  15264   Tue Mar 10 19:59:09 2020 YehonathanUpdateLoss MeasurementArm transfer function measurement

I want to measure the transfer function of the arm cavities to extract the pole frequencies and get more insight into what is going on with the DC loss measurements.

The idea is to modulate the light using the PSL AOM. Measure the light transmitted from the arm cavities and use the light transferred from the IMC as a reference.

I tried to start measuring the X arm but the transmission PD is connected to the QPD whitening filter board with a 4 pin Lemo for which I couldn't find an adapter.

  • I switch to the Y arm where the transmission PD - Thorlabs PDA520 (250KHz Bandwidth) - is BNC all the way.
  • I lay an 82ft BNC cable from the Y Arm 1Y4 to 1Y1 where the BNC from the IMC Trans PD and an SR785 are found. 
  • I lock the Arm cavities.
  • I connect the AOM cable to the source, the TRY PD (Teed off from the QPD whitening filter) to CH1 and IMC_TRANS to CH2 and measure the transfer function using a swept sine with an offset of 300mV and amplitude of 100mV.
  • I fit it to a low pass filter function - see attachment 1 - but it seems like the fit rails off at 10KHz. 

Could this be because of the PDA520 limited BWs? I tried playing with the PD gain/bandwidth switch but it seems like it was already set to high bandwidth/low gain.

In any case, the extracted pole frequency ~ 2.9kHz implies a finesse > 600 (assuming FSR = 3.9MHz) which is way above the maximal finesse (~ 450) for the arm cavities.

I disconnected the source from the AOM. But left the other two BNCs connected to the SR785. Also, TRY PD is still teed off. Long BNC cable is still on the ground.

Attachment 1: YArmFrequencyResponse.pdf
YArmFrequencyResponse.pdf
  15269   Thu Mar 12 10:43:50 2020 ranaUpdateLoss MeasurementArm transfer function measurement

                               when doing the AM sweeps of cavities

make sure to cross-calibrate the detectors

                       else you'll make of science much frivolities

            much like the U.S. elections electors

  15277   Mon Mar 16 15:23:03 2020 YehonathanUpdateLoss MeasurementArm transfer function measurement

I measured the cross-calibration of the two PDs on the PSL table.

I used the existing flip mounted BS that routes the beam into a PDA255, the same as in the IMC transmission.

I placed a PDA520, the same as the one measuring TRY_OUT on the ETMY table,  on the transmission of the BS (Attachment 1).

I used the SR785 to measure the frequency response of PDA520 with reference to PDA255 (Attachment 2). Indeed, calibration is quite significant.

I calibrated the Y arm frequency response measurement.

However, the data seem to fit well to 1/sqrt(f^2+fp^2) - electric field response - but not to 1/(f^2+fp^2) - intensity response. (Attachment 3).

Also, the extracted fp is 3.8KHz (Finesse ~ 500) in the good fit -> too small.

When I did this measurement for the IMC in the past I fitted the response to 1/sqrt(f^2+fp^2) by mistake but I didn't notice it because I got a pole frequency that was consistent with ringdown measurements.

I also cross calibrated the PDs participating in the IMC measurement but found that the calibration amounted for distortions no bigger than 1db.

Attachment 1: Cross_calibration_setup.jpg
Cross_calibration_setup.jpg
Attachment 2: PDA520overPDA255_Response.pdf
PDA520overPDA255_Response.pdf
Attachment 3: YArmFrequencyResponse.pdf
YArmFrequencyResponse.pdf
  15307   Sat Apr 18 14:57:44 2020 YehonathanUpdateLoss MeasurementArm transfer function measurement

Ok, now I understand my foolishness. It should definitely be 1/sqrt(f^2+fp^2) .

Quote:
However, the data seem to fit well to 1/sqrt(f^2+fp^2) - electric field response - but not to 1/(f^2+fp^2) - intensity response. (Attachment 3).
  15355   Tue May 26 14:32:44 2020 gautamUpdateLSCArm transmission RIN

Summary:

The measured RIN of the arm cavity transmission when the PRFPMI is locked is ~10x in RMS relative to the single arm POX/POY lock. It is not yet clear to me where the excess is coming from.

Details:

Attachment #1 shows the comparison.

  • For the PRFPMI lock, the ITM Oplev Servos are DC coupled, and the ETM QPD ASC servos are also enabled.
  • Admittedly, the PD used in the POX/POY lock case is the Thorlabs PD while when the PRFPMI is locked, it is the QPD.
  • I found that there isn't really a big difference in the RIN if we normalize by the IMC transmission or not (this is what the "un-normalized" in the plot legend is referring to).  A scatter plot of TRX vs TRY and TRX/MCtrans vs TRY/MCtrans have nearly identical principal components. 
  • To convert to RIN, I divided the ocmputed spectra by the mean value of the data stream. For the POX/POY lock, the arm transmission is normalized to 1, so no further manipulation is required.
  • The spectra are truncated to 512 Hz because the IMC sum channel is DQ-ed at 1 kHz, but because of the above bullet point, in principle, I could calculate this out to higher frequencies.
Attachment 1: armRIN.pdf
armRIN.pdf
  15359   Wed May 27 19:36:33 2020 KojiUpdateLSCArm transmission RIN

My speculation for the worse RIN is:

- Unoptimized alignment -> Larger linear coupling of the RIN with the misalignment
- PRC TT misalignment (~3Hz)

Don't can you check the correlation between the POP QPD and the arm RIN?

  15361   Thu May 28 18:36:45 2020 gautamUpdateLSCArm transmission RIN

I agree, I think the PRC excess angular motion, PIT in particular, is a dominant contributor to the RIN. Attachments #1-#3 support this hypothesis. In these plots, "XARM" should really read "COMM" and "YARM" should really read "DIFF", because the error signals from the two end QPDs are mixed to generate the PIT and YAW error signals for these ASC servos - this is some channel renaming that will have to be done on the ASC model. The fact that the scatter plot between these DoFs has some ellipticity probably means the basis transformation isn't exactly right, because if they were truly orthogonal, we would expect them to be uncorrelated?

  • In the corner plots, I am plotting the error signals of the ASC servos and the arm transmission. POP feedback is not engaged, but some feedback control to the ETMs based on the QPD signals is engaged.
  • In the coherence plot, I show the coherence of the ASC error signals with the POP and TR QPD based error signals, under the same conditions. The coherence is high out to ~20 Hz.

I guess what this means is that the stability of the lock could be improved by turning on some POP QPD based feedback control, I'll give it a shot.

Quote:

- PRC TT misalignment (~3Hz)

Don't can you check the correlation between the POP QPD and the arm RIN

Attachment 1: PRFPMIcorner_ASC_PIT_1274419354_1274419654.pdf
PRFPMIcorner_ASC_PIT_1274419354_1274419654.pdf
Attachment 2: PRFPMIcorner_ASC_YAW_1274419354_1274419654.pdf
PRFPMIcorner_ASC_YAW_1274419354_1274419654.pdf
Attachment 3: PRFPMIcorner_ASC_coherence_1274419354_1274419654.pdf
PRFPMIcorner_ASC_coherence_1274419354_1274419654.pdf
  15362   Fri May 29 00:34:57 2020 ranaUpdateLSCArm transmission RIN

how bout corner plot with power signals and oplevs? I think that would show not just linear couplings (like your coherence), but also quadratic couplings (chesire cat grin)devil

  2611   Wed Feb 17 19:36:05 2010 KojiUpdateCOCArm visibility

I have measured the arm visibilities.
I did not see any change since the last wiping. Our vacuum is not contaminating the cavity in the time scale of 2 months.

