ID |
Date |
Author |
Type |
Category |
Subject |
12141
|
Tue May 31 16:52:58 2016 |
Steve | Update | safety | NONO |
Please do not place anything on the top of the cabinets that is not tied down. It will end up on our head in an earth quake.
|
Attachment 1: nono.jpg
|
|
12142
|
Wed Jun 1 09:06:38 2016 |
Steve | Update | LSC | New stands for TransMon/Oplev QPDs |
Machined from I-beam 6061 T6 Aluminum 5" x 0.5 x 3.25
Quote: |
As we realized during the EX table switch, the transmitted beam height from the arm is not exactly 4" relative to the endtable, it is more like 4.75" at the X-end (yet to be investigated at the Y-end). As a result, the present configuration involves the steering optics immediately before the Oplev and TransMon QPDs sending the beam downwards at about 5 degrees. Although this isn't an extremely large angle, we would like to have things more level. For this purpose, Steve has ordered some Aluminium I-beams (1/2 " thick) which we can cut to size as we require. The idea is to have the QPD enclosures mounted on these beams and then clamped to the table. One concern was electrical isolation - but Steve thinks Delrin washers between the QPD enclosure and the mount will suffice. We will move ahead with getting these machined once I investigate the situation at the Y end as well.. The I beams should be here sometime next week...
|
Atm2, version 2 "pdstand" will allow you to clamp from any direction ( Koji was right ) |
Attachment 1: pdIb.PDF
|
|
Attachment 2: pdstand.pdf
|
|
12143
|
Wed Jun 1 11:19:14 2016 |
Varun | Update | General | Update of work till now |
Completed:
Wrote and tested a code for AGC using cavity transmission signal and length error signal.
Wrote and tested a code for frequency shifting (downconversion) using mixing and LPF
Wrote a code for whitening using FFT.
Altium working on cit40m iMac
Plans:
Writing codes for Frequency warping and whitening in time domain.
Implement AGC and frequency shifting on the real time control system.
Calculate requirements for Anti-aliasing filter. |
12144
|
Wed Jun 1 15:01:56 2016 |
Steve | Update | SUS | wire standoffs update |
There are some issues with 5 mm sapphire prism Atm5. It will cause interference between one of the prisms and the Side OSEM.
Here are some drawings to see the issues with larger wire standoff.
The 2 mm prism will work.with a 1 mm longer dumbell.
Quotes requested from http://photomachining.com/laser-micromachining-photomachining-contact.html and http://www.optocity.com/
|
Attachment 1: 06011603.PDF
|
|
Attachment 2: 06011602.PDF
|
|
Attachment 3: sapphire_stand_off_v2.pdf
|
|
Attachment 4: side_OSEM_ETMY.jpg
|
|
Attachment 5: 5p2wsf.png
|
|
12145
|
Wed Jun 1 16:28:28 2016 |
ericq | Update | Electronics | Common board Op amp input offsets |
I used a Eurocard extension board to peek at the inputs and outputs of each of the gain-ladder AD829s on input B of the CM board in the +31dB configuration with the input terminated. (i.e with the following stages active in this order: +16dB, +8dB, +4dB, +2dB, +1dB).
The voltages I observed imply that the +8dB stage has an input voltage offset of -2mV, whereas all the other positive gain stages show around +-0.5mV. This could explain the shift observed at the +15->+16 transition. (However, since both input channels show a jump here, maybe its something more systemic about the board...)
