ID |
Date |
Author |
Type |
Category |
Subject |
13553
|
Wed Jan 17 14:32:51 2018 |
gautam | Update | DAQ | Acromag checks |
- I take back what I said about the OSEM PD mon at the meeting - there does seem to be to be some overall calibration factor (Attachment #1) that has scaled the OSEM PD readback channels, by a factor of (20000/2^15), which Johannes informs me is some strange feature of the ADC, which he will explain in a subsequent post.
- The coil redback fields on the MEDM screen have a "30Hz HPF" text field below them - I believe this is misleading. Judging by the schematic, we are monitoring, on the backplane (which is what these channels are reading back from), the coil to the voltage with a gain of 0.5. We can reconfirm by checking the ETMX coil driver board, after which we should remove the misleading label on the MEDM screens.
Quote: |
Some suggestions of checks to run, based on the rightmost colum in the wiring diagram here - I guess some of these have been done already, just noting them here so that results can be posted.
- Oplev quadrant slow readouts should match their fast DAQ counterparts.
- Confirm that EX Transmon QPD whitening/gain switching are working as expected, and that quadrant spectra have the correct shape.
- Watchdog tripping under different conditions.
- Coil driver slow readbacks make sense - we should also confirm which of the slow readbacks we are monitoring (there are multiple on the SOS coil driver board) and update the MEDM screen accordingly.
- Confirm that shadow sensor PD whitening is working by looking at spectra.
- Confirm de-whitening switching capability - both to engage and disengage - maybe the procedure here can be repeated.
- Monitor DC alignment of ETMX - we've seen the optic wander around (as judged by the Oplev QPD spot position) while sitting in the control room, would be useful to rule out that this is because of the DC bias voltage stability (it probably isn't).
- Confirm that burt snapshot recording is working as expected - this is not just for c1auxex, but for all channels, since, as Johannes pointed out, the 2018 directory was totally missing and hence no snapshots were being made.
- Confirm that systemd restarts IOC processes when the machine currently called c1auxex2 gets restarted for whatever reason.
|
|
Attachment 1: OSEMPDmon_Acro.png
|
|
13552
|
Tue Jan 16 21:50:53 2018 |
gautam | Update | ALS | Fiber ALS assay | With Johannes' help, I re-installed the box in the LSC electronics rack. In the end, I couldn't find a good solution to thermally insulate the inside of the box with foam - the 2U box is already pretty crowded with ~100m of cabling inside of it. So I just removed all the haphazardly placed foam and closed the box up for now. We can evaluate if thermal stability of the delay line is limiting us anywhere we care about and then think about what to do in this respect. This box is actually rather heavy with ~100m of cabling inside, and is right now mounted just by using the ears on the front - probably should try and implement a more robust mounting solution for the box with some rails for it to sit on.
I then restored all the cabling - but now, the delayed part of the split RF beat signal goes to the "RF in" input of the demod board, and the non-delayed part goes to the back-panel "LO" input. I also re-did the cabling at the PSL table, to connect the two ZHL3-A amplifier inputs to the IR beat PDs in the BeatMouth instead of the green BBPDs.
I didn't measure any power levels today, my plan was to try and get a quick ALS error signal spectrum - but looks like there is too much beat signal power available at the moment, the ADC inputs for both arm beat signals are overflowing often. The flat gain on the AS165 (=ALS X) and POP55 (=ALS Y) channels have been set to 0dB, but still the input signals seem way too large. The signals on the control room spectrum analyzer come from the "RF mon" ports on the demod board, and are marked as -23dBm. I looked at these peak heights with the end green beams locked to the arm cavities, as per the proposed new ALS scheme. Not sure how much cable loss we have from the LSC rack to the network analyzer, but assuming 3dB (which is the Google value for 100ft of RG58), and reading off the peak heights from the control room analyzer, I figure that we have ~0dBm of RF signal in the X arm. => I would expect ~3dBm of signal to the LO input. Both these numbers seem well within range of what the demod board is designed to handle so I'm not sure why we are saturating.
Note that the nominal (differential) I and Q demodulated outputs from the demod board come out of a backplane connector - but we seem to be using the front panel (single-ended) "MON" channels to acquire these signals. I also need to update my Fiber ALS diagram to indicate the power loss in cabling from the PSL table to the LSC electronics rack, expect it to be a couple of dB.
Quote: |
After labeling cables I would disconnect, I pulled the box out of the LSC rack. Attachment #1 is a picture of the insides of the box - looks like it is indeed just two lengths of cabling. There was also some foam haphazardly stuck around inside - presumably an attempt at insulation/isolation.
Since I have the box out, I plan to measure the delay in each path, and also the signal attenuation. I'll also try and neaten the foam padding arrangement - Steve was showing me some foam we have, I'll use that. If anyone has comments on other changes that should be made / additional tests that should be done, please let me know.
20180111_2200: I'm running some TF measurements on the delay line box with the Agilent in the control room area (script running in tmux sesh on pianosa). Results will be uploaded later.
|
|
13551
|
Tue Jan 16 21:46:02 2018 |
gautam | Update | PSL | PSL shelf - AOM power connection interrupted | Johannes informed me that he touched up the PMC REFL camera alignment. I am holding off on re-soldering the AOM driver power as I could use another pair of hands getting the power cable disentangled and removed from the 1X2 rack rails, so that I can bring it out to the lab and solder it back on.
Is anyone aware of a more robust connector solution for the type of power pins we have on the AOM driver?
Quote: |
While moving the RefCav to facilitate the PSL shelf install, I bumped the power cable to the AOM driver. I will re-solder it in the evening after the shelf installation. PMC and IMC have been re-locked. Judging by the PMC refl camera image, I may also have bumped the camera as the REFL spot is now a little shifted. The fact that the IMC re-locked readily suggests that the input pointing can't have changed significantly because of the RefCav move.
|
|
13550
|
Tue Jan 16 16:18:47 2018 |
Steve | Update | PSL | new PSL shelf in place | [ Johannes, Rana, Mark and Steve ]
On the second trial the shelf was installed. Plastic cover removed. South end door put back on and 2W Inno turned on.