It is very good.


Arm visibility measurement ~ latest (Feb. 17, 2010)

X Arm: 0.898 +/- 0.003
Y Arm: 0.892 +/- 0.006

Arm visibility measurement after the vent (Dec. 14, 2009)

X Arm: 0.897 +/- 0.005
Y Arm: 0.893 +/- 0.004

Arm visibility measurement before the vent (Nov 10, 2009)

X Arm: 0.875 +/- 0.005
Y Arm:
0.869 +/- 0.006

  15225   Wed Feb 26 17:17:17 2020 YehonathanUpdate Arms DC loss measurements

{Yehonathan, Gautam}

In order to measure the loss in the arm cavities in reflection, we use the DC method described in T1700117.

It was not trivial to find free channels on the LSC rack. The least intrusive way we found was to disconnect the ALS signals DSUB9 (Attachment 1) and connect a DSUB breakout board instead (Attachment 2).

The names of the channels are ALS_BEATY_FINE_I_IN1_DQ for AS reflection and ALS_BEATY_FINE_Q_IN1_DQ for MC transmission. Actually, the script that downloads the data uses these channels exactly...

We misalign the Y arm (both ITM ad ETM) and start a 30 rep measurement of the X arm loss cavity using /scripts/lossmap_scripts/armLoss/measureArmLoss.py and download the data using dlData.py.

We analyze the data. Raw data is shown in attachment 3. There is some drift in the measurement, probably due to drift of the spot on the mirror. We take the data starting from t=400s when the data seems stable (green vertical line). Attachment 5 shows the histogram of the measurement

X Arm cavity RT loss calculated to be 69.4ppm.

We repeat the same procedure for the Y Arm cavity the day after. Raw data is shown in attachment 5, the histogram in attachment 6.

Y Arm cavity RT loss calculated to be 44.8ppm. The previous measurement of Y Arm was ~ 100ppm...

Loss map measurement is in order.

Attachment 1: 20200226_171155.jpg
20200226_171155.jpg
Attachment 2: 20200226_171539.jpg
20200226_171539.jpg
Attachment 3: XArmLossMeasurement_RawData.pdf
XArmLossMeasurement_RawData.pdf
Attachment 4: XArmLossMeasurement_Hist.pdf
XArmLossMeasurement_Hist.pdf
Attachment 5: YArmLossMeasurement_RawData.pdf
YArmLossMeasurement_RawData.pdf
Attachment 6: YArmLossMeasurement_Hist.pdf
YArmLossMeasurement_Hist.pdf
  10558   Wed Oct 1 19:40:46 2014 ericqUpdateLSCArms IR aligned
Summary:
  • Beamsplitter was put into MC refl path.
  • HWP was rotated to maximize power into PMC. 
  • MC autolocker locked, small alignment tweak led to WFS taking over
  • Light present on REFL, AS and POP!
  • After small adjustments to TTs and ETMY, locked Yarm with AS55, ran ASS. 
  • Adjusted AS camera and RFPD alignment for ASS'd AS beam. 
  • Left arm locked on AS55, aligned new POY beam onto POY11. Centered ITMY oplev while I was there. 
  • After adjusting digital POY11 demod angle with an excitation into ETMY, arms were POX/POY locked and ASS'ed.
  • PRM and SRM eyeball aligned

The IFO is ready for 3F DRMI comissioning 

  2605   Tue Feb 16 10:01:16 2010 AlbertoConfigurationLSCArms and PRC not locking

Since last Friday either the arms or the PRC can't lock.

The montors show the beam flashing on the end mirrors, but the cavity can't get locked. The error signal looks fine. I suspect a computer problem.

Also PRC can't lock. SPOB is suspiciously stuck at about -95. Although that's not a fixed number, but covering the by hand the SPOB PD on the ITMY table doesn't change the number. I check the DC output of the photodetector and it is actually seen the beam.

Suspecting computer problems started after last Thursday's IP switch, I rebooted the frame builder, c1dcuepics, c1daqctrl and all the front ends. I then burtrestored to February 1st at 1:00 am.

Before I burtrestored c1iscepics, SPOB had gone back to more typical numbers around 0, as it usually read when PRC wasn't locked.

But burtrestoring c1iscepics, return it to the -95 of earlier.

Burterestoring to other times or dates didn't solve the problems.

  2607   Tue Feb 16 14:10:06 2010 josephb, rob, kojiConfigurationLSCArms and PRC not locking

Quote:

Since last Friday either the arms or the PRC can't lock.

The montors show the beam flashing on the end mirrors, but the cavity can't get locked. The error signal looks fine. I suspect a computer problem.

Also PRC can't lock. SPOB is suspiciously stuck at about -95. Although that's not a fixed number, but covering the by hand the SPOB PD on the ITMY table doesn't change the number. I check the DC output of the photodetector and it is actually seen the beam.

Suspecting computer problems started after last Thursday's IP switch, I rebooted the frame builder, c1dcuepics, c1daqctrl and all the front ends. I then burtrestored to February 1st at 1:00 am.

Before I burtrestored c1iscepics, SPOB had gone back to more typical numbers around 0, as it usually read when PRC wasn't locked.

But burtrestoring c1iscepics, return it to the -95 of earlier.

Burterestoring to other times or dates didn't solve the problems.

 Koji and I started poking around, trying to understand what was going on.  At first, we thought it might be related to a computer error, as it seemed.

Fortunately, Rob stopped by and explained that the boost stage of the filter comes under c1lsc control, and will be turned on or off depending on the power in the arms.  Although if you turn it off, it will remain off, it just if its manually selected on, it may go on or off.

Similarly, the output from the Xarm filter bank to the ETMX  filter input will be turned on or off depending on the power in the arm.

Anyways, the locking trouble turns out to be due to no RF sidebands at 33 MHz.  The output of the Marconi was unplugged.  I don't know who, or why did it, but I've plugged it in for now, so we can lock the arms.  Let us know if you need in unplugged.  Thanks.

  2608   Tue Feb 16 15:25:00 2010 AlbertoConfigurationLSCArms and PRC not locking

 

 shock.jpg

  9213   Mon Oct 7 13:55:26 2013 JenneUpdateLSCArms locked in IR for many hours

Someone left the arms aligned, and the LSC engaged, so the arms have been locked almost continuously for several days hours.  The trend below is for 4 days hours.  What is most impressive to me is that we don't see a big degredation in the transmitted power over this time.

EDIT: Okay, I got excited without paying attention to units.  It was only several hours, which is not too unusual.  Although the lack of transmission degredation is still unusual.  However, this may be due to improved oplevs?  I'm not sure why, but we're not seeing (at least in this plot) the degredation to ~0.7 after an hour or so.

