Mon Jul 22 23:53:16 2019 |
gautam | Update | ALS | IR ALS locking attempt |
Summary:
My goal tonight was to lock the PSL frequency to be resonant in the XARM cavity, using the PSL+EX beat as the error signal. I was not successful - mainly, I was plagued by huge BR mode coupling in the error signal, and I could not enable the BR notch filter in the control loop without breaking the lock. Need to think about next steps.
Details:
- POX and POY locking was easily restored.
- EX green alignment was tweaked at the end-table. A large YAW correction was required, which I opted to apply on the mechanical mirror mounts rather than the PZTs. GTRX ~0.4 was recovered.
- The arm cavity length was first locked using POX as an error signal
- Then I looked at the out-of-loop ALS noise, trusting the DFD's V/Hz calibration (red-trace in Attachment #1).
- I judged it to be close enough to the benchmark reference (green-trace in Attachment #1), and so decided that I could go ahead and try locking.
- A modified version of the script /opt/rtcds/caltech/c1/scripts/XARM/Lock_ALS_XARM.py was used to transition control from POX to the ALS error signal
- I found that I had to change the sign of the CARM loop gain for the servo to remain stable (in this config, CARM-->MC2 length, thereby modifying the IMC frequency to keep the PSL resonant in the XARM cavity).
- I don't know why this sign change was required - we are still sticking to the same convention that the beat frequency increases when the temperature slider for the EX laser is incremented in counts.
- The script failed multiple times at the BOOST/BR notch filter enabling step.
- Doing these steps manually, I found that turning the BR notch, FM6, ON destroyed the lock immediately.
- Motivated by this observation, I looked at the in-loop error signal spectrum, see Attachment #2. Here, the PSL frequency is servoed by the ALS error signal, but the BR notch filter isn't enabled.
- The Bounce-mode peak is huge - where is this coming from? It is absent in the ALS spectrum when the XARM is locked with POX. So it is somehow connected with actuating on the MC2 suspension? Or is it that the FM6=BounceRoll filter of the XARM loop is squishing the noise when looking at the ALS spectrum in POX lock, i.e. Attachment #1? In which case, why can't I engage FM6 for the CARM loop???
Anyway, now that I have a workable set of settings that gets me close to the ALS lock of the XARM, I expect debugging to proceed faster.
Update 2019 July 23: I looked at the control loop shape today, see Attachment #3. I'm not sure I understand why the "BounceRoll" filter in this filter bank looks like a resonant gain rather than a notch, as it does for the Oplev or SUSPOS loops for example - don't we want to not actuate at these frequencies because the reason the signal exists is because of the imperfect OSEM/magnet positioning? This does not explain the spectrum shown in Attachment #2 however, as that filter was disabled. |
Attachment 1: ALS_X_outOfLoopnoise.pdf
|
|
Attachment 2: ALS_X_inLoopnoise.pdf
|
|
Attachment 3: CARM_loopShape.pdf
|
|
14799
|
Mon Jul 22 21:04:40 2019 |
rana | Update | Computers | making rossa great again |
- copied over /etc/fstab lines from pianosa sothat the NFS mounts work correctly
- added symlinks so that the NFS dirs mount in the right dirs
- installed Opera browser
- symlink libsasl2.so.3 -> libsasl2.so.2 and now DTT runs and can get data now and in the past
- DTT can natively produce PDF so you don't have to take screen caps of your camera phone and make a chalk drawing of that anymore
- sitemap/MEDM is working
- after editing fonts.alias as detailed in Thorne wiki, I ran 'sudo xset fp rehash' to get MEDM to notice new fonts. MEDM Scalable fonts are back!!
- installed Grace and now dataviewer works
- ndscope not running: yum install ndscope breaks because it can't find a couple of python34 packages

- tested that AWGGUI also runs and puts in real sine waves
|
Attachment 1: seis.pdf
|
|
14798
|
Mon Jul 22 13:32:55 2019 |
Kruthi | Update | SUS | Test mass pitch adjustment test |
[Kruthi, Milind]
On Friday, Milind and I performed the pitch adjustment test Rana had asked us to do. Only 1 blue beam in case of ITMX and two in case of ETMY, ETMX and ITMY were accessible. Milind (of mass 72 kg as of 10 May 2019) stood on each of the accessible blue beams of the test mass chambers for one minute and I recorded the corresponding gps time. Before moving to the next beam, we spared more than a minute for relaxation after the standing end time. Following are the recorded gps times.
|
ETMX
|
ITMX
|
ETMY
|
ITMY
|
|
Beam 1
|
Beam 2
|
Beam 1
|
Beam 1
|
Beam 2
|
Beam 1
|
Beam 2
|
Standing start time (gps)
|
1247620911
|
1247621055
|
1247621984
|
1247622394
|
1247622585
|
1247622180
|
1247622814
|
Standing end time (gps)
|
1247620974
|
1247621118
|
1247622058
|
1247622459
|
1247622647
|
1247622250
|
1247622880
|
PS: For each blue beam relaxation time ~ 1 min after the standing end time |
Attachment 1: ETMX.pdf
|
|
Attachment 2: itmx.pdf
|
|
Attachment 3: ETMY.pdf
|
|
Attachment 4: ITMY.pdf
|
|
Attachment 5: 3f1a82f2-b86a-469e-8914-9278a216c5f9.jpg
|
|
Attachment 6: 1d174307-d940-42e6-812b-83417d0f5f6a.jpg
|
|
14797
|
Mon Jul 22 13:26:41 2019 |
Kruthi | Update | IOO | MC locked |
The MC2 has 2 GigE cameras right now. I'll put back the analog asap.
Quote: |
I found the MC2 face camera disabled(?) and the MC servo board input turned off. I turned the MC locking back on but I don't see any camera image yet.
|
|
14796
|
Mon Jul 22 12:57:35 2019 |
Kruthi | Update | Loss Measurement | MC2 loss map |
In my script I have used "CAM-ETMX_SNAP" only; while entering it in the elog I made a mistake, my bad!
Quote: |
I think ezca.Ezca().write() takes the string "CAM-ETMX_SNAP" as an argument and not C1:CAM-ETMX_SNAP. See this, line 47. Are you sure this is not the problem?
Quote: |
The camera server keeps throwing the error: failed to grab frames. Milind suggested that it might a problem with the ethernet cable, so I even unplugged it and connected it again; it still had the same issue. One more thing I noticed was, it does take snapshots sometimes with the terminal command caput C1:CAM-ETMX_SNAP 1, but produces a segmentation fault when ezca.Ezca().write(C1:CAM-ETMX_SNAP, 1) is used via ipython. When the terminal command also fails to take snapshots, I noticed that the SNAP button on the GigE medm screen remains on and doesn't switch back to OFF like it is supposed to.
|
|
|
14795
|
Mon Jul 22 07:21:13 2019 |
gautam | Update | CDS | painosa messed with |
Somebody changed the settings on painosa without elogging anything about it. Why does this keep happening? I thought the point of the elog was to communicate. I think there are sufficient number of problems in the lab without me having to manually reset the control room workstation settings every week. Please make an elog if you change something. |
14794
|
Sun Jul 21 22:16:34 2019 |
rana | Update | General | rossa Xdisp bricked |
"bricked" is to mean that it has the functionality of a brick and can be tossed. But rossa seems to have just gotten some software config corruption. I spent a couple hours reinstalling SL7 today as per my previous elog notes and the X display seems to work as before.
i.e. it was fine with the default setup, except for the ole "X chrashes if the mouse goes to left side of screen". As before, I
- blacklisted the nouvaeu driver (which is used by default)
- download the NVIDIA driver as per the link
- run its installation from the no-X terminal
left side of screen is safe again
This time I installed SL7.6 and followed the K Thorne wiki. But its having trouble installing cds-root because it can't find root.
|
14793
|
Sun Jul 21 20:23:35 2019 |
rana | Update | IOO | MC locked |
I found the MC2 face camera disabled(?) and the MC servo board input turned off. I turned the MC locking back on but I don't see any camera image yet. |
14792
|
Sun Jul 21 19:27:25 2019 |
Milind | Update | Loss Measurement | MC2 loss map |
I think ezca.Ezca().write() takes the string "CAM-ETMX_SNAP" as an argument and not C1:CAM-ETMX_SNAP. See this, line 47. Are you sure this is not the problem?
