40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 301 of 339  Not logged in ELOG logo
ID Date Authorup Type Category Subject
  14113   Sun Jul 29 20:03:02 2018 ranaUpdatePEMSeismometer temp control

While Shruti is re-building Kira's heater circuit, I looked up how to do one of these (i.e. what does a real EE say about how to build a current source?):

It turns out that there is an Analog Devices application note (AN-968) about this (as there usually is once we get tired of playing around and try to look up the right answer).

I've linked to the note and attached the recommended schematic for high current applications. We'll go ahead as is, but we'll make a PCB according to this App Note for the v3 circuit.

 

Attachment 1: Screen_Shot_2018-07-29_at_8.00.27_PM.png
Screen_Shot_2018-07-29_at_8.00.27_PM.png
  14127   Thu Aug 2 23:09:25 2018 ranaSummaryComputersX Green "Mystery" solved

I'm going to guess that this was me: I was disconnecting some octopus power strip nonsense down there (in particular illuminators and cameras), so I might have turned off the AUX rack by mistake.

Quote:

I walked down to the X end and found that the entire AUX laser electronics rack isn't getting any power. There was no elog about this.

I couldn't find any free points in the power strip where I think all this stuff was plugged in so I'm going to hold off on resurrecting this until tomorrow when I'll work with Steve.

Quote:

The X arm green does not stay locked to the cavity - the alignment looks fine, and the green flashes are strong, but the lock does not hold. This shouldn't be directly connected to anything we did today since the Green PDH servo is entirely analog.

  14130   Fri Aug 3 16:27:40 2018 ranaUpdateSUSLow noise bias path idea

Bah! Too complex.

  14177   Wed Aug 22 12:22:27 2018 ranaSummaryElectronicsInspection of the possible dual backplane interfaces for Acromag DAQ

I think we don't need to keep Crystal Ref: we can change this into a regular Wenzel box with no outside control or monitoring.

Quote:

 

  • Crystal Ref (D980353)
    • Schematic source: LIGO DCC D980353
    • Assesment: Only P1 (1A-4A) is to be connected to Acromag. (Just one DSub is sufficient)
    • P1 1A-4A

 

  14267   Fri Nov 2 12:07:16 2018 ranaUpdateCDSNDScope

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=44971

Let's install Jamie's new Data Viewer

  14290   Mon Nov 12 13:53:20 2018 ranaUpdateIOOloss measurement: oscope vs CDS DAQ

sstop using the ssscope, and just put the ssssignal into the DAQ with sssssome whitening. You'll get 16 bitsśšß.

Quote:

I increased the resolution on the scope by selecting Average (512) mode. I was a bit confused by this, since Yuki was correct that I had only 4 digits recorded over ethernet, which made me think this was an i/o setting. However the sample acquisition setting was the only thing I could find on the tektronix scope or in its manual about improving vertical resolution. This didn't change the saved file, but I found the more extensive programming manual for the scope, which confirms that using average mode does increase the resolution... from 9 to 14 bits! I'm not even getting that many.

 

  14311   Tue Nov 20 17:38:13 2018 ranaUpdateUpgradeNew Coffee Machine

Rana, Aaron, Gautam

The old Zojirushi has died. We have received and comissioned our new Technivoorm Mocha Master today. It is good.

  14329   Sun Dec 2 19:32:35 2018 ranaUpdateIOOfit times

need to vary start/stop times in fit to test for systematics

  14336   Fri Dec 7 19:42:47 2018 ranaFrogselogcan't upgrade DokuWiki because of PHP / SL7

All of our wikis (except the 40m one which unfortunately got turned into ligo.org mess) use DokuWiki. This now has an auto-upgrade feature through the Admin web interface.

I tried this recently and it fails with this message:

DokuWiki 2018-04-22a "Greebo" is available for download.
 You're currently running DokuWiki Release 2017-02-19e "Frusterick Manners".
! New DokuWiki releases need at least PHP 5.6, but you're running 5.4.16. You should upgrade your PHP version before upgrading!

So we'll have to wait until SL7 (which is what NODUS is running).

