Fri Jan 5 17:50:47 2018 |
rana | Configuration | Computers | motif on nodus |
I had to do 'sudo yum install motif' on nodus so that we could get libXm.so.4 so that we could run MEDM. Works now. |
13539
|
Fri Jan 12 12:31:04 2018 |
gautam | Configuration | Computers | sendmail troubles on nodus |
I'm having trouble getting the sendmail service going on nodus since the Christmas day power failure - for some reason, it seems like the mail server that sendmail uses to send out emails on nodus (mx1.caltech.iphmx.com, IP=68.232.148.132) is on a blacklist! Not sure how exactly to go about remedying this.
Running sudo systemctl status sendmail.service -l also shows a bunch of suspicious lines:
Jan 12 10:15:27 nodus.ligo.caltech.edu sendmail[6958]: STARTTLS=client, relay=cluster6a.us.messagelabs.com., version=TLSv1/SSLv3, verify=FAIL, cipher=DHE-RSA-AES256-GCM-SHA384, bits=256/256
Jan 12 10:15:45 nodus.ligo.caltech.edu sendmail[6958]: w0A7QThE032091: to=<umakant.rapol@iiserpune.ac.in>, ctladdr=<controls@nodus.ligo.caltech.edu> (1001/1001), delay=2+10:49:16, xdelay=00:00:39, mailer=esmtp, pri=5432408, relay=cluster6a.us.messagelabs.com. [216.82.251.230], dsn=4.0.0, stat=Deferred: 421 Service Temporarily Unavailable
Jan 12 11:15:23 nodus.ligo.caltech.edu sendmail[10334]: STARTTLS=client, relay=cluster6a.us.messagelabs.com., version=TLSv1/SSLv3, verify=FAIL, cipher=DHE-RSA-AES256-GCM-SHA384, bits=256/256
Jan 12 11:15:31 nodus.ligo.caltech.edu sendmail[10334]: w0A7QThE032091: to=<umakant.rapol@iiserpune.ac.in>, ctladdr=<controls@nodus.ligo.caltech.edu> (1001/1001), delay=2+11:49:02, xdelay=00:00:27, mailer=esmtp, pri=5522408, relay=cluster6a.us.messagelabs.com. [216.82.251.230], dsn=4.0.0, stat=Deferred: 421 Service Temporarily Unavailable
Jan 12 12:15:25 nodus.ligo.caltech.edu sendmail[13747]: STARTTLS=client, relay=cluster6a.us.messagelabs.com., version=TLSv1/SSLv3, verify=FAIL, cipher=DHE-RSA-AES256-GCM-SHA384, bits=256/256
Jan 12 12:15:42 nodus.ligo.caltech.edu sendmail[13747]: w0A7QThE032091: to=<umakant.rapol@iiserpune.ac.in>, ctladdr=<controls@nodus.ligo.caltech.edu> (1001/1001), delay=2+12:49:13, xdelay=00:00:33, mailer=esmtp, pri=5612408, relay=cluster6a.us.messagelabs.com. [216.82.251.230], dsn=4.0.0, stat=Deferred: 421 Service Temporarily Unavailable
Why is nodus attempting to email umakant.rapol@iiserpune.ac.in? |
13540
|
Fri Jan 12 16:01:27 2018 |
Koji | Configuration | Computers | sendmail troubles on nodus |
I personally don't like the idea of having sendmail (or something similar like postfix) on a personal server as it requires a lot of maintenance cost (like security update, configuration, etc). If we can use external mail service (like gmail) via gmail API on python, that would easy our worry, I thought. |
13542
|
Fri Jan 12 18:22:09 2018 |
gautam | Configuration | Computers | sendmail troubles on nodus |
Okay I will port awade's python mailer stuff for this purpose.
gautam 14Jan2018 1730: Python mailer has been implemented: see here for the files. On shared drive, the files are at /opt/rtcds/caltech/c1/scripts/general/pizza/pythonMailer/
gautam 11Feb2018 1730: The python mailer had never once worked successfully in automatically sending the message. I realized this may be because I had put the script on the root user's crontab, but had setup the authentication keyring with the password for the mailer on the controls user. So I have now setup a controls user crontab, which for now just runs the pizza mailing. let's see if this works next Sunday...
Quote: |
I personally don't like the idea of having sendmail (or something similar like postfix) on a personal server as it requires a lot of maintenance cost (like security update, configuration, etc). If we can use external mail service (like gmail) via gmail API on python, that would easy our worry, I thought.
|
|
13545
|
Sat Jan 13 02:36:51 2018 |
rana | Configuration | Computers | sendmail troubles on nodus |
I think sendmail is required on nodus since that's how the dokuwiki works. That's why the dokuwiki was trying to send an email to Umakant. |
13546
|
Sat Jan 13 03:20:55 2018 |
Koji | Configuration | Computers | sendmail troubles on nodus |
I know it, and I don't like it. DokuWiki seems to allow us to use an external server for notification emails. That would be the way to go. |
13681
|
Tue Mar 13 20:03:16 2018 |
johannes | Configuration | Computers | c1auxex replacement |
I assembled the rack-mount server that will long-term replace c1auxex, so we can return the borrowed unit to Larry.