Quote: |
The camera server keeps throwing the error: failed to grab frames. Milind suggested that it might a problem with the ethernet cable, so I even unplugged it and connected it again; it still had the same issue. One more thing I noticed was, it does take snapshots sometimes with the terminal command caput C1:CAM-ETMX_SNAP 1, but produces a segmentation fault when ezca.Ezca().write(C1:CAM-ETMX_SNAP, 1) is used via ipython. When the terminal command also fails to take snapshots, I noticed that the SNAP button on the GigE medm screen remains on and doesn't switch back to OFF like it is supposed to.
|
|
14791
|
Sun Jul 21 17:17:03 2019 |
Kruthi | Update | Loss Measurement | MC2 loss map |
The camera server keeps throwing the error: failed to grab frames. Milind suggested that it might a problem with the ethernet cable, so I even unplugged it and connected it again; it still had the same issue. One more thing I noticed was, it does take snapshots sometimes with the terminal command caput C1:CAM-ETMX_SNAP 1, but produces a segmentation fault when ezca.Ezca().write(C1:CAM-ETMX_SNAP, 1) ezca.Ezca().write(CAM-ETMX_SNAP, 1) is used via ipython. When the terminal command also fails to take snapshots, I noticed that the SNAP button on the GigE medm screen remains on and doesn't switch back to OFF like it is supposed to.
Quote: |
Can you please be more specific about what the error is? Is this the usual instability with the camera server code? Or was it something new?
Quote: |
The camera server is throwing an error and is not grabbing snapshots :(
|
|
|
14790
|
Sun Jul 21 12:55:38 2019 |
gautam | Update | CDS | CM board Latch Enable test script |
DATED, SEE ELOG14941 for the most up-to-date info on latch.py.
I wrote (/cvs/cds/caltech/target/c1iscaux3/latch.py) and tested the logic illustrated in Attachment #1. Results of a test are shown in Attachment #2, the various channels change as expected. Note that for negative values of the gain channel, the corresponding "BITS" channel will take on values like 65536 - this is because the mbboDirect data type is a 16 bit data type, and presumably the MSB is the sign bit. A bit mask is applied to this channel before the actual BIO unit bits are set - we should verify that the correct behavior happens, but I don't immediately see any problems.
To me, this is a robust logic, but it will benefit from more sets of eyes giving it a look over. The idea is to run this continuously on the Supermicro machine.
Apart from this, I also fixed some errors in the mbboDirect record syntax - so now I am able to start up the EPICS server without it throwing any error messages. It remains to verify that changing an EPICS gain slider results in the appropriate gain bits being flipped in the correct way (on the hardware side, I think the correct behavior is happening on the software end). For this testing, I turned off the old c1iscaux crate at ~10am, and started up the server on c1iscaux3. I am reverting to the nominal config now (~1pm).
Further testing will require the wiring inside the Acromag chassis to be completed. This should be the priority task for next week.
*Update 1130 22 July 2019: I've now installed the required dependencies on c1iscaux3 and setup the latch.py script to run as a systemctl process dependent on modbusIOC.service. |
Attachment 1: LatchLogic.pdf
|
|
Attachment 2: LatchLogicTest.png
|
|
14789
|
Sun Jul 21 12:54:18 2019 |
gautam | Update | Loss Measurement | MC2 loss map |
Can you please be more specific about what the error is? Is this the usual instability with the camera server code? Or was it something new?
Quote: |
The camera server is throwing an error and is not grabbing snapshots :(
|
|
14788
|
Sun Jul 21 02:07:04 2019 |
Kruthi | Update | Loss Measurement | MC2 loss map |
I'm running the MC2 loss map scripts on pianosa now. The camera server is throwing an error and is not grabbing snapshots :(
Update: I finished taking the readings for MC2 loss map. I couldn't get the snapshots with the script, so I manually took some 4-5 pictures. |
14787
|
Sat Jul 20 14:43:45 2019 |
Milind | Update | Cameras | CNNs for beam tracking || Analysis of results |
<Adding details>
See Attachment #2.
Quote: |
Make the MSE a subplot on the same axes as the time series for easier interpretation.
|
Training dataset:
- Peak to peak amplitue in physical units: ?
- Dither frequency: 0.2 Hz
- Video data: zoomed in video of the beam spot obtained from GigE camera 198.162.113.153 at 500us exposure time. Each frame has a resolution of 640 x 480 which I have cropped to 350 x 350. Attachment #1 is one such frame.
- Yes, therefore I am going to obtain video at lower amplitudes. I think that should help me avoid the problem of not-nominal-maximum value?
- Other details of the training dataset:
- Dataset created from four vides of duration ~ 30, 60, 60, 60 s at 25 FPS.
- 4032 training data points
- Input (one example/ data point): 10 successive frames stacked to form a 3D volume of shape 350 x 350 x 10
- Output (2 dimensional vector): QPD readings (C1:IOO-MC_TRANS_PIT_ERR, C1:IOO-MC_TRANS_YAW_ERR)
- Pre-processing: none
- Shuffling: Dataset was shuffled before every epoch
- No thresholding: Binary images are gonna be of little use if the expectation is that the network will learn to interpret intensity variations of pixels.
Do I need to provide any more details here?
Quote |
Describe the training dataset - what is the pk-to-pk amplitude of the beam spot motion you are using for training in physical units? What was the frequency of the dither applied? Is this using a zoomed-in view of the spot or a zoomed out one with the OSEMs in it? If the excursion is large, and you are moving the spot by dithering MC2, the WFS servos may not have time to adjust the cavity alignment to the nominal maximum value.
|
?
Quote: |
What is the minimum detectable motion given the CCD resolution?
|
see attachment #4.
Quote: |
- Please upload a cartoon of the network architecture for easier visualization. What is the algorithm we are using? Is the approach the same as using the bright point scatterers to signal the beam spot motion that Gabriele demonstrated successfully
|
I wrote what I think is a handy script to observe if the frames are saturated. I thought this might be handy for if/when I collect data with higher exposure times. I assumed there was no saturation in the images because I'd set the exposure value to something low. I thought it'd be useful to just verify that. Attachment #3 has log scale on the x axis.