BothArmsLocked3Days_7Oct2013.png

  8974   Tue Aug 6 19:53:15 2013 JenneUpdateLSCArms locked in IR, aligned. IFO at nominal power

[Koji, Manasa, Jenne]

The Y arm was locked in IR, and we saw flashing in the Xarm (Gautam had the Xarm for green work when we began).  I checked IPANG, and the beam was beautifully unclipped, almost perfectly centered on the first out of vacuum mirror.  I aligned the beam onto the QPD.

We then swapped out the MC Y1 that we use at low power, and replace the usual 10% BS, so that we wouldn't crispy-fry MC REFL.  Manasa adjusted the half wave plate after the laser, to maximize the power going toward the PMC.  We relocked the PMC, and see transmission of ~0.84, which is at the high side of what we usually get.  The beam was aligned onto MC REFL and centered on the WFS, and the MC was locked at nominal power.  Koji tweaked up the alignment of the MC, and ran the WFS offset script.  I aligned beam onto POP QPD and POP110 coarsely (using a flashing PRC, not a locked PRM-ITMY cavity, so the alignment should be rechecked).  The arms have both been locked and aligned in IR....the green beams need to be steered to match the current cavity axis. 

The AS beam, as well as REFL and POP, are all coming out of the vacuum nicely unclipped. 

Notes:  When Koji was aligning the SRM to get the SRC cavity roughly aligned (the AS flashes all overlapping), we noticed that there is some major pitch-yaw coupling.  Serious enough that we should be concerned that perhaps some connector is loose, or an actuator isn't working properly.  This should be checked.

Moral of the story:  Coarse alignment of all mirrors is complete after pump-down and we have IR locked and aligned to both arms at nominal power.

 

Still to do:

* Restore PRM, align beam onto the REFL PDs. 

* Lock PRM-ITMY cavity, align beam onto POP PDs.

* Align AS beam onto AS55. 

* Recenter all oplevs.

* Recenter IPPOS and IPPANG at nominal power.

* Start locking!!

  8975   Wed Aug 7 10:09:30 2013 KojiUpdateLSCArms locked in IR, aligned. IFO at nominal power

I have a concern about the SRM suspension. The yaw alignment bias produces huge pitch coupling.

This could be a connector issue or the rubbing of the mirror on the EQ stops.

We have the photos of the magnets and they were not touching the OSEMs.

  9008   Tue Aug 13 21:09:03 2013 manasaUpdateGreen LockingArms ready for ALS

I aligned both the X and Y end green to the arms.

The transmitted green were aligned at the PSL table green optics to the beat PDs.
Beat notes were retrieved.
 
To do:
1. Check Y arm ALS with previous performance.
2. Troubleshoot X arm ALS.
3. Edit the automation scripts for ALS.
4. Modify ALS model to talk to LSC instead of suspension models.
  1233   Fri Jan 16 18:25:32 2009 Yoichi, Kakeru, RanaUpdateLSCArms were unstable
The single arm lock had been unstable for both arms in the past few days.

Symptoms:
When an arm was locked by itself, the transmitted power showed a lot of fluctuations (sharp drops).
The first attachment shows the arm power fluctuations in power spectrum and time series.
References are when the boost filters are off for the arm feedback.
You can see that when the boosts are off, the power fluctuates a lot.
Also it is obvious that X-arm is a lot worse than Y.


Diagnosis:
The second attachment is the comparison of the error signal spectra between boosts on and off.
(PD3_I is the error signal of X-arm, PD4_I is Y arm). References are boost on.
Since the arm power fluctuation was suppressed by the gain increase, it was suspected that the main
reason for the power fluctuation is not alignment fluctuation. Rather, it is length or frequency fluctuation.

Then I took spectra and coherences of PD3_I, PD4_I and MC_F with both arms locked independently.
You can see broadband coherence between PD3_I (Xarm) and MC_F (frequency noise). In contrast the coherence
between PD4_I and MC_F is smaller. This means X-arm is more susceptible to the frequency noise than Y.
What can make a simple Fabry-Perot cavity more susceptible to frequency noise ? An offset ?
So I canceled the X-arm offset at the X-arm filter bank. Bingo ! The arm power fluctuation of X-arm became as small as Y-arm
in the dataviewer.
But what is making this offset ?
After watching the dataviewer screen for a while, the arm power fluctuation became larger again. I had to re-adjust the artificial offset
to minimize the fluctuation. This made me think that the source of the offset must be something to do with alignment.
In this case, clipping of the beam at the PD was very suspicious.
So I checked the centering of the POX and POY PDs. As expected, POX was terribly off-centered.
POY was also not exactly at the center of the plateau of DC output.
After centering those PDs, the large offset in the arm loops went away.
Now the arm powers are stable without artificial offset in the loop filters.
The last attachment shows the comparison of arm power fluctuation before and after the PD centering.
(references are the measurements before the centering).
Attachment 1: TRXY.pdf
TRXY.pdf
Attachment 2: ErrorSignals.pdf
ErrorSignals.pdf
Attachment 3: coherenceBetweenArms.pdf
coherenceBetweenArms.pdf
Attachment 4: ArmPowersAfterPDwasCentered.pdf
ArmPowersAfterPDwasCentered.pdf
  3582   Fri Sep 17 03:32:11 2010 KojiUpdateSUSArrangement of the SUS towers

The day before yesterday, I was cleaning a flow bench in the clean room.

I found that one SOS was standing there. It is the SRM suspension.

I thought of the nice idea:

- The installed PRM is actually the SRM (SRMU04). It is 2nd best SRM but not so diiferent form the best one.
==> Use this as the final SRM

- The SRM tower at the clean room
==> Use this as the final PRM tower.
==> The mirror (SRMU03) will be stored in a cabinet.

- The two SOS towers will be baked soon
==> Use them for the ETMs

This reduces the unnecessary maneuver of the suspension towers.

  3761   Fri Oct 22 15:06:43 2010 JenneUpdateSUSArts and Crafts!

This afternoon I epoxied the guiderod and wire standoff to the new PRM.  I also epoxied the magnets that Suresh picked out to the dumbbell standoffs.  We'll let them all cure over the weekend, and then I'll glue the magnets to the optic on ~Monday.

Notes about the epoxy: 

Previously, we had been using the "AN-1" epoxy, which is gray, with a clear hardener.  Bob recommended we switch to "30-2", which is clear with clear, and has been chosen for use in aLIGO.  Both were vacuum approved, but the 30-2 has gone through ~2 months of testing at the OTF (Optics Test Facility?) over in Downs under vacuum, to check the level of outgassing (or really, non-outgassing).

The 30-2 is less viscous than the AN-1, and it takes less glue to do the same job, so we should keep that in mind when applying the epoxy.  When I put the glue next to the guiderod and standoff, it got wicked along the length of each rod, which is good.  I can't reach the whole length of the rod with my glue applicator because the fixture holding them in place blocks access, so the wicking is pretty handy.

 

I've also added the updated version of my Status Table for the suspensions.

Attachment 1: StatusTable.png
StatusTable.png
  16725   Tue Mar 15 10:45:31 2022 PacoUpdateGeneralAssembled small in-vac optics

[Paco]

This morning I assembled LO3, LO4 and AS3 (all mirrors) onto polaris K1 mounts. The mounts stand as per this elog, on 4.5" posts with 0.5" Al spacers to match the beam heigth of 5.5". I also assembled ASL by adding a 0.14" Al spacer, and finally, recycled two DLC mounts (from the XEND flowbench) and posts to mount the 2 inch diameter beamsplitters BHDBS and AS2 (T=10%). I stored the previous 2" optics in the CVI and lambda optic cases and labeled appropriately.