SUPERMICRO SYS-5017A-EP Specs:
- Intel Atom N2800 (2 cores, 1.8GHz, 1MB, 64-bit)
- 4GB (2x2GB) DDR3 RAM
- 128 GB SSD

I installed a standard Debian Jessie distribution, with option LXDE for minimal resource usage. Steps taken after fresh install
- Give controls sudo permission: usermod -aG sudo controls
- mkdir /cvs/cds
- apt-get install nfs-common
- Added line "chiara:/home/cds /cvs/cds nfs rw,bg,nfsvers=3" to end of /etc/fstab
- Configured network adapter in /etc/network/interfaces
iface eth0 inet static
address 192.168.113.48
netmask 255.255.255.0
gateway 192.168.113.2
dns-nameservers 192.168.113.104 131.215.125.1 131.215.139.100
dns-search martian
I first assigned the IP 192.168.113.59 of the original c1auxex, but for some reason my ssh connections kept failing mid-session. After I switched to a different IP the disruption no longer happened.
- Add lines "search martian" and "nameserver 192.168.113.104" to /etc/resolv.conf
- apt-get install openssh-server
At this point the unit was ready for remote connections on the martian network, and I moved it to the XEND.
- Added lines to /home/controls/.bashrc to set paths and environment variables:
export PATH=/cvs/cds/rtapps/epics-3.14.12.2_long/base/bin/linux-x86_64:/cvs/cds/rtapps/epics-3.14.12.2_long/extensions/bin/linux-x86_64:$PATH
export HOST_ARCH=linux-x86_64
export EPICS_HOST_ARCH=linux-x86_64
export RPN_DEFNS=~/.defns.rpn
export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:/cvs/cds/rtapps/epics-3.14.12.2_long/base/lib/linux-x86_64:/cvs/cds/rtapps/epics-3.14.12.2_long/modules/modbus/lib/linux-x86_64/:/cvs/cds/rtapps/epics-3.14.12.2_long/modules/asyn/lib/linux-x86_64
apt-get install libmotif-common libmotif4 libxp6 ( required to run burtwb utility)
The server is ready to take over for c1auxex2 and does not need any local epics compiled, since it can run the 3.14.12.2_long binaries in /cvs/cds. |
Attachment 1: IMG_20180313_105154890.jpg
|
|
Attachment 2: IMG_20180313_133031002.jpg
|
|
13682
|
Wed Mar 14 23:58:30 2018 |
johannes | Configuration | Computers | c1auxex replacement |
I replaced the borrowed server with the permanent one today. Before Removing the current server, Before, I performed several additional preparations:
- Updated Chiara hostables to IP 192.168.113.48 for c1auxex
apt-get install procserv
- copied ETMXaux2.* files in /cvs/cds/caltech/target/c1auxex2 to ETMXaux.* and changed references from /opt/rtcds/epics (which was a local directory on c1auxex2) to /cvs/cds/rtapps/epics-3.14.12.2_long in the copied files
- Added instruction
Environment="LD_LIBRARY_PATH=/cvs/cds/rtapps/epics-3.14.12.2_long/base/lib/linux-x86_64:/cvs/cds/rtapps/epics-3.14.12.2_long/modules/modbus/lib/linux-x86_64/:/cvs/cds/rtapps/epics-3.14.12.2_long/modules/asyn/lib/linux-x86_64"
to /etc/systemd/system/modbusIOC.service (required for burtwb dependencies)
Then I replaced the server:
- IFO was in LSC mode with both arms locked
- Backed up ETMX alignment using save feature in IFOalign screen
- Disengaged LSC mode
- Shut down ETMX watchdog
- Disconnected ETMX satellite box
- Shut down c1auxex2 and c1auxex
- Performed the server swap
- Booted c1auxex
- Made sure EPICS channels were back online and channel defaults were restored
- Reconnected satellite box
- Turned on watchdog
- Turned on OpLevs
- Engaged LSC mode -> both arms were instantly locked
I returned c1auxex2 to Larry, who needed it back asap because of some hardware failure
Steve: Acromag XT1221 ordered 3-15-18 |
13683
|
Thu Mar 15 16:00:25 2018 |
Larry Wallace | Summary | Computers | Cert renewal for NODUS |
The cert for nodus has been renewed for another 2 years.
The following is the basic procedure for getting a new cert: (Note certs are only good for two years as of 2018)
openssl req -sha256 -nodes -newkey rsa:2048 -keyout nodus.ligo.caltech.edu.key -out nodus.ligo.caltech.edu.csr
Country Name (2 letter code) [AU]:US
State or Province Name (full name) [Some-State]:CaliforniaLocality Name (eg, city) []:Pasadena
Organization Name (eg, company) [Internet Widgits Pty Ltd]:California Institute of Technology
Organizational Unit Name (eg, section) []:LIGO
Common Name (eg, YOUR name) []:nodus.ligo.caltech.edu
Leave the e-mail address, challenge password and optional company name blank. A new private key will be generated.
chown root nodus.ligo.caltech.edu.key
chgrp root nodus.ligo.caltech.edu.key
chmod 0600 nodus.ligo.caltech.edu.key
The nodus.ligo.caltech.edu.csr file is what is sent in for the cert.
This file should be sent to either ryan@ligo.caltech.edu or security@caltech.edu and copy wallace_l@ligo.caltech.edu.
A URL llink with the new cert to be downloaded will be sent to the requestor.
Once the files are downloaded, the new cert and intermediate cert, they can be copied and renamed.
The PEM-encoded host certificate by itself is saved at:
/etc/httpd/ssl/nodus.ligo.caltech.edu.crt
The nodus.ligo.caltech.edu.key file should be in the same directory or whichever directory is indicated in the ssl.conf located in /etc/httpd/conf.d/ directory.
httpd will need to be restarted in order for it to see the new cert.
|
13687
|
Mon Mar 19 14:39:09 2018 |
johannes | Configuration | Computers | c1auxex replacement |
[gautam, johannes]
The temperature control output channel for the XEND seismometer wasn't working properly. The EPICS channel existed, could be written to and read from, but no physical voltage was observed on the (confirmed properly) wired connector.