Quote: |
What is the significance of Attachment #6? I think the x-axis of that plot should also be log-scaled.
|
Quote: |
- Is the performance of the network still good if you feed it a time-shuffled test dataset? i.e. you have (pictures,Xcoord,Ycoord) tuples, which don't necessarily have to be given to the network in a time-ordered sequence in order to predict the beam spot position (unless the network is somehow using the past beam position to predict the new beam position).
- Is the time-sync problem Koji raised limiting this approach?
|
|
Attachment 1: frame0.pdf
|
|
Attachment 2: subplot_yaw_test.pdf
|
|
Attachment 3: intensity_histogram.mp4
|
Attachment 4: network2.pdf
|
|
14786
|
Sat Jul 20 12:16:39 2019 |
gautam | Update | Cameras | CNNs for beam tracking || Analysis of results |
- Make the MSE a subplot on the same axes as the time series for easier interpretation.
- Describe the training dataset - what is the pk-to-pk amplitude of the beam spot motion you are using for training in physical units? What was the frequency of the dither applied? Is this using a zoomed-in view of the spot or a zoomed out one with the OSEMs in it? If the excursion is large, and you are moving the spot by dithering MC2, the WFS servos may not have time to adjust the cavity alignment to the nominal maximum value.
- What is the minimum detectable motion given the CCD resolution?
- Please upload a cartoon of the network architecture for easier visualization. What is the algorithm we are using? Is the approach the same as using the bright point scatterers to signal the beam spot motion that Gabriele demonstrated successfully?
- What is the significance of Attachment #6? I think the x-axis of that plot should also be log-scaled.
- Is the performance of the network still good if you feed it a time-shuffled test dataset? i.e. you have (pictures,Xcoord,Ycoord) tuples, which don't necessarily have to be given to the network in a time-ordered sequence in order to predict the beam spot position (unless the network is somehow using the past beam position to predict the new beam position).
- Is the time-sync problem Koji raised limiting this approach?
|
14785
|
Sat Jul 20 11:57:39 2019 |
gautam | Summary | CDS | P2 interface board |
The boards arrived. I soldered on a DIN96 connector, and tested that the goemetry will work. It does . The only constraint is that the P2 interface board has to be installed before the P1 interface is installed. Next step is to confirm that the pin-mapping is correct. The pin mapping from the DIN96 connector to the DB15 was also verified.
*Maybe it isn't obvious from the picture, but there shouldn't be any space constraint even with the DB37/DB15 cables connected to the respective adapter boards. |
Attachment 1: IMG_7773.JPG
|
|
14784
|
Sat Jul 20 11:24:04 2019 |
gautam | Update | General | rossa bricked |
Summary:
SnapPy scripts made to work on Pianosa.
Details:
Of course rossa was the only machine in the lab that could run the python scripts to interface with the GigE camera. And it is totally bricked now. Lame.
So I installed several packages. The key was to install pypylon - if you go to the basler webpage, pypylon1.4.0 does not offer python2.7 support for x86_64 architecture, so I installed pypylon1.3.0. Here are the relevant lines from the changelog:
gstreamer-plugins-bad-0.10.23-5.el7.x86_64 Sat 20 Jul 2019 11:22:21 AM PDT
gstreamer-plugins-good-0.10.31-13.el7.x86_64 Sat 20 Jul 2019 11:22:11 AM PDT
gstreamer-plugins-ugly-0.10.19-31.el7.x86_64 Sat 20 Jul 2019 11:20:08 AM PDT
gstreamer-python-devel-0.10.22-6.el7.x86_64 Sat 20 Jul 2019 10:34:35 AM PDT
pygtk2-devel-2.24.0-9.el7.x86_64 Sat 20 Jul 2019 10:34:34 AM PDT
pygobject2-devel-2.28.6-11.el7.x86_64 Sat 20 Jul 2019 10:34:33 AM PDT
pygobject2-codegen-2.28.6-11.el7.x86_64 Sat 20 Jul 2019 10:34:33 AM PDT
gstreamer-devel-0.10.36-7.el7.x86_64 Sat 20 Jul 2019 10:34:32 AM PDT
gstreamer-python-0.10.22-6.el7.x86_64 Sat 20 Jul 2019 10:34:31 AM PDT
gtk2-devel-2.24.31-1.el7.x86_64 Sat 20 Jul 2019 10:34:30 AM PDT
libXrandr-devel-1.5.1-2.el7.x86_64 Sat 20 Jul 2019 10:34:28 AM PDT
pango-devel-1.42.4-1.el7.x86_64 Sat 20 Jul 2019 10:34:27 AM PDT
harfbuzz-devel-1.7.5-2.el7.x86_64 Sat 20 Jul 2019 10:34:26 AM PDT
graphite2-devel-1.3.10-1.el7_3.x86_64 Sat 20 Jul 2019 10:34:26 AM PDT
pycairo-devel-1.8.10-8.el7.x86_64 Sat 20 Jul 2019 10:34:25 AM PDT
cairo-devel-1.15.12-3.el7.x86_64 Sat 20 Jul 2019 10:34:25 AM PDT
mesa-libEGL-devel-18.0.5-3.el7.x86_64 Sat 20 Jul 2019 10:34:24 AM PDT
libXi-devel-1.7.9-1.el7.x86_64 Sat 20 Jul 2019 10:34:24 AM PDT
pygtk2-doc-2.24.0-9.el7.noarch Sat 20 Jul 2019 10:34:23 AM PDT
atk-devel-2.28.1-1.el7.x86_64 Sat 20 Jul 2019 10:34:21 AM PDT
libXcursor-devel-1.1.15-1.el7.x86_64 Sat 20 Jul 2019 10:34:20 AM PDT
fribidi-devel-1.0.2-1.el7.x86_64 Sat 20 Jul 2019 10:34:20 AM PDT
pixman-devel-0.34.0-1.el7.x86_64 Sat 20 Jul 2019 10:34:19 AM PDT
libXinerama-devel-1.1.3-2.1.el7.x86_64 Sat 20 Jul 2019 10:34:19 AM PDT
libXcomposite-devel-0.4.4-4.1.el7.x86_64 Sat 20 Jul 2019 10:34:19 AM PDT
libicu-devel-50.1.2-15.el7.x86_64 Sat 20 Jul 2019 10:34:18 AM PDT
gdk-pixbuf2-devel-2.36.12-3.el7.x86_64 Sat 20 Jul 2019 10:34:17 AM PDT
pygobject2-doc-2.28.6-11.el7.x86_64 Sat 20 Jul 2019 10:34:16 AM PDT
pygtk2-codegen-2.24.0-9.el7.x86_64 Sat 20 Jul 2019 10:34:15 AM PDT
Camera server is running on a tmux session on pianosa. But it keeps throwing up some gstreamer warnings/errors, and periodically (~every 20 mins) crashes. Kruthi tells me that this behavior was seen on Rossa as well, so whatever the problem is, doesn't seem to be because I missed out on installing some packages on pianosa. Moreover, if the server is in fact running, I am able to take a snapshot - but the camera client does not run. |
14783
|
Sat Jul 20 01:03:37 2019 |
gautam | Update | | Dataviewer error |
What channels are you trying to read?