Shelf 10 " below the existing one: 92" x 30" x 3/4" melamine (or MDF) covered with white Formica. 200 lbs it's max load. Working distance to top of the table 18"
Quote: |
While moving the RefCav to facilitate the PSL shelf install, I bumped the power cable to the AOM driver. I will re-solder it in the evening after the shelf installation. PMC and IMC have been re-locked. Judging by the PMC refl camera image, I may also have bumped the camera as the REFL spot is now a little shifted. The fact that the IMC re-locked readily suggests that the input pointing can't have changed significantly because of the RefCav move.
|
|
Attachment 1: DSC00020.JPG
|
|
13549
|
Tue Jan 16 11:05:51 2018 |
gautam | Update | PSL | PSL shelf - AOM power connection interrupted | While moving the RefCav to facilitate the PSL shelf install, I bumped the power cable to the AOM driver. I will re-solder it in the evening after the shelf installation. PMC and IMC have been re-locked. Judging by the PMC refl camera image, I may also have bumped the camera as the REFL spot is now a little shifted. The fact that the IMC re-locked readily suggests that the input pointing can't have changed significantly because of the RefCav move.
|
13548
|
Mon Jan 15 17:36:03 2018 |
gautam | HowTo | Optical Levers | Oplev calibration | Summary:
I checked the calibration of the Oplevs for both ITMs, both ETMs and the BS. The table below summarizes the old and new cts->urad conversion factors, as well as the factor describing the scaling applied. Attachment #1 is a zip file of the fits performed to calculate these calibration factors (GPS times of the sweeps are in the titles of these plots). Attachment #2 is the spectra of the various Oplev error signals (open loop, so a measure of seismic induced angular motion for a given optic, and DoF) after the correction. Loop TF measurements post calibration factor update and loop gain adjustment to be uploaded tomorrow.
Optic, DoF |
Old calib [urad/ct] |
New Calib [urad/ct] |
Correction Factor [new/old] |
ETMX, Pitch |
200 |
175 |
0.88 |
ETMX, Yaw |
222 |
175 |
0.79 |
ITMX, Pitch |
122 |
134 |
1.1 |
ITMX, Yaw |
147 |
146 |
1 |
BS, Pitch |
130 |
136 |
1.05 |
BS, Yaw |
170 |
176 |
1.04 |
ITMY, Pitch |
239 |
254 |
1.06 |
ITMY, Yaw |
226 |
220 |
0.97 |
ETMY, Pitch |
140 |
164 |
1.17 |
ETMY, Yaw |
143 |
169 |
1.18 |
Motivation:
We'd like for the Oplev calibration to be a reliable readback of the optic alignment. For example, a calibrated Oplev would be a useful diagnostic to analyze the drifting (?) ETMX.
Details:
- I locked and dither aligned the individual arms.
- I then used a 60 second ramp time to misalign <optic> in {ITMX, ITMY, BS, ETMX, ETMY} one at a time, and looked at the appropriate arm cavity transmission while the misalignment was applied. The amplitude of the misalignment was chosen such that in the maximally misaligned state, the arm cavity was still locked to a TEM00 mode, with arm transmission ~40% of the value when the cavity transmission was maximized using the dither alignment servos. The CDS ramp is not exactly linear, it looks more like a sigmoid near the start and end, but I don't think that really matters for these fits.
- I used the script OLcalibFactor.py (located at /opt/rtcds/caltech/c1/scripts/OL) to fit the data and extract calibration factors. This script downloads the arm cavity transmission and the OL error signal during the misalignment period, and fits a Gaussian profile to the data (X=oplev error signal, Y=arm transmission). Using geometry and mode overlap considerations, we can back out the misalignment in physical units (urad).
Comments:
- For the most part, the correction was small, of the order of a few percent. The largest corrections were for the ETMs. I believe the last person to do Oplev calibration for the TMs was Yutaro in Dec 2015, and since then, we have certainly changed the HeNes at the X and Y ends (but not for the ITMs), so this seems consistent.
- From attachment #2, most of the 1Hz resonances line up quite well (around 1-3urad/rtHz), so gives me some confidence in this calibration.
- I haven't done a careful error analysis yet - but the fits are good to the eye, and the residuals look randomly distributed for the most part. I've assumed precision to the level of 1 urad/ct in setting the new calibration factors.
- I think the misalignment period of 60 seconds is sufficiently long that the disturbance applied to the Oplev loop is well below the lower loop UGF of ~0.2Hz, and so the in loop Oplev error signal is a good proxy for the angular (mis)alignment of the optic. So no loop correction factor was applied.
- I've not yet calibrated the PRM and SRM oplevs.
Now that the ETMX calibration has been updated, let's keep an eye out for a wandering ETMX. |
Attachment 1: OLcalib_20180115.tar.bz2
|
Attachment 2: Oplevs.pdf
|
|
13547
|
Mon Jan 15 11:53:57 2018 |
gautam | Update | IOO | MCautolocker getting stuck | Looks like this problem presisted over the weekend - Attachment #1 is the wall StripTool trace for PSL diagnostics, seems like the control signal to the NPRO PZT and FSS EOM were all over the place, and saturated for the most part.
I traced down the problem to an unresponsive c1iool0. So looks like for the IMC autolocker to work properly (on the software end), we need c1psl, c1iool0 and megatron to all be running smoothly. c1psl controls the FSS box gains through EPICS channels, c1iool0 controls the MC servo board gains through EPICS channels, and megatron runs the various scripts to setup the gains for either lock acquisition or in lock states. In this specific case, the autolocker was being foiled because the mcdown script wasn't running properly - it was unable to set the EPICS channel C1:IOO-MC_VCO_GAIN to its lock acquisition value of -15dB, and was stuck at its in-lock value of +7dB. Curiously, the other EPICS channels on c1iool0 seemed readable and were reset by mcdown. Anyways, keying the c1iool0 crate seems to have fixed the probelm.
Quote: |
I've noticed this a couple of times today - when the autolocker runs the mcdown script, sometimes it doesn't seem to actually change the various gain sliders on the PSL FSS. There is no handshaking built in to the autolocker at the moment. So the autolocker thinks that the settings are correct for lock re-acquisition, but they are not. The PCdrive signal is often railing, as is the PZT signal. The autolocker just gets stuck waiting to re-acquire lock. This has happened today ~3 times, and each time, the Autolocker has tried to re-acquire lock unsuccessfully for ~1hour.
Perhaps I'll add a line or two to check that the signal levels are indicative of mcdown being successfully executed.
|
|
Attachment 1: MCautolkockerStuck.png
|
|
13546
|
Sat Jan 13 03:20:55 2018 |
Koji | Configuration | Computers | sendmail troubles on nodus | I know it, and I don't like it. DokuWiki seems to allow us to use an external server for notification emails. That would be the way to go. |
13545
|
Sat Jan 13 02:36:51 2018 |
rana | Configuration | Computers | sendmail troubles on nodus | I think sendmail is required on nodus since that's how the dokuwiki works. That's why the dokuwiki was trying to send an email to Umakant. |
13544
|
Fri Jan 12 20:35:34 2018 |
Udit Khandelwal | Summary | General | 2018/01/12 Summary |
- 40m Lab CAD
- Worked further on positioning vacuum tubes and chambers in the building.