The Acromag DAC that outputs this channel was completely spare in the original scheme and does not serve any other channels at the moment. We found it to be unresponsive to ping from the host machine (reminder: the Acromags are on their own subnet with IPs 192.168.114.xxx connected to the secondary ethernet adapter of c1auxex), while all others returned the ping just fine. The modules have daisy-chained ethernet connections, and the one Acromag unit behind the unresponsive one in the chain was still responding to ping and its channels were working, so it couldn't have been a problem with the (ethernet) cabling.
Gautam and I power-cycled the chassis and server, which resolved the issue. The channel is now outputting the requested voltage on the Out1 BNC connector of the chassis (front). When I was setting up the whole system and did frequent rebooting and IP-redefinitions I have seen network issues arise between server and Acromags. In particular, when changing the network settings server-side, the Acromags needed to reboot occasionally. So this whole problem was probably due to the recent server-swap, as the chassis had not been power-cycled since.
During the debugging we also found that the c1psl2 channels were not working. This was because I had overlooked to update the epics environment variables for the modbus path defined in /cvs/cds/caltech/target/c1psl2/npro_config.cmd from the local installation /opt/epics/ (which doesn't exist on the new server anymore) to the network location /cvs/cds/rtapps/epics-3.14.12.2_long/. This has been fixed and the slow diagnostic PSL channels are recording again. |
13761
|
Wed Apr 18 17:15:35 2018 |
rana | Configuration | Computers | NODUS: no xmgrace for dataviewer |
Turns out, there is no RPM for XmGrace on Scientific Linux 7. Since this is the graphic output of dataviewer, we can't use dataviewer through X windows until this gets fixed. CDS is looking into a xmGrace replacement, but it would be better if we can hijack a alt RH repo to steal a temporary xmgrace RPM. KT has been pinged. |
13897
|
Wed May 30 12:13:13 2018 |
rana | Update | Computers | NODUS: rsyncd + frames |
To get our rsync back to LDAS back up, I followed instructions from Dan Kozak:
- mounted /frames from fb1: I modified /etc/fstab
- modified /etc/rsyncd.conf to allow access from LDAS
- restarted rsync as daemon: 'sudo /usr/bin/rsync --daemon --config=/etc/rsyncd.conf'
Next need to figure out what the SL7 protocol is for running this as a daemon after boot - some kind of init.d thing probably |
13904
|
Thu May 31 17:47:12 2018 |
Koji | Update | Computers | megatron process cleaning up |
megatron had full of zombie medm processes due to some of the screenshot scripts.
I also found that apache2 is running on megatron without any configuration. I just disable it by
sudo update- rc.d apache2 disable
|
13906
|
Thu May 31 22:59:27 2018 |
Koji | Configuration | Computers | Shorewall on nodus |
[Jonathan Koji]
Shorewall (http://shorewall.net/), a tool to configure iptables, was installed on nodus.
The description about shorewall setting on nodus can be found here: https://wiki-40m.ligo.caltech.edu/NodusShorewallSetting
NDS (31200) on megatoron is not enabled outside of the firewall yet. |
14023
|
Tue Jun 26 22:06:33 2018 |
rana | Update | Computers | rossa: SL7.3 upgrade continues: DTT is back |
I used the following commands to get diaggui to run on rossa/SL7:
controls@rossa|lib64> ls -lrt libsasl*
-rwxr-xr-x. 1 root root 121296 Feb 16 2016 libsasl2.so.3.0.0
lrwxrwxrwx. 1 root root 17 Dec 18 2017 libsasl2.so -> libsasl2.so.3.0.0
lrwxrwxrwx. 1 root root 17 Dec 18 2017 libsasl2.so.3 -> libsasl2.so.3.0.0
controls@rossa|lib64> sudo ln -s libsasl2.so.3.0.0 libsasl2.so.2
controls@rossa|lib64> ls -lrt libsasl*
-rwxr-xr-x. 1 root root 121296 Feb 16 2016 libsasl2.so.3.0.0
lrwxrwxrwx. 1 root root 17 Dec 18 2017 libsasl2.so -> libsasl2.so.3.0.0
lrwxrwxrwx. 1 root root 17 Dec 18 2017 libsasl2.so.3 -> libsasl2.so.3.0.0
lrwxrwxrwx. 1 root root 17 Jun 26 22:02 libsasl2.so.2 -> libsasl2.so.3.0.0
Basically, I have set up a symbolic link to point sasl2.so.2 to sasl2.so.3.0.0. I've asked LLO again for some guidance on whether or not to find some backport in a non-standard SL7 repo. IF they reply, we may later replace this link with a regular file.
For the nonce, diaggui runs and is able to show us the spectra. We also got swept sine to work. But the FOTON launched from inside of AWGGUI doesn't inherit the sample frequency of the excitation channel so we can't filter noise injections from awggui yet. |
14025
|
Wed Jun 27 19:05:20 2018 |
rana | Update | Computers | rossa: SL7.3 upgrade continues: DTT is back |
UNELOGGED: someone has changed Pianosa from Ubuntu/Dumbian into SL7. Might be hackers.
Donatella is now the only Ubuntu machine in the control room. I propose we keep it this way for another month and then go fully SL7 if we find no bugs with Pianosa/Rossa. |
14026
|
Wed Jun 27 19:37:16 2018 |
Koji | Configuration | Computers | New NAT router installed |
[Larry, Koji]
We replaced the NAT router between martian and the campus net. We have the administrative web page available for the NAT router, but it is accessible from inside (=martian) as expected.