In any case, it should be simple enough to swap out a new AD829 in place of U9B and see if it improves things, before getting too deep into the muck. (In principle, the AD829 has offset nulling pins, but I'm not sure how to do it in a non-hacky way since the board doesn't have any pads for it.) |
12146
|
Thu Jun 2 16:35:44 2016 |
Koji | Update | SUS | wire standoffs update |
Gap of the prism from the mirror
Sag: s = R(1-Cos[ArcSin[d/2/R]])
- Mirror curvature sag for 2mm prism (R=37.75mm): s=13um
- Minimum gap: 20um => s=33um => R=15mm
- Nominal gap: 35um => s=48um => R=10mm
- Maximum gap: 50um => s=63um => R=8mm
The second figure shows somewhat realistic arrangement of the pieces |
Attachment 1: sapphire_stand_off_v3.pdf
|
|
Attachment 2: arrangement-v3.pdf
|
|
12147
|
Fri Jun 3 12:53:44 2016 |
ericq | Update | Electronics | Common board Op amp input offsets |
I replaced some of the AD829s with other AD829s, but the offset situation didn't improve.
However, I figured that we don't really need the ~100MHZ bandwidth of the AD829, since the IMC loop limits us to a ~10kHz CARM bandwidth. Also, since we don't routinely use IN2 for anything, I felt free to try something else.
Specifically, I replaced all of the positive gain AD829s in the input 2 gain ladder with OP27s (U8B->U12B on D1500308), which should have input offset voltages ~30x lower than the AD829s.
Here is a comparison of the outputs these configurations perform, normalized to the output at the +0dB gain setting - where all of the op amps in the gain ladder are bypassed.

So, most of the transitions now result in an output offset change of less than 0.5mV, which is nice.
The exception seems to be where the +8dB stage is switched in or out. I may try replacing this one, as these transitions cause a lock loss now when trying to lock the arm with high bandwidth using POY. |
12148
|
Fri Jun 3 13:05:18 2016 |
ericq | Update | CDS | CDS Notes |
Some CDS related things:
Keith Thorne has told us about a potential fix for our framebuilder woes. Jamie is going to be at the 40m next week to implement this, which could interfere with normal interferometer operation - so plan accordingly.
I spent a little time doing some plumbing in the realtime models for Varun's audio processing work. Specifically, I tried to spin up a new model (C1DAF), running on the c1lsc machine. This included:
- Removing the unused TT3 and TT4 parts from the IOO block in c1ass.mdl, freeing up some DAC outputs on the LSC rack
- Adding an output row to the LSC input matrix which pipes to a shared memory IPC block. (This seemed like the simplest way for the DAFI model to have access to lots of signals with minimal overhead).
- Removing two unused ADC inputs from c1lsc.mdl (that went to things like PD_XXX), to give c1daf.mdl the required two ADC inputs - and to give us the option of feeding in some analog signals.
- Editing the rtsystab file to include c1daf in the list of models that run on c1lsc
- Editing the existing DAFI .mdl file (which just looked like an old recolored cut-n-paste of c1ioo.mdl) to accept the IPC and ADC connections, and one DAC output that would go to the fibox.
The simple DAFI model compiled and installed without complaint, but doesn't succesfully start. For some reason, the frontend never takes the CPU offline. Jamie will help with this next week. Since things aren't working, these changes have not been commited to the userapps svn. |
12149
|
Fri Jun 3 14:24:13 2016 |
Steve | Update | SUS | local EQ 3.1 m |
Local EQ 3.1 mag at Jun 2, 2016 11:06:16 PM UTC, Muscoy CA........no damage
Our STS should seen this shake.
|
Attachment 1: eq3.1mMuscoyCa.png
|
|
12150
|
Fri Jun 3 17:56:14 2016 |
Varun | Update | General | DAFI update |
Wrote and tested a phase vocoder, with two of its applications:
1) Time scaling: This enables change of time duration without affecting the pitch.
2) Frequency warping: This changes the pitch of the sound without affecting the time duration.