  3936   Tue Nov 16 23:36:29 2010 Suresh, JenneUpdateSUSAssembly of ETMs

[Jenne, Suresh]

 

The ETM assembly has moved forward a couple of steps.  We have completed the following:

1) Positioning the guide rod and wire stand-off on both the ETMs (5 and 7)

2) The magnets had to be cleaned with an acetone wash as they had touched the plastic Petri-dish (not cleaned for vacuum).

3) The magnets and the Al dumb-bells have been glued together and left to cure in the gluing fixture.

4) The guide-rod and wire stand-offs have also been glued to the optic and left to cure for 24 hrs.

 

 

JD:  As you can see in my nifty status table, we are nearing the end of the suspension story.  

StatusTable.png

We are going to try (but can't guarantee) to get ETMX to Bob for baking by Friday at lunchtime, that way we can re-suspend it on ~Monday, and place it in the chamber.  Then we could potentially begin Green arm locking next week.  Steve has (hopefully!!) ordered the spring plungers for ETMY.  The receiving and baking of the spring plungers is the only current delay that I can foresee, and that only is relevant for one of the optics. 

We (who is going to be in charge of this?) still need to move the SRM OSEMs & cables & connectors to the ITMY chamber from the BS chamber. 

 

 

  15111   Mon Jan 6 15:36:55 2020 JonUpdatePSLAssembly underway for c1psl upgrade

[Jon, Yehonathan]

We've begun assembling the new c1psl Acromag chassis based on Yehonathan's final pin assignments. So far, parts have been gathered and the chassis itself has been assembled.

Yehonathan is currently wiring up the chassis power and Ethernet feedthroughs, following my wiring diagram from previous assemblies. Once the Acromag units are powered, I will help configure them, assign IPs, etc. We will then turn the wiring over to Chub to complete the Acromag to breakout board wiring.

I began setting up the host server, but immediately hit a problem: We seem to have no more memory cards or solid-state drives, despite having two more SuperMicro servers. I ordered enough RAM cards and drives to finish both machines. They will hopefully arrive tomorrow.

  15112   Mon Jan 6 16:07:12 2020 gautamUpdatePSLAssembly underway for c1psl upgrade

RTFE. Where did the spares go?

Quote:

I began setting up the host server, but immediately hit a problem: We seem to have no more memory cards or solid-state drives, despite having two more SuperMicro servers. I ordered enough RAM cards and drives to finish both machines. They will hopefully arrive tomorrow.

  15113   Mon Jan 6 19:05:09 2020 not gautamUpdatePSLAssembly underway for c1psl upgrade

I found them, thanks. After c1psl, there are 4 2GB DIMM cards and 1 SSD left. I moved them into the storage bins with all the other Acromag parts.

Quote:

RTFE. Where did the spares go?

Quote:

I began setting up the host server, but immediately hit a problem: We seem to have no more memory cards or solid-state drives, despite having two more SuperMicro servers. I ordered enough RAM cards and drives to finish both machines. They will hopefully arrive tomorrow.

  15116   Fri Jan 10 19:48:46 2020 yehonathanUpdatePSLAssembly underway for c1psl upgrade

{Yehonathan, Jon}

I finished pre-wiring the PSL chassis. I mounted the Acromags on the DIN rails and labeled them. I checked that they are powered up with the right voltage +24V and that the LEDs behave as expected.

Attachment 1: 20200110_194429.jpg
20200110_194429.jpg
Attachment 2: 20200110_194516_HDR.jpg
20200110_194516_HDR.jpg
  15118   Mon Jan 13 16:05:18 2020 yehonathanUpdatePSLAssembly underway for c1psl upgrade

{Yehonathan, Jon}

I configured the Acromag channels according to the Slow Controls Wiki page.

We started testing the channels. Almost at the beginning we notice that the BIO channels are inverted. High voltage when 0. 0 Voltage when 1. We checked several things:

1. We checked the configuration of the BIOs in the windows machine but nothing pointed to the problem.

2. We isolated one of the BIOs from the DIN rail but the behavior persisted.

3. We checked that the voltages that go into the Acromags are correct.

The next step is to power up an isolated Acromag directly from the power supply. This will tell us if the problem is in the chassis or the EPICs DB.

  15120   Tue Jan 14 17:16:43 2020 yehonathanUpdatePSLAssembly underway for c1psl upgrade

{Yehonathan, Jon}

I isolated a BIO Acromag completely from the chassis and powered it up. The inverted behavior persisted.

Turns out this is normal behavior for the XT1111 model.

For digital outputs, one should XT1121. XT1111 should be used for digital inputs.

Slow machines Wiki page was updated along with other pieces of information.

I replaced the XT1111 Acromags with XT1121 and did some rewiring since the XT1121 cannot get the excitation voltage from the DIN rail.

I added an XT1111 Acromag for the single digital input we have in this system.

  15124   Wed Jan 15 10:12:46 2020 gautamUpdatePSLAssembly underway for c1psl upgrade

I don't think this is an accurate statement. XT1111 modules have sinking digital outputs, while XT1121 modules have sourcing digital outputs. Depending on the requirement, the appropriate units should be used. I believe the XT1111 is the appropriate choice for most of our circuits.

For digital outputs, one should XT1121. XT1111 should be used for digital inputs.

  15127   Wed Jan 15 16:08:40 2020 not gautamUpdatePSLAssembly underway for c1psl upgrade

You're right. We had the right idea before but we got confused about this issue. I changed all the XT1121s to XT1111 and vice versa. We already know which channels are sourcing and which not. Updated the wiring spreadsheet. The chassis seems to work. It's time to pass it over to Chub.

Quote:

I don't think this is an accurate statement. XT1111 modules have sinking digital outputs, while XT1121 modules have sourcing digital outputs. Depending on the requirement, the appropriate units should be used. I believe the XT1111 is the appropriate choice for most of our circuits.

For digital outputs, one should XT1121. XT1111 should be used for digital inputs.

  402   Tue Mar 25 15:56:09 2008 JohnUpdateTreasureAssorted pictures
Some pictures scavenged from the D40.
Attachment 1: D40.pdf
D40.pdf D40.pdf
  15380   Mon Jun 8 11:50:02 2020 HangUpdateBHDAstigmatism and scattering plots

We consider the astigmatism effects of the stock options. The conclusions are:

1. For the AS path, the stock should work fine for the phase-one of BHD, if we could tolerate a few percent MM loss. The window for length adjustment to achieve >99% MM for both s and t is only 1 mm for 1% RoC error (compared to ~ 1 cm in the customized case). 

2. The LO path seemed tricky. As LO3 & LO4 are both significantly curved (RoC<=0.5 m), the non-zero angle of incidence makes the astigmatism quite sever. For the t-plane the nominal MM can be 0.98, yet for the s-plane, the nominal MM is only 0.72. We could move things around to achieve a MM ~ 0.85, which is probably fine for the phase-one implementation but not long term. 

Details:

Attachments 1-3 are for the AS path; 4-6 are for the LO path. 