We changed the IP address registration of nodus for the internet so that the packets to nodus is directed to the NAT router. Then the NAT router forwards the packets to actual nodus only for the allowed ports. Because of this change of the IP we had a few confusions. First of all, martian net, which relies on chiara for DNS resolution. The 40m wifi router seemed to have internal DNS cache and required to reboot to make the IP change effective.
The WAN side cable of nodus was removed.
We needed to run "sudo rndc flush" to force chiara's bind9 to refresh the cache. We also needed to restart httpd ("sudo systemctl restart httpd") on nodus to make the port 8081 work properly.
So far, ssh (22), web services (30889), and elog (8081, 8080) were tested. We also need to test megatron NDS port forwarding and rsync for nodus, too.
Finally I turned off the firewall rules of shorewall on nodus as it is no longer necessary.
More details are found on the wiki page. https://wiki-40m.ligo.caltech.edu/FirewallSetting |
Attachment 1: P_20180627_193357.jpg
|
|
14104
|
Wed Jul 25 22:46:15 2018 |
gautam | Configuration | Computers | NDS access from outside |
After this work, I've been having some trouble getting data with Python NDS. Eventually, I figured out that the nds connection request has to be pointed at '131.215.115.200' (the address of the NAT router which faces the outside world), port 31200 (it used to work with 'nds40.ligo.caltech.edu' or '131.215.115.189'). So the following snippet in python allows a connection to be opened. Offline access of frame data via NDS2 now seems possible.
import nds2
conn = nds2.connection('131.215.115.200',31200)
Quote: |
So far, ssh (22), web services (30889), and elog (8081, 8080) were tested. We also need to test megatron NDS port forwarding and rsync for nodus, too.Finally I turned off the firewall rules of shorewall on nodus as it is no longer necessary.
|
|
14121
|
Wed Aug 1 16:23:48 2018 |
Koji | Summary | Computers | Transition of the main NFS disk on chiara |
[Gautam Koji]
Taking the opportunity to shutdown c1ioo for adding a DAC card, we shutdown chiara and worked on moving of the main disk to the bigger home.
We shutdown most of the martian machines including the control machines, megatron, optimus, and nodus.
- Before shutting down chiara, we ran rsync to make the 4TB disk (used to be teh backup) and /cvs/cds synced.
sudo rsync -a --progress /home/cds/ /media/40mBackup
- Modified /etc/fstab
proc /proc proc nodev,noexec,nosuid 0 0
# / was on /dev/sda1 during installation
UUID=972db769-4020-4b74-b943-9b868c26043a / ext4 errors=remount-ro 0 1
# swap was on /dev/sda5 during installation
UUID=a3f5d977-72d7-47c9-a059-38633d16413e none swap sw 0 0
UUID="90a5c98a-22fb-4685-9c17-77ed07a5e000" /media/40mBackup ext4 defaults,relatime,commit=60 0 0
#fb:/frames /frames nfs ro,bg
UUID=92dc7073-bf4d-4c58-8052-63129ff5755b /home/cds ext4 defaults,relatime,commit=60 0 0
- Shutdown chiara. Put the 4TB disk in the chassis. We also installed a new disk (but later it turned out that it only has 2TB...)
- Restart the mahcine. This already made the 4TB disk mounted as /cvs/cds .
- Restart bind9 with DHCP for the diskless clients (cf. https://wiki-40m.ligo.caltech.edu/CDS/How_to_join_martian)
sudo service bind9 restart
sudo service isc-dhcp-server restart
- Looks like /etc/resolv.conf is automatically overwritten by a tool or something everytime we restart the machine!? I still don't know how to avoid this. (cf. https://www.ctrl.blog/entry/resolvconf-tutorial). But at least for today we manually wrote /etc/resolv.conf
controls@chiara|backup> cat /etc/resolv.conf
# Dynamic resolv.conf(5) file for glibc resolver(3) generated by resolvconf (8)
# DO NOT EDIT THIS FILE BY HAND -- YOUR CHANGES WILL BE OVERWRITTEN
nameserver 192.168.113.104
nameserver 131.215.125.1
nameserver 8.8.8.8
search martian
|
14122
|
Wed Aug 1 19:41:15 2018 |
gautam | Summary | Computers | RTCDS recovery, c1ioo changes |
[Gautam Koji]
After this work, we recovered the nominal RTCDS state. The main points were:
- We needed to restart the bind9 service on chiara such that the FEs knew their IP addresses upon reboot and hence, could get their root filesystems over NFS.
- We recovered suspension local damping, IMC locking and POX/POY locking with nominal arm transmission.
Some stuff that is not working as usual:
- The EX QPD is reporting strange transmission values - even with the PRM completely misaligned, it reports transmission of ~30. But we were able to lock the Xarm with the Thorlabs PD and revover transmission of ~1.15.
- The X arm green does not stay locked to the cavity - the alignment looks fine, and the green flashes are strong, but the lock does not hold. This shouldn't be directly connected to anything we did today since the Green PDH servo is entirely analog.
I made a model change in c1x03 (the IOP model on c1ioo) to add a DAC part. The model compiled, installed and started correctly, and looking at dmesg on c1ioo, it recognises the DAC card as what it is. Next step is to use a core on c1ioo for a c1omc model, and actually try driving some signals.
Note that the only change made to the c1ioo expansion chassis was that a DAC card was installed into the PCIe bus. The adaptor card which allows interfacing the DAC card to an AI board was already in the expansion chassis, presumably from whenever the DAC was removed from this machine.
*I think I forgot to restart optimus after this work...
|
Attachment 1: CDS_overview.png
|
|
14123
|
Wed Aug 1 20:44:57 2018 |
gautam | Summary | Computers | c1omc model (re?)created |
The main motivation behind adding a DAC card in c1ioo was to setup an RTCDS model for the OMC. Attachment #1 shows the new look CDS overview screen. Here is what I did.