Quote: |
I'm not able to get trends of the TM adjustment test that Rana had asked us to perform, from the dataviewer. It's throwing the following error:
Connecting to NDS Server fb (TCP port 8088)
Connecting.... done
Server error 7: connect() failed
datasrv: DataWrite failed: daq_send: Resource temporarily unavailable
T0=19-07-20-01-27-39; Length=600 (s)
No data output.
|
|
14782
|
Fri Jul 19 22:48:08 2019 |
Kruthi | Update | | Dataviewer error |
I'm not able to get trends of the TM adjustment test that Rana had asked us to perform, from the dataviewer. It's throwing the following error:
Connecting to NDS Server fb (TCP port 8088)
Connecting.... done
Server error 7: connect() failed
datasrv: DataWrite failed: daq_send: Resource temporarily unavailable
T0=19-07-20-01-27-39; Length=600 (s)
No data output. |
14781
|
Fri Jul 19 19:44:03 2019 |
gautam | Update | CDS | Database file test |
Summary:
The database files for C1ISCAUX seem to work file - the exception being the mbbo channels for the CM board.
Details:
This was just a software test - the actual functionality of the channels will have to be tested once the Acromag crate has been installed in the rack. One change I had to make on the MEDM screen for the LSC PD whitening gains was to get rid of the "NMS" suffix on the EPICS channel names for whitening gain sliders/drop-down-menus. I suspect this has to do with the EPICS version we are using, 7.0.1. Furthermore, AS165 and POP55 no longer exist - I hold off removing them from the MEDM screen for the moment.
Next steps:
From the software point of view, the major steps are:
- Fix the mbbo channel notation in the database files
- Write and test the latch enabling code
- Figure out what scripted tests can be done to test the functionality of the new Acromag box.
I am stopping the EPICS server on the new machine and restarting the old VME crate over the weekend. |
Attachment 1: Whitening.png
|
|
14780
|
Fri Jul 19 17:42:58 2019 |
gautam | Update | General | rossa Xdisp bricked |
For some reason, rossa's Xdisplay won't start up anymore. This happened right after the UPS reset. Koji and I tried ~1.5 hours of debugging, got nowhere. |
14779
|
Fri Jul 19 16:47:06 2019 |
Milind | Update | Cameras | CNNs for beam tracking || Analysis of results |
I did a whole lot of hyperparameter tuning for convolutional networks (without 3d convolution). Of the results I obtained, I am attaching the best results below.
Define "best"?
The lower the power of the error signal (difference between the true and predicted X and Y positions), essentially mse, on the test data, the better the performance of the model. Of the trained models I had, I chose the one with the lowest mse.
Attached results:
- Attachment 1: Training configuration
- Attachment 2: Predicted motion along the Y direction for the test data
- Attachment 3: Predicted motion along the Y direction for the training data
- Attachment 4: Learning curves
- Attachment 5: Error in test predictions
- Attachment 6: Video of image histogram plots
- Attachment 7: Plot of percentage of pixels with intensity over 240 with time
(Note: Attachment 6 and 7 present information regarding a fraction of the data. However, the behaviour remains the same for the rest of the data.)
Observations and analysis:
- Data:
- From attachemtns 2, 3, 5: Maximum deviation from true labels at the peaks of applied dither/motion. Possible reasons:
- Stupid Cropping? I checked (by watching the video of cropped frames, i.e visually) to ensure that the entire motion of the beam spot is captured. Therefore, this is not the case.
- Intensity variation: The intensity (brightness?) of the beam spot varies (decreases) significantly at the maximum displacement. This, I think, is creating a skewed dataset with very few frames with low intensity pixels. Therefore, I think it makes sense to even this out and get more data points (frames) with similar (lower) pixel intensities. I can think of two ways of doing this:
- Collect more data with lower amplitude of sinusoidal dither. I used an amplitude of 80 cts to dither the optic. Perhaps something like 40 is more feasible. This will ensure the dataset isn't too skewed.
- Increase exposure time. I used an exposure time of 500us to capture data. Perhaps a higher exposure time will ensure that the image of the beam spot doesn't fade out at the peak of motion.
- From attachment 5, Saturated images?: We would like to gun for a maximum deviation of 10% (0.1 in this case) from the true values in the predicted labels (Tbh, I'm not sure why this is a good baseline, I ought to give that some thought. I think the maximum deviation of the OpenCV thing I did at the start might also be a good baseline?). Clearly, we're not meeting that. One possible reason is that the video might be saturated- (too many pixels at 255, bleeding into surrounding pixles) leading to loss of information. I set the exposure time to 500us precisely to avoid this. However, I also created videos of the image histograms of the frames to make sure the frames weren't saturated (Is there some better standard way of doing it?). From attachements 6 and 7, I think it's evident that saturation is not an issue. Consequently, I think increasing the exposure time and collecting data is a good idea.
- The network:
- From attachment 4: Training post 25 epochs seems to produce overfitting, though it doesn't seem too terrible (from attachments 2 and 3). The network is still learning after 75 epochs, so I'll tinker with the learning rate, dropout and maybe put in annealing.
- I don't think there is a need to change the architecture yet. The model seems to generalize okay (valdiation error is close to training error), therefore I think it'll be a good idea to increase dropout for the fully connected layers and train for longer/ with a higher learning rate.
P.S. I will also try the 2D convolution followed by the 1D convolution thing now.
P.P.S. Gabriele suggested that I try average pooling instead of max pooling as this is a regression task. I'll give that a shot.
|
Attachment 1: readme.txt
|
Experiment file: train_both.py
batch_size: 32
dropout_probability: 0.5
eta: 0.0001
filter_size: 1
filter_type: median
initializer: Xavier
memory_size: 10
num_epochs: 75
activation_function: relu
... 22 more lines ...
|
Attachment 2: yaw_motion_test.pdf
|
|
Attachment 3: yaw_motion_train.pdf
|
|
Attachment 4: Learning_curves_replotted.pdf
|
|
Attachment 5: yaw_error_test.pdf
|
|
Attachment 6: intensity_histogram.mp4
|
Attachment 7: saturation_percentage.pdf
|
|
14778
|
Fri Jul 19 15:54:47 2019 |
gautam | Update | General | Control room UPS Batteries need replacement |
The control room UPS started making a beeping noise saying batteries need replacement. I hit the "Test" button and the beeping went away. According to the label on it, the batteries were last repalced in March 2016, so maybe it is time for a replacement, @Chub, please look into this. |
14777
|
Fri Jul 19 15:51:55 2019 |
gautam | Update | General | Projector lightbulb blown out |
[chub, gautam]
Bulb replaced. Projector is back on. |
14776
|
Fri Jul 19 12:50:10 2019 |
gautam | Update | SUS | DC bias actuation options for SOS |
Rana and I talked about some (genius) options for the large range DC bias actuation on the SOS, which do not require us to supply high-voltage to the OSEMs from outside the vacuum.
What we came up with (these are pretty vague ideas at the moment):
- Some kind of thermal actuation.
- Some kind of electrical actuation where we supply normal (+/- 10 V) from outside the vacuum, and some mechanism inside the chamber integrates (and hence also low-pass filters) the applied voltage to provide a large DC force without injecting a ton of sensor noise.
- Use the blue piers as a DC actuator to correct for the pitch imbalance --- Kruthi and Milind are going to do some experiments to investigate this possibility later today.