1 & 4. Marginalized MM distribution for the AS/LO paths. Here we assumed 5 mm positional error and 1% fractional RoC error. Due to the astigmatism, the nominal s-plane MM is only 0.72 for the LO path. 

2 & 5. Scattering plots for the AS/LO paths. We color coded the points as the following: pink: MM>0.99; olive: 0.98<MM<=0.99; grey: MM<=0.98. For the AS path, MM is mostly sensitive to the AS1 RoC and can be adjusted by changing AS1-AS3 distance. For the LO path, the LO3 RoC and LO3-LO4 distance are most critical for the MM. 

3 & 6. Assuming +- 1% AS1 (LO3) fractional RoC error, how much can we compensate for it using AS1-AS3 (LO3-LO4) distance. For the AS path, there exists a ~ 1 mm window where the MM for s and t can simultaneously > 99%. For the LO path, the best we can do is to make s and t both ~ 85%. 

Quote:

Summary

For the initial phase of BHD testing, we recently discussed whether the mode-matching telescopes could be built with 100% stock optics. This would allow the optical system to be assembled more quickly and cheaply at a stage when having ultra-low loss and scattering is less important. I've looked into this possibility and conclude that, yes, we do have a good stock optics option. It in fact achieves comprable performance to our optimized custom-curvature design [ELOG 15357]. I think it is certainly sufficient for the initial phase of BHD testing.

Vendor

It turns out our usual suppliers (e.g., CVI, Edmunds) do not have enough stock options to meet our requirements. This is for two reasons:

  • For sufficient LO1-LO2 (AS1-AS4) Gouy phase separation, we require a very particular ROC range for LO1 (AS1) of 5-6 m (2-3 m).
  • We also require a 2" diameter for the suspended optics, which is a larger size than most vendors stock for curved reflectors (for example, CVI has no stock 2" options).

However I found that Lambda Research Optics carries 1" and 2" super-polished mirror blanks in an impressive variety of stock curvatures. Even more, they're polished to comprable tolerances as I had specificied for the custom low-scatter optics [DCC E2000296]: irregularity < λ/10 PV, 10-5 scratch-dig, ROC tolerance ±0.5%. They can be coated in-house for 1064 nm to our specifications.

From modeling Lambda's stock curvature options, I find it still possible to achieve mode-matching of 99.9% for the AS beam and 98.6% for the LO beam, if the optics are allowed to move ±1" from their current positions. The sensitivity to the optic positions is slightly increased compared to the custom-curvature design (but by < 1.5x). I have not run the stock designs through Hang's full MC corner-plot analysis which also perturbs the ROCs [ELOG 15339]. However for the early BHD testing, the sensitivity is secondary to the goal of having a quick, cheap implementation.

Stock-Part Telescope Designs

The following tables show the best telescope designs using stock curvature options. It assumes the optics are free to move ±1" from their current positions. For comparison, the values from the custom-curvature design are also given in parentheses.

AS Path

The AS relay path is shown in Attachment 1:

  • AS1-AS4 Gouy phase separation: 71°
  • Mode-matching to OMC: 99.9%
Optic ROC (m) Distance from SRM AR (m)
AS1 2.00  (2.80) 0.727  (0.719)
AS2 Flat   (Flat) 1.260  (1.260)
AS3 0.20  (-2.00) 1.864  (1.866)
AS4 0.75  (0.60) 2.578  (2.582)

LO Path

The LO relay path is shown in Attachment 2:

  • LO1-LO2 Gouy phase separation: 67°
  • Mode-matching to OMC: 98.6%
Optic ROC (m) Distance from PR2 AR (m)
LO1 5.00  (6.00) 0.423  (0.403)
LO2 1000 (1000) 2.984  (2.984)
LO3 0.50  (0.75) 4.546  (4.596)
LO4 0.15  (-0.45) 4.912  (4.888)

Ordering Information

I've created a new tab in the BHD procurement spreadsheet ("Stock MM Optics Option") listing the part numbers for the above telescope designs, as well as their fabrication tolerances. The total cost is $2.8k + the cost of the coatings (I'm awaiting a quote from Lambda for the coatings). The good news is that all the curved substrates will receive the same HR/AR coatings, so I believe they can all be done in a single coating run.

 

Attachment 1: AS_MM_hist_stock.pdf
AS_MM_hist_stock.pdf
Attachment 2: AS_MM_t_scat_stock.pdf
AS_MM_t_scat_stock.pdf
Attachment 3: AS_MM_adj_stock.pdf
AS_MM_adj_stock.pdf
Attachment 4: LO_MM_hist_stock.pdf
LO_MM_hist_stock.pdf
Attachment 5: LO_MM_s_scat_stock.pdf
LO_MM_s_scat_stock.pdf
Attachment 6: LO_MM_adj_stock.pdf
LO_MM_adj_stock.pdf
  15381   Mon Jun 8 12:49:07 2020 KojiUpdateBHDAstigmatism and scattering plots

Can you describe the mode matching  in terms of the total MM? Is MM_total = sqrt(MM_vert * MM_horiz)?

  15382   Mon Jun 8 17:40:22 2020 JonUpdateBHDAstigmatism and scattering plots

MM_total = (MM_vert + MM_horiz) / 2. 

The large astigmatic MM loss in the LO case is mainly due to the strong LO4 curvature (R=0.15m) with a 10 deg AOI. I looked again at whether LO1 could be increased from R=5m to the next higher stock value of 7.5m, as this would allow weaker curvatures on LO3 and LO4. However, no, that is not possible---it reduces the LO1-LO2 Gouy phase separation to only 18 deg.

There is, however, a good stock-curvature option if we want to reconsider actuating LO4 instead of LO2 (attachment 1). It achieves 99.2% MM with the OMCs, allowing positions to vary +/-1" from the current design. The LO1-LO4 Gouy phase separation is 72 deg.

Optic ROC (m) Distance from PR2 AR (m)
LO1 10 0.378
LO2 1000 2.984
LO3 10 4.571
LO4 7.5 4.926

Alternatively, we could look at reducing the AOI on LO3 and LO4 (keeping LO1-LO2 actuation).

Attachment 1: LOpathStock2.pdf
LOpathStock2.pdf
  15384   Mon Jun 8 21:45:47 2020 JonUpdateBHDAstigmatism and scattering plots

Hmm? T1300364 suggests MM_total = Sqrt(MM_Vert * MM_Horiz)

  15387   Tue Jun 9 15:02:56 2020 eHangUpdateBHDAstigmatism and scattering plots

Using the updated AOI's for the LO path: (4.8, 47.9, 2.9, 4.5) deg for (LO1, LO2, LO3, LO4), we obtain the following results. 

First two plots are scattering plots for the t and s planes, respectively. Note that here we have changed to 0.5% fractional RoC error and 3 mm positional error. We have also changed the meaning of the colors: pink:MM>0.98; olive 0.95<MM<=0.98, and grey MM<=0.95. It seems that both planes would benefit statistically if we make the LO3-LO4 distance longer by a few mm. 

We also consider how much we could compensate for the MM error in the last plot. We have a few mm window to make both planes better than 0.95. 

