6664
|
Tue May 22 23:36:02 2012 |
Den | Update | PEM | mircophones |
I've put 5 EM172 microphones close together and measured there signal and coherence. They are plugged in to accelerometer channels.

Then I've suspended microphones around the MC - 2 at MC2, 2 at MC1,3 and 1 at PSL. The amplifier box is above STS readout box.

Microphone close to PSL gave a strong coherence with MC_F, as we already saw it using Blue Bird Microphone.
ACC_MC2_XY channels <=> MC2 microphones
ACC_MC1_XY channels <=> MC1,3 microphones
ACC_MC1_Z channel <=> PSL microphones

|
3888
|
Wed Nov 10 22:29:42 2010 |
kiwamu | Update | IOO | misaligned the wideband EOM |
For Yuta's business, I intentionally misaligned the wideband EOM slightly to Yaw direction. Good luck.
It should show a big AM component at photo detectors.
I touched only the top right knob on the EOM mount and tweaked it by exactly 2 turns in counterclockwise direction. |
8582
|
Wed May 15 17:48:25 2013 |
Jamie | Update | CDS | misc problems noticed in models |
I noticed a couple potential issues in some of the models while I was investigating the ADC/DAC situation:
c1ioo links to ADC1, but there are broken links to the bus selector that is supposed to be pulling out channels to go into the PSL block. They're pulling channels from ADC0, which it's not connected to, which means these connections are broken. I don't know if this means the current situation is broken, or if the model was changed but not recompiled, or what. But it needs to be fixed.
c1scy connects ADC_0_11, label "ALS_PZT", to an EpicsOutput called "ALS_LASER_TEMP", which means the exposed channel is called "C1:SCY-ALS_LASER_TEMP". This is almost certainly not what we want. I don't know why it was done this way, but it probably needs to be fixed. If we need and EPICS record for this channel it should come from the ALS library part, so it gets the correct name and is available from both ends. |
4914
|
Wed Jun 29 22:50:02 2011 |
rana | Update | IOO | misc. MC work |
Today I wanted to investigate the MC Length path situation for obscure reasons.
Jamie has started to revert the "ALTPOS" effect on the MC mirrors. So far, the screens and SLOW channels have been fixed, but the fast channels still say "ALTPOS" in the dataviewer instead of "MCL".
I also noticed that all of our old ADCU channels for diagnosing the PSL, MC, ISS, PMC ,etc. are completely AWOL. Let's blame Joe.
I think that there are probably some ADC channels available and that we'll just have to figure out what Joe intended for this. We certainly need it if we want to diagnose our PMC, ISS, FSS, MC, etc. Kiwamu tells us that the old PSL/IOO AA chassis is being used for some of the GCV signals, so its likely that we just have to do the appropriate channel name mapping in the DAQCONFIG tool.
Forging ahead with no data, I made up some filters in the MC2-MCL filter bank so that there could be a stable crossover between the laser path. I was able to turn it on and get some suppression of the FSS-FAST control signal, but there's no way to be sure without the fast channels. We gotta get Jamie to help us out once he finished the ETM BO mess. |
10619
|
Thu Oct 16 21:20:59 2014 |
rana | Update | LSC | misleading modelling |
I think these are all very helpful and interesting plots. We should see some better performance using either of the DC DARM signals.
BUT, what we really need (instead of just the DC sweeps) is the DC sweep with the uncertainty/noise displayed as a shaded area on the plot, as Nic did for us in the pre-CESAR modelling.
Otherwise, the DC sweeps mistakenly indicate that many channels are good, whereas they really have an RMS noise larger than 100 pm due to low power levels or normalization by a noisy signal. |
5048
|
Wed Jul 27 15:42:41 2011 |
kiwamu | Summary | General | mitues of 40m meeting : Task list |
Quote: |
The vent will start from 1 st of August !
|
++++ Task List for the vent preparation ++++
+ Preparation of beam dumps (Jamie / Steve)
+ Health check of shadow sensor and measurement of the cross-coupling (Steve)
+ Measurement of the arm Lengths and estimation of the required precision (Kiwamu)
+ Alignment of the Y green beam (Suresh)
+ Alignment of the incident beam axis (Jenne)
+ Measurement of the MC spot positions (Suresh)
+ Loss measurement of the arm cavities (Kiwamu / volunteers)
++++ Task List for the post-vent activity ++++
+ 3f RFPDs (Koji / Rana)
+ EOM resonant circuit (Kiwamu)
+ Sophistication of the LSC model (Yoichi)
+ DRMI commissioning (Keiko / Anamaria)
|
4253
|
Fri Feb 4 23:39:56 2011 |
rana, koji | Update | LSC | mixer based FD set up for noise test |
We set up the mixer based FD to check out its noise performance.
It is being acquired as C1:GCV-XARM_FINE_OUT_DAQ.
We have calibrated it by driving the frequency of the RF signal generator and putting the value into the GAIN field. We got 100 kHz / 5450 counts; the _OUT_DAQ channel is now being recorded in units of Hz. The cable length has been adjusted so that the full mixer output can swing 16 MHz peak-peak before turning over.
Also, we did a lot of cable cleanup around the IO rack. Kiwamu and Suresh's setups were somewhat dismantled. The whole area was too messy and too hacky to be allowed to survive. Our "temporary" setups have a way of becoming permanent holding places for barrels, adapters, duct tape, etc. |
1477
|
Mon Apr 13 08:59:57 2009 |
steve | Update | PSL | mixers on order |
Quote: |
Quote: |
I then changed the RF Output Adjust slider in increments of 0.5, and measured the peak-to-peak values on the scope. In the table and on the plots, I've taken into account the 12dB attenuation. i.e I actually measured 964mV, so 964mV*10^.6 = 3838mV.
|
3.8Vpp is about 16dBm.
The mixer for the PMC demodulator is level 23. So 16dBm is insufficient.
What is the level of the new mixer Steve ordered ? 13 ? |
I ordered mixers level 13, 17 on Friday and level 23 now.
They should be here Tuesday
NOTE: level 23 power is illegal to use in the 40m lab
They get hot |
14282
|
Wed Nov 7 19:17:18 2018 |
Jon | Omnistructure | | modbusIOC is running on c1vac replacement |
Today I finished setting up the server that will replace the c1vac1/2 machines. I put it on the martian network at the unassigned IP 192.168.113.72. I assigned it the hostname c1vac and added it to the DNS lookup tables on chiara.