For the thermal option, I remembered that (exactly a year ago to the day!) when we were doing cavity mode scans, once the heaters were turned on, I needed to apply significant correction to the DC bias voltage to bring the cavity alignment back to normal. The mechanism of this wasn't exactly clear to me - furthermore, we don't have a FLIRcam picture of where the heater radiation patter was centered prior to my re-centering of it on the optic earlier this year, so we don't know what exactly we were heating. Nevertheless, I decided to look at the trend data from that night's work - see Attachment #1. This is a minute trend of some ETMY channels from 0000 UTC on 18 July 2018, for 24 hours. Some remarks:
- We did multiple trials that night, both with the elliptical reflector and the cylindrical setup that Annalisa and Terra implemented. I think the most relevant part of this data is starting at 1500 UTC (i.e. ~8am PDT, which is around when we closed shop and went home). So that's when the heaters were turned off, and the subsequent drift of PIT/YAW are, I claim, due to whatever thermal transients were at play.
- Just prior to that time, we were running the heater at close to its maximum rated current - so this relaxation is indicative of the range we can get out of this method of actuation.
- I had wrongly claimed in my discussion with Rana this morning that the change in alignment was mostly in pitch - in fact, the data suggests the change is almost equal in the two DoFs. Oplev and OSEMs report different changes though, by almost a factor of 2....
- The timescale of the relaxation is ~20 minutes - what part(s) of the suspension take this timescale to heat up/cool down? Unlikely to be the wire/any metal parts because the thermal conductivity is high?
- In the optimistic scenario, let's say we get 100 urad of actuation range - over 40m, this corresponds to a beam spot motion of ~8mm, which isn't a whole lot. Since the mechanism of what is causing this misalignment is unclear, we may end up with significantly less actuation range as well.
- I will repeat the test (i.e. drive the heater and look for drift in the suspension alignment using OSEMs/Oplev) in the afternoon - now I claim the radation pattern is better centered on the optic so maybe we will have a better understanding of what mechanisms are at play.
Also see this elog by Terra.
Attachment #2 shows the results from today's heating. I did 4 steps, which are obvious in the data - I=0.6A, I=0.76A, I=0.9A, and I=1.05A.
In science, one usually tries to implement some kind of interpretation. so as to translate the natural world into meaning. |
Attachment 1: heaterPitch_2018.pdf
|
|
Attachment 2: Screenshot_from_2019-07-19_16-39-21.png
|
|
14775
|
Thu Jul 18 22:34:40 2019 |
Koji | Summary | CDS | iscaux electronics modifications |
The whitening filter modules have been restored to the crates. The SMA cables have been restored and fastened by a spanner. The ribbon cable to the antialiasing board was also connected. The backplane cables have not been moved from the upper DIN96 connector to the lower one.
Everything is expected to be good, but just keep eyes on the LSC signals as the boards were not quantitatvely tested yet. If you find something suspicious, report on the elog. |
14774
|
Thu Jul 18 22:03:00 2019 |
Kruthi | Update | Cameras | MC2 and cameras |
[Kruthi, Yehonathan, Gautam]
Today evening, Yehonathan and I aligned the MC2 cameras. As of now there are 2 GigEs in the MC2 enclosure. For the temporary GigE (which is the analog camera's place), we are using an ethernet cable connection from the Netgear switch in 1x6. The MC2 was misaligned and the autolocker wasn't able to lock the mode cleaner. So, Gautam disabled the autolocker and manually changed the settings; the autolocker was able to take over eventually. |
14773
|
Thu Jul 18 19:58:56 2019 |
gautam | Update | CDS | Work on Acromag chassis |
Now that the .db files were prepared, I wanted to test for errors. So I did the following:
- Acromags were mounted on the DIN rails. Attachment #1 shows the grouping of ADC, DAC and BIO units. They are labelled with their IP addresses.
- Wiring of power:
- Chub had already prepared the backplane with the power connectors, switches and indicator LEDs.
- So I just had to daisy chain the +24 V (RED) and GND (BLACK) terminals for all the acromags together, which I did using 24 AWG wire (we may want to use heavier gauge given the current draw).
- Ethernet cables were used to daisy chain the network connectivity between the various units. Attachment #1 shows the current state of the chassis box.
- Front panel pieces were attached and labelled, see Attachment #2.
- I found it was sufficient to use the front - we may use the rear panel slots when we want to add connections for controlling the c1aux machine channels.
- The D15 P2 connector panel for the CM board will arrive tomorrow and will be installed then.
- Entire setup was connected to power and ethernet, see Attachment #3.
- As usual, the current draw is significant for the collection of Acromags, I got around this problem by using the bench supply to "Parallel" mode to enhance the current driving capacity.
- For the ethernet connection, I used the office space port #6, which I connected at the network rack end to the eth1 port of the Supermicro.
All the Acromags are seen on the 192.168.114 subnet on c1iscaux3 - however, when I run the modbusIOC process, I see various errors in the logfile , so more debugging is required. Nevertheless, progress.
Update 2245: Turns out the errors were indeed due to a copy/paste error - I had changed the IP addresses for the ADCs from the .115 subnet c1susaux was using, but forgot to do so for the DACs and BIOs. Now, if I turn off the existing c1iscaux so that there aren't any EPICS clashes, the EPICS server initializes correctly. There are still some errors in the log file - these pertain to (i) the mbbo notation, which I have to figure out, and (ii) the fact that this version of EPICS, 7.0.1, does not support channel descriptions longer than 28 characters (we have several that exceed this threshold). I think the latter isn't a serious problem.
Getting closer... Note that I turned off the c1iscaux VME crate to prevent any EPICS server clashes. I will turn it back on tomorrow. |
Attachment 1: IMG_7771.JPG
|
|
Attachment 2: IMG_7770.JPG
|
|
Attachment 3: IMG_7772.JPG
|
|
14771
|
Thu Jul 18 10:46:04 2019 |
gautam | Update | CDS | Database files made |
I completed the translation of the .db files for the EPICS database records from the VME notation to the Acromag/Modbus/Asyn notation. The channels are now organized into 5 database files, located in /cvs/cds/caltech/target/c1iscaux3/, for convenience:
- C1_ISC-AUX_LSCPDs.db -------- This handles whitening gain, AA enable/bypass, Demodulator FE, and PD Interface Board channels for REFL11, REFL55, REFL33, REFL165, POP22, POP110, POX11, POY11, AS55 and AS110 photodiodes.
- C1_ISC-AUX_CM.db -------------- This handles all channels for the CM board. The mbbo addressing notation needs to be checked.
- C1_ISC-AUX_QPDs.db ----------- This handles all channels for the IPPOS QPD.
- C1_ISC-AUX_ALS.db ------------- This handles all channels for the IR ALS DFD LO and RF power monitoring.
- C1_ISC-AUX_SPARE.db ---------- This handles the unused channels for the various whitening, AA and PD interface boards.
For reasons unknown to me, the database files in the other Acromag system target directories (e.g. c1susaux, c1auxex) all had 755 level access permission - maybe this is required for systemctl to handle the EPICS serving? Anyways, I upgraded the permission level of the above 5 files using chmod.
There are almost certainly typos / other errors, and I may have missed copying over some soft/calibrated channels, but I hope that this way of grouping by subsystem will make the debugging less painful. Once Chub connects up the power lines to the Acromags, I will run the soft tests. For this purpose, I've also made a C1_ISC-AUX.cmd file and a C1_ISC-AUX.env file in the above target directory, and also made the modbusIOC.service file in /etc/systemd/system on the supermicro. |
14770
|
Thu Jul 18 00:51:52 2019 |
Koji | Summary | CDS | iscaux electronics modifications |
Along with the plan in ELOG 14744, the ISC PD interface and the whitening filter board have been modificed. The ISC PD I/Fs were restored to the crate and the cables were connected. The whitening filteres are still on the electronics bench for some more tests before being returned to the crate.