Attachment 1: LO_MM_t_scat_stock.pdf
LO_MM_t_scat_stock.pdf
Attachment 2: LO_MM_s_scat_stock.pdf
LO_MM_s_scat_stock.pdf
Attachment 3: LO_MM_adj_stock.pdf
LO_MM_adj_stock.pdf
  4729   Tue May 17 01:05:56 2011 kiwamuUpdateLSCAsymmetry measurement prep : recentering works

I re-centered beams on several PDs and a camera including :

  AS55, ETMY_QPD, TRY and ETMYT_CCD.

 

The most important one was AS55.

When I was locking each arm I found that the error signal from AS55 was very coupled to the angular motion of the arms.

I checked the beam on the AS55 RFPD and found the beam on the edge of the photo diode. This is possibly because Valera and I had been touching the input beam alignment.

At that time the DC signal from AS55 without aligning PRM and SRM was about 5 mV.

Adjusting the beam position by a steering mirror brought the DC signal up to 20 mV.

Then the lock of each arm became more stable.

  9774   Wed Apr 2 01:18:30 2014 JenneUpdateLSCAttempt at PRMI+2 arms

I was trying to lock PRMI+2 arms, but I'm losing patience with the MC losing lock.  It's mostly well-behaved, but every now and again it'll lose lock, and it always seems to be just when I've gotten to a delicate part.  Anyhow.  I don't think anything needs fixing.

I am not able today to acquire PRMI lock with REFL 165 I&Q, nor am I able to follow Koji's prescription to transition to 165 from 55.  However, I am able to transition to, or just straight-up aquire on, REFL 33 I&Q.  The new ASC is awesome.

Before trying to lock with REFL165, I redid it's demod phase, by actuating on the PRM while locked on REFL 55, and minimizing the PRCL signal in the Q-phase.  Old 165 phase was -83.5 degrees, new is -79.5 degrees.

I then tried the procedure of misaligning the PRM, acquiring ALS lock of both arms, finding the arm IR resonances, and moving the arms off resonance.  Then I restored the PRM, and locked the PRMI on sidebands using REFL33 I&Q. 

Something was a little weird and unexpected:  If the arms were not far, far off resonance, there was a large MICH offset, so that AS was bright, and POP was pretty dark.  If I moved the arms farther from resonance, POP would come back to the "normal" brightness, which was ~460 counts on POP110I.  When POP was dark-ish, POP110I was about 150, although this number could be changed by moving the arms around.  This number was not dependent on PRM alignment.  Also, PRCL was not yet starting to resonate the carrier, because POPDC stayed at its low sideband-lock level of about 90 counts (vs. 2,000+ for a PRMI-only carrier lock), and POP was visually dark on the camera. 

---------------------------------

While playing with PRMI + 2 ALS arms is entertaining for the evening, I don't yet have a plan for dealing with the changing CARM optical plant for IR signals situation.  That's in progress in the daytime.

  9780   Thu Apr 3 00:30:52 2014 JenneUpdateLSCAttempt at PRMI+2 arms

[EricQ, Jenne]

We started out this evening by locking the PRMI, on different REFL PDs, just to make sure that we could.  We were able to acquire lock (without having to transition) on either REFL55, REFL33 or REFL165 (I&Q phases for each).  By looking at the transfer function between REFL 55 I and REFL 165 I, I determined that the phase of REFL165 needed to be -135.5, not +44.5, so that the gains were the same sign in all REFL PDs (this is in reference to Koji's elog 9777).  The time to acquisition is much shorter with REFL55 than with the other 2 photodiodes.  I'm not sure right now why this is, but it's pretty consistent, and even more so when the arms are held off resonance.  It is also easy to acquire lock with REFL 55 and then transition to either of the 3f diodes.

PRMI settings:

MICH gain = 2.0.  FMs 4, 5 always on.  FMs 2, 3, 6, 7, 9 triggered with 35 up, 2 down.  Trigger servo on POP110I with 100 up, 10 down.

PRCL gain = -0.020.  FMs 4, 5 always on.  FMs 2, 3, 6, 9 triggered with 35 up, 2 down.  Trigger servo on POP110I with 100 up, 10 down.

PRCL ASC triggered with 50 up, 10 down.  Both pitch and yaw servos had FMs 1, 9 always on, and the FM 6 boost turned on by hand after lock acquired.  Pitch gain = -0.023, yaw gain = -0.027.

If using REFL55, PRCL = I = 1 in the input matrix, and MICH = Q = 1 in the input matrix.

If using REFL33, PRCL = I = 3 in the input matrix, and MICH = Q = 3 in the input matrix.

If using REFL165, PRCL = I = 0.15 in the input matrix, and MICH = Q = 0.1 in the input matrix.


We then moved on to trying to do PRMI + 2 arms, but have been plagued a little bit by locklosses, which may be due to the high seismic from the few large and many small Chilean aftershocks. 

Settings:  With the PRM misaligned, we acquired ALS lock in a CARM/DARM fashion.  The Xarm servo was our "darm" proxy, with +1*ALSX and +1*ALSY.  The Yarm servo was our "carm" proxy, with -1*ALSX and +1*ALSY.  The opposite signs from what you might expect is from our having placed the 2 aux laser frequencies on opposite sides of the PSL.  Our DARM (xarm) was actuating +1 on ETMX and -1 on ETMY.  Our CARM (yarm) was actuating +1 on MC2.  Then we put in a CARM offset of ~60 counts.

We then realigned the PRM, and locked the PRMI (settings as above).  It is much easier to acquire lock with REFL55 than it is with REFL33 or REFL165.  Also, when we are locking the PRMI with REFL55, the AS port is dark, and we see bright sideband resonance at the POP port, as we normally expect.  However, as with last night, when we lock the PRMI with either of the 3f PDs, we see a very bright AS port, and a dark POP port.  Tonight, putting in a MICH offset did not seem to make a significant difference.  As with last night, moving the arms farther away from resonance removed this MICH offset.  I am sure that this is not an artifact of the photodiode dark offsets not being set properly, since I rechecked those carefully. 

We have not come to any interesting conclusions about PRMI+2 arms tonight, since we have started losing the MC every few minutes (maybe seismic-related?). 

  9781   Thu Apr 3 03:06:34 2014 JenneUpdateLSCAttempt at PRMI+2 arms

[EricQ, Jenne]

Much more success later! 

We've had the arms locked on ALS and held off resonance for more than 2 hours now.  That's good.  We've done several trials of locking the PRMI and trying to reduce the ALS CARM offset.  Once we were able to get quite close, but we never achieved zero CARM offset. 

One big finding is that when the TRX and TRY are about 0.1 in the coupled-cavity case, we start to see real length information in the 1/sqrt(trans) signals.  Q will edit this elog, or reply to it, with the data that he has collected.

  9783   Thu Apr 3 18:09:54 2014 ericqUpdateLSCAttempt at PRMI+2 arms

So, here's the basic: "We reduced the CARM offset and saw more TRY" plot. 

offsetTRY.pdf

 

As Jenne mentioned, we suspected that we were seeing real displacement information in the sqrtInv signals. (We had incidentally hard switched to the transmon QPDs for all of this)

Here's a 2d-histogram of the ALS CARM error signal vs. the sqrtInv CARM signal (i.e. 1/sqrt(TRX) + 1/sqrt(TRY))

 

2dhist.pdf

This is exactly the shape we expect, which is cool. You can see where we stepped the offsets, too. It looks like the signal gets into it's good linear range when ALS CARM was about -20, which is when TRY was a little under 0.1, which seems pretty early and potentially useful. 