- Next step would be to find some drawings for optical table positions and vibration isolation stack. Need help with this!
- Tip Tilt Suspension (D070172)
- Increased the length of side arms. The overall height of D070172 assembly matches that of D960001.
- The files are present in dropbox in [40mShare] > [40m_cad_models] > [TT - Tip Tilt Suspension]
|
13543
|
Fri Jan 12 19:15:34 2018 |
johannes | Update | DAQ | etmx slow daq chassis | Steve and I removed c1auxex from 1X9 today to make space for the DAQ chassis. Steve installed rails for mounting. To install the box I had to remove all cabling, for which I used the usual precautions (disconnect satellite box etc.)
On reconnect c1auxex2 didn't initialize the physical EPICS channels (the 'actual' acromag channels), apparently it had trouble communicating. A reboot fixed this. It's possible that this is because of the direct cable connection without a network switch that exists
between the Acromags and c1auxex. The EPICS server was started automatically on reboot.
Currently the channel defaults need to be loaded manually after every EPICS server script restart with burt. I'm looking for a good way to automate this, but the only compiled burt binaries for x86 (that we can in principle run on c1auxex2 itself) on the martian network are from EPICS version 3.14.10 and throw a missing shared object error. Could be that simply some path variable is missing.
The burt binaries are not distributed by the lscsoft or cdssoft packages, so alternatively we would need to compile it ourselves for x86 or get it working with the older epics version. |
13542
|
Fri Jan 12 18:22:09 2018 |
gautam | Configuration | Computers | sendmail troubles on nodus | Okay I will port awade's python mailer stuff for this purpose.
gautam 14Jan2018 1730: Python mailer has been implemented: see here for the files. On shared drive, the files are at /opt/rtcds/caltech/c1/scripts/general/pizza/pythonMailer/
gautam 11Feb2018 1730: The python mailer had never once worked successfully in automatically sending the message. I realized this may be because I had put the script on the root user's crontab, but had setup the authentication keyring with the password for the mailer on the controls user. So I have now setup a controls user crontab, which for now just runs the pizza mailing. let's see if this works next Sunday...
Quote: |
I personally don't like the idea of having sendmail (or something similar like postfix) on a personal server as it requires a lot of maintenance cost (like security update, configuration, etc). If we can use external mail service (like gmail) via gmail API on python, that would easy our worry, I thought.
|
|
13541
|
Fri Jan 12 18:08:55 2018 |
gautam | Update | General | pip installed on nodus | After much googling, I figured out how to install pip on SL7:
sudo easy_install pip
Next, I installed git:
sudo yum install git A
Turns out, actually, pip can be installed via yum using
sudo yum install python-pip
|
13540
|
Fri Jan 12 16:01:27 2018 |
Koji | Configuration | Computers | sendmail troubles on nodus | I personally don't like the idea of having sendmail (or something similar like postfix) on a personal server as it requires a lot of maintenance cost (like security update, configuration, etc). If we can use external mail service (like gmail) via gmail API on python, that would easy our worry, I thought. |
13539
|
Fri Jan 12 12:31:04 2018 |
gautam | Configuration | Computers | sendmail troubles on nodus | I'm having trouble getting the sendmail service going on nodus since the Christmas day power failure - for some reason, it seems like the mail server that sendmail uses to send out emails on nodus (mx1.caltech.iphmx.com, IP=68.232.148.132) is on a blacklist! Not sure how exactly to go about remedying this.
Running sudo systemctl status sendmail.service -l also shows a bunch of suspicious lines:
Jan 12 10:15:27 nodus.ligo.caltech.edu sendmail[6958]: STARTTLS=client, relay=cluster6a.us.messagelabs.com., version=TLSv1/SSLv3, verify=FAIL, cipher=DHE-RSA-AES256-GCM-SHA384, bits=256/256
Jan 12 10:15:45 nodus.ligo.caltech.edu sendmail[6958]: w0A7QThE032091: to=<umakant.rapol@iiserpune.ac.in>, ctladdr=<controls@nodus.ligo.caltech.edu> (1001/1001), delay=2+10:49:16, xdelay=00:00:39, mailer=esmtp, pri=5432408, relay=cluster6a.us.messagelabs.com. [216.82.251.230], dsn=4.0.0, stat=Deferred: 421 Service Temporarily Unavailable
Jan 12 11:15:23 nodus.ligo.caltech.edu sendmail[10334]: STARTTLS=client, relay=cluster6a.us.messagelabs.com., version=TLSv1/SSLv3, verify=FAIL, cipher=DHE-RSA-AES256-GCM-SHA384, bits=256/256
Jan 12 11:15:31 nodus.ligo.caltech.edu sendmail[10334]: w0A7QThE032091: to=<umakant.rapol@iiserpune.ac.in>, ctladdr=<controls@nodus.ligo.caltech.edu> (1001/1001), delay=2+11:49:02, xdelay=00:00:27, mailer=esmtp, pri=5522408, relay=cluster6a.us.messagelabs.com. [216.82.251.230], dsn=4.0.0, stat=Deferred: 421 Service Temporarily Unavailable
Jan 12 12:15:25 nodus.ligo.caltech.edu sendmail[13747]: STARTTLS=client, relay=cluster6a.us.messagelabs.com., version=TLSv1/SSLv3, verify=FAIL, cipher=DHE-RSA-AES256-GCM-SHA384, bits=256/256
Jan 12 12:15:42 nodus.ligo.caltech.edu sendmail[13747]: w0A7QThE032091: to=<umakant.rapol@iiserpune.ac.in>, ctladdr=<controls@nodus.ligo.caltech.edu> (1001/1001), delay=2+12:49:13, xdelay=00:00:33, mailer=esmtp, pri=5612408, relay=cluster6a.us.messagelabs.com. [216.82.251.230], dsn=4.0.0, stat=Deferred: 421 Service Temporarily Unavailable
Why is nodus attempting to email umakant.rapol@iiserpune.ac.in? |
13538
|
Fri Jan 12 10:26:24 2018 |
Steve | Update | PSL | PSL shelf work schedule | Measurements for good fit were made. The new shelf will be installed on next Tuesday at 2pm
The reference cavity ion pump is in the way so the cavity will be moved 5" westward. The shelf height space will be 10" Under shelf working height 18" to optical table.