The updated schematics were uploaded as https://dcc.ligo.org/D1900318 and https://dcc.ligo.org/D1900319
- Modification of the ISC PD interface: Jumpers between DIN96 P1 and P2. Replace all AD797s with OP27. In fact only I/F #1 (the left most) had total 12 AD797 but the other units already had OP27s.
- Modification of the whitening filter: Jumpers between DIN96 P1 and P2. |
Attachment 1: LSC_whitening2.jpg
|
|
Attachment 2: LSC_whitening.jpg
|
|
14769
|
Wed Jul 17 21:22:41 2019 |
gautam | Update | CDS | CM board Latch Enable subtlety |
[koji, gautam]
Koji pointed out an important subtlety pertaining to the "LATCH ENABLE" signal line on the CM board. The purpose of this line is to smoothly facilitate the transition of a change in the "multi-bit-binary-outputs", a.k.a. "mbbo", that are controlled by MEDM gain sliders, to the analog electronics on the CM board. Why is this necessary? Imagine changing the gain from 7dB (=0111 in mbbo representation) to 8dB (=1000 in mbbo representation). In order to realize this change, all 4 bits have to change their state. But this almost certainly doesn't happen synchronously, because our EPICS interface isn't synchronous. So at some intermediate times, the mbbo representation could be 0100 (=4dB), or 1111 (=15dB), or many other possible values, which are all significantly different from either the initial value or the desired final state. This is clearly undesirable.
In order to protect against this kind of error, a Latched output part, 74ALS573, is used to buffer the physical digital logic levels from the switches in the analog gain stages. So in the default state, the "LATCH ENABLE" signal line is held "LOW". When a change happens in the EPICS value corresponding to a gain slider, the "LATCH ENABLE" state is quickly toggled to "HIGH", so as to enable the appropriate analog gain stages to be switched, and then again to "LOW", at which point the latch holds its output state. This logic is currently implemented by a piece of code called "latch.o", which is the compiled version of "latch.st", which may be found in /cvs/cds/caltech/target/c1iool0 where it presumably was written for the IMC servo board, but not in /cvs/cds/caltech/target/c1iool0 , which is where the CM board database files reside. The only elog reference I can find pertaining to this particular piece of code is from Alan, and doesn't say anything about the actual logic.
For the new c1iscaux, we need to implement this logic somehow. After discussion between Koji and me, we feel that a piece of python code is sufficient. This would continuously run in the background on the supermicro server machine. The channel hierarchy for each gain channes is as follows (I've taken the example of C1:LSC-CM_REFL1_GAIN):
- C1:LSC-CM_REFL1_GAIN ------ this is the channel tied to an MEDM slider, and so is a "soft" channel
- C1:LSC-CM_REFL1_SET ------- this is a "soft" channel that gets converted to an mbbo
- C1:LSC-CM_REFL1_BITS ------ this is a channel that actually controls (multiple) physical binary outputs on the Acromag
So the logic will be that it continuously scans the EPICS channel C1:LSC-CM_REFL1_GAIN for a change in set value. When a change is detected, it has to update the C1:LSC-CM_REFL1_SET channel. In the next EPICS refresh cycle, this would result in the mbbo bits, C1:LSC-CM_REFL1_BITS , all changing to the appropriate values. After these changes have happened, we need to toggle the LATCH ENABLE in order to allow the changes to propagate to the analog gain stage switches. Need to think about what's the best way to do this. |
14768
|
Wed Jul 17 20:12:26 2019 |
Kruthi | Update | Cameras | Another GigE in place of analog camera |
I've taken the MC2 analog camera down and put another GigE (unit 151) in its place. This is just temporary and I'll put the analog camera back once I finish the MC2 loss map calibration. I'm using a 25mm focal length camera lens with it and it gives a view of MC2 similar to the analog camera one. But I don't think it is completely focused yet (pictures attached).
...more to follow
gautam - Attachment #3 is my (sad) attempt at finding some point scatterers - Kruthi is going to play around with photUtils to figure out the average size of some point scatterers. |
Attachment 1: zoomed_out_gige.png
|
|
Attachment 2: osems_mc2.png
|
|
Attachment 3: MC2.pdf
|
|
14767
|
Wed Jul 17 17:56:18 2019 |
Koji | Configuration | Computers | Gave resolv.conf to giada |
Kruthi noticed that she could not login to rossa from giada.
I checked /etc/resolv.conf and it was
nameserver 127.0.0.1
so obviously it is useless to refer localhost (i.e. giada) as a nameserver.
I copied our usual resolv.conf to giada as following:
nameserver 192.168.113.104
nameserver 131.215.125.1
nameserver 8.8.8.8
search martian
Giada's ssh known_host had unupdated entry for rossa, so I had to clean it up, but after that we can connect to rossa from giada just by "ssh rossa".
Case closed. |
14766
|
Wed Jul 17 03:05:01 2019 |
Kruthi | Update | ASS | MC spot position measurement scripts |
[Kruthi, Gautam, Rana]
Gautam installed Atom text editor on Pianosa yesterday.
MC spot position measurement scripts (these can be found in /scripts/ASS/MC directory):
- Changed the power threshold for MC2 lock loss check from 15000 to 12000 (volts) in the MeasureSpotPositions.py script. This is because, the C1:I00-MC_TRANS_SUM reads a value, usually, greater than 14000 and with 15000 as the threshold, the script will always say the MC isn't locked even though it is!. Also, to account for additional variation we have a margin of 2000.
- Issues with datetime: though MeasureSpotPositions.py was creating a .dat file, MC_spotMeasurement_history.py threw an error because the .dat file's name was not in the required format. I fixed this bug.
- Just running the MeasureSpotPositions.py doesn't enter the results into the log file, instead ./mcassMCdecenter should be run
- MC_spotMeasurement_history.py just plots the spot positions (in mm) vs days since 2013, using the log file. It still has some bugs
|
14765
|
Tue Jul 16 16:00:01 2019 |
gautam | Update | CDS | c1iscaux Supermicro setup |
I worked on preparing for the c1iscaux upgrade a bit today.
- Attachment #1: This shows where the 120 GB solid-state hard-drive and the 2 RAM cards (2GB each) are installed.
- I found that it required considerable application of force to get the RAM cards into their slots.
- Note: the 4GB RAM is broken up into two separate physical cards, each 2GB. The labeling is a bit confusing, as each card suggests it is by itself 4GB.
- OS install for c1iscaux:
- I followed Jon's instructions (and added some of mine to the wiki page to hopefully make this process even less thinking-intensive).
- To be able to use the IP address 192.168.113.83, removed "bscteststand" from chiara martian.hosts and rev.113.168.192.in-addr.arpa as the last mention I could find of this machine was from 2009 (and I'm pretty sure it isn't an active unit anymore). I then restarted the bind9 process.
- The hostname for this machine is currently "c1iscaux3" for testing purposes, I will change it once we do the actual install.