I created a new targets directory on the network drive for the new machine: /cvs/cds/caltech/target/c1vac. After setting EPICS environment environment variables according to 13681 and copying over (and modifiying) the files from /cvs/cds/caltech/target/c1auxex as templates, I was able to start a modbusIOC server on the new machine. I was able to read and write (soft) channel values to the EPICS IOC from other machines on the martian network.
I scripted it as a systemd-managed process which automatically starts on boot and restarts after failure, just as it is set up on c1auxex. |
14580
|
Fri Apr 26 12:32:35 2019 |
Jon | Update | PSL | modbusPSL service shut down |
Gautam and I are removing the prototype Acromag chassis from the 1x4 rack to make room for the new c1susuax hardware. I shut down and disabled the modbusPSL service running on c1auxex, which serves the PSL diagnostic channels hosted by this chassis. The service will need to be restarted and reenabled once the chassis has been reinstalled elsewhere. |
3015
|
Sun May 30 15:33:21 2010 |
Alberto | Configuration | IOO | mode cleaner and air conditioning |
The mode cleaner is locked and the air conditioning is full on. So the the air conditioning doesn't seem to be so important for the lock to hold. |
67
|
Tue Nov 6 10:42:01 2007 |
rob | Configuration | IOO | mode cleaner locked |
Increased the power exiting the PSL by turning the half-wave plate after the MOPA, opened the PSL shutter, and aligned the mode cleaner to the input beam. It wasn't that hard to find the beam with the aperture open all the way on the MC2 camera. The transmitted power is now 2.9 arbitrary units, while the input power is 1.2 arbitrary units. Not sure yet if that's an increase or decrease in efficiency, since no one posted numbers before the vent. Also turned on the input-steering PZTs and saw a REFL beam on the camera. |
1125
|
Mon Nov 10 11:06:09 2008 |
rob | HowTo | IOO | mode cleaner locked |
I found the mode cleaner unlocked, with (at least) MC1 badly mis-aligned. After checking the coil alignment biases and finding everything there looking copasetic, I checked the trends of SUS{PIT,YAW,POS} and found that both MC1 and MC3 took a step this morning. The problem turned out to be loosed/jiggled cables at the satellite amplifiers for these suspensions. Giving them a good hard push to seat them restored the alignment and the mode cleaner locked right up. |
8530
|
Mon May 6 19:04:30 2013 |
Jamie | Update | IOO | mode cleaner not locking |
About 30 minutes ago the mode cleaner fell out of lock and has since not been able to hold lock for more than a couple seconds.
I'm not sure what happened. I was in the middle of taking measurements of the MC error point spectrum, which included adjusting the FAST gain. I've put all the gains back to their nominal levels but no luck. I'm not sure what else could have gone wrong. Seismic noise looks relatively quiet. |
8531
|
Mon May 6 21:05:06 2013 |
rana, Jamie, KOji | Update | IOO | mode cleaner not locking |
As it turned out, the setting of +26dB for the FSS Fast gain was making the NPRO PZT / Pockels cell crossover too unstable. This was the cause of the large ~30 kHz peak that Jamie was seeing in his spectra (more to follow in the morning).
After recovering the locking, etc. by fiddling with the gains, we went about systematically setting all of the gains/offsets. Jamie's elog will show all of the various spectra with different FSS gains.
For offset setting, this was the procedure:
- We want the MC servo board to have zero voltage on its MCL and MCF outputs (aka MC_SLOW_MON and MC_FAST_MON) with the Boosts ON, so we switched ON the 40:4000 and the 2 Super Boosts and put the VCO gain into its nominal +25 dB setting. This saturates the outputs and makes them impossible to use as readbacks so you have to be careful. Get the outputs close to zero as you turn on each boost. Finally, you will see that +/- 1mV of input offset (aka MC_REFL_OFFSET) will flip the FAST output between +/- 10V. This is the right setting.
- With the MC board adjusted to send 0 V into the FSS error point, adjust the FSS input offset (with the Common and Fast gains at the nominal values) so that the FAST output voltage goes to +5.5 V. This is the middle of the range for the high voltage driver which drives the NPRO.
-
Let the MC lock and go through the UP script. When the MCL comes on with the integrator, the FAST voltage will shift from +5.5 V to something else. Use the following line: ezcaservo -r C1:PSL-FSS_FAST -g -1 -s 5.5 C1:SUS-MC2_MCL_OFFSET, to automatically tune the MCL offset.
That's all. I have left the FSS common gain at +10.5 and the Fast gain at +23.5. These seem to be close to the optimum. Jamie will have more tuning tomorrow.
I have also changed the 'mcup' script to set the MCL offset and set the FSS Slow setpoint to shoot for +5.5 V of FSS_FAST.
MC_REFL_OFFSET = +1.176 V
MC2_MCL_OFFSET = +47.8 counts
FSS_INOFFSET = -0.85 V
|
9148
|
Fri Sep 20 20:27:18 2013 |
rana | Update | IOO | mode cleaner not locking |
I used our procedure from this entry to set the IMC board offset as well as the FSS board offset.
I found this afternoon that the MC was having trouble locking: the PC path was railing as soon as the boost was engaged. Could be that there's some misalignment on the PSL which has led to some RAM having to be canceled by this new offset. Let's see if its stable for awhile. |
9153
|
Sun Sep 22 22:54:28 2013 |
rana | Update | IOO | mode cleaner not locking |
Having trouble again, starting around 1 hour ago. No one in the VEA. Adjusted the offset -seems to be OK again. |
9431
|
Sat Nov 30 23:50:28 2013 |
rana | Update | IOO | mode cleaner not locking |
Quote: |
I used our procedure from this entry to set the IMC board offset as well as the FSS board offset.
I found this afternoon that the MC was having trouble locking: the PC path was railing as soon as the boost was engaged. Could be that there's some misalignment on the PSL which has led to some RAM having to be canceled by this new offset. Let's see if its stable for awhile.
|
I felt in my bones that the MC was in trouble so I came by and noticed that it hadn't locked for a couple hours. The FSS SLOW was at -1.6V, but putting it back to zero didn't fix things. I adjusted the FSS error point offset to +1 and that took the FSS_FAST off of the +10 V rail. Relocked and seems OK.