Quote: |
I have just received the scheduling of the PSL self work for tomorrow. Gautam and I agreed that if it is needed I will shut the laser off and cover the hole table with plastic.
|
|
13537
|
Fri Jan 12 10:02:05 2018 |
johannes | Update | DAQ | etmx slow daq chassis |
Quote: |
There is some problem with the routing of the fast BIO channels through the new chassis - so the ANALOG de-whitening filter seems to be always engaged, despite our toggling the software BIO bits . Something must be wrongly wired, as we confirmed by returning only the FAST BIO wiring to the pre-acromag state (but everything else is now controlled by acromag) and didn't have the problem anymore. Or some electrical connection is not made (I had to use gender changers on these connectors due to lack of proper cabling)
The switches for the QPD gain stages did not work. I suspect a wiring problem, since the switching of the coil enables did work.
|
Both issues were fixed. In both cases it was two separate causes that prevented them from working.
The QPD gain stage switch software channels were assigned to wrong physical pins of the Acromag, and additionally their DSub cable was swapped with a different one.
The BIO switching had its signal and ground wires swapped on ALL connections, and part of it was also suffering from the cable-mixup.
Both issues were fixed. All backplane signals are now routed through the Acromag chassis.
Gautam and I did notice that occasionally ETMX alignment will start drifting as evident from the OpLev. I want to set up a diagnostic channel to see if the DAC voltages coming from the Acromag are responsible for this. |
13536
|
Thu Jan 11 21:09:33 2018 |
gautam | Update | CDS | revisiting Acromag | We'd like to setup the recording of the PSL diagnostic connector Acromag channels in a more robust way - the objective is to assess the long term performance of the Acromag DAQ system, glitch rates etc. At the Wednesday meeting, Rana suggested using c1ioo to run the IOC processes - the advantage being that c1ioo has the systemd utility, which seems to be pretty reliable in starting up various processes in the event of the computer being rebooted for whatever reason. Jamie pointed out that this may not be the best approach however - because all the FEs get the list of services to run from their common shared drive mount point, it may be that in the event of a power failure for example, all of them try and start the IOC processes, which is presumably undesirable. Furthermore, Johannes reported the necessity for the procServ utility to be able to run the modbusIOC process in the background - this utility is not available on any of the FEs currently, and I didn't want to futz around with trying to install it.
One alternative is to connect the PSL Acromag also to the Supermicro computer Johannes has set up at the Xend - it currently has systemd setup to run the modbusIOC, so it has all the utilities necessary. Or else, we could use optimus, which has systemd, and all the EPICS dependencies required. I feel less wary of trying to install procServ on optimus too. Thoughts?
|
13535
|
Thu Jan 11 20:59:41 2018 |
gautam | Update | DAQ | etmx slow daq chassis | Some suggestions of checks to run, based on the rightmost colum in the wiring diagram here - I guess some of these have been done already, just noting them here so that results can be posted.
- Oplev quadrant slow readouts should match their fast DAQ counterparts.
- Confirm that EX Transmon QPD whitening/gain switching are working as expected, and that quadrant spectra have the correct shape.
- Watchdog tripping under different conditions.
- Coil driver slow readbacks make sense - we should also confirm which of the slow readbacks we are monitoring (there are multiple on the SOS coil driver board) and update the MEDM screen accordingly.
- Confirm that shadow sensor PD whitening is working by looking at spectra.
- Confirm de-whitening switching capability - both to engage and disengage - maybe the procedure here can be repeated.
- Monitor DC alignment of ETMX - we've seen the optic wander around (as judged by the Oplev QPD spot position) while sitting in the control room, would be useful to rule out that this is because of the DC bias voltage stability (it probably isn't).
- Confirm that burt snapshot recording is working as expected - this is not just for c1auxex, but for all channels, since, as Johannes pointed out, the 2018 directory was totally missing and hence no snapshots were being made.
- Confirm that systemd restarts IOC processes when the machine currently called c1auxex2 gets restarted for whatever reason.
|
13534
|
Thu Jan 11 20:51:20 2018 |
gautam | Update | ALS | Fiber ALS assay | After labeling cables I would disconnect, I pulled the box out of the LSC rack. Attachment #1 is a picture of the insides of the box - looks like it is indeed just two lengths of cabling. There was also some foam haphazardly stuck around inside - presumably an attempt at insulation/isolation.
Since I have the box out, I plan to measure the delay in each path, and also the signal attenuation. I'll also try and neaten the foam padding arrangement - Steve was showing me some foam we have, I'll use that. If anyone has comments on other changes that should be made / additional tests that should be done, please let me know.
20180111_2200: I'm running some TF measurements on the delay line box with the Agilent in the control room area (script running in tmux sesh on pianosa). Results will be uploaded later.
Quote: |
For completeness, I'd like to temporarily pull the box out of the rack, open it up, take photos, and make a diagram unless there are any objections.
|
|
Attachment 1: IMG_5112.JPG
|
|
13533
|
Thu Jan 11 18:50:31 2018 |
gautam | Update | IOO | MCautolocker getting stuck | I've noticed this a couple of times today - when the autolocker runs the mcdown script, sometimes it doesn't seem to actually change the various gain sliders on the PSL FSS. There is no handshaking built in to the autolocker at the moment. So the autolocker thinks that the settings are correct for lock re-acquisition, but they are not. The PCdrive signal is often railing, as is the PZT signal. The autolocker just gets stuck waiting to re-acquire lock. This has happened today ~3 times, and each time, the Autolocker has tried to re-acquire lock unsuccessfully for ~1hour.
Perhaps I'll add a line or two to check that the signal levels are indicative of mcdown being successfully executed. |
13532
|
Thu Jan 11 14:47:11 2018 |
Steve | Update | PSL | shelf work for tomorrow | I have just received the scheduling of the PSL self work for tomorrow. Gautam and I agreed that if it is needed I will shut the laser off and cover the hole table with plastic. |
13531
|
Thu Jan 11 14:22:40 2018 |
gautam | Update | ALS | Fiber ALS assay | I did a cursory check of the ALS signal chain in preparation for commissioning the IR ALS system. The main elements of this system are shown in my diagram in the previous elog in this thread.
Questions I have:
- Does anyone know what exactly is inside the "Delay Line" box? I can't find a diagram anywhere.
- Jessica's SURF report would suggest that there are just 2 50m cables in there.
- There are two power splitters taped to the top of this box.
- It is unclear to me if there are any active components in the box.
- It is unclear to me if there is any thermal/acoustic insulation in there.
- For completeness, I'd like to temporarily pull the box out of the LSC rack, open it up, take photos, and make a diagram unless there are any objections.