I DID do a 'yum upgrade' which updated all the packages. I also installed yum-cron so that the RPM listings get updated daily. But sadly, SL7 only has PHP 5.4.16 (which is a June 2013 release):

> Package php-5.4.16-43.el7_4.1.x86_64 already installed and latest version

  14382   Thu Jan 3 21:17:49 2019 ranaConfigurationComputersWorkstation Upgrade: Donatella -> Scientific Linux 7.2

donatella was one of our last workstations running ubuntu12. we installed SL7 on there today

  1. had to use a DVD; wouldn't boot from USB stick
  2. made sure to use userID=1001 and groupID=1001 at the initial install part
  3. went to the Keith Thorne LLO wiki on SL7
  4. The 'yum update' command failed due to a gstreamer conflict. I did "yum remove gstreamer1-plugins-ugly-free-1.10.4-3.el7.x86_64" and then it continued a bit more.
  5. Then there are ~20 errors related to gds-crtools that look like this:Error: Package: gds-crtools-2.18.12-1.el7.x86_64 (lscsoft-production) Requires: libMatrix.so.6.14()(64bit)

  6. I re-ran the yum install .... command using the --skip-broken command and that seemed to complete, although I guess the GDS stuff will not work.
  7. Installed: terminator, inconsolata-fonts, 
  8. Installed XFCE desktop as per K Thorne:  yum groupinstall "Xfce" -y
  9.  
Attachment 1: IMG_20190103_205158.jpg
IMG_20190103_205158.jpg
  14458   Fri Feb 15 18:41:18 2019 ranaUpdateVACVac system is back up

If the acromags lock up whenever there is an electrical spike, shouldn't we have them on UPS to smooth out these ripples? And wasn't the idea to have some handshake/watchdog system to avoid silently dying computers?

Quote:

The problem encountered with the vac controls was indeed resolved via the recommendation I posted yesterday. The Acromags had gone into a protective state (likely caused by an electrical transient in one of the signals)

  14460   Fri Feb 15 19:50:09 2019 ranaUpdateVACVac system is back up

The acromags are on the UPS. I suspect the transient came in on one of the signal lines. Chub tells me he unplugged one of the signal cables from the chassis around the time things died on Monday, although we couldn't reproduce the problem doing that again today.

In this situation it wasn't the software that died, but the acromag units themselves. I have an idea to detect future occurrences using a "blinker" signal. One acromag outputs a periodic signal which is directly sensed by another acromag. The can be implemented as another polling condition enforced by the interlock code.

Quote:

If the acromags lock up whenever there is an electrical spike, shouldn't we have them on UPS to smooth out these ripples? And wasn't the idea to have some handshake/watchdog system to avoid silently dying computers?

Quote:

The problem encountered with the vac controls was indeed resolved via the recommendation I posted yesterday. The Acromags had gone into a protective state (likely caused by an electrical transient in one of the signals)

 

  14464   Mon Feb 18 19:16:55 2019 ranaSummaryComputersnew laptop setup: ASIA

The old IBM laptop (Asia) has died from a fan error after 7 years. WE have a new Lenovo 330 IdeaPad to replace it:

  1. to enter bios, the usual FN keys don't work. Power off laptop. Insert paperclip into small hole on laptop side with upside-down U symbol. Laptop powers up into BIOS setup.
  2. Insert SL 7.6 DVD into drive
  3. Change all settings from modern UEFI into Legacy support. Change Boot order to put CDROM first.
  4. Boot.
  5. Touchpad is not detected. Hookup mouse for setup.
  6. Delete windows partition.
  7. Setup wireless network according to (https://wiki-40m.ligo.caltech.edu/Network). Computer name = asia.martian. 
  8. Set root password. Do not create user (we want to make the controls acct later using the command line so that we can set userID and groupID both to 1001).
  9. Begin install...lots of disk access noises for awhile...

Install done. Touchpad not recognized by linux - lots of forum posts about kernel patching...Arrgh!

  14465   Tue Feb 19 19:03:18 2019 ranaUpdateComputersMartian router -> WPA2

I have swapped our martian router's WiFi security over to WPA2 (AES) from the previous, less-secure, system. Creds are in the secrets-40-red.

  14494   Thu Mar 21 21:50:31 2019 ranaUpdateVACProtection against AC power loss

agreed - we need all pumps on UPS for their safety and also so that we can spin them down safely. Can you and Chub please find a suitable UPS?

Quote:

However, I discovered that TP1---the pump that might be most damaged by a sudden power failure---is not on the UPS. It's plugged directly into a 240V outlet along the wall. This is because the current UPS doesn't have any 240V sockets. I'd recommend we get one that can handle all the turbo pumps.