1 & 2 tested offline with cavity transmission signal. 1) gives speedup of 2, and 2 gives frequency warping (pitch lowering by a factor of 2)
codes uploaded on github repo |
12151
|
Mon Jun 6 16:41:36 2016 |
ericq | Update | CDS | FB upgrade work |
Barring objections, starting tomorrow morning, Jamie will be testing the new FB code. The IFO will not be available for other use while this is ongoing. |
12152
|
Tue Jun 7 11:12:47 2016 |
jamie | Update | CDS | DAQD UPGRADE WORK UNDERWAY |
I am re-starting work on the daqd upgrade again now. Expect the daqd to be offline for most of the day. I will report progress. |
12153
|
Tue Jun 7 17:21:13 2016 |
Aakash | Update | General | SURF 2016 |
Hi!
I am Aakash Patil. I will be working at the 40m lab as a SURF student with Gautam Venugopalan on enclosures for seismometers to shield them from thermal and magnetic fluctuations. This week I will be working on the development of hardware for four probe measurement along with a constant current source. It will effectively help us in accurate temperature measurement throughout the development of enclosure.
|
12154
|
Tue Jun 7 18:20:18 2016 |
Varun | Update | General | DAFI update |
Tried to implement AGC on FE. Had some trouble bringing the code into the correct form. It looks okay now. However, this agc code as well as idenntity code (input = output) doesnt seem to build on the c1lsc FE. Have not tried too many debugging steps yet, will come and check the problem tomorrow.
-Varun
Quote: |
Wrote and tested a phase vocoder, with two of its applications:
1) Time scaling: This enables change of time duration without affecting the pitch.
2) Frequency warping: This changes the pitch of the sound without affecting the time duration.
1 & 2 tested offline with cavity transmission signal. 1) gives speedup of 2, and 2 gives frequency warping (pitch lowering by a factor of 2)
codes uploaded on github repo
|
|
12155
|
Tue Jun 7 20:49:50 2016 |
jamie | Update | CDS | DAQD work ongoing |
Summary: new daqd code running overnight test on fb1. Stability issues persist.
The code is from Keith's "tests/advLigoRTS-40m" branch, which is a branch of the current trunk. It's supposed to include patches to fix the crashes when multiple frame types are written to disk at the same time. However, the issue is not fixed:
2016-06-07_20:38:55 about to write frame @ 1149392336
2016-06-07_20:38:55 Begin Full WriteFrame()
2016-06-07_20:38:57 full frame write done in 2seconds
2016-06-07_20:39:11 about to write frame @ 1149392352
2016-06-07_20:39:11 Begin Full WriteFrame()
2016-06-07_20:39:13 full frame write done in 2seconds
2016-06-07_20:39:27 about to write frame @ 1149392368
2016-06-07_20:39:27 Begin Full WriteFrame()
2016-06-07_20:39:29 full frame write done in 2seconds
2016-06-07_20:39:43 about to write second trend frame @ 1149391800
2016-06-07_20:39:43 Begin second trend WriteFrame()
2016-06-07_20:39:43 about to write frame @ 1149392384
2016-06-07_20:39:43 Begin Full WriteFrame()
2016-06-07_20:39:44 full frame write done in 1seconds
2016-06-07_20:39:59 about to write frame @ 1149392400
2016-06-07_20:40:04 Begin Full WriteFrame()
2016-06-07_20:40:04 Second trend frame write done in 21 seconds
2016-06-07_20:40:14 [Tue Jun 7 20:40:14 2016] main profiler warning: 1 empty blocks in the buffer
2016-06-07_20:40:15 [Tue Jun 7 20:40:15 2016] main profiler warning: 0 empty blocks in the buffer
2016-06-07_20:40:16 [Tue Jun 7 20:40:16 2016] main profiler warning: 0 empty blocks in the buffer
2016-06-07_20:40:17 [Tue Jun 7 20:40:17 2016] main profiler warning: 0 empty blocks in the buffer
2016-06-07_20:40:18 [Tue Jun 7 20:40:18 2016] main profiler warning: 0 empty blocks in the buffer
2016-06-07_20:40:19 [Tue Jun 7 20:40:19 2016] main profiler warning: 0 empty blocks in the buffer
2016-06-07_20:40:20 [Tue Jun 7 20:40:20 2016] main profiler warning: 0 empty blocks in the buffer
2016-06-07_20:40:21 [Tue Jun 7 20:40:21 2016] main profiler warning: 0 empty blocks in the buffer
2016-06-07_20:40:22 [Tue Jun 7 20:40:22 2016] main profiler warning: 0 empty blocks in the buffer
2016-06-07_20:40:23 [Tue Jun 7 20:40:23 2016] main profiler warning: 0 empty blocks in the buffer
This failure comes when a full frame (1149392384+16) is written to disk at the same time as a second trend (1149391800+600). It seems like every time this happens daqd crashes.