- If you believe the front panel labeling, then currently, the "LO" input of the mixer is being driven by the part of the ALS beat signal that goes through the delay line. The direct (i.e. non delayed) output of the power splitter goes to the "RF" input of the mixer. The mixer used, according to the DCC diagram, is a PE4140. Datasheet suggests the LO power can range from -7dBm to +20dBm. For a -8dBm beat from the IR beat PDs, with +24dB gain from the ZHL3A but -3dB from the power splitter, and assuming 9dB loss in the cable (I don't know what the actual loss is, but according to a Frank Seifert elog, the optimal loss is 8.7dB and I assume our delay line is close to optimal), this means that we have ~4dBm at the "LO" input of the demod board. The schematic says the nominal level the circuit expects is 10dBm. If we use the non-delayed output of the power splitter, we would have, for a -8dBm beat, (-8+24-3)dBm ~13dBm, plus probably some cabling loss along the way which would be closer to 10dBm. So should we use the non-delayed version for the LO signal? Is there any reason why the current wiring is done in this way?
|
13530
|
Thu Jan 11 09:57:17 2018 |
Steve | Update | DAQ | acromag at ETMX | Good going Johannes!
|
Attachment 1: Acromg_in_action.png
|
|
13529
|
Wed Jan 10 22:24:28 2018 |
johannes | Update | DAQ | etmx slow daq chassis | This evening I transitioned the slow controls to c1auxex2.
- Disconnected satellite box
- Turned off c1auxex
- Disconnected DIN cables from backplace connectors
- Attached purple adapter boards
- Labeled DSub cables for use
- Connected DSub cables to adapter boards and chassis
- Initiated modbus IOC on c1auxex2
Gautam and I then proceeded to test basic functionality
- Pitch bias sliders move pitch, yaw moves yaw
.
- Coil enable and monitoring channels work

- Watchdog seems to work.
We set the treshold for tripping low, excited the optic, watchdog didn't disappoint and triggered.
- All channels Initialize with "0" upon machine/server script restart. This means the watchdog happens to be OFF, which is good
. It would be great if we could also initialize PIT and YAW to retain their value from before to avoid kicking the optic. This is not straightforward with EPICS records but there must be a way.
- We got the local damping going
.
- There is some problem with the routing of the fast BIO channels through the new chassis - so the ANALOG de-whitening filter seems to be always engaged, despite our toggling the software BIO bits
. Something must be wrongly wired, as we confirmed by returning only the FAST BIO wiring to the pre-acromag state (but everything else is now controlled by acromag) and didn't have the problem anymore. Or some electrical connection is not made (I had to use gender changers on these connectors due to lack of proper cabling)
- The switches for the QPD gain stages did not work.
I suspect a wiring problem, since the switching of the coil enables did work.
Arms are locked, have been for ~1hour with no hickups. We will leave it like this overnight to observe, and debug further tomorrow. |
13528
|
Wed Jan 10 22:19:44 2018 |
rana | Update | SUS | ETMX DC alignment | Best to just calibrate the ETM OL in the usual way. I bet the OSEM outputs have a cal uncertainty of ~50% since the input matrix changes as a function of the DC alignment. Still, a 30 urad pitch mis-alignment gives a (30e-6 rad)(40 m) ~ 1 mm beam spot shift. This would be enough to flash other modes, but it would still be easy to lock on a TEM00 like this. I also doubt that the OL calibration is valid outside of some region near zero - can easily check by moving the ETM bias sliders.
Quote: |
I should've put in the SUSPIT and SUSYAW channels in the previous screenshot. I re-aligned ETMX till I could see IR flashes in the arm, and also was able to lock the green beam on a TEM00 mode with reasonable transmission. As I suspected, this brought the Oplev spot back near the center of it's QPD. But the answer to the question "How much did I move the ETM by" still varies by ~1 order of magnitude, depending on if you believe the OSEM SUSPIT and SUSYAW signals, or the Oplev error signals - I don't know which, if any, of these, are calibrated.
|
What we still don't know is if this is due to Johannes/Aaron working at the ETMX rack (bumping some of the flaky coil cables and/or bumping the blue beams which support the stack). Adding or substracting weight from the stack supports will give us an ETM mis alignment. |
13527
|
Wed Jan 10 18:53:31 2018 |
gautam | Update | SUS | ETMX DC alignment | I should've put in the SUSPIT and SUSYAW channels in the previous screenshot. I re-aligned ETMX till I could see IR flashes in the arm, and also was able to lock the green beam on a TEM00 mode with reasonable transmission. As I suspected, this brought the Oplev spot back near the center of it's QPD. But the answer to the question "How much did I move the ETM by" still varies by ~1 order of magnitude, depending on if you believe the OSEM SUSPIT and SUSYAW signals, or the Oplev error signals - I don't know which, if any, of these, are calibrated. |
Attachment 1: ETMXdrift.png
|
|
13526
|
Wed Jan 10 16:27:02 2018 |
Steve | Configuration | SEI | load cell for weight measurement | We could use similar load cells to make the actual weight measurement on the Stacis legs. This seems practical in our case.
I have had bad experience with pneumatic Barry isolators.
Our approximate max compression loads are 1500 lbs on 2 feet and 2500 lbs on the 3rd one.
Quote: |
We've been thinking about putting in a blade spring / wire based aluminum breadboard on top of the ETM & ITM stacks to get an extra factor of 10 in seismic attenuation.
Today Koji and I wondered about whether we could instead put something on the outside of the chambers. We have frozen the STACIS system because it produces a lot of excess noise below 1 Hz while isolating in the 5-50 Hz band.
But there is a small gap between the STACIS and the blue crossbeams that attache to the beams that go into the vacuum to support the stack. One possibility is to put in a small compliant piece in there to gives us some isolation in the 10-30 Hz band where we are using up a lot of the control range. The SLM series mounts from Barry Controls seems to do the trick. Depending on the load, we can get a 3-4 Hz resonant frequency.
Steve, can you please figure out how to measure what the vertical load is on each of the STACIS?
|
|
Attachment 1: stacis3LoadCells.png
|
|
13525
|
Wed Jan 10 15:25:43 2018 |
johannes | Configuration | Computer Scripts / Programs | autoburt making backups again |
Quote: |
I manually created the /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2018/ directory. Maybe this fixes the hickup? Gotta wait about 30 minutes.
|
It worked. The first backup of the year is now from Wednesday, 01/10/18 at 15:19. Ten days of automatic backups are missing. Up until 2204 the year folders had been pre-emptively created so why was 2018 missing?
gautam: this is a bit suspect still - the snapshot file for c1auxex at least seemed to be too light on channels recorded. this was before any c1auxex switching. to be investigated. |
13524
|
Wed Jan 10 14:17:57 2018 |
johannes | Configuration | Computer Scripts / Programs | autoburt no longer making backups | I was looking into setting up autoburt for the new c1auxex2 and found that it stopped making automatic backups for all machines after the beginning of the new year. There is no 2018 folder (it was the only one missing) in /opt/rtcds/caltech/c1/burt/autoburt/snapshots and the /latest/ link in /opt/rtcds/caltech/c1/burt/autoburt/ leads to the last backup of 2017 on 12/31/17 at 23:19.