We need to plan to make the M Evans mod to the FSS box to make the PC drive less angry.
Last 40 days of MC Alignment trends show that the recent MC WFS tuning / offseting worked out OK. MC REFL seems low and flat. |
Attachment 1: mcdrift.png
|
|
3548
|
Thu Sep 9 05:58:04 2010 |
kiwamu | Update | PSL | mode matching from PMC to IMC |
I started mode matching of the beam going to IMC. The work is still going on.
According to Rana's calculation (see here), I put the first lens (f=200mm) in between two steering mirrors after PMC.
The distance from PMC to the first lens was adjusted by using a metal ruler. So I believe the accuracy is something like 1mm.
I aligned the beam path going through the broadband EOM and the mode matching lenses.
I could find the optimum position for the second lens (f=-150mm) by sliding the position of the lens and measuring the mode after it.
But the optimum position looked a bit far from the EOM. It's off by about 3-4 inch from the designed position.
Somehow I feel that the beam before the second lens goes with a smaller divergence angle than that of designed.
So tomorrow I am going to restart the work from checking the mode before the second lens.
Maybe at first I should measure the mode without going through the EOM because it changes the waist position and makes the system not straightforward. |
3566
|
Mon Sep 13 11:49:34 2010 |
kiwamu | Update | PSL | mode matching from PMC to IMC |
I have been working on the mode matching lenses which are sitting after the boradband EOM.
Last Friday I checked the mode profile after the first mode matching lens (f=-150mm). The measured mode was good.
According to the calculation done by ABCD software, the waist size is supposed to be 80.9 um after that lens.
The measured waists are 80.5 um for the vertical mode and 79.4 um for the horizontal mode.
The screenshot of the ABCD's result and the plot for the mode measurement are shown below.
I didn't carefully check the mode after the last convex lens (f=200mm), but it must be already good because the beam looks having a long rayleigh range.
Now the beam is reflected back from MC1 and goes to the AP table since I coarsely aligned the beam axis to the MC.

/**** fitting result ****/
w0_v = 80.4615 +/- 0.1695 [um]
w0_h = 79.4468 +/- 0.1889 [um]
z_v = -0.115234 +/- 0.0005206 [m]
z_h = -0.109722 +/- 0.0005753 [m]
|
3068
|
Fri Jun 11 14:31:04 2010 |
kiwamu | Update | IOO | mode matching of new IOO |
We decided not to care about the mode after MMT1.
So far Koji, Alberto and I have measured the beam profile after MMT1,
but we are going to stop this measurement and go ahead to the next step i.e. putting MMT2
There are two reasons why we don't care about the profile after MMT1:
(1) it is difficult to fit the measured data
(2) The position of MMT1 is not critical for the mode matching to the IFO.
The details are below.
(1) difficulty in fitting the data
The precision of each measured point looked good enough, but the fitting result varies every measurement.
The below shows the data and their fitted curves.

In the label, "h" and "v" stand for "horizontal" and "vertical" respectively.
The solid curves represent the fitting results, varying by each measurement.
In order to increase the reliability of the fitting, we had to take some more data at further distance.
But we couldn't do it, because the beam radius already becomes 3 mm even at 2 m away from MMT1 and at this point it starts to be clipped on the aperture of the beam scan.
Thus it is difficult to increase the reliability of the fitting.
Once if we put MMT2 the beam should have a long Rayleigh range, it means we can measure the profile at further distance, and the fitting must be more reliable.
(2) positioning of MMTs
Actually the position of MMT1 is not so critical for the mode matching.
The most important point is the separation distance of MMT1 and MMT2.
As written in Jenne's document, if we slide the positions of MMT1 and MMT2 while keeping their appropriate separation distance, the mode match overlap still stays above 99%
This is because the beam coming from MC3 is almost collimated (ZR~8m), so the position of MMTs doesn't so matter.
To confirm it for the real case, I also computed the mode overlap while sliding the position of MMTs by using real data. The below is the computed result.

It is computed by using the measured profile after MC3 (see the past entry).
The overlap still stay above 99% when the distance from MC to MMT is between 1300 and 3000mm.
This result suggests to us putting MMT1 as we like. |
3695
|
Tue Oct 12 01:54:32 2010 |
kiwamu | Update | Green Locking | mode matching to doubling crystal on PSL table |
I improved the mode matching of the incident beam to the doubling crystal on the PSL table.
As a result it apparently got better (i.e. brighter green beam), but it's not the best because now the beam is a little too tightly focused on the crystal. 
I am going to work on it again someday after seeing the beat note signal.
- The measured waist sizes are
41.94 [um] for vertical mode
42.20 [um] for horizontal mode
while the optimum waist size is 50 um (see entry #3330).
The plot below shows the beam scan data which I took after improving the mode match.

|
3029
|
Wed Jun 2 01:47:28 2010 |
Alberto, Kiwamu | Update | IOO | mode measurement of new input optics |
The mode profile of the new input optics was measured.
Although the distance between each optic was not exactly the same as the design because of narrow space,
we measured the profile after the curved mirror (MMT1) that Jenne and Kevin put in the last week.
(interference from MMT1)
Below is a sketch of the current optical path inside of the chamber.

In the beginning of this measurement, the angle between the incident and the reflection on MMT1 (denoted as theta on the sketch) was relatively big (~40deg) although MMT1 was actually made for 0deg incident.
At that time we found a spatially large interference imposed on the Gaussian beam at the beam scan. This is not good for mode measurement
This bad interference can be caused by an extra reflection from the back surface of MMT1 because the interference completely vanished by removing MMT1 .
In order to reduce the interference we decreased the angle theta as small as possible. Actually we made it less than 10deg which was our best due to narrow space.
Now the interference got less and the spot looks better.
The picture below shows an example of the beam shape taken by using the beam scan.
Top panel represents the horizontal mode and bottom panel represents the vertical mode.
You can see some bumps caused by the interference on the horizontal mode, these bumps may lead to overestimation of the horizontal spot size .
(result)

The above plot shows the result of the mode measurement.