I have seen other stability issues as well, maybe caused by mx flakiness, or some sort of GPS time synchronization issue caused by our lack of IRIG-B cards. I'm going to look to see if I can get the GPS issue taken care of so we take that out of the picture.
For the last couple of hours I've only seen issues with the frame writing every 20 minutes, when the full and second trend frames happen to be written at the same time. Running overnight to gather more statistics. |
12156
|
Wed Jun 8 08:34:55 2016 |
jamie | Update | CDS | DAQD work ongoing |
38 restarts overnight. Problem definitely not fixed. I'll be reverting back to old daqd and fb this morning. Then regroup and evaluate options. |
12157
|
Wed Jun 8 10:20:14 2016 |
Steve | Update | safety | SURF 2016 safety |
Aakash Patil received 40m specific basic safety training.
Quote: |
Quote: |
Hello, I am Varun Kelkar. I will be working at the 40m lab as a SURF student this summer with Eric Quintero on Audio processing for real time control system signals. This week I will mostly be working on implementing basic DSP C-code offline. Currently I am trying to write a code for noise whitening.
-Varun
|
Varun has received 40m specific basic safety training today.
|
|
12159
|
Wed Jun 8 16:12:38 2016 |
Varun | Update | General | DAFI update |
Summary: I am implementing digital audio filtering on various interferometer signals in order to listen to the processed audio which will help in characterizing and noise reduction in the interferometer. Following is an implementation of an Automatic Gain control (AGC) block on an LSC input signal.
Details of AGC: Currently, the AGC code implemented on FE takes input to fill a frame, then calculates the power in each frame and gives an appropriate gain to it, so that the new power content is to the required level. It is then written to the output, frame by frame. The frame is currently a rectangular window. The frame length and hop size can be adjusted. Current values are as follows:
frame length is 512 samples
hop length is 128 samples.
The input and output are delayed by 1 frame.
Details of testing: Attachment 1 shows a simulink diagram of the DAF system. Eric made this and I modified it later on. Testing was done using signal from the "LSC1" channel. Attachments 2 and 3 show aquired input and output of the AGC respectively. Gain of the preamp of the LSC input signal was varied over a total time span of 200 s. Each gain value was kept for a duration of about 20 seconds. The varying power levels can be seen in the input plot.
The output shows a uniform power level throughout.
Quote: |
Tried to implement AGC on FE. Had some trouble bringing the code into the correct form. It looks okay now. However, this agc code as well as idenntity code (input = output) doesnt seem to build on the c1lsc FE. Have not tried too many debugging steps yet, will come and check the problem tomorrow.
-Varun
Quote: |
Wrote and tested a phase vocoder, with two of its applications:
1) Time scaling: This enables change of time duration without affecting the pitch.
2) Frequency warping: This changes the pitch of the sound without affecting the time duration.
1 & 2 tested offline with cavity transmission signal. 1) gives speedup of 2, and 2 gives frequency warping (pitch lowering by a factor of 2)
codes uploaded on github repo
|
|
|
Attachment 1: dafi.png
|
|
Attachment 2: agcin.pdf
|
|
Attachment 3: agcout.pdf
|
|
12160
|
Thu Jun 9 09:57:06 2016 |
Aakash | Update | General | Seismometer Enclosure Development |
Me and Gautam yesterday opened the tilt-free seismometer enclosure to see if we could use the thermocouples and
other things previously used by Megan. But we are planning to get new four-wire RTDs for our work.