The autoburt log file shows that the back script last ran today 01/10/18 at 14:19, as it should have, but doesn't show any errors and ends with "You are at the 40m".
I'm not familiar with the autoburt scheduling using cronjobs. If I'm not mistaken the relevant cronjob file is /cvs/cds/rtcds/caltech/c1/scripts/autoburt/autoburt.cron which executes /cvs/cds/rtcds/caltech/c1/scripts/autoburt/autoburt.pl
I've never used perl but there's the following statement when establishing the directory for the new backup:
$yearpath = $autoburtpath."/snapshots/".$thisyear;
# print "scanning for path $yearpath\n";
if (!-e $yearpath) {
die "ERROR: Year directory $yearpath does not exist\n";
}
I manually created the /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2018/ directory. Maybe this fixes the hickup? Gotta wait about 30 minutes. |
13523
|
Wed Jan 10 12:42:27 2018 |
gautam | Update | SUS | ETMX DC alignment | I've been observing this for a few days: ETMX's DC alignment seems to drift by so much that the previously well aligned X arm cavity is now totally misaligned.
The wall StripTool trace shows that both the X and Y arms were locked with arm transmissions around 1 till c1psl conked out - so in the attached plot, around 1400 UTC, the arm cavity was well aligned. So the sudden jump in the OSEM sensor signals is the time at which LSC control to the ETM was triggered OFF. But as seen in the attached plot, after the lockloss, the Oplev signals seem to show that the mirror alignment drifted by >50urad. This level of drift isn't consistent with the OSEM sensor signals - of course, the Oplev calibration could be off, but the tension in values is almost an order of magnitude. The misalignment seems real - the other Oplev spots have stuck around near the (0,0) points where I recentered them last night, only ETMX seems to have undergone misalignment.
Need to think about what's happening here. Note that this kind of "drift" behaviour seems to be distinct from the infamous ETMX "glitching" problem that was supposed to have been fixed in the 2016 vent.
|
Attachment 1: ETMXdrift.png
|
|
13522
|
Wed Jan 10 12:24:52 2018 |
gautam | Update | CDS | slow machine bootfest | MC autolocker got stuck (judging by wall StripTool traces, it has been this way for ~7 hours) because c1psl was unresponsive so I power cycled it. Now MC is locked. |
13521
|
Wed Jan 10 09:49:28 2018 |
Steve | Update | PEM | the rat is back | Five mechcanical traps set inside of boxes. Red-white warning tape on top of each.
Quote: |
Last jump at rack Y2.
|
|
13520
|
Tue Jan 9 21:57:29 2018 |
gautam | Update | Optimal Control | Oplev loop tuning | After some more tweaking, I feel like I may be getting closer to a cost-function definition that works.
- The main change I made was to effectively separate the BR-bandstop filter poles/zeros and the rest of the poles and zeros.
- So now the input vector is still a list of highest pole frequency followed by frequency separations, but I can specify much tighter frequency bounds for the roots of the part of the transfer function corresponding to the Bounce/Roll bandstops.
- This in turn considerably reduces the swarming area - at the moment, half of the roots are for the notches, and in the (f0,Q) basis, I see no reason for the bounds on f0 to be wider than [10,30]Hz.
Some things to figure out:
- How the "force" the loop to be AC coupled without explicitly requiring it to be so? What should the AC coupling frequency be? From the (admittedly cursory) sensing noise measurement, it would seem that the Oplev error signal is above sensing noise even at frequencies as low as 10mHz.
- In general, the loops seem to do well in reducing sensing noise injection - but they seem to do this at the expense of the loop gain at ~1Hz, which is not what we want.
- I am going to try and run the optimizer with an excess of poles relative to zeros
- Currently, n(Poles) = n(Zeros), and this is the condition required for elliptic low pass filters, which achieve fast transition between the passband and stopband - but we could just as well use a less rapid, but more monotonic roll-off. So the gain at 50Hz might be higher, but at 200Hz, we could perhaps do better with this approach.
- The loop shape between 10 and 30Hz that the optimizer outputs seems a but weird to me - it doesn't really quite converge to a bandstop. Need to figure that out.
|
Attachment 1: loopOpt_180108_2232.pdf
|
|
13519
|
Tue Jan 9 21:38:00 2018 |
gautam | Update | ALS | ALS recovery |
- Aligned IFO to IR.
- Ran dither alignment to maximize arm transmission.
- Centered Oplev reflections onto their respective QPDs for ITMs, ETMs and BS, as DC alignment reference. Also updated all the DC alignment save/restore files with current alignment.
- Undid the first 5 bullets of elog13325. The AUX laser power monitor PD remains to be re-installed and re-integrated with the DAQ.
- I stupidly did not refer to my previous elog of the changes made to the X end table, and so spent ages trying to convince Johannes that the X end green alignment had shifted, and turned out that the green locking wasn't going because of the 50ohm terminator added to the X end NPRO PZT input. I am sorry for the hours wasted

- GTRY and GTRX at levels I am used to seeing (i.e. ~0.25 and ~0.5) now. I tweaked input pointing of green and also movable MM lenses at both ends to try and maximize this.
- Input green power into X arm after re-adjusting previously rotated HWP to ~100 degrees on the dial is ~2.2mW. Seems consistent with what I reported here.
- Adjusted both GTR cameras on the PSL table to have the spots roughly centered on the monitors.
Will update shortly with measured OLTFs for both end PDH loops.
- X end PDH seems to have UGF ~9kHz, Y end has ~4.5kHz. Phase margin ~60 degrees in both cases. Data + plotting code attached. During the measurement, GTRY ~0.22, GTRX~0.45.
Next, I will work on commissioning the BEAT MOUTH for ALS beat generation.