  14525   Tue Apr 9 00:16:22 2019 ranaUpdateALSEX Green PDH error monitor calibrated

G=10 or G=100?

  14530   Wed Apr 10 16:58:54 2019 ranaUpdateIOOfiber MZ for NPRO freq noise measurements

Can we get some panel mount FC/APC connectors and put them on a box?   Then we could have the whole setup inside of a box that is filled with foam and sits outside the PSL hut. cheeky

  14542   Mon Apr 15 18:13:23 2019 ranaUpdateComputer Scripts / ProgramsAutomated suspension testing with susPython

if this gonna be general for everybody, maybe it oughta be called IFOtest (like the last incarnation that was tried in Livingston) ?

:

In anticipation of needing to test hundreds of suspension signals after the c1susaux upgrade, I've started developing a Python package to automate these tests: susPython

 

then the SUS tests could just be some smaller set of measurements. Using the same code base, but different params.

  14543   Mon Apr 15 18:29:07 2019 ranaSummaryComputersnew laptop setup: ASIA - yum issues

had trouble using YUM to update. This turned out to be a config problem with our Martian router, not the new laptop. Since I've changed the WiFi pwd awhile ago for the martian access for the CDS laptops, you'll have to enter that in order to use the laptops.

turned out to be some Access Control nonsense inside of the router. Even loggin in as admin with a cable gave some of the fields the greyed out color (had to hover over the link and then type the URL directly in the browser window). ASIA is now able to connect and use YUM + usual connections. Gautam and I have also moved the router a little to get easier view of its LED lights and not blockk its WiFi signal with the cable tray. We'll get a little shelf so that we can mount it ~1 foot off of the wall.

still, this seems like a bad laptop choice: the Lenovo Ideapad 330 will not have its touchpad supported by SL7 without compiling a new version of the kernel frown

  14557   Fri Apr 19 15:13:38 2019 ranaUpdateSUSNo consistent solution for output matrix

let us have 3 by 4, nevermore

so that the number of columns is no less

and no more

than the number of rows

so that forevermore we live as 4 by 4 

Quote:

I'm struggling to think

  14559   Fri Apr 19 19:22:15 2019 ranaUpdateSUSActuation matrix still not orthogonal

If thy left hand troubles thee

then let the mirror show the right

for if it troubles enough to cut it off

it would not offend thy sight

  14597   Wed May 8 19:04:20 2019 ranaUpdatePSLPSL turned on again
  1. Increased PSL HEPA Variac from 30 to 100% to get more airflow.
  2. All of the TEC setpoints seem cold to me, so I increased the laser crystal temperature to 30.6 C
  3. Adjusted the diode TEC setpoints individually to optimize the PMC REFL power (unlocked). DTEC A = 22.09 C, DTEC B = 21.04 C
  4. locked PMC at 1900 PT; let's see how long it lasts.

My hunch is that the TECs are working too hard and can't offload the heat onto the heat sinks. As the diode's degrade, more of the electrical power is converted to heat in the diodes rather than 808 nm photons. So hopefully the increased airflow will help.

I tried to increase the DTEC setpoints, but that seems to detune them too far from the laser absorption band, so that's not very efficient for us. IN any case, if we end up changin the laser temperature, we'll have to adjust the ALS lasers to match, and that will be annoying.

 

The office area was very cold and the HVAC air flow stronger than usual. I changed the setpoint on the thermostat near Steve's desk from 71 to 73F at 1830 today.

  14598   Wed May 8 22:11:46 2019 ranaSummaryComputersnew laptop setup: ASIA - yum issues
  • setup controls user using K Thorne LLO CDS offsite workstation instructions
  • modified /etc/fstab ala pianosa to NFS mount disks
  • set up symlinks as other workstations
  • troubles with libsasl2 and libmetaio libraries as usual for SL7 - doing symlink tricks
  • setup shared .bashrc
  • now running 'yum install gds-all' to see if we need more local libraries to run GDS from the shared disks...
  14646   Mon Jun 3 16:40:48 2019 ranaUpdateCamerasTelescope

no BMP files crying

  14668   Thu Jun 13 14:28:46 2019 ranaUpdateCamerasGigE setup

don't need to lock - make sure the 4 OSEMs are centered on the camera field just as we have for the arm cavity mirrors

Quote:

I'm attaching a picture of the screen. I just positioned the enclosure by turning it a bit and I suppose we can see the mirror inside the vacuum now (the MC2 is still not locked). 