Mostly, I followed instructions from when I setup the model for the EX green PZTs.
Simulink model:
The model is just a toy for now (CDS parameters, ADC block and 2 CDS filter modules). I leave it to Aaron to actually populate it, check functionality etc. The path to the model is /opt/rtcds/caltech/c1/userapps/release/isc/c1/models/c1omc.mdl. I am listing the parameters set on the CDS_PARAMETERS block:
- host = c1ioo
- site = c1
- rate = 16k
- dcuid = 27 (which I chose after making sure that this dcuid was not used on this list which I also updated by adding c1omc and moving c1imc to "old")
- specific_cpu = 6 (again chosen after checking the available CPUs in the above list and confirming using the cset utility).
- adc_Slave = 1
- shmem_daq = 1
- no_rfm_dma = 1
- biquad = 1
Building and installing model:
Once the model was installed, I logged into c1ioo, and built and installed the models using the usual rtcds make and rtcds install instructions. Before starting the model, I edited /diskless/root.jessie/etc/rtsystab to allow c1omc to be run on c1ioo. Using sudo cset set, I verified that CPU #6 is no longer listed (if I understand correctly, the RTCDS system takes over the core).
MEDM:
To reflect all this on the MEDM CDS OVERVIEW screen, I just edited the screen.
- Moved the orange explanation of bits over to the c1iscey panel to make space in the c1ioo panel.
- Edited the macros to reflect the c1omc parameters.
DAQD:
Finally, I followed the instructions here to get the channels into frames and make all the indicators green. Went into fb and restarted the daqd processes. All looks good . I'm going to leave the model running overnight to investigate stability. I forgot to svn commit the model tonight, will do it tomorrow.
The testing plan (at least initially) is to install the AA and AI boards from the OMC rack in 1X1/1X2. Then we will have short SCSI cables running from the ADC/DAC to these. The actual HV driving stages will remain in the OMC rack (NE corner of AS table).
@Steve, can we get 10 Male-Female D9 cables so that we can run them from 1X1/1X2 to the OMC rack?
Unrelated to this work: There were 2 crashes of the models on c1lsc, one ~6pm and one right now ~1030pm. The restart script brought everything back gracefully ... |
Attachment 1: CDS_OVERVIEW_withOMC.png
|
|
14126
|
Thu Aug 2 20:54:18 2018 |
gautam | Summary | Computers | c1omc model looks stable |
Actually, c1lsc had crashed again sometime last night so I had to reboot everything this morning. I used the reboot script again, but I increased the sleep time between trying to start up the models again so that I could walk into the VEA and power cycle the c1lsc expansion chassis, as this kind of frequent model crash has been fixed by doing so in the past. Sure enough, there have been no issues since I rebooted everything at ~1030 in the morning.
The c1omc model itself has been stable as well, though of course, there is nothing in there at the moment. I may do a check of the newly installed DAC tomorrow just to see that we can put out a sine wave.
Steve has ordered the D-sub cabling that will allow us to route signals between AA/AI boards in 1X1/1X2 to the HV PZT electronics in the OMC rack. Things look setup for a measurement next week. Aaron will post a block diagram + photoz of what box goes where in the electronics racks. |
14127
|
Thu Aug 2 23:09:25 2018 |
rana | Summary | Computers | X Green "Mystery" solved |
I'm going to guess that this was me: I was disconnecting some octopus power strip nonsense down there (in particular illuminators and cameras), so I might have turned off the AUX rack by mistake.
Quote: |
I walked down to the X end and found that the entire AUX laser electronics rack isn't getting any power. There was no elog about this.
I couldn't find any free points in the power strip where I think all this stuff was plugged in so I'm going to hold off on resurrecting this until tomorrow when I'll work with Steve.
Quote: |
The X arm green does not stay locked to the cavity - the alignment looks fine, and the green flashes are strong, but the lock does not hold. This shouldn't be directly connected to anything we did today since the Green PDH servo is entirely analog.
|
|
|
14138
|
Mon Aug 6 09:42:10 2018 |
Koji | Summary | Computers | Transition of the main NFS disk on chiara |
Follow up:
- At least it was confirmed that the local backup (4TB->2TB) is regularly running every morning.
- The 2TB disk was used up to 95%. To ease the size of the remaining space, I have further compressed the burt snapshot folders. (~2016). This released another 150GB. The 2TB is currently used up to 87%.
Prev
Filesystem 1K-blocks Used Available Use% Mounted on
/dev/sdc1 3845709644 1731391748 1918967020 48% /home/cds
/dev/sdd1 2113786796 1886162780 120249888 95% /media/40mBackup
Now
Filesystem 1K-blocks Used Available Use% Mounted on
/dev/sdc1 3845709644 1731706744 1918652024 48% /home/cds
/dev/sdd1 2113786796 1728124828 278287840 87% /media/40mBackup
|
14197
|
Wed Sep 12 22:22:30 2018 |
Koji | Update | Computers | SSL2.0, SSL3.0 disabled |
LIGO GC notified us that nodus had SSL2.0 and SSL3.0 enabled. This has been disabled now.