Note: In the ~40mins that I've been typing out these elogs, the IR lock has been stable for both the X and Y arms. But the X green has dropped lock twice, and the Y green has been fluctuating rather more, but has mangaged to stay locked. I think the low frequency Y-arm GTRY fluctuations are correlated with the arm cavity alignment drifting around. But the frequent X arm green lock dropouts - not sure what's up with that. Need to look at IR arm control signals and ALS signals at lock drop times to see if there is some info there. |
Attachment 1: GreenLockStability.png
|
|
Attachment 2: ALS_OLTFs_20180109.pdf
|
|
Attachment 3: ALS_OLTF_data_20180109.tar.bz2
|
13518
|
Tue Jan 9 11:52:29 2018 |
gautam | Update | CDS | slow machine bootfest | Eurocrate key turning reboots today morning for and c1susaux, c1auxey and c1iscaux. These were responding to ping but not telnet-able. Usual precautions were taken to minimize risk of ITMX getting stuck.
|
13517
|
Tue Jan 9 00:07:03 2018 |
johannes | Update | DAQ | etmx slow daq chassis | All parts received and assembly near complete, small problem detected because the two DSub connectors are too close together for two cables to fit at the same time. Gautam and I will make some additional slot panels tomorrow using a waterjet cutter, so we can spread the breakout boards out and remedy this.
Fast binary channels need to be spliced into DSub connectors. Aaron is on this. All other, slow connections are already wired from before and have been tested for correct pins on the backplane DIN connectors.
The Acromag modules require only a positive supply voltage between +12 and +30 VDC and draw a maximum of 2.8W at that. This raises the question if we want this supply rail to be regulated or take the raw power from the Sorensens. Consulting with Ben Abbott: The Acromags in LIGO do not operate with regulated power. We could easily accomodate the standard regulator boards D1000217 in the chassis, which is probably a good idea if we want to place any custom electronics inside the chassis in the future, for example for whitening or active lowpass filtering. |
13516
|
Mon Jan 8 20:50:01 2018 |
rana | Summary | Electronics | SR560: reworking | I replaced the NPD5565 with a LSK389 (SOIC-8 with DIP adapter). There was a noise reduction of ~30%, but not nearly as much as I expected. I wonder if I have to change the DC bias current on these to get the low noise operation?
https://photos.app.goo.gl/hsMwsif7NLscsgpx1 |
13515
|
Sun Jan 7 20:11:54 2018 |
Koji | Update | PonderSqueeze | Displacement requirements for short-term squeezing | In fact, that is my point. If we use signal recycling instead of resonant sideband extraction, the "tuning" of the SRC is opposite to the current setup. We need to change the macro length of the SRC to make 55MHz resonant with this tuning. And if we make the SRC macro length together with the PRC macro length for this reason, we need to thing again about the mode matching. Fortunately, we have the spare PRM (T=5%) which matches with this curvature. This was the motivation of my question. We may also choose to keep the current SRM because of its higher T and may want to evaluate the effect of expected mode mismatch. |
13514
|
Sun Jan 7 17:27:13 2018 |
gautam | Update | PonderSqueeze | Displacement requirements for short-term squeezing | Maybe you've accounted for this already in the Optickle simulations - but in Finesse (software), the "tuning" corresponds to the microscopic (i.e. at the nm level) position of the optics, whereas the macroscopic lengths, which determine which fields are resonant inside the various cavities, are set separately. So it is possible to change the microscopic tuning of the SRC, which need not necessarily mean that the correct resonance conditions are satisfied. If you are using the Finesse model of the 40m I gave you as a basis for your Optickle model, then the macroscopic length of the SRC in that was ~5.38m. In this configuration, the f2 (i.e. 55MHz sideband) field is resonant inside the SRC while the f1 and carrier fields are not.
If we decide to change the macroscopic length of the SRC, there may also be a small change to the requirements on the RoCs of the RC folding mirrors. Actually, come to think of it, the difference in macroscopic cavity lengths explains the slight differences in mode-matching efficiencies I was seeing between the arms and RCs I was seeing before.
Quote: |
Yes, this SRC detuning is very close to extreme signal recycling (0° in this convention), and the homodyne angle is close to the amplitude quadrature (90° in this convention).
For T(SRM) = 5% at the optimal angles (SRC detuning of -0.01° and homodyne angle of 89°), we can see 0.7 dBvac at 210 Hz.
|
|
13513
|
Sun Jan 7 11:40:58 2018 |
Kevin | Update | PonderSqueeze | Displacement requirements for short-term squeezing | Yes, this SRC detuning is very close to extreme signal recycling (0° in this convention), and the homodyne angle is close to the amplitude quadrature (90° in this convention).
For T(SRM) = 5% at the optimal angles (SRC detuning of -0.01° and homodyne angle of 89°), we can see 0.7 dBvac at 210 Hz. |
13512
|
Sun Jan 7 03:22:24 2018 |
Koji | Update | PonderSqueeze | Displacement requirements for short-term squeezing | Interesting. My understanding is that this is close to signal recycling, rather than resonant sideband extraction. Is that correct?
For signal recycling, we need to change the resonant condition of the carrier in the SRC. Thus the macroscopic SRC length needs to be changed from ~5.4m to 9.5m, 6.8m, or 4.1m.
In the case of 6.8m, SRC legnth= PRC length. This means that we can use the PRM (T=5%) as the new SRM.
Does this T(SRM)=5% change the squeezing level? |
13511
|
Sat Jan 6 23:25:18 2018 |
Kevin | Update | PonderSqueeze | Displacement requirements for short-term squeezing |
Quote: |
- ought to tune for 210 Hz (in-between powerlines) since 100 Hz is tough to work due to scattering, etc.
|
We can get 1.1 dBvac at 210 Hz.
The first two attachments are the noise budgets for these optimized angles. The third attachment shows squeezing as a function of homodyne angle and SRC detuning at 210 Hz. To stay below -1 dBvac, the homodyne angle must be kept between 88.5 and 89.7 degrees and the SRC detuning must be kept between -0.04 and 0.03 degrees. This corresponds to fixing the SRC length to within a range of 0.07/360 * 1064 nm = 200 pm. |
Attachment 1: displacement_noise.pdf
|
|
Attachment 2: noise_budget.pdf
|
|
Attachment 3: angles.pdf
|
|
13510
|
Sat Jan 6 18:27:37 2018 |
gautam | Update | General | power outage - IFO recovery | Mostly back to nominal operating conditions now.
- EX TransMon QPD is not giving any sensible output. Seems like only one quadrant is problematic, see Attachment #1. I blame team EX_Acromag for bumping some cabling somewhere. In any case, I've disabled output of the QPD, and forced the LSC servo to always use the Thorlabs "High Gain" PD for now. Dither alignment servo for X arm does not work so well with this configuration - to be investigated.
- BS Seismometer (Trillium) is still not giving any sensible output.
- I looked under the can, the little spirit level on the seismometer is well centered.
- I jiggled all the cabling to rule out any obvious loose connections - found none at the seismometer, or at the interface unit (labelled D1002694 on the front panel) in 1X5/1X6.