 

  14701   Wed Jun 26 18:28:24 2019 ranaUpdateIOOPMC and IMC locked again, some MEDM maintenance

a useful piece of code that we should ask one of this summer's SURFs to write:

  1. read in a BURT .req file which is usually used to make the autosnap / restore.
  2. change ALL of the values to some value (slightly different from its current value)
  3. restore it to its current value

this will solve the sticky slider problem and do it in a systematic way. We can run it from the command line: e.g. 'unsticky.py c1psl c1ioo c1lsc'

Quote:

Aaron complained to me earlier that the PMC could not be locked. Turned out to be a classic sticky slider problem,

  14709   Sun Jun 30 19:47:09 2019 ranaUpdateIOOIMC WFS agenda

we are thinking of doing a sprucing up of the input mode cleaner WFS (sensors + electronics + feedback loops)

  1. WFS Heads
    1. it has been known since ~2002 that the RF circuits in the heads oscillate. 
    2. in the attached PDF you can see that 2 opamps (U3 & U4; MAX4106) are used to amplify the tank circuit made up of the photodiode capacitance and L6.
    3. due to poor PCB layout (the output of U4 runs close to the input of U3) the opamps oscillate if the if the Reed relay (RY2) is left open (not attenuating)
    4. we need to remove/disable the relay
    5. also remove U3 for each quadrant so that it has a fixed gain of (TBD) and a 50 Ohm output
    6. also check that all the resonances are tuned to 1f, 2f, & 3f respectively
  2. Demod boards
  3. DC quadrant readouts
  4. Whitening
  5. Noise budget of sensors, including electronics chain
  6. diagonalization of sensors / actuators
  7. Requirements -
  8. Optical Layout
  9. What does the future hold ?

  1. what is our preferred pin-for-pin replacement for the MAX4106/MAX4107? internet suggests AD9632. Anyone have any experience with it? The Rabbott uses LMH6642 in the aLIGO WFSs. It has a lower slew rate than 9632, but they both have the same distortion of ~ -60 dB for 29.5 MHz.
  2. the whole DC current readout is weird. Should have a load resistor and go into the + input of the opamp, so as to decouple it from the RF stuff. Also why such a fast part? Should have used a OP27 equivalent or LT1124.
  3. LEMO connectors for RF are bad. Wonder if we could remove them and put SMA panel mount on there.
  4. as usual, makes me feel like replacing with better heads...and downstream electronics...
Attachment 1: WFS-Head.pdf
WFS-Head.pdf
  14735   Mon Jul 8 21:42:39 2019 ranaUpdateCamerasGhost image due to beamsplitter

you have to use a BS with a larger wedge angle (5 arcmin ~ 1 mrad) so that the beams don't overlap on the camera

  14793   Sun Jul 21 20:23:35 2019 ranaUpdateIOOMC locked

I found the MC2 face camera disabled(?) and the MC servo board input turned off. I turned the MC locking back on but I don't see any camera image yet.

  14794   Sun Jul 21 22:16:34 2019 ranaUpdateGeneralrossa Xdisp bricked

"bricked" is to mean that it has the functionality of a brick and can be tossed. But rossa seems to have just gotten some software config corruption. I spent a couple hours reinstalling SL7 today as per my previous elog notes and the X display seems to work as before.

i.e. it was fine with the default setup, except for the ole "X chrashes if the mouse goes to left side of screen". As before, I

  1. blacklisted the nouvaeu driver (which is used by default)
  2. download the NVIDIA driver as per the link
  3. run its installation from the no-X terminal

left side of screen is safe again

This time I installed SL7.6 and followed the K Thorne wiki. But its having trouble installing cds-root because it can't find root.frown

 

  14799   Mon Jul 22 21:04:40 2019 ranaUpdateComputersmaking rossa great again
  • copied over /etc/fstab lines from pianosa sothat the NFS mounts work correctly
  • added symlinks so that the NFS dirs mount in the right dirs
  • installed Opera browser
  • symlink libsasl2.so.3 -> libsasl2.so.2 and now DTT runs and can get data now and in the past
  • DTT can natively produce PDF so you don't have to take screen caps of your camera phone and make a chalk drawing of that anymore
  • sitemap/MEDM is working
  • after editing fonts.alias as detailed in Thorne wiki, I ran 'sudo xset fp rehash' to get MEDM to notice new fonts. MEDM Scalable fonts are back!!
  • installed Grace and now dataviewer works
  • ndscope not running: yum install ndscope breaks because it can't find a couple of python34 packagesno
  • tested that AWGGUI also runs and puts in real sine waves
Attachment 1: seis.pdf
seis.pdf
  14818   Tue Jul 30 20:11:12 2019 ranaSummaryIMCIMC ASC: thoughts and hopes