- There was an error in the installation instructions to allow incoming ssh connections - it is openssh-server that is required, not openssh-client. This has now been fixed on the wiki page instructions.
- Acromag static IP assignment:
- Assigned 2 ADCs (XT1221), 5 DACs (XT1541) and 5 sinking BIO units (XT1111) static IP addresses (and labelled them for easy reference) using the windows laptop and the Acromag IP config utility.
- I saw no reason not to use the 192.168.114.yyy scheme for the Acromag subnet on this machine, even though c1auxex and c1vac both have subnets with this addressing prefix. For reasons unknown to me, Jon opted to use 192.168.115.yyy for the c1susaux Acromag subnet.
- Followed the excellent step-by-step to install EPICS, Modbus and Asyn.
- This took a while, ~1 hour, dominated by the building of EPICS. The other two took only a couple of minutes each.
- The same combination suggested on Jon's wiki, of Modbus R2-11, EPICS base-7.0.1 and asyn4-33, are the most current at the time of installation.
- Couple of typos that prevented straight up copy-pasting were fixed on the wiki.
- Playground for testing new database files:
- made a directory /cvs/cds/caltech/target/c1iscaux3 and copied over the .db files from /cvs/cds/caltech/target/c1iscaux and /cvs/cds/caltech/target/c1iscaux2 over.
- Johannes said he did not develop any code to automate the process of translating the old .db files into the new ones for the Acromag - I won't invest the time in developing any either as I think just manually editing the files will be faster.
- I think I will follow the c1susaux convention of grouping .db files by the physical electronics system where possible (e.g. REFL11 channels in one file, CM channels in one file etc), as I think this makes for easier debugging.
- There is an old "PZT_AI.db" file which I think consists completely of obsolete channels.
- Next steps:
- Wire up the crate [Chub]
- Make the database files and modbus files for talking to the Acromags on the internal subnet [Gautam], check the .db files [Koji]
- Wiring of whitening switching from P1 to P2 connector, Issue #1 in this elog (this will also requrie the installation of the DIN shrouds) [Koji]
- Soldering of P2 interface boards [Gautam]
- Bench testing [Gautam, Koji, Chub]
- Installation and in-situ testing [Gautam, Koji, Chub]
All the required additional parts should be here by the end of the week - I'd like to aim for Wednesday 7/24 for the installation in 1Y3 and in-situ testing. While talking to Rana, I realized that we should also factor in the c1aux slow channels into this acromag crate - there is no need for a separate machine to handle the shutters and illuminators. But let's not worry about that for now, those channels can simply be added later. |
Attachment 1: IMG_7769.JPG
|
|
14764
|
Tue Jul 16 15:17:57 2019 |
Koji | HowTo | CDS | Final bit bug of the BIO CDS module |
Yutaro talked about the BIO bug in KAGRA elog. http://klog.icrr.u-tokyo.ac.jp/osl/?r=9536
I think I made the similar change for the 40m model somewhere (don't remember), but be aware of the presense of this bug. |
14763
|
Tue Jul 16 15:00:03 2019 |
gautam | Update | SUS | Multiple small EQs |
There were several small/medium earthquakes in Ridgecrest and one medium one in Blackhawk CA at about 2000 UTC (i.e. ~ 2 hours ago), one of which caused BS, ITMY, and ETM watchdogs to trip. I restored the damping just now. |
14762
|
Mon Jul 15 18:55:05 2019 |
gautam | Update | IOO | Megatron hard-rebooted |
[koji, gautam]
In addition to c1psl needing a reboot, megatron was un-ssh-able (although it was responding to ping). Clue was that the NPRO PZT control voltage was drifting a lot on the StripTool trace. Koji hard-rebooted the machine. Now IMC is locked, and FSS slow servo is also running. |
14761
|
Mon Jul 15 14:53:40 2019 |
Milind | Update | IOO | keyed psl crate, unstick.py |
Mode cleaner was not locked today. Koji came in and concluded that PSL had died. So we keyed it. Then we ran my unstick.py code. Mode cleaner is locked now.
Quote: |
Today, Gautam keyed the C1PSL crate and we got to test my unstick.py code. It seems to be working fine. Remarks:
- Gautam moved the unstick.py code to /opt/rtcds/caltech/c1/scripts/cds. Therefore, the steps to run this code are now:
- cd /opt/rtcds/caltech/c1/scripts/cds
- python unstick.py c1psl (for the c1psl machine)
- There is now a sleepTime global variable in the code which defines the amount of delay between successive channel toggles. We set this to 1ms and it took the code around 3s to run.
- Gautam was curious to see if this would work even if we set the sleepTime parameter to 0 but decided that that could be tested the next time something was keyed.
- I still need to add the signal handling thing to this code.
Following this, we tested my PMC autolocker code. The code ran for about a minute before achieveing lock. Remarks:
- Gautam moved my code (pmc_autolocker.py and autolocker_config.yaml) to /cvs/cds/rtcds/caltech/c1/scripts/PSL/PMC/ . Therefore, the steps to run this code are now:
- cd /cvs/cds/rtcds/caltech/c1/scripts/PSL/PMC/
- python pmc_autolocker.py (check code or use --help to see what the command line arguments do which is only for when you wanna override the details in the .yaml file)
- Gautam suggested that I add some delay between succesive steps of DC output adjust so that it locks quickly. I'll do that ASAP. For now, it works.
|
|
14760
|
Mon Jul 15 14:09:07 2019 |
Milind | Update | Cameras | CNN LSTM for beam tracking |
I've set up network with a CNN encoder (front end) feeding into a single LSTM cell followed by the output layer (see attachment #1). The network requires significantly more memory than the previous ones. It takes around 30s for one epoch of training. Attached are the predicted yaw motion and the fft of the same. The FFT looks rather curious. I still haven't done any tuning and these are only the preliminary results.
Quote: |
Rana also suggested I try LSTMs today. I'll maybe code it up tomorrow. What I have in mind- A conv layer encoder, flatten, followed by an LSTM layer (why not plain RNNs? well LSTMs handle vanishing gradients, so why the hassle).
|
Well, what about the previous conv nets?
What I did:
- Extensive tuning - of learning rate, batch size, dropout ratio, input size using a grid search
- Trained each network for 75 epochs and obtained weights, predicted motion and corresponding FFT, error etc.
What I observed:
- Loss curves look okay, validation loss isn't going up, so I don't think overfitting is the issue
- Training for over (even) 75 epochs seems to be pointless.
What I think is going wrong:
- Input size- relatively large input size: 350 x 350. Here, the input image size seems to be 128 x 128.
- Inadequate pre-processing.
- I have not applied any filters/blurs etc. to the frames.