The details are described on 40m wiki. |
14283
|
Wed Nov 7 19:20:53 2018 |
gautam | Update | Computers | Paola Battery Error |
The VEA vertex laptop, paola, has a flashing orange indicator which I take to mean some kind of battery issue. When the laptop is disconnected from its AC power adaptor, it immediately shuts down. So this machine is kind of useless for its intended purpose of being a portable computer we can work at optical tables with . The actual battery diagnostics (using upower) don't report any errors. |
14382
|
Thu Jan 3 21:17:49 2019 |
rana | Configuration | Computers | Workstation Upgrade: Donatella -> Scientific Linux 7.2 |
donatella was one of our last workstations running ubuntu12. we installed SL7 on there today
- had to use a DVD; wouldn't boot from USB stick
- made sure to use userID=1001 and groupID=1001 at the initial install part
- went to the Keith Thorne LLO wiki on SL7
- The 'yum update' command failed due to a gstreamer conflict. I did "yum remove gstreamer1-plugins-ugly-free-1.10.4-3.el7.x86_64" and then it continued a bit more.
-
Then there are ~20 errors related to gds-crtools that look like this:Error: Package: gds-crtools-2.18.12-1.el7.x86_64 (lscsoft-production) Requires: libMatrix.so.6.14()(64bit)
- I re-ran the yum install .... command using the --skip-broken command and that seemed to complete, although I guess the GDS stuff will not work.
- Installed: terminator, inconsolata-fonts,
- Installed XFCE desktop as per K Thorne: yum groupinstall "Xfce" -y
-
|
Attachment 1: IMG_20190103_205158.jpg
|
|
14464
|
Mon Feb 18 19:16:55 2019 |
rana | Summary | Computers | new laptop setup: ASIA |
The old IBM laptop (Asia) has died from a fan error after 7 years. WE have a new Lenovo 330 IdeaPad to replace it:
- to enter bios, the usual FN keys don't work. Power off laptop. Insert paperclip into small hole on laptop side with upside-down U symbol. Laptop powers up into BIOS setup.
- Insert SL 7.6 DVD into drive
- Change all settings from modern UEFI into Legacy support. Change Boot order to put CDROM first.
- Boot.
- Touchpad is not detected. Hookup mouse for setup.
- Delete windows partition.
- Setup wireless network according to (https://wiki-40m.ligo.caltech.edu/Network). Computer name = asia.martian.
- Set root password. Do not create user (we want to make the controls acct later using the command line so that we can set userID and groupID both to 1001).
- Begin install...lots of disk access noises for awhile...
Install done. Touchpad not recognized by linux - lots of forum posts about kernel patching...Arrgh! |
14465
|
Tue Feb 19 19:03:18 2019 |
rana | Update | Computers | Martian router -> WPA2 |
I have swapped our martian router's WiFi security over to WPA2 (AES) from the previous, less-secure, system. Creds are in the secrets-40-red. |
14543
|
Mon Apr 15 18:29:07 2019 |
rana | Summary | Computers | new laptop setup: ASIA - yum issues |
had trouble using YUM to update. This turned out to be a config problem with our Martian router, not the new laptop. Since I've changed the WiFi pwd awhile ago for the martian access for the CDS laptops, you'll have to enter that in order to use the laptops.
turned out to be some Access Control nonsense inside of the router. Even loggin in as admin with a cable gave some of the fields the greyed out color (had to hover over the link and then type the URL directly in the browser window). ASIA is now able to connect and use YUM + usual connections. Gautam and I have also moved the router a little to get easier view of its LED lights and not blockk its WiFi signal with the cable tray. We'll get a little shelf so that we can mount it ~1 foot off of the wall.
still, this seems like a bad laptop choice: the Lenovo Ideapad 330 will not have its touchpad supported by SL7 without compiling a new version of the kernel  |
14589
|
Thu May 2 15:15:15 2019 |
Jon | Omnistructure | Computers | susaux machine renamed |
Now that the replacement susaux machine is installed and fully tested, I renamed it from c1susaux2 to c1susaux and updated the DNS lookup tables on chiara accordingly. |
14598
|
Wed May 8 22:11:46 2019 |
rana | Summary | Computers | new laptop setup: ASIA - yum issues |
- setup controls user using K Thorne LLO CDS offsite workstation instructions
- modified /etc/fstab ala pianosa to NFS mount disks
- set up symlinks as other workstations
- troubles with libsasl2 and libmetaio libraries as usual for SL7 - doing symlink tricks
- setup shared .bashrc
- now running 'yum install gds-all' to see if we need more local libraries to run GDS from the shared disks...
|
14624
|
Mon May 20 13:16:57 2019 |
gautam | Summary | Computers | new laptop setup: ASIA - ndscope and diaggui |
Following instructions here, I installed ndscope on this machine. DTT still could not be be run from this machine, and I want to use this today - so I ran the following commands from the K. Thorne setup instructions.
yum clean metadata
yum update
yum install cds-workstation pcaspy subversion redhat-lsb gnuradio google-chrome-stable xorg-x11-drv-nvidia epel-release redhat-lsb
Now diaggui can be opened, and spectra can be made. I'm moving this laptop to its new home at EY.
Quote: |
- now running 'yum install gds-all' to see if we need more local libraries to run GDS from the shared disks...
|
|
14679
|
Mon Jun 17 16:02:17 2019 |
aaron | Update | Computers | keyed PSL crate |
Milind pointed out that all boxes on the medm screens were white. I didn't have diagnostics from the medm screens, so I started following the troubleshooting steps on the restart procedures page.
It seemed like maybe a frontend problem. I tried telnet-ing into several of the fe, and wasn't able to access c1psl. The section on c1psl mentions that if this machine crashes, the screens will go white and the crate needs to be turned off and on. Millind did this.
Now, most of the status lights are restored (screenshot).
Milind: I did a burtrestore following this and locked the PMC following the steps described in this elog. |
Attachment 1: after_keying_crate.png
|
|
14767
|
Wed Jul 17 17:56:18 2019 |
Koji | Configuration | Computers | Gave resolv.conf to giada |
Kruthi noticed that she could not login to rossa from giada.