One of the biggest challenges in LIGO is reducing the alignment control noise. If you haven't worked on it for at least a few years, it probably seems like a trivial problem. But all versions of LIGO since 2001 have been limited by ASC noise below ~50 Hz.

I think the 40m IMC is a good testbed for us to try a few approaches towards mitigating this noise in LIGO. The following is a list of steps to take to get there:

  1. Using step responses and TF measurements, characterize the full existing system: SISO loop shapes, cross-couplings, and how diagnonal is the input and output matrices of the WFS. In principle, since we have 2 WFS in reflection and 1 DC QPD in the MC2 transmission, we should have full sensing of all angular DoFs.
  2. Check the correct operation of the WFS heads and the whole RF chain. We want the gains in the system to be such that either the shot noise or the RF electronics noise of the head is the limiting broadband noise in the system.
  3. Balancing the gains and phases of the demodulated signals is tricky, because we have no good reference. Should we use the JenneAM laser or the PSL beam?
  4. Estimate the coupling from the angular feedback signal to the IMC length noise using (1) sine wave injections for linear coupling, and (2) broadband noise for nonlinear coupling.
  5. We think the bilinear noise is due to the beam spot motion modulating the angle to length coupling as sensed by the laser beam. If this is true, we can increase the low frequency gain to minimize the beam spot motion (is this true?).
  6. By sinusoidally driving the mirror angles we can measure the instantaneous beam spot positions. We can then derive the matrix required to convert from our angular sensors (WFS + QPD) into beam spot motion. We should modify our IMC-WFS real-time model to give us DAQ channels which are beam spot estimators.
  7. Build a simulation of an IMC which has WFS, QPD, shot noise, and seismic noise.
  8. Use our optimal linear-feedback design tools to make Angular loops which minimize the bilinear noise coupling.
  9. Build a nonlinear controller (neural networks: dense + CNN) that outperforms the linear one by estimating the beam spot motion continuously and driving the cavity length to cancel the angle-to-length noise. 

I think that steps 1-6 are well within our existing experience, but we should do it anyway so as to reduce the IMC beam motion at low frequencies, and also to reduce the 10-100 Hz frequency noise as seen by the rest of the interferometer.

Steps 7-8 are medium hard, but we can get some help from the CSWG in tackling it.

Step is pretty tough, but I would like to try it and also get some help from MLWG and CSWG to address it.

  14847   Fri Aug 16 04:24:03 2019 ranaUpdateALSALS sensing noise due to IMC

What about just use high gain feedback to MC2 below 20 Hz for the IMC lock? That would reduce the excess if this theory is correct.

  14859   Thu Sep 5 20:30:43 2019 ranaHowToCDSWFS discussion, restarting CDS

via Polish chat, GV tells us to RTFE

  14864   Fri Sep 6 18:08:29 2019 ranaUpdateComputersAlarm noise from smart-ups machine under workstation?

please no one touch the UPS: last time it destroyed ROSSA. Please ask Chub to order the replacement batteries so we can do this in a controlled way (fully shutting down ALL workstations first). Last time we wasted 8 hours on ROSSA rebuilding.

Quote:

There was an alarm sound from the Smart-UPS 2200 sitting under the workstation. I see that the 'replace battery' light is red, and this elog tells me that these batteries are replaced every ~1-4 years; the last replacement was march 2016. Holding down the 'test' button for 2-3 seconds results in the alarm sound and does not clear the replace battery indicator.

  14878   Mon Sep 16 05:08:04 2019 ranaUpdateIOOWFS loop measurements

not need to use DTT. I'm attaching some half-finished notebooks that give the gist.

  1. Download the data with NDS2
  2. Downsample the data for ease of use.
  3. save the data as hdf5 for easy loading later.
  4. demodulate the data at the specified frequencies.

That's it! Now you have the complex, single frequency TFs. Next you invert the matrix.