Here are the parameter obtained by fitting. The data is also attached as attachment:4
waist size for vertical |
w0v [mm] |
0.509 +/-0.0237 |
waist size for horizontal |
w0h [mm]
|
0.537 +/- 0.0150 |
waist position from MMT1 for vertical |
xv[m] |
-2.91 +/- 0.214 |
waist position from MMT1 for horizontal |
xh[m] |
-2.90 +/- 0.127 |
|
Attachment 3: MMT1_.dat.zip
|
3031
|
Wed Jun 2 03:50:03 2010 |
Koji | Update | IOO | mode measurement of new input optics |
Just note that MMT1 has RoC of -5m (negative!). This means that it is a lens with f=-2.5 m,
|
3043
|
Thu Jun 3 13:14:27 2010 |
kiwamu | Update | IOO | mode measurement of new input optics |
I corrected the sketch of the new IOO.
The sketch in the last entry was also replaced by the new one.
http://nodus.ligo.caltech.edu:8080/40m/3029
Quote: |
Just note that MMT1 has RoC of -5m (negative!). This means that it is a lens with f=-2.5 m,
|
|
Attachment 1: inside_vac_2.png
|
|
3044
|
Thu Jun 3 14:01:51 2010 |
kiwamu | Update | IOO | mode measurement of new input optics |
I checked the measured data of the mode profile which was taken on the last Tuesday.
For the vertical profile,
the plot shows a good agreement between the expected radius which is computed from the past measurement, and that measured on the last Tuesday.
However for the horizontal profile,
it looks like being overestimated. This disagreement may come from the interference imposed on the Gaussian spot as we've been worried.
So I guess we should solve this issue before restarting this mode matching work.
- The next step we should do are;
checking the effect of MMT1 on the shape of the beam spot by using a spare of MMT1
NOTE:
The expected curve in the attached figure were computed by using the fitted parameter listed on the entry 2984 .
In the calculation the MMT1 is placed at 1911mm away from MC3 as we measured.
And the focal length of MMT1 is set to be f=-2500mm. |
Attachment 1: check_measurement_edit.png
|
|
3045
|
Thu Jun 3 14:13:20 2010 |
Jenne | Update | IOO | mode measurement of new input optics |
Quote: |
I checked the measured data of the mode profile which was taken on the last Tuesday.
For the vertical profile,
the plot shows a good agreement between the expected radius which is computed from the past measurement, and that measured on the last Tuesday.
However for the horizontal profile,
it looks like being overestimated. This disagreement may come from the interference imposed on the Gaussian spot as we've been worried.
So we should solve this issue before restarting this mode matching work.
- The next step we should do are;
checking the effect of MMT1 on the shape of the beam spot by using spare MMT1
NOTE:
The expected curve in the attached figure were computed by using the fitted parameter listed on the entry 2984 .
In the calculation the MMT1 is placed at 1911mm away from MC3 as we measured.
And the focal length of MMT1 is set to be f=-2500mm.
|
When / if you use the other MMT1 mirror, make sure to take note whether or not it says "SPARE" on it in pencil. I don't remember if it's the other MMT1, or if it's one of the MMT2's that says this. The mirror was baked, so it's okay to use in the vacuum, however it's the one which was dropped on the floor (just prior to baking), so any discrepancies measured using that optic may not be useful. I don't know how strong the CVI coatings are to scratches resulting in being dropped from a ~1m height. Bob and I didn't see any obvious big scratches that day, but that doesn't necessarily give it a clean bill of health.
The optic labeled "SPARE" should NOT be used as the final one in the IFO. |
3046
|
Thu Jun 3 14:40:28 2010 |
Alberto, Kiwamu | Update | IOO | mode measurement of new input optics |
Quote: |

|
For the record, we wanted to check whether the fringes on the beam spot were caused by SM2 (see diagram above). We tried two different mirrors for SM2,
The first was one of the flat, 45 degree ones that were already on the BS table. The last, which is the one currently in place, was inside the plastic box with the clean optics that Jenne left us .
The fringes were present in both cases. |
2959
|
Thu May 20 13:29:40 2010 |
kiwamu | Update | Green Locking | mode profile at PPKTP crystal |
I measured again the mode profile of the beam going through the PPKTP crystal by using the beam scan.
The aimed beam waist is 50 um (as described in entry 2735),
and the measured profile had pretty good waist of wx=51.36 +/- 0.0999 um and wy=49.5 +/- 0.146 um 
The next things I have to do are - (1). re-optimization of the temperature of the crystal (2). measurement of the conversion efficiency
The attached figure is the result of the measurement. |
Attachment 1: PPKTPmode.png
|
|
2960
|
Thu May 20 14:18:59 2010 |
kiwamu | Update | Green Locking | mode profile of 40m cavity |
The mode profile of the green beam going through 40m cavity was measured.
According to the fitting the coupling efficiency to the cavity is 98.46% , but still the beam looks loosely focused .
This measurement has been done by using the oplev legs (entry #2957) to allow the beam to go through the 40m walkway.
With a beam scan set on a movable cabinet, I measured it along the 40m chamber.
Since the plot looks not so nice, I am going to work on this measurement a little bit more after I improve the mode matching.
Here is the parameters from the fitting
target waist [mm] |
2.662 |
measured waist x [mm] |
2.839 |
measured waist x [mm]
|
3.111 |
|
|
target waist position [m] |
43.498 |
measured waist position x [m] |
42.579 |
measured waist position y [m] |
38.351 |
I believe the error for the travel length was within 0.5 meter. The length was always measured by a tape measure.
A thing I found was that: spatial jittering of the beam gets bigger as the beam goes further. This is the main source of the error bar for the spot size.
|
Attachment 1: MMT40mcavity.png
|
|
6437
|
Thu Mar 22 17:35:59 2012 |
kiwamu | Update | Locking | mode profiles of the POP and POX beams : not bright enough |
I tried to measure the beam profiles at the POP and POX ports as Koji mentioned in his entry (#6421).
However it turned out that the beam powers were too small to be measured with our beam scan at those ports.
So I will move on to measurements at the REFL port as Rana suggested because the laser power is much larger than that of POP and POX.