I checked /etc/resolv.conf and it was
nameserver 127.0.0.1
so obviously it is useless to refer localhost (i.e. giada) as a nameserver.
I copied our usual resolv.conf to giada as following:
nameserver 192.168.113.104
nameserver 131.215.125.1
nameserver 8.8.8.8
search martian
Giada's ssh known_host had unupdated entry for rossa, so I had to clean it up, but after that we can connect to rossa from giada just by "ssh rossa".
Case closed. |
14799
|
Mon Jul 22 21:04:40 2019 |
rana | Update | Computers | making rossa great again |
- copied over /etc/fstab lines from pianosa sothat the NFS mounts work correctly
- added symlinks so that the NFS dirs mount in the right dirs
- installed Opera browser
- symlink libsasl2.so.3 -> libsasl2.so.2 and now DTT runs and can get data now and in the past
- DTT can natively produce PDF so you don't have to take screen caps of your camera phone and make a chalk drawing of that anymore
- sitemap/MEDM is working
- after editing fonts.alias as detailed in Thorne wiki, I ran 'sudo xset fp rehash' to get MEDM to notice new fonts. MEDM Scalable fonts are back!!
- installed Grace and now dataviewer works
- ndscope not running: yum install ndscope breaks because it can't find a couple of python34 packages

- tested that AWGGUI also runs and puts in real sine waves
|
Attachment 1: seis.pdf
|
|
14812
|
Thu Jul 25 14:28:03 2019 |
gautam | Configuration | Computers | firewalld disabled for EPICS CA |
I think rana did some more changes to this workstation to make it useful for commissioning activities - but the MEDM screens were still white blanks. The problem was that the firewalld wasn't disabled (last two steps of the KThorne setup wiki). I disabled it. Now donatella can run MEDM, ndscope and StripTool. DTT doesn't work to get online data because of a "Synchronization Error", I'm not bothering with this for now. I think Kruthi successfully demonstrated the fetching of offline data with DTT. |
Attachment 1: donatellaCommissioning.png
|
|
14813
|
Thu Jul 25 20:08:36 2019 |
gautam | Update | Computers | Solidworks machine |
I brought one CPU (Dell T3500) and one 28" monitor from Mike Pedraza's office in Downs to the 40m. It is on Steve's desk right now, pending setup. The machine already has Solidworks and Altium installed on it, so we can set it up at our leisure. The login credentials are pasted on the CPU with a post-it should anyone wish to set it up. |
14820
|
Wed Jul 31 14:44:11 2019 |
gautam | Update | Computers | Supermicro inventory |
Chub brought the replacement Supermicro we ordered to the 40m today. I stored it at the SW entrance to the VEA, along with the other Supermicro. At the time of writing, we have, in hand, two (unused) Supermicro machines. One is meant for EY and the other is meant for c1psl/c1iool0. DDR3 RAM and 120 GB SSD drives have also been ordered, but have not yet arrived (I think, Chub, please correct me if I'm wrong).
Update 20190802: The DDR3 RAM and 120 GB SSD drives arrived, and are stored in the FE hardware cabinet along the east arm. So at the time of writing, we have 2 sets of (Supermicro + 120GB HD + 4GB RAM).
Quote: |
We should ask Chub to reorder several more SuperMicro rackmount machines, SSD drives, and DRAM cards. Gautam has the list of parts from Johannes' last order.
|
|
14829
|
Mon Aug 5 17:23:26 2019 |
gautam | Summary | Computers | WiFi Settings on asia |
The VEA laptop asia was configured to be able to connect to too many WiFi networks - it was getting conflicted in its default position at the vertex and trying to hop between networks, for some reason trying to connect to networks that had poor signal strength. I deleted all options from the known networks except 40MARS. Now the network connection seems much more stable and reliable. |
14831
|
Tue Aug 6 14:12:02 2019 |
yehonathan | Update | Computers | making rossa great again |
cdsutils is not working on rossa.
Import cdsutils produces this error:
In [2]: import cdsutils
---------------------------------------------------------------------------
OSError Traceback (most recent call last)
<ipython-input-2-949babce8459> in <module>()
----> 1 import cdsutils
/ligo/apps/linux-x86_64/cdsutils-480/lib/python2.7/site-packages/cdsutils/__init__.py in <module>()
53
54 try:
---> 55 import awg
56 except ImportError:
57 pass
/ligo/apps/linux-x86_64/cdsutils-480/lib/python2.7/site-packages/cdsutils/awg.py in <module>()
30 """
31
---> 32 import sys, numpy, awgbase
33 from time import sleep
34 from threading import Thread, Event, Lock
/ligo/apps/linux-x86_64/cdsutils-480/lib/python2.7/site-packages/cdsutils/awgbase.py in <module>()
17 libawg = CDLL('libawg.so')
18 libtestpoint = CDLL('libtestpoint.so')
---> 19 libSIStr = CDLL('libSIStr.so')
20
21 ####
/ligo/apps/anaconda/lib/python2.7/ctypes/__init__.pyc in __init__(self, name, mode, handle, use_errno, use_last_error)
364
365 if handle is None:
--> 366 self._handle = _dlopen(self._name, mode)
367 else:
368 self._handle = handle
OSError: libSIStr.so: cannot open shared object file: No such file or directory |
14864
|
Fri Sep 6 18:08:29 2019 |
rana | Update | Computers | Alarm noise from smart-ups machine under workstation? |
please no one touch the UPS: last time it destroyed ROSSA. Please ask Chub to order the replacement batteries so we can do this in a controlled way (fully shutting down ALL workstations first). Last time we wasted 8 hours on ROSSA rebuilding.