- I have also not tried dimensionality reduction techniques such as PCA
What I will try now:
- Collect new data: with smaller amplitudes and different frequencies
- Tune the LSTM network for the data I have
- Try new CNN architectures with more aggressive max pooling and fewer parameters
- Ensembling the models (see this and this). Right now, I have multiple models trained either with same architecture and different hyperparameters or with different architectures. As a first pass, I intend to average the predictions of all the models and see if that improves performance.
|
Attachment 1: cnn-lstm.png
|
|
Attachment 2: fft_yaw.pdf
|
|
Attachment 3: yaw_motion.pdf
|
|
14759
|
Mon Jul 15 03:30:47 2019 |
Kruthi | Update | Calibration-Repair | White paper as a Lambertian scatterer |
I made some rough measurements, using the setup I had used for CCD calibration, to get an idea of how good of a Lambertian scatterer the white paper is. Following are the values I got:
Angle (degrees) |
Photodiode reading (V) |
Ps (W) |
BRDF (per str) |
% error |
12 |
0.864 |
2.54E-06 |
0.334 |
20.5 |
24 |
0.926 |
2.72E-06 |
0.439 |
19.0 |
30 |
1.581 |
4.65E-06 |
0.528 |
19.0 |
41 |
0.94 |
2.76E-06 |
0.473 |
19.8 |
49 |
0.545 |
1.60E-06 |
0.423 |
22.5 |
63 |
0.371 |
1.09E-06 |
0.475 |
28 |
Note: All the measurements are just rough ones and are prone to larger errors than estimated.
I also measured the transmittance of the white paper sample being used (it consists of 2 white papers wrapped together). It was around 0.002 |
Attachment 1: BRDF_paper.png
|
|
14758
|
Mon Jul 15 03:15:24 2019 |
Kruthi | Update | Loss Measurement | Imaging scatterometer |
On Friday, Koji helped me find various components required for the scatterometer setup. Like he suggested, I'll first set it up on the SP table and try it out with an usual mirror. Later on, once I know it's working, I'll move the setup to the flow bench near the south arm and measure the BRDF of a spare end test mass. |
14757
|
Sun Jul 14 00:24:29 2019 |
Kruthi | Update | Cameras | CCD Calibration |
On Friday, I took images for different power outputs of LED. I calculated the calibration factor as explained in my previous elog (plots attached).
Vcc (V) |
Photodiode
reading(V) |
Power incident on photodiode (W)
|
Power incident on GigE (W) |
|
Uncertainity in
slope (counts/𝝁s) |
CF (W-sec/counts) |
16 |
0.784 |
2.31E-06 |
3.89E-07 |
180.4029 |
1.02882 |
2.16E-15 |
18 |
0.854 |
2.51E-06 |
4.24E-07 |
207.7314 |
0.7656 |
2.04E-15 |
20 |
0.92 |
2.71E-06 |
4.57E-07 |
209.8902 |
1.358 |
2.18E-15 |
22 |
0.969 |
2.85E-06 |
4.81E-07 |
222.3862 |
1.456 |
2.16E-15 |
25 |
1.026 |
3.02E-06 |
5.09E-07 |
235.2349 |
1.53118 |
2.17E-15 |
|
Average |
2.14E-15 |
To estimate the uncertainity, I assumed an error of at most 20mV (due to stray lights or difference in orientation of GigE and photodiode) for the photodiode reading. Using the uncertainity in slope from the linear fit, I expect an uncertainity of maximum 4%. Note: I haven't accounted for the error in the responsivity value of the photodiode.
GigE area |
10.36 sq.mm |
PDA area |
61.364 sq.mm |
Responsivity |
0.34 A/W |
Transimpedance gain (at gain = 20dB) |
10^6 V/W +/- 0.1% |
Pixel format used |
Mono 8 bit |
Johannes had reported CF as 0.0858E-15 W-sec/counts for 12 bit images, with measured a laser source. This value and the one I got are off by a factor of 25. Difference in the pixel formats and effect of coherence of the light used might be the possible reasons. |
Attachment 1: CCD_calibration.png
|
|
14756
|
Fri Jul 12 18:54:47 2019 |
Koji | Update | General | Item loan: optical chopper from Cryo Lab |
Optical chopper borrowed from CryoLab to 40m
https://nodus.ligo.caltech.edu:8081/Cryo_Lab/2458 |
14755
|
Fri Jul 12 07:37:48 2019 |
gautam | Update | SUS | M4.9 EQ in Ridgecrest |
All suspension watchdogs were tripped ~90mins ago. I restored the damping. IMC is locked.
ITMX was stuck. I set it free. But notice that the UL Sensor RMS is higher than the other 4? I thought ITMY UL was problematic, but maybe ITMX has also failed, or maybe it's coincidence? Something for IFOtest to figure out I guess. I don't think there is a cable switch between ITMX/ITMY as when I move the ITMX actuators, the ITMX sensors respond and I can also see the optic moving on the camera.
Took me a while to figure out what's going on because we don't have the seis BLRMS - i moved the usual projector striptool traces to the TV screen for better diagnostic ability.
Update 16 July 1515: Even though the RMS is computed from the slow readback channels, for diagnosis, I looked at the spectra of the fast PD monitoring channels (i.e. *_SENSOR_*) for ITMX - looks like the increased UL RMS is coming from enhanced BR-mode coupling and not of any issues with the whitening switching (which seems to work as advertised, see Attachment #3, where the LL traces are meant to be representative of LL, LR, SD and UR channels). |
Attachment 1: 56.png
|
|
Attachment 2: ITMXunstick.png
|
|
Attachment 3: ITMX_UL.pdf
|
|
14754
|
Thu Jul 11 18:15:22 2019 |
gautam | Summary | Electronics | PSL/IOO rack checkout |
I looked at the PSL/IOO racks to check for which boards, if any, require an additional P2 interface, so that we can try and design a generic one for the IMC/CM boards and whatever else may require it. While searching the elog, I saw that Koji and Johannes had already done this, see Koji's elog in this thread. Some remarks:
- D990155 seems to be unused in both PSL and IOO racks. The one in the PSL rack has some LEMO cables plugged in to the front panel, but they go nowhere. So I think that both of these are redundant (in the assessment below, only one was marked redundant).
- In the PSL rack, the "TTFSS Interface", "PSL PMC SERVO", and "DAQ INTERFACE" (which I think is obsolete) cards all have their P2 connectors daisy chained together, going to a cross-connect. Kruthi and I traced this to be going to a cross connect marked "J23-PSLRACK-CCP". In the PSL wiring diagram of which we have a hardcopy in the control room, it looks like these channels are related to the RefCav? So I think this is not required to be interfaced to our new Acromag DAQ system.
Conclusion: Only the IMC Servo and CM boards need their P2 connectors connected to Acromag.It would be helpful to remove the TTFSS Interface board and figure out what exactly the pin-mapping for the backplane connectors are, but I didn't do this today because there is a "High Voltage" line going to the Interface Board and I'm not actually sure of the signal chain for the FSS servo. |
14753
|
Thu Jul 11 17:58:38 2019 |
gautam | Update | Equipment loan | TT suspension --> Downs |
Arnaud has taken 1 TT suspension from the 40m clean lab to Downs for modal testing. Estimated time of return is tomorrow evening. |
14752
|
Thu Jul 11 16:22:54 2019 |
Kruthi | Update | General | Projector lightbulb blown out |
I heard a popping sound in the control room; the projector lightbulb has blown out. |
14750
|
Thu Jul 11 13:09:22 2019 |
gautam | Summary | CDS | P2 interface board |
it will connect to a 15 pin breakout board in the Acromag chassis
Quote: |
It's nice and compact, and the cost of new 15-pin DSUB cables shouldn't be a factor here. What does the 15p cable connect to?
|
|
14749
|
Thu Jul 11 13:08:36 2019 |
Chub | Summary | CDS | P2 interface board |
It's nice and compact, and the cost of new 15-pin DSUB cables shouldn't be a factor here. What does the 15p cable connect to? |