- All 3 axes are giving outputs with DC values of a few hundred - I guess there could've been some big earthquake in early December which screwed the internal alignment of the sensing mass in the seismometer. I don't know how to fix this.
- Attachment #2 = spectra for the 3 channels. Can't say they look very seismicy
. I've assumed the units are in um/sec.
- This is mainly bothering me in the short term because I can't use the angular feedforward on PRC alignment, which is usually quite helpful in DRMI locking.
- But I think the PRM Oplev loop is actually poorly tuned, in which case perhaps the feedforward won't really be necessary once I touch that up.
What I did today (may have missed some minor stuff but I think this is all of it):
- At EX:
- Toggled power to Thorlabs trans monitoring PD, checked that it was actually powered, squished some cables in the e- rack.
- Removed PDA55 in the green path (put there for EX laser AM/PM measurement). So green beam can now enter the X arm cavity.
- Re-connected ALS cabling.
- Turned on HV supply for EX Green PZT steering mirrors (this has to be done every time there is a power failure).
- At ITMY table:
- Removed temporary HeNe RIN/ Oplev sensing noise measurement setup. HeNe + 1" vis-coated steering mirror moved to SP table.
- Turned on ITMY/SRM Oplev HeNe.
- Undid changes on ITMY Oplev QPD and returned it to its original position.
- Centered ITMY reflected beam on this QPD.
- At vertex area
- Looked under Trillium seismometer can - I've left the clamps undone for now while we debug this problem.
- Power-cycled Trillium interface box.
- Touched up PMC alignment.
- Control room
- Recover IFO alignment using combination of IR and Green beams.
- Single arm locking recovered, dither alignment servos run to maximize arm transmission. Single arm locks holding for hours, that's good.
- The X arm dither alignment isn't working so well, the transmission never quite hits 1 and it undergoes some low frequency (T~30secs) oscillations once the transmission reaches its peak value.
- Had to do the usual ipcrm thing to get dataviewer to run on pianosa.
Next order of business:
- Recover ALS:
- aim is to replace the vertex area ALS signals derived from 532nm with their 1064nm counterparts.
- Need to touch up end PDH servos, alignment/MM into arms, and into Fibers at ends etc.
- Control the arms (with RMs misaligned) in the CARM/DARM basis using the revised ALS setup.
- Make a noise budget - specifically, we are interested in how much actuation range is required to maintain DARM control in this config.
- Recover DRMI locking
- Continue NBing.
- Do a statistical study of actuation range required for acquiring and maintaining DRMI locking.
|
Attachment 1: EX_QPD_Quad1_Faulty.pdf
|
|
Attachment 2: Trillium_faulty.pdf
|
|
13509
|
Sat Jan 6 13:47:32 2018 |
rana | Update | PonderSqueeze | Displacement requirements for short-term squeezing |
- ought to tune for 210 Hz (in-between powerlines) since 100 Hz is tough to work due to scattering, etc.
- rename DAC - I think what this curve shows is really the coil driver noise. The DAC noise we can always filter out with the dewhitening board; i.e. once we have 1000x attenuation between the DAC and the coil driver input, DAC noise is not dominant.
|
13508
|
Sat Jan 6 05:18:12 2018 |
Kevin | Update | PonderSqueeze | Displacement requirements for short-term squeezing | I have been looking into whether we can observe squeezing on a short timescale. The simulations I show here say that we can get 2 dBvac of squeezing at about 120 Hz using extreme signal recycling.
The parameters used here are
- 100 ppm transmissivity on the folding mirrors giving a PRC gain of 40.
- 10 kΩ series resistance for the ETMs; 15 kΩ series resistance for the ITMs.
- 1 W incident on the back of PRM.
- PD quantum efficiency 0.88.
The first attachment shows the displacement noise. The red curve labeled vacuum is the standard unsqueezed vacuum noise which we need to beat. The second attachment shows the same noise budget as a ratio of the noise sources to the vacuum noise.
This homodyne angle and SRC detuning give about the maximum amount of squeezing. However, there's quite a bit of flexibility and if there are other considerations, such as 100 Hz being too low, we should be able to optimize these angles (even with more pessimistic values of the above parameters) to see at least 0.2 dBvac around 400 Hz. |
Attachment 1: displacement_noise.pdf
|
|
Attachment 2: noise_budget.pdf
|
|
13507
|
Fri Jan 5 22:19:53 2018 |
gautam | Update | General | power outage - timing error | Just putting the relevant line from email from Rolf which at least identifies the problem here:
Looks like FB time is actually off by 1 year, as your timing system does not get year info.
There still seems to be something funky with the X arm transmission PDs - I can't seem to get the triggering to switch between the QPD and the Thorlabs PD, and the QPD signal seems to be wildly fluctuating by several orders of magnitude from 0.01-100. The c1iscex FE was pulled out, and it seemed to me like someone was doing some cable re-arrangement at the X end.
I will look into this tomorrow.
Quote: |
Rolf came here in the morning, but not sure what he did or if Jamie remotely did something. But the screen is green.
|
|
13506
|
Fri Jan 5 21:54:28 2018 |
rana | Update | General | power outage - timing error | Rolf came here in the morning, but not sure what he did or if Jamie remotely did something. But the screen is green. |
Attachment 1: huh.png
|
|
13505
|
Fri Jan 5 19:19:25 2018 |
rana | Configuration | SEI | Barry Controls 'air puck' instead of 'VOPO style' breadboard | We've been thinking about putting in a blade spring / wire based aluminum breadboard on top of the ETM & ITM stacks to get an extra factor of 10 in seismic attenuation.
Today Koji and I wondered about whether we could instead put something on the outside of the chambers. We have frozen the STACIS system because it produces a lot of excess noise below 1 Hz while isolating in the 5-50 Hz band.
But there is a small gap between the STACIS and the blue crossbeams that attache to the beams that go into the vacuum to support the stack. One possibility is to put in a small compliant piece in there to gives us some isolation in the 10-30 Hz band where we are using up a lot of the control range. The SLM series mounts from Barry Controls seems to do the trick. Depending on the load, we can get a 3-4 Hz resonant frequency.
Steve, can you please figure out how to measure what the vertical load is on each of the STACIS? |
Attachment 1: mm_slm.jpg
|
|
Attachment 2: Screen_Shot_2018-01-05_at_7.25.47_PM.png
|
|
13504
|
Fri Jan 5 17:50:47 2018 |
rana | Configuration | Computers | motif on nodus | I had to do 'sudo yum install motif' on nodus so that we could get libXm.so.4 so that we could run MEDM. Works now. |
|