(If the data of the POP and POX beam profiles turn out to be very necessary, we will do the razor blade technique with a more sensitive photo diode)
Quote from #6421 |
More precise analysis can be done with quantitative analysis of those two spots with Beamscan. This could happen tomorrow.
|
|
6446
|
Mon Mar 26 18:04:43 2012 |
kiwamu | Update | IOO | mode scan at the REFL port |
For those who are interested in the actual data, I attache the actual data in zip file together with a python plot code.
The distance was set such that the 1st steering mirror (the one at the very left in the previous cartoon diagram #6445 ) in the REFL path is positioned at zero.

- - - Fitting results (chi-square fitting done by gnuplot):
All values are in unit of meter
# PRM (v) (Last tree points are excluded as the beam were clipped at the aperture of the beam scan)
w0 = 0.0015114 +/- 2.192e-05 (1.451%)
z0 = -4.46073 +/- 0.05605 (1.256%)
# PRM (h)
w0 = 0.00212796 +/- 1.287e-05 (0.6049%)
z0 = -2.53079 +/- 0.1688 (6.668%)
# ITM (v) (Last two points are excluded as the beam were clipped at the aperture of the beam scan)
w0 = 0.00190696 +/- 4.964e-05 (2.603%)
z0 = -8.09908 +/- 0.1525 (1.882%)
# ITM (h)
w0 = 0.0032539 +/- 4.602e-05 (1.414%)
z0 = -1.89484 +/- 1.524 (80.42%)
|
Attachment 2: REFLmodescan.zip
|
8720
|
Wed Jun 19 01:12:42 2013 |
Jenne | Update | ASC | model name ASS -> ASC ??? |
I am proposing a model name change. Currently, we have an "ASS" model, but we do not have an "ASC" model.
The ASS is currently using ~17 of 60 available microseconds per cycle. So, we have some cpu overhead available to put more stuff on that cpu. Like, say, ASC stuff.
So, my proposal is that we change the ASS model name to "ASC", and put all of the ASS-y things in a top_names block, so we retain the current channel names. The IOO top_names block that is in the current ASS model (which is there to send signals to the LSC DAC for the input tip tilts, even though the names need to be IOO) should obviously stay on the top level, so that things in there retain their names.
Then, I can make a new top_names sub-block for ASC-like things, such as the new POP QPD.
Inside the ASC block (in the ASC model), I'm currently thinking something simple will do..... QPD inputs, going to a matrix, which outputs to the filter banks in the "length" degree of freedom basis (PRCL, SRCL, etc), then another matrix, going to the ASC suspension paths.
So, for example, the POP QPD pitch would go to the PRCL_PIT filter bank, and then on to the PRM_ASCPIT path in the SUS screen.
Or, in another example case, IPPOS yaw would go to an input pointing filter bank, then on to TT1's yaw slider.
EDIT: After a few minutes of thinking, I think I also want triggering, and perhaps filter bank triggering, in the ASC model. One of the reasons Koji has been pushing for the new automation system is that when the PRC fell out of lock, the ASC path would kick the PRM until Koji ran a down script. Triggering will fix this issue, and it's the kind of thing that needs to happen quickly, so may not really be appropriate for the Guardian anyway. |
8723
|
Wed Jun 19 04:56:07 2013 |
Koji | Update | ASC | model name ASS -> ASC ??? |
Sounds good.
Or we just stuff any angle control things in to Angular Stabilization System without changing the model name.
The process name itself is not a big deal. |
7038
|
Thu Jul 26 13:10:51 2012 |
janosch | Update | LSC | modelled ringdown |
We fitted shutter and ringdown functions to the ringdown data. It is not perfectly clear how the power change due to the shutter is handed over to the power change due to ringdown. The fit suggests that the ringdown starts at a later time, but this does not necessarily make sense. It could be that the slow power decrease when the shutter starts clipping the TEM00 beam is followed by the cavity, but then the power decrease becomes too fast when the shutter reaches the optical axis and the ringdown takes over. Also, the next measurement should be taken with adjusted DC offset.

|
7039
|
Thu Jul 26 15:43:03 2012 |
rana | Update | LSC | modelled ringdown |
You cannot use the digital system for this. You hook up a scope to the transmitted light as well as the incoming light (after the MC, perhaps at IP_POS). Then you acquire the data from both places simultaneously using an ethernet equipped scope. The step response of the PDs used for this has to be calibrated separately. |
5711
|
Thu Oct 20 11:59:21 2011 |
Zach | Update | Computer Scripts / Programs | modified "dataviewer" on nodus |
The "dataviewer" script was still setting the server to fb40m on nodus. I modified it to fb, so that this is the default when you enter "dataviewer" or "dv". |
4949
|
Wed Jul 6 23:03:57 2011 |
kiwamu | Update | LSC | modified locking scripts |
[Jenne / Kiwamu]
Last night we modified the locking scripts, that were called from C1IFO_CONFIGURE.adl, to adapt them to the new "PRCL" and "SRCL" convention.
So far they work fine and quitted dumping some error messages about inexistence of these channel names.
P.S. The locking scripts have been summarized on the 40m wiki
Quote from #4912 |
- Now the power and signal recycling cavity lengths are named "PRCL" and "SRCL" in stead of three letter names without "L".
We should change the locking script to accomodate these changes.
|
|
9324
|
Thu Oct 31 21:22:00 2013 |
rana, koji | Summary | IOO | modulation beat note in MC servo |
I hooked up the 4395 to the MC servo board test out (TP2A) and looked at the spectrum using our new SPAG4395.py script. We noticed a huge peak at ~3.8 MHz and correctly guessed that it was due to the beat between the MC modulation frequency 29.5 MHz and 3*f1 (~33 MHz).
So we tuned the Marconi for the main mod. from 11065910 to 11066099 Hz and saw the beat note disappear (to within the 1 Hz tuning precision of our Marconi).
New MC length tuning method! Alert the LA Times!
  
My conjecture is that this temperature dependent mismatch between the modulation frequency (f1) and the MC length is what leads sometimes to our nasty saturating PC DRIVE signal. TBD. |
11036
|
Mon Feb 16 01:45:12 2015 |
Koji | Summary | LSC | modulation depth analysis |
Based on the measured modulation profiles, the depth of each modulation was estimated.
Least square sum minimization of the relative error was used for the cost function.
-8th, -12th~-14th, n=>7th are not included in the estimation for the nominal case.