Also, here are snapshots of what REFL11_I and sqrtInv CARM were doing in the last five seconds of time in the above plot, which was shortly before we made the offset push that broke the PRMI lock. If you look really closely, maybe you can convince yourself that there is some common information in them...? It's hard to say. In any case, there is definitely CARM pdh action happening.

pdh_trans.pdf

  6736   Fri Jun 1 02:13:00 2012 JenneUpdateGreen LockingAttempt at Ygreen beat - failed

[Yuta, Jenne]

We tried to find the Ygreen beat note, with no success yet.  We calculate from Bryan's formula that the Yend laser should be ~34.68C.  But Katrin has an elog saying that she was looking around 19C.  I don't know why the discrepancy, but maybe this is part of our problem?  Kiwamu elog-responded that the epics output had to be high (~9V) when the temp was 19C.  So maybe we need a smaller offset setting in the slow servo with the 34C temperature?

We set the "T+" on the Ygreen laser controller to 34.68C using the dial, and then tried a few large steps with the offset in the Ygreen slow servo.  The idea was to see if we could swing past the beat, so we would know vaguely where it was.  But we never saw a resonance on the spectrum analyzer, even with a "hold max" trace. 

We confirmed that there is signal going to the SLOW input of the laser controller's front panel.  Yuta watched a voltmeter while I changed the epics value, and we successfully changed the signal.  However, after plugging the SLOW cable back in, we noticed that no matter what we set the epics value to, we don't see any temperature change reported on the front panel display.  There is something in the manual( according to Katrin) that the "LT" display is not accurate when a cable is plugged in.  But none of the display values changed.  I think there is a measured temp output on the back that Bryan mentioned that we could use to see if something is really changing inside.

Anyhow, no beatnote found yet tonight.  We confirmed before starting that the alignment onto the beat PD was good, so that's not the problem.

  9821   Thu Apr 17 01:18:34 2014 JenneUpdateLSCAttempt at handing CARM to REFL11

[Jenne, Koji]

This evening, Koji and I followed the procedure from last night (elog 9817), with the exceptions that as we saw gain peaking in the DARM spectrum, we lowered the DARM servo gain.  We also left the DARM FM4 boost off, and added (TRX+TRY) power normalization to AS55 (although we still had to hand-reduce the gain).    These changes enabled us to reduce the CARM offset much further.  We were able to get the transmitted powers to hold steady at about 1 count while on the IR signals, which is a new record for us.  (We had in the past held the arms with ALS at several counts, but the power fluctuations were huge, and now they are nice and small).

After that, we started looking at whether we could transition CARM over to REFL11I.  We tried a few times, but never made it all the way.


Here are some times for data-foraging tomorrow:

8:27pm, nice transition, CARM offset reduction to 0.6 before lockloss.

9:19pm, turned on power normalization for AS55Q, then reduced CARM offset to 0.5

9:40pm, Lockloss after reducing CARM offset to -0.24, arm transmitted powers around 0.9.

gps 1081748419: First trial trying to transition CARM to REFL11I normalized by (TRX+TRY).

gps 1081749965:  Tried to transition CARM to (REFL11 + REFL33)/(TRX+TRY).  Got about 1/3 of the way through the transition (in terms of matrix element value steps) before lockloss.

11:56pm, Tried to add in REFL11I to CARM error signal (without reducing 1/sqrt(trans) matrix elements).  We increased the REFL11 matrix element until we saw gain peaking, and then tried reducing the 1/sqrt(trans) contribution, and lost lock.  We were only at an offset of 0.3, so we probably weren't close enough to the resonance yet.  We were able to add in REFL11 information, but this was probably not too hard, since there wasn't much actual information in it.


Thoughts:

* It's a little weird that once we are on IR signals, the 0 CARM offset point that we find with ALS is not the true CARM offset point.  Although, this may be because we're just going to an averaged no CARM offset place with ALS, but since ALS is noisy, we won't ever really be holding on the zero offset point.  Anyhow, when we were using the 1/sqrt(trans) signals for CARM, and the CARM digital offset was -0.24, the ALSX and ALSY outputs were both about 0.5 in magnitude.

* We're getting there! 

  9829   Fri Apr 18 12:53:54 2014 JenneUpdateLSCAttempt at handing CARM to REFL11: Time series

Some time series data from Wednesday night. 

Here is the first time we've gotten the arm transmissions to about 1 count, while holding CARM and DARM on IR signals, so the transmission, as well as POPDC, were relatively quiet.

CARMin1_POPDC_TRX_1000sec_TRXwas1ct.png

As we were attempting to transition CARM to REFL11I, at least 2 of the times, we were hitting a CARM oscillation:

lockloss_CARMoscillating.png

lockloss_CARMoscillating_2.png

  897   Fri Aug 29 11:01:49 2008 josephbConfigurationComputersAttempt to change a channel gain in ICS-110B
As noted earlier by Rana, I was playing around with the /cvs/cds/caltech/chans/daq/C1IOOF.ini file with help from Rob. I had made a backup before hand and saved it as C1IOOF.ini.Aug-28-2008. (I have since been informed that C1IOOF.ini.082808 would have been prefered as a name).

We had been trying to up the gain in the C1: PSL-ISS_INMONPD_F in order to do a very low power PMC sweep, in an attempt to get clean modes for fitting. Initially we pressed the reconfig button on the C0DAQ_DETAIL screen, but all that seemed to do was change the Config File CRC. We proceeded to reboot fb40m remotely. However, any change to the ini file (even an extra space at the end of the file) caused a 0x2000 status for C1IOVME16k on the C0DAQ_DETAIL screen. At the time I presumed it was comparing the CRC of the ini-file to something else.

Digging around on in Alex's webspace at http://www.ligo.caltech.edu/~aivanov/ , I found the NDS Access page, which indicated that 0x2000 was a conflict between the front-end and frame builder .ini files.

"There is also status bit 0x2000 which gets added when the DCU configuration is different in front-end and frame builder. That is you can change and .ini file an then reload DAQ configuration with Epics button, which reconfigures the front-end, but leaves frame builders with invalid old configuration. They will detect this change and set the status to 0x2000 to indicate this condition. You will have to restart frame builders to pick up new .ini file and set status back to zero for the affected DCU."

It was when I was going to try reseting the c1iovme via the C0DAQ_RFMNETOWRK medm screen that we realized the EPICS controls were not responding properly. The .ini file was returned to its original form, and mass reboots commenced.
  8654   Thu May 30 10:40:59 2013 JamieConfigurationCDSAttempt to cleanup c1ioo ADC connections

I have attempted to reconcile all of the ADC connections to c1ioo.  Upon close inspection, it appears that there was a lot of legacy stuff hanging around.  Either that or things have not been properly connected.