For the next day or two, I will be trying to set up Acromag Busworks terminal so that the data logging during
this enclosure development experiment becomes perfect and easy. Johannes has sent me the wiki page URL for the same. |
12162
|
Thu Jun 9 15:14:46 2016 |
jamie | Update | CDS | old fb restarted, test of new daqdon fb1 aborted for time being |
I've restarted the old daqd on fb until I can figure out what's going on with the symmetricom driver on fb1.
Steve: Jamie with hair.... long time ago
|
Attachment 1: Jamie.jpg
|
|
12163
|
Thu Jun 9 18:54:40 2016 |
Aakash | Update | General | About Acromag | SURF 2016 |
Today I tried to setup Acromag Busworks card. I was able to calibrate and test it over USB but I couldn't test it over ethernet. I'll utilize a few hours tomorrow to test it over ethernet and see if I can make it work. I have also found a few RTDs which I want to use for temperature sensing via four probe method. So, tomorrow I'll get these RTD details revived by Gautam and Steve.
I was wondering if we have a basic DAQ card with maybe 4 channels which is simple to setup like NI DAQ cards. |
12164
|
Thu Jun 9 19:08:58 2016 |
Varun | Update | Electronics | Anti-Aliasing Filter update |
Eric gave me a psd plot of a signal which would be the input of a channel of the AA filter. the Nyquist freq. is about 32.8kHz.
Following are plots depicting the ratio of the aliased downconverted signal and the signal below 32.8 kHz. The first plot is for (to-be) aliased signal frequencies from 32.8 to 65.5k, and the second plot is for (to-be) aliased signals from 65.5k to 98.3k. In case of the first plot, the 36kHz peak will alias to 29kHz, and is about 30 times (29.5dB) greater than the signal there. Hence, the filter should give about 70dB attenuation there. Since this attenuation is not required by most other frequencies up to 65.5k, an option could be to use a notch filter to remove the frequency peak at 36k, and put a requirement of 45-50 dB attenuation on other frequencies.
In case of the second plot, the frequencies between 90 to 100k again need to be attenuated by more than 70 dB. However, if there is a -20dB/decade slope in stop band, we already have about 10 dB attenuation here as compared to around 32k.
The X axis of both plots is in Hz. |
Attachment 1: 32to65.jpg
|
|
Attachment 2: 65to98.png
|
|
12165
|
Fri Jun 10 09:52:51 2016 |
Steve | Update | SUS | EQ 5.2 mag Borego Spring |
EQ 5.2 mag at Jun 10, 8:04 am UTC, Borego Spring, CA ~150 mi away.........no obvoius damage, damping restored, MC is locking, arms are flashing
|
Attachment 1: 5.2mBoregoSpring.png
|
|
Attachment 2: eqBSs.png
|
|
12168
|
Fri Jun 10 16:19:03 2016 |
ericq | Update | SUS | ETMX watch |
ETMX has been jumping around again lately. Just now, I zeroed the ETMX alignment offsets in the SUS model, and centered the ETMX oplev spot via slow machine sliders. OSEM damping is on, oplev damping is off. Let's see how it moves around in the next day or so.