Attachment 1: LSCsensingMatrix.ipynb
{
 "cells": [
  {
   "cell_type": "markdown",
   "metadata": {},
   "source": [
    "# Get some ASC data - Calculate Sensing Matrix \n",
    "### also make the radar plots"
   ]
  },
... 327 more lines ...
Attachment 2: ASCsensingMatrix.ipynb
{
 "cells": [
  {
   "cell_type": "markdown",
   "metadata": {},
   "source": [
    "# Get some ASC data - Calculate Sensing Matrix \n",
    "### also make the radar plots"
   ]
  },
... 325 more lines ...
  14905   Mon Sep 23 10:49:34 2019 ranaUpdateCDSc1iscaux testing
  • I'd say permanently enable AA and AI. There's no reason to turn these off for usual channels. We can always undo one switch later if we want to use aliasing to sample a high frequency signal (ala SoCal).
  • The PD output should ~20 nV/rHz into the mixer, so that's ~7 nV into the whitening filter. We need 60 dB to be above the ADC noise.
  • I've forgotten what the current config is, but in iLIGO we hacked in a fixed whtiening on the Lt1128 input amp to the WF board so that the lock acquisition could be a little easier (better SNR). On Ch1, that's replacing R60 with a RC network. We want to make sure that the lock acq transients are not saturating the ADC, but can maybe put in a 40:200 stage.
  14925   Wed Oct 2 20:45:18 2019 ranaUpdateComputersrossa revival

Formatted and re-installing OS on rossa for the 3rd or 4th time this year. I suggest that whoever is installing software and adjusting video settings please stop.

If you feel you need to tinker deeply, use ottavia or zita and then be prepared to show up and fix it.

While I was moving the UPS around, the network lights went out for Rossa, so I may have damaged the network interface or cable. Debugging continues.

  14928   Thu Oct 3 11:01:18 2019 ranaUpdateLSC(PR)FPMI locking

wonder if its possible to do variable finesse locking

Gabriele mentioned that Virgo used arm trans PDH for this, but I guess we could possibly use POX/POY to start and bring in the PRM with 50% MICH trans

  14931   Thu Oct 3 14:32:37 2019 ranaUpdateGeneralMake the Jenne-laser setup fiber-coupled

I'm curious to see if we really need the 1611, or if we can calibrate the diode laser vs. the 1611 one time and then just use that calibration to get the absolute cal for the DUT.

  14935   Thu Oct 3 21:50:22 2019 ranaUpdateComputersrossa revival

Got the network to work again just by unplugging the power cord and letting it sit for awhile. But corrupted OS by trying to install Nvidia drivers.

https://www.advancedclustering.com/act_kb/installing-nvidia-drivers-rhel-centos-7/

  14952   Tue Oct 8 16:54:56 2019 ranaUpdateIOOIMC locking not working after this work

I think this offset setting thing is not so good. People do this every few years, but putting offsets in servos means that you cannot maintain a stable alignment when there are changes in the laser power, PMC trans, etc. The better thing is to do the centering of the WFS spots with the unlcoked beam after the control offsets have been offloaded to the suspensions.

  14959   Wed Oct 9 12:15:05 2019 ranaUpdateElectronicsWFS head RF measurements

It would be good if you and Shruti can look at how to change the parameters in Zero so as to do a fit to the measured data. Usually, in scipy.optimize we give it a function with some changeable params, so maybe there's a way to pass params to a zero object in that way. I think Ian and Anchal are doing something similar to their FSS Pockel's cell simulator.

  14986   Wed Oct 23 10:23:26 2019 ranaUpdateALSEX uPDH electronics checkout

During our EX AM/PM setups, I don't think we bumped the PDH gain knob (and I hope that the knob was locked). Possible drift in the PZT response? Good thing Shruti is on the case.

Is there a loop model of green PDH that agrees with the measurement? I'm wondering if something can be done with a compensation network to up the bandwidth or if the phase lag is more like a non-invertible kind.

