked like it) was kind of tough. Also, the transmitted power was quite a bit less than earlier (~0.35ish), and some higher order modes were higher than that (~0.5). Then, when I would turn on the SR785 excitation, lock would be lost shortly into the measurement, and the data that was collected looked like nonsense. Later, Koji noted that intermittent model timeouts were moving the suspensions, thus breaking the lock.
We then tried to lock the x arm green, to little success. Koji came to the conclusion that the green input pointing was not very good, as the TM00 would flash much less brightly than some of the much higher order modes.
Tomorrow, I will measure the x arm OLTF, as it doesn't face the same timeout issue that is affecting the y arm. |
9447
|
Fri Dec 6 12:45:51 2013 |
ericq | Update | Green Locking | Green PDH Characterization |
Yesterday, made a slew of measurements on the X-arm when locked on green. By tweaking the temperature loop offset and the green input PZT pointing, I was able to get the transmitted green to around 1.0. The PDH board gain was set to 4.0. I had trouble making swept sine measurements of the OLTF; changing the excitation amplitude for different frequency ranges would result in discontinuities in the measured TF, and there was only a pretty narrow band around the UGF that seemed to have reasonable coherence.
So, I used the SR785 as a broadband noise generator and measured the TF via dividing the spectra in regions of coherence. Specifically, I used the "pink noise" option of the SR785. I also used a SR560 as a low pass to get enough noise injected into the lower frequency range to be coherent, while not injecting so much into the higher frequencies that the mode hopped while measuring.
The servo board TF was easily fitted to a 4th order zpk model via VFIT, but I'm having trouble fitting the OLTF. (There is a feature in the servo TF that I didn't fit. This is a feature that Zach saw [ELOG 9537], and attributed to op amp instability) Plots follow. Also, while these need to be calibrated to show the real noise spectrum of the cavity motion, I'm attaching the voltage noise spectra of the error and control signals as a check that electronics/PD noise isn't dominating either signal.
 
 
|
10446
|
Wed Sep 3 18:42:43 2014 |
Jenne | Update | LSC | Green PDH box boosts |
From EricQ's simulations reported in elog 10390, we want to transition from ALS comm to DC transmission signals around 500 pm. However, around 100 pm, the DC transmission signals have a sign flip, so we don't want to have the ALS swing that close to the CARM resonance. So. We want to be at about 500 pm, and not touch 100 pm. So, we don't want our peak ALS motion to go beyond ~400 pm. Which means that we need to have less than about 40 pm in-loop RMS, to avoid hitting 400 pm. This is an ALS requirement, but since the analog PDH box is what forces the end laser to follow the arm cavity, and thus give us information about the arm length fluctuations, the PDH residual noise is part of our sensor noise for the full ALS. So, we need to have the PDH in-loop RMS be less than 40 pm, integrated from a few kHz down to at least 30 mHz. Recall that above the ALS UGF (of about 200 Hz), the sensor noise will be suppressed by 1/f, so we should take that into account when we are looking at the PDH error signal, before we calculate the RMS motion.
Q also measured the in-loop error signal with the current Yend PDH box in elog 10430, and it looks like most of the RMS is coming from a few hundred Hz. I designed a hack to the PDH board boost that has a zero at about 2kHz, and a gain of 30 at DC, so that we will win by squishing all that RMS. Also, it shouldn't be too aggressive, so we should be able to leave it on all the time, and still acquire lock of the green laser to the arm, without having to do triggering.
The board schematic is at DCC D1400294. The boost is also called the "integrator stage", although it will no longer be a simple integrator.
EDIT, JCD: This cartoon is not correct for the non-boosted state, doesn't include effect of R16.

|
10448
|
Thu Sep 4 00:56:44 2014 |
Jenne | Update | LSC | Green PDH box boosts |
Okay, went back to the drawing board with Rana and Koji on PDH box stuff.
Currently (at least for the Yend), in the boost OFF state, we have an overall gain of about 50. This is crazy big. Also, the zero in the "transfer function stage" is around 1kHz, however our green cavity pole is (calculated) to be around 20 kHz. Since these are supposed to cancel but they're not, we have a wide weird flat region in our loop TF.
So. I calculated the changes to the TF stage that I'll need so that I have an increase of about 20 in DC gain, kept the pole at the same ~20Hz, but moved the zero way out to 18kHz. I also calculated the changes needed for the integrator stage to make it effective at much higher frequency than it was designed for. Now the pole is at 75 Hz, and the zero will be at 1.6kHz, and the high frequency gain will stay pretty close to the same with and without the boost.
Planned new TF stage:

Planned boost stage (with and without boost activated):

New boost stage only, so you can see the phase:

The schematic, modified to show my planned changes (which I will put in the DCC after I make the changes):

|
10450
|
Thu Sep 4 03:12:55 2014 |
ericq | Update | LSC | Green PDH box boosts |
Jenne made her board modifications, and the measured TF agreed with the design. Alas, the green would not lock to the arm in this state.
I think that the reason is that the new TF does not have nearly as much low frequency gain as the old one, for a given UGF. Thus, for example, the 1Hz noise due to the pendulum resonance, has 30dB less loop gain suppressing it.

NEED MORE 
|