GPS: 1149635923
UTC: Jun 10 2016 23:18:26 |
12169
|
Fri Jun 10 18:16:59 2016 |
varun | Update | PSL | Realignment of pre mode cleaner |
The mode cleaner was misaligned probably due to the earthquake (the drop in the MC transmitted value slightly after utc 7:38:52 as seen in the second plot). The plots show PMC transmitted and MC sum signals from 10th june 07:10:08 UTC over a duration of 17 hrs. The PMC was realigned at about 4-4:15 pm today by rana. This can be seen in the first plot. |
Attachment 1: pmctrans_mcsum_signals.png
|
|
12170
|
Mon Jun 13 09:08:17 2016 |
Steve | Update | PSL | PMC slow drift |
The PMC transmission slow degration or it's input beam is not stable.
|
Attachment 1: PMCslowDrift.png
|
|
12171
|
Mon Jun 13 10:01:58 2016 |
Steve | Update | SUS | ETMX jumps |
Quote: |
ETMX has been jumping around again lately. Just now, I zeroed the ETMX alignment offsets in the SUS model, and centered the ETMX oplev spot via slow machine sliders. OSEM damping is on, oplev damping is off. Let's see how it moves around in the next day or so.
GPS: 1149635923
UTC: Jun 10 2016 23:18:26
|
|
Attachment 1: noDamping24hrs.png
|
|
Attachment 2: ETMXjumps.png
|
|
12172
|
Mon Jun 13 19:30:58 2016 |
Aakash | Update | General | EPICS Installation | SURF 2016 |
About acquiring data: Initially I couldn't start with proper Acromag setup as the Raspberry pi had a faulty SD card slot. Then Gautam gave me a working pi on which I tried to install EPICS. I spent quite a time today but couldn't setup acromag over ethernet. But, it would be great if we have a USB DAQ card. I have found a good one here http://www.mccdaq.com/PDFs/specs/USB-200-Series-data.pdf It costs around 106$ including shipping (It comes with some free softwares for acquiring data) . Also, I know an another python based 12bit DAQ card (with an inbuilt constant current source) which is made by IUAC, Delhi and more information can be found here http://www.iuac.res.in/~elab/expeyes/Documents/eyesj-progman.pdf It costs around 60$ including shipping.
About temperature sensing: The RTD which I found on Omega's list is having a temperature resolution of 0.1 deg C. I have also asked them for the one with good resolution. Also according to their reply, they have not performed any noise characteristics study for those RTDs.
|
12173
|
Mon Jun 13 20:01:30 2016 |
varun | Update | CDS | DAFI GUI update |
Summary: I am implementing digital audio filtering on various interferometer signals in order to listen to the processed audio which will help in characterizing and noise reduction in the interferometer. following is a summary of the gui i have made towards a general purpose DAF module linked to the LSC.
Details: attachment 1 shows the top level overview of the daf module.
The "INPUTS" button shown redirects to the medm screen shown in attachment 2, which is a collection of inputs going into the module.
Each of the buttons shown in "C1DAFI_INPUTS.png" is further linked to various i/o boxes like adc1, adc2, lsc signal and exitation. An example is shown in attachment 3. This is the specific I/O box for the LSC signal.
The field labelled "INPUT_MTRX" is linked to a matrix which routes these 4 inputs to various DSP blocks. Similarly, the "OUTPUT_MTRX" tab is useful for choosing which output goes to the speaker.
Time and computational load monitoring is done in the "GDS_TP" tab which links to the medm screen shown in attachment 4.
Currently the AGC is successfully implemented as one of the DSP block. The details of the AGC implementation were given in a previous elog: https://nodus.ligo.caltech.edu:8081/40m/12159
I need to make a few changes to the code for Frequency Shifting and Whitening before uploading them on the FE. I will put the details soon.
Some more things that I think need to be added:
1) "Enable" buttons for each of the DSP blocks.
2) Labels for each of the matrix elements.
3) Further headers and other description for each of the tabs |
Attachment 1: C1DAF_OVERVIEW.png
|
|
Attachment 2: C1DAF_INPUTS.png
|
|
Attachment 3: C1DAF_LSC.png
|
|
Attachment 4: MONITOR.png
|
|
12174
|
Tue Jun 14 10:13:34 2016 |
Steve | Update | VAC | temporary N2 supply line |
The drill room floor will be retiled Thursday, June 16. Temporary nitrogen line set up will allow emptying the hole area.