Quote: |
There was an alarm sound from the Smart-UPS 2200 sitting under the workstation. I see that the 'replace battery' light is red, and this elog tells me that these batteries are replaced every ~1-4 years; the last replacement was march 2016. Holding down the 'test' button for 2-3 seconds results in the alarm sound and does not clear the replace battery indicator.
|
|
14873
|
Thu Sep 12 09:49:07 2019 |
gautam | Update | Computers | control rm wkstns shutdown |
Chub wanted to get the correct part number for the replacement UPS batteries which necessitated opening up the UPS. To be cautious, all the workstations were shutdown at ~9:30am while the unit is pulled out and inspected. While looking at the UPS, we found that the insulation on the main power cord is damaged at both ends. Chub will post photos.
However, despite these precautions, rossa reports some error on boot up (not the same xdisp junk that happened before). pianosa and donatella came back up just fine. It is remotely accessible (ssh-able) though so maybe we can recover it...
Quote: |
please no one touch the UPS: last time it destroyed ROSSA. Please ask Chub to order the replacement batteries so we can do this in a controlled way (fully shutting down ALL workstations first). Last time we wasted 8 hours on ROSSA rebuilding
|
|
Attachment 1: IMG_7943.JPG
|
|
14913
|
Mon Sep 30 11:42:36 2019 |
aaron | Update | Computers | control rm wkstns shutdown |
I booted Rossa in rescue mode; though I see no errors on bootup, I still see the same error ("a problem has occurred") after boot, and a prompt to logout. I powered rossa off/on (single short press of power button), no change.
Booting in debug mode, I see that the error occurs when mounting /cvs/cds, with the error
[FAILED] Failed to mount /cvs/cds.
See `systemctl status cvs-cds.mount` for details.
[DEPEND] Dependency failed for Remote File System
Which is odd, because when I boot in recovery mode, is mounts /cvs/cds successfully.
I booted in emergency mode by adding to the boot command
systemd.unit=emergency.target
but didn't have the appropriate root password to troubleshoot further (the usual two didn't work). |
14925
|
Wed Oct 2 20:45:18 2019 |
rana | Update | Computers | rossa revival |
Formatted and re-installing OS on rossa for the 3rd or 4th time this year. I suggest that whoever is installing software and adjusting video settings please stop.
If you feel you need to tinker deeply, use ottavia or zita and then be prepared to show up and fix it.
While I was moving the UPS around, the network lights went out for Rossa, so I may have damaged the network interface or cable. Debugging continues. |
14935
|
Thu Oct 3 21:50:22 2019 |
rana | Update | Computers | rossa revival |
Got the network to work again just by unplugging the power cord and letting it sit for awhile. But corrupted OS by trying to install Nvidia drivers.
https://www.advancedclustering.com/act_kb/installing-nvidia-drivers-rhel-centos-7/ |
14994
|
Mon Oct 28 18:55:06 2019 |
rana | Update | Computers | rossa revival |
back on new Rossa from Xi computing
- switched to using Display Port for video; this works. The DVi, HDMI, VGA ports are connected to the motherboard rather than the video card, so they are not active.
- runs super slow w/ SL 7.6; maybe some service is running after startup?
- install repos and update according to LLO CDS wiki
- add controls user and group according to LLO wiki
- remove gstreamer ugly because it breaks yum update
- run 'yum update --skip-broken' because GDS doesn't work
- turn off old selinux stuff
- modify fstab to get NFS
Next:
- finish mounting
- xfce
- figure out why the LLO install instructions can't install any CDS software (e.g. root, DTT, etc)
Update: Sun Nov 3 18:08:48 2019
- moved the SL7 fresh install repos back into etc/yum.repos.d/. The LLO instructions has me remove them, but the LLO supplied repos are no good for standard apps. After putting these back was able to install standard apps (terminator, root, diaggui)
- copied over /etc/fstab lines from pianosa sothat the NFS mounts work correctly
- added symlinks so that the NFS dirs mount in the right dirs
- symlink libsasl2.so.3 -> libsasl2.so.2 and now DTT runs and can get data now and in the past
- install XFCE
- sitemap / MEDM works
- Did "sudo ln -s /usr/lib64/libXm.so.4 /usr/lib64/libXm.so.3" to enable StripTool.
Update: Fri Nov 15 00:00:26 2019:
- random hanging of machine while doing various window moving or workspace switching
- turned off power management in XFCE
- turned off power management on monitor
- disabled SELINUX
- firewalld was already off
- installed most, pdftk, htop, glances, qtgrace, lesstif
- dataviewer now works and QTgrace is much nicer than XMGrace
|
15031
|
Fri Nov 15 18:59:08 2019 |
rana | Update | Computers | ZITA: started upgrade from Ubuntu 14 LTS to 18 LTS |
and so it begins...until this is finished I have turned off the projector and moved the striptools to the big TV (time to look for Black Friday deals to replace the projector with a 120 inch LED TV) |
15033
|
Mon Nov 18 16:32:15 2019 |
gautam | Update | Computers | ZITA: started upgrade from Ubuntu 14 LTS to 18 LTS |
the upgrade seems to have been successfully executed - the machine was restarted at ~430pm local time. Projector remains off and diagnostic striptools are on the samsung.
Quote: |
and so it begins...until this is finished I have turned off the projector and moved the striptools to the big TV (time to look for Black Friday deals to replace the projector with a 120 inch LED TV)
|
|
15084
|
Sun Dec 8 20:27:11 2019 |
rana | Update | Computers | Viviana upgrade to Ubuntu 16 |
The IBM laptop at EX was running Ubuntu 14, so I allowed it to start upgrading itself to Ubuntu16 as it desired. After it is done, I will upgrade it to 18.04 LTS. We should have them all run LTS. |