-7th~-9th, -11th~-15th, n=>7th are not included in the estimation for the 3f reduced case.
Nominal modulation
m_f1 = 0.194
m_f2 = 0.234
theta_f1f2 = 41.35deg
m_IMC = 0.00153
3f reduced modulation
m_f1 = 0.191
m_f2 = 0.0579
theta_f1f2 = 180deg
m_IMC = 0.00149
(Sorry! There is no error bars. The data have too few statistics...) |
Attachment 1: modulation_nominal.pdf
|
|
Attachment 2: modulation_3f_reduced.pdf
|
|
6027
|
Mon Nov 28 16:51:57 2011 |
kiwamu | Update | LSC | modulation frequency reset |
I reset the modulation frequency to 11065910 Hz (#5530). It had been at 11065399 Hz probably since the power shut down. |
240
|
Wed Jan 16 14:06:24 2008 |
rob | Update | LSC | monday's locking |
rob, tobin, johnnie
We did some locking work monday night, with decent progress. Working in the PRFPMI style, we managed to get through the part of the script that hands off the offset-CARM DOF to the MCL, but were not successful in engaging the AO path.
We also confirmed the problem with tdsread which prevent it from reading from multiple TLS (Three Lettered Subsystems) at the same time. Tobin traced this to a problem with the ezca library which tds uses, but it's not clear how to fix it. For now we just split the tdsread calls so that there are no multiple TLS calls. Tobin will report further on this. |
12667
|
Tue Dec 6 00:43:41 2016 |
gautam | Update | IMC | more IMC ringdowns |
In an effor to see if I could narrow down the cause of the 100kHz ringing seen in the reflected PD signal, I tried a few things.
- Changed the PD - there was a PDA 255 sitting on the PSL table by the RefCav. Since it wasn't being used, I swapped the PD I was using with this. Unfortunately, this did not solve the problem.
- Used a different channel on the oscilloscope - ringing persisted
- Changed BNC cable running from PD to oscilloscope - ringing persisted
- Checked the spectrum of the PD under dark and steady illumination conditions for any features at 100kHz, saw nothing (as expected)
I was working under the hypothesis that the ringing was due to some impedance mismatch between the PD output and the oscilloscope, and 4 above supports this. However, most documents I can find online, for example this one, recommend connecting the PD output via 50ohm BNC to a scope with input impedance 50ohms to avoid ringing, which is what I have done. But perhaps I am missing something.
Moreover, the ringdown in reflection actually supplies two of the five variables needed to apply the MIT method of loss estimation. I suppose we could fit the parameter "m4" from the ringdown in transmission, and then use this fitted value on the ringdown in reflection to see where the reflected power settles (i.e. the parameter "m3" as per the MIT paper). I will try analyzing the data on this basis.
I also measured the power levels at each of the PDs, these should allow us to calibrate the PD voltage outputs to power in Watts. All readings were taken with the Ophir power meter, with the filter removed, and the IMC locked.
PD |
Power level |
REFL |
0.47 mW (measured before 1.0 ND filter) |
Trans |
203 uW |
Incident |
1.06 mW |
|
6264
|
Thu Feb 9 17:11:05 2012 |
steve | Update | SUS | more OSEM problems |
These observations of the OSEMs were taken while taking transfer functions of oplev YAW at excitation amplitude 0.1
Atm1, C1:SUS-ETMX_SENSOR_SIDE cross coupling
Atm2, C1:SUS-ITMX_SENSOR_LL not excitable
Atm3-4, BS and PRM insensitive
Good OSEM list: ITMY, ETMY and SRM
|
Attachment 1: ETMXosemEXC0.1ampl.png
|
|
Attachment 2: IMTX-YAW0.1.png
|
|
Attachment 3: BSosemEXC.1ampl.png
|
|
Attachment 4: PRMosemEXC.1ampl.png
|
|
10172
|
Thu Jul 10 01:02:13 2014 |
rana | Update | PSL | more PMC science |
Increased gain and SNR in PMC LO monitor circuit.
- R20: 499 -> 50k Ohms (increases gain by 100)
- Used Marconi to drive the LO input and readout C1:PSL-PMC_LODET
- Fit this function and loaded it into the psl.db file. The old Kalmus way used LOGE, but I wanted to use log10, so I did. The sensor is only useful in a narrow band. Since the signal is so low at low levels, I just fit to the highest 4 points because I was too lazy to do proper weighting. Do as I say, not as I do.
Plot with data and fit attached.
** N.B.: in order to update the calibration without rebooting, I used the following command: z write C1:PSL-PMC_LOCALC.CALC "2.235*LOG(B)+12.265". This allows us to update EPICS CALC records without rebooting the IOC. |
Attachment 1: PMCloCal.pdf
|
|
15849
|
Sun Feb 28 16:59:39 2021 |
rana, gautam | Update | LSC | more PRMI checks here: what it is ain't exactly clear |
On Friday evening we checked out a few more things, somewhat overlapping with previous tests. All tests done with PRMI on carrier lock (REFL11_I -> PRC, AS55_Q-> MICH):
- check that PRC drive appropriately minimizes in REFL55_Q. I:Q ratio is ~100:1; good enough.
- put sine waves around 311 and 333 Hz into PRCL and MICH at the LSC output matrix using awggui and LSC osc. not able to adjust LSC/OSC output matrix to minimize the MICH drive in REFL_I.
- measured the TF from BS & PRM LSC drive to the REFL55_I/Q outputs. very nearly the same audio frequency phase, so the problem is NOT in the electronics || mechanical transfer functions of the suspensions.
Further questions:
- is this something pathological in the PRMI carrier lock? we should check by locking on sidebands to REFL55 and REFL165 and repeat tests.
- Can it be a severe mode mismatch from IMC output to PRMI mode? the cavity should be stable with the flipped folding mirrors, but maybe something strange happening. How do we measure the mode-matching to the PRC quantitatively?
- huge RAM is ruled out by Gautam's test of looking at REFL demod signals: dark offset vs. offset with a single bounce off of PRM (with ITMs mis-aligned)
- if there is a large (optical) offset in the AS55_Q lock point, how big would it have to be to mess up the REFL phase so much?