  14994   Mon Oct 28 18:55:06 2019 ranaUpdateComputersrossa revival

back on new Rossa from Xi computing

  1. switched to using Display Port for video; this works. The DVi, HDMI, VGA ports are connected to the motherboard rather than the video card, so they are not active.
  2. runs super slow w/ SL 7.6; maybe some service is running after startup?
  3. install repos and update according to LLO CDS wiki
  4. add controls user and group according to LLO wiki
  5. remove gstreamer ugly because it breaks yum update
  6. run 'yum update --skip-broken' because GDS doesn't work
  7. turn off old selinux stuff
  8. modify fstab to get NFS

Next:

  1. finish mounting
  2. xfce
  3. figure out why the LLO install instructions can't install any CDS software (e.g. root, DTT, etc)

Update: Sun Nov 3 18:08:48 2019

  1. moved the SL7 fresh install repos back into etc/yum.repos.d/. The LLO instructions has me remove them, but the LLO supplied repos are no good for standard apps. After putting these back was able to install standard apps (terminator, root, diaggui)
  2. copied over /etc/fstab lines from pianosa sothat the NFS mounts work correctly
  3. added symlinks so that the NFS dirs mount in the right dirs
  4. symlink libsasl2.so.3 -> libsasl2.so.2 and now DTT runs and can get data now and in the past
  5. install XFCE
  6. sitemap / MEDM works
  7.  Did "sudo ln -s /usr/lib64/libXm.so.4 /usr/lib64/libXm.so.3" to enable StripTool.

Update: Fri Nov 15 00:00:26 2019:

  1. random hanging of machine while doing various window moving or workspace switching
  2. turned off power management in XFCE
  3. turned off power management on monitor
  4. disabled SELINUX
  5. firewalld was already off
  6. installed most, pdftk, htop, glances, qtgrace, lesstif
  7. dataviewer now works and QTgrace is much nicer than XMGrace
  15023   Wed Nov 13 20:15:56 2019 ranaUpdatePEMFollow-up on seismometer discussion

this is due to the Equivalence Principle: local accelerations are indistinguishable from spacetime curvature. On a spherical Earth, the local gradient of the metric points in the direction towards the center of the Earth, which is colloquially known as "down".

Quote:

I don't understand why the z-axis motion reported by the T240 is ~10x lower at 10 mHz compared to the X and Y motions. Is this some electronics noise artefact?

 

  15025   Thu Nov 14 12:11:04 2019 ranaUpdatePEMFollow-up on seismometer discussion

at 1 Hz' this effect is not large so that's real translation. at lower frequencies a ground tilt couples to the horizontal sensors at first order and so the apparent signal is amplified by the double integral. drawing a free body diagram u can c that

x_apparent = (g / s^2) * theta

but for vortical this not tru because it already measures the full free fall and the tilt only shows up at 2nd order

  15026   Thu Nov 14 23:56:18 2019 ranaUpdateLSCoff the bad Violin filters

We turned off many excessive violin mode bandstop filters in the LSC.

Due to some feedforward work by Jenne or EQ some years ago, we have had ~10 violin notches on in the LSC between the output matrix and the outputs to the SUS.

They were eating phase, computation time, and making ~3 dB gain peaking in places where we can't afford it. I have turned them off and Gautam SDF safed it.

Offensive BS shown in brown and cooler BS shown in blue.

To rotate the DTT landscape plot to not be sideways, use this command (note that the string is 1east, not least):
pdftk in.pdf cat 1east output out.pdf

Attachment 1: out.pdf
out.pdf
  15027   Fri Nov 15 00:18:41 2019 ranaUpdatePEMFollow-up on seismometer discussion

The large ground motion at 1 Hz started up again tonight at around 23:30. I walked around the lab and nearby buildings with a flashlight and couldn't find anything whumping. The noise is very sinusoidal and seems like it must be a 1 Hz motor rather than any natural disturbance or traffic, etc. Suspect that it is a pump in the nearby CES building which is waking up and running to fill up some liquid level. Will check out in the morning.

Estimate of displacement noise based on the observed MC_F channel showing a 25 MHz peak-peak excursion for the laser:

dL = 25e6 * (13 m / (c / lambda)

      = 1 micron

So this is a lot. Probably our pendulum is amplifying the ground motion by 10x, so I suspect a ground noise of ~0.1 micron peak-peak.

(this is a native PDF export using qtgrace rather than XMgrace. uninstall xmgrace and symlink to qtgrace.)

Attachment 1: MCshake.pdf
MCshake.pdf
  15031   Fri Nov 15 18:59:08 2019 ranaUpdateComputersZITA: started upgrade from Ubuntu 14 LTS to 18 LTS

and so it begins...until this is finished I have turned off the projector and moved the striptools to the big TV (time to look for Black Friday deals to replace the projector with a 120 inch LED TV)

ELOG V3.1.3-