The c1ioo front end machine has two ADC cards, ADC0 and ADC1, which are used by two models, c1ioo and c1als.  The CURRENT ADC connections are listed in the table below.  The yellow cells indicate connections that were moved.  The red cells indicate connections that were removed/unplugged:

  channel block connection channel usage  model
ADC0 8-15 MC WFS1 interface   MC WFS1 c1ioo
16-23 MC WFS2 interface   MC WFS2 c1ioo
0-7

generic interface card (2 pin lemo)

0    
1    
2    
3 ALS TRX c1als
4 ALS TRY c1als
5    
6 MCL c1ioo
7 MCF c1ioo

 

  channel block connection channel usage model
ADC1 0-31 1U interface board 0/1 (J1A) PSL FSS MIXER/NPRO c1ioo
2/3 (J2) ALS BEAT X/Y DC c1als
4/5 (J3) PSL eurocrate DAQ interface J4  
6/7 PSL eurocrate DAQ interface J5  
8/9 PSL eurocrate DAQ interface J6  
10/11 MC eurocrate DAQ interface J1  
12/13 MC servo board DAQ  
14/15 (J8)    
16/17 (J9A) UNLABELLED ("DAQ ISS1"???)  
18/19 (J10) "DAQ ISS2"  
20/21 "DAQ ISS3"  
22/23 ALS BEAT X I/Q c1als
24/25 ALS BEAT Y I/Q c1als
26/27    
28/29    
30/31 (J16)    

The following changes were made:

  • "MC L" had been connected to ADC_0_0, moved to ADC_0_6
  • "MC F" had been connected to ADC_0_6, moved to ADC_0_7

The c1ioo model was rebuilt/restarted to reflect this change.

The PSL-FSS_MIXER and PSL-FSS_NPRO connections were broken in the c1ioo so I fixed them when I moved the MC channels.

All the removed connections from ADC1 were not used by any of the front end models, which is why I unplugged them.  Except for the MC DAQ interface J1 and MC servo DAQ connections, I left all other cables plugged in to wherever they were coming from.  The MC cables I did fully remove.

I don't know what these connections were meant for.  Presumably they expose they expose some useful DAQ channels that we're now getting elsewhere, but I'm not sure.  We don't currently have an ISS, which is presumably why the cables labelled "ISS" are not going anywhere.

TODO

I would like to see some more 4-pin lemo --> double BNC cables made.  That would allow us to more easily use the ADC1 generic interface board:

  • Moved ALS TRX/Y to ADC1, so that we can keep all the ALS connections together in ADC1.
  • POP QPD X/Y/SUM

We should also figure out if we're sub-optimally using the various "DAQ" connections to the DAQ cable connectiosn to the eurocrate DAQ interface cards and servo boards.

  922   Thu Sep 4 11:33:25 2008 josephb, Eric, JenneConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110B
We were attempting to increase the gain on the channel C1:PSL-ISS_INMONPD_F in preparation to do a scan of the PMC at very low input power.

We started by adding a line to the C1:IOOF.ini file in /cvs/cds/caltech/chans/daq/ under that channel that said "gain=10.0". Before touching anything, the channel was outputting around 4000 counts.

We hit the reconfig button for c1iovme16k, then rebooted c1iovme (which turned out to do nothing) and then the framebuilder, in a method consistent with the wiki. This turned out to put the channel in an odd state, where it was showing very rapid, random spikes, virtually but still around 4000ish counts. We returned the file back to its original format, hit reconfig, and then rebooted the framebuilder. The channel however, was still behaving in the same broken way.

After poking around the PSL table, looking at some direct outputs, we came back and rebooted c1iovme and the framebuilder again, which fixed the channel, such that it was reading out correctly. Taking this as a sign that maybe we should reboot the framebuilder, then c1iovme to get the channel to load changes, we changed the file again to have "gain=10.0". Upon reboot of the framebuilder, the channel was still reading out fine, but at the same level. So we continued with the reboot of c1iovme. This still had no effect on the channel output.

The ini file has been set back at this point, however since Yoichi is working, I'm holding off doing a reconfig and reboot on the framebuilder until later.
  925   Thu Sep 4 16:24:56 2008 ranaConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110B

Quote:
We were attempting to increase the gain on the channel C1:PSL-ISS_INMONPD_F in preparation to do a scan of the PMC at very low input power.

According to the Wikipedia, certain esoteric mathematical
operations lead to the result that 4000 x 10 > 32768.
  11394   Tue Jul 7 23:26:19 2015 KojiUpdateCDSAttempt to list CDS issues

As Jamie succeded to realize somewhat workable condition of the 40m CDS, I tried to list the obvious CDS issues so that we can attack them one by one.

  1. c1cal is constantly time-outing now (t>60usec). c1sus is close to it (t=56~57us)
  2. We should check the trends of the CPU meters ("C1:FEC-**_CPU_METER"). In fact this should be listed in the summary pages in a new CDS tab.
  3. Probably this is related to 1): c1lsc is constantly showing IPC error (bit0 = shmem). C1LSC_IPC_STATUS.adl is telling that this is coming from the IPC error between c1lsc and c1cal. ("C1:CAL-LSC_SENSMAT_OSC_****"). This information is found by opning C1LSC_GDS_TP.adl screen and click RT NET STAT button next to the IPC error status.
  4. We wonder how the RFM access is accelerated or decelerated by this upgrade.
  5. We need tests to see if the time delays of the models/IPCs are still reasonable.
  6. LSC Overviw screen has a small digest of the CDS status. Now there are many white boxes that correspond to the channels "C1:FEC-**_DIAG1".
  7. All realtime systems have default (0 or 1) epics channel values (i.e. gains, FM switches, matrices, etc). Need burtrestores.
  8. I tried to burtrestore the models but burtgooey indicated there are some errors.
  9. Detailed check of the snapshot files comparing snapshot files in /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2015/Jul/7/19:07 and /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2015/Jun/1/19:07 :
    • c1alsepics shows bunch of volatile channels to be snapshot. It seems that all of the static epics channels are missing in the snapshot file. Is this related to the current omission of the slow data acquisition? => No actually this must be the modification of the ALS model to accommodate the ALS in the LSC model for the new ALS setup.
    • c1lscepics was checked indeed slow channels were properly snapshot. So what was the problem in burting???
    • I made a simple csh script to restore the snapshots one by one while collecting the error messages.
      This script is located as /users/koji/150707/burtrevert.sh
    • #!/bin/csh
      echo 'This script restores all of the snapshot files found in' $argv[1] '.'
      echo 'Are you sure? y/n'

      set ans = $<

      set ANS = `echo $ans | tr "[:upper:]" "[:lower:]" `
      if ($ANS == y) then
          foreach fname ($argv[1]/*epics.snap)
          echo ''
          echo '#################################'
          echo $fname
          echo '#################################'

              burtwb -f $fname
          end
      else
          echo "exiting..."
      endif
       
    •  Now I ran the command
      ./burtrevert.sh /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2015/Jun/1/19:07 &>burt.log
      This lists up the missing channels. The zipped log is attached to this entry.
    • Burting old snapshot always crashes the RT process "c1sus" (not the c1sus host). If I use the newly generated snapshot today,
      the process does not crash. The process halts at the cycle time of 74us (>60us). I left the process crashed so that we can take a new snapshot with the matrix numbers filled. Once we have the correct snapshot, we don't need to worry about this crash. Let's see.
    • c1sus still crashes with the new burt file. Theremust be a trigeer that makes the model frozen. We need to split the burtfile into pieces
      to figure out which line causes the halt.
Attachment 1: burt.log.zip