- what is going on with the REFL55 whitening/AA electronics?
unrelated note: Donatella the Workstation was ~3 minutes ahead of the FE machines (you can look at the C0:TIM-PACIFIC_STRING on many of the MEDM screens for a rough simulacrum). When the workstation time is so far off, DTT doesn't work right (has errors like test timed out, or other blah blah). I installed NTP on donatella and started the service per SL7 rules. Since we want to migrate all the workstations to Debian (following the party line), lets not futz with this too much.
gautam, 1 Mar 1600: In case I'm being dumb, I attach the screen grab comparing dark offset to the single bounce off PRM, to estimate the RAM contribution. The other signals are there just to show that the ITMs are sufficiently misaligned. The PRCL PDH fringe is usually ~12000 cts in REFL11, ~5000cts in REFL55, and so the RAM offset is <0.1% of the horn-to-horn PDH fringe.
P.S. I know generally PNGs in the elog are frowned upon. But with so many points, the vector PDF export by NDS (i) is several megabytes in size and (ii) excruciatingly slow. I'm proposing a decimation filter for the export function of ndscope - but until then, I claim plotting with "rasterized=True" and saving to PDF and exporting to PNG are equivalent, since both yield a rasterized graphic. |
Attachment 1: RAMestimate.png
|
|
15850
|
Sun Feb 28 22:53:22 2021 |
gautam | Update | LSC | more PRMI checks here: what it is ain't exactly clear |
I looked into this a bit more and crossed off some of the points Rana listed. In order to use REFL 55 as a sensor, I had to fix the frequent saturations seen in the MICH signals, at the nominal (flat) whitening gain of +18 dB. The light level on the REFL55 photodiode (13 mW), its transimpedance (400 ohm), and this +18dB (~ x8) gain, cannot explain signal saturation (0.7A/W * 400 V/A * 8 ~ 2.2kV/W, and the PRCL PDH fringe should be ~1 MW/m, so the PDH fringe across the 4nm linewidth of the PRC should only be a couple of volts). Could be some weird effect of the quad LT1125. Anyway, the fix that has worked in the past, and also this time, is detailed here. Note that the anomalously high noise of the REFL55_Q channel in particular remains a problem. After taking care of that, I did the following:
- PRMI (ETMs misaligned) locking with sidebands resonant in the PRC was restored - REFL55_I was used for PRCL sensing and REFL55_Q was used for MICH sensing. The locks are acquired nearly instantaneously if the alignment is good, and they are pretty robust, see Attachment #1 (the lock losses were IMC related and not really any PRC/MICH problem).
- Measured the loop OLTFs using the usual IN1/IN2 technique. The PRCL loop looks just fine, but the MICH loop UGF is very low apparently. I can't just raise the loop gain because of the feature at ~600 Hz. Not sure what the origin of this is, it isn't present in the analogous TF measurement when the PRMI is locked with carrier resonant (REFL11_I for PRCL sensing, AS55_Q for MICH sensing). I will post the loop breakdown later.
- Re-confirmed that the MICH-->PRCL coupling couldn't be nulled completely in this config either.
- The effect is a geometric one - then 1 unit change in MICH causes a 1/sqrt(2) change in PRCL.
- The actual matrix element that best nulls a MICH drive in the PRCL error point is -0.34 (this has not changed from the PRMI resonant on carrier locking). Why should it be that we can't null this element, if the mechanical transfer functions (see next point) are okay?
- Looked at the mechanical actuator TFs are again (since we forgot to save plots on Friday), by driving the BS and PRM with sine waves (311.1 Hz), one at a time, and looking at the response in REFL55_I and REFL55_Q. Some evidence of some funkiness here already. I can't find any configuration of digital demod phase that gives me a PRCL/MICH sensing ratio of ~100 in REFL55_I, and simultaneously, a MICH/PRCL sensing ratio of ~100 in REFL55_Q. The results are in Attachments #5.
- Drove single frequency lines in MICH and PRCL at 311.1 and 313.35 Hz respectively, for 5 minutes, and made the radar plots in Attachments #2 and #3. Long story short - even in the "nominal" configuration where the sidebands are resonant in the PRC and the carrier is rejected, there is poor separation in sensing.
- Attachments #2 is with the digital REFL55 demod phase set to 35 degrees - I thought this gave the best PRCL sensing in REFL55_I (eyeballed it roughly by looking at ndscope free-swinging PDH fringes).
- But the test detailed in bullet #4, and Attachments #2 itself, suggested that PRCL was actually being sensed almost entirely in the Q phase signal.
- So I changed the digital demod phase to -30 degrees (did a more quantitative estimate with free-swinging PDH fringes on ndscope, horn-to-horn voltages etc).
- The same procedure of sine-wave-driving now yields Attachments #3. Indeed, now PRCL is sensed almost perfectly in REFL55_I, but the MICH signal is also nearly in REFL55_I. How can the lock be so robust if this is really true?
- Attachments #4 shows some relevant time domain signals in the PRMI lock with the sidebands resonant.
- REFL11_I hovers around 0 when REFL55_I is used to sense and lock PRCL - good. The m/ct calibration for REFL11_I and REFL55_I are different so this plot doesn't directly tell us how good the PRCL loop is based on the out-of-loop REFL11_I sensor.
- ASDC is nearly 0, good.
- POP22_I is ~200cts (and POP22_Q is nearly 0) - I didn't see any peak at the drive frequency when driving PRCL with a sine wave, so no linear coupling of PRCL to the f1 sideband buildup, which would suggest there is no PRCL offset.
- Couldn't do the analogous test for AS110 as I removed that photodiode for the AS WFS - it is pretty simple to re-install it, but the ASDC level already doesn't suggest anything crazy here.
Rana also suggested checking if the digital demod phase that senses MICH in REFL55_Q changes from free-swinging Michelson (PRM misaligned), to PRMI aligned - we can quantify any macroscopic length mismatch in the PRC length using this measurement. I couldn't see any MICH signal in REFL55_Q with the PRM misaligned and the Michelson fringing. Could be that +18dB is insufficient whitening gain, but I ran out of time this afternoon, so I'll check later. But not sure if the double attenuation by the PRM makes this impossible. |
Attachment 1: PRMI_SBres_REFL55.png
|
|
Attachment 2: PRMI1f_noArmssensMat.pdf
|
|
Attachment 3: PRMI1f_noArmssensMat.pdf
|
|
Attachment 4: PRMI_locked.png
|
|
Attachment 5: actTFs.pdf
|
|
7671
|
Mon Nov 5 19:38:52 2012 |
jamie, jenne, ayaka, den | Update | Alignment | more alignment woes |
Earlier this morning we thought things were looking pretty good. IPPOS, IPANG, and the AS and REFL spots looked like they hadn't moved too much over the weekend. Our plan was to do a quick check of things, check clearances, etc., tweak up the oplevs, and then close up. This is when I made the ill-fated decisions to check the table levelling.
The BS table was slightly off so I moved one of the thick disk weights off of the other disk weight that it was sitting on, and on to the table next to it. This seemed to improve things enough so I left it there. ITMY didn't need any adjustment, and I move a couple smaller weights around on ITMX. Meanwhile Jenne was adjusting the output PSL power back into it's nominal range (<100mW), and re-tweaking up the mode cleaner.
When we then looked at the vertex situation again it was far off in yaw. This was clearly evident on PZT2, where the beam was no longer centered on the PZT2 mirror and was near the edge. This was causing us to clip at the BS aperture.
We took some deep breaths and tried to figure out what we did that could have messed things up.
Jenne noticed that we had moved slightly on the PSL QPDs, so she adjusted the PSL output pointing to re-aquire the previous pointing, and realigned the MC. This had a very small positive affect, but not nearly enough to compensate for whatever happened.
We spent some more time trying to track down what might have changed, but were unable to come up with anything conclusive. We then decided to see if we could recover things by just adjusting the PZT input steering mirrors. We couldn't; recentering at PRM, BS, ITMY, and ETMY was moving us off of PR3.
Jenne suggested we look at the spot positions on the MMT mirrors. I had checked MMT1 and it looked ok, but we hadn't looked at MMT2. When we checked MMT2 we noticed that we were also off in yaw. This made us consider the possibility that the BS table had twisted, most likely when I was securing the moved mass. Sure enough, when I manually twisted BS table, by grabbing it with my hand, very little force would cause the input beam to walk much of the way across PZT2, more than accounting for the offset. The effect was also very clearly hysteretic as well; I could twist the table a little and it would stay in the new position.
At this point we had fucked things up enough that we realized that we're basically going to have to walk through the whole alignment procedure again, for the third time this vent. We were able to recover the PRM retro-reflection a bit, but the tip-tilts have drifted in pitch (likely again because of the table levelling). So we're going to have to walk through the whole procedure systematically again.
Lessons learned: Many things are MUCH more sensitive than I had been assuming. The tip-tilts are of course ridiculous, in that lightly touching the top or bottom of the mirror mount will move it by quite a lot in pitch. The tables are also much more sensitive than I had realized. In particular, tightening screws can twist the table hystereticly by milliradians, which can of course completely loose the pointing. We need to be a lot more careful.
Assuming the table hasn't moved too much we should be able to recover the alignment by just adjusting the PZTs and tweaking the pitch of the tip-tilts. At least that's the hope. No more touching the table. No more leveling. Hopefully we can get this mostly done tomorrow morning. |
8059
|
Mon Feb 11 17:17:30 2013 |
Jamie | Summary | General | more analysis of half PRC with flipped PR2 |
Quote: |
We need expected finesse and g-factor to compare with mode-scan measurement. Can you give us the g-factor of the half-PRC and what losses did you assumed to calculate the finesse?
|
This is exactly why I added the higher order mode spacing, so you could calculate the g parameter. For TEM order N = n + m with spacing f_N, the overall cavity g parameter should be:
g = (cos( (f_N/f_FSR) * (\pi/N) ))^2
The label on the previous plat should really be f_N/FSR, not \omega_{10,01}
BUT, arbcav does not currently handle arbitrary ABCD matrices for the mirrors, so it's going to be slightly less accurate for our more complex flipped mirrors. The affect would be bigger for a flipped PR3 than for a flipped PR2, because of the larger incidence angle, so arbcav will be a little more correct for our flipped PR2 only case (see below).
Quote: |
Also, flipped PR2 should have RoC of - R_HR * n_sub (minus measured RoC of HR surface multiplied by the substrate refractive index) because of the flipping.
|
This is not correct. Multiplying the RoC by -N would be a very large change. For an arbitrary ABCD matrix:
R_eff = -2 / C
When the incident angle in non-zero:
tangential: R_eff = R_eff / cos(\theta)
sagittal: R_eff = R_eff * cos(\theta)
For flipped PR2, with small 1.5 degree incident angle and RoC of -706 at HR:
M_t = M_s = [1.0000, 0.0131; -0.0028, 1.0000]
R_eff = 705.9
For flipped PR3, with large 41 degree incident angle and RoC of -700 at HR:
M_t = [1.0000, 0; 0.0038, 1.0000]
M_s = [1.0000, 0; 0.0022, 1.0000]
R_eff = 592.4
The affect of the substrate is negligible for flipped PR2 but significant for flipped PR3.
The current half-PRC setup
OK, I have now completely reconciled my alamode and arbcav calculations. I found a small bug in how I was calculating the ABCD matrix for non-flipped TTs that made a small difference. I now get the exact same g parameter values with both with identical input parameters.
Quote: |
According to Jenne dictionary, HR curvature measured from HR side is;
PRM: -122.1 m
PR2: -706 m
PR3: - 700 m
TM in front of BS: -581 m
|
Sooooo, I have redone my alamode and arbcav calculations with these updated values. Here are the resulting g parameters
|
arbcav |
a la mode |
measurement |
g tangential |
0.9754 |
0.9753 |
0.986 +/- 0.001 |
g sagital |
0.9686 |
0.9685 |
0.968 +/- 0.001 |
So the sagittal values all agree pretty well, but the tangential measurement does not. Maybe there is an actual astigmatism in one of the optics, not due to angle of incidence?
arbcav HOM plot:

|
9452
|
Tue Dec 10 10:07:01 2013 |
Steve | Update | IOO | more beam traps |
New razor beam dump installed to trap reflected beam of the input vacuum window.
|
Attachment 1: InputWindowRefDump.jpg
|
|
Attachment 2: InpWindowRefDupm.jpg
|
|