Ifo room entry will be through control room.
|
Attachment 1: afterN2work.png
|
|
12176
|
Tue Jun 14 11:52:08 2016 |
Johannes | Update | General | EPICS Installation | SURF 2016 |
We generally want to keep the configuration of the 40m close to that of the LIGO sites, which is why we chose BusWorks, and it is also being established as a standard in other labs on campus. Of course any suitable DAQ system can do the job, but to stay relevant we generally try to avoid patchwork solutions when possible. Did you follow Aidan's instructions to the book? I haven't set up a system myself, yet, so I cannot say how difficult this is. If it just won't work with the Raspberry Pi, you could still try using a traditional computer.
Alternatively, following Jamie's suggestions, I'm currently looking into using python for the modbus communications (there seem to be at least a few python packages that can do this), which would reportedly make the interfacing and integration a lot easier. I'll let you know when I make any progress on this.
Quote: |
About acquiring data: Initially I couldn't start with proper Acromag setup as the Raspberry pi had a faulty SD card slot. Then Gautam gave me a working pi on which I tried to install EPICS. I spent quite a time today but couldn't setup acromag over ethernet. But, it would be great if we have a USB DAQ card. I have found a good one here http://www.mccdaq.com/PDFs/specs/USB-200-Series-data.pdf It costs around 106$ including shipping (It comes with some free softwares for acquiring data) . Also, I know an another python based 12bit DAQ card (with an inbuilt constant current source) which is made by IUAC, Delhi and more information can be found here http://www.iuac.res.in/~elab/expeyes/Documents/eyesj-progman.pdf It costs around 60$ including shipping.
About temperature sensing: The RTD which I found on Omega's list is having a temperature resolution of 0.1 deg C. I have also asked them for the one with good resolution. Also according to their reply, they have not performed any noise characteristics study for those RTDs.
|
|
12177
|
Tue Jun 14 15:55:17 2016 |
ericq | Update | SUS | ETMX watch |
Within two hours, it was already all over the place.

It has been Decided: we will assemble a suspension with the spare ETM optic with the current-generation standoff for installation ASAP. I.e. no new custom parts. We will continue pursuing the new standoff design, but we need our interferometer back. |
12178
|
Tue Jun 14 16:53:16 2016 |
rana | Update | SUS | ETMX watch |
What about ETMY? and are these really microradians or just some made up cal? |
12179
|
Tue Jun 14 19:37:40 2016 |
jamie | Update | CDS | Overnight daqd test underway |
I'm running another overnight test with new daqd software on fb1. The normal daqd process on fb has been shutdown, and the front ends are sending their signals to fb1.
fb1 is running separate data concentrator (dc) and frame writer (fw) processes, to see if this is a more stable configuration than the all-in-one framebuilder (fb) that we have been trying to run with. I'll report on the test tomorrow. |
12180
|
Tue Jun 14 20:10:19 2016 |
varun | Update | CDS | DAFI GUI update |
I have added Enable buttons for each of the DSP blocks, and labels for the matrix elements. The input matrix takes inputs from each of the 4 channels: ADC1, ADC2, LSC and EXC, and routes them to the audio processing blocks (attachment 2). The output matrix (attachment 3) takes the outputs of the various DSP blocks and routes them to the output and then to the speakers. |
Attachment 1: C1DAF_OVERVIEW.png
|
|
Attachment 2: input_matrix.png
|
|
Attachment 3: output_matrix.png
|
|
12181
|
Wed Jun 15 09:52:02 2016 |
jamie | Update | CDS | Very encouraging results from overnight split daqd test |
Very encouraging results from the test last night. The new configuration did not crash once overnight, and seemed to write out full, second trend, and minute trend frames without issue . However, full validity of all the written out frames has not been confirmed.
overview
The configuration under test involves two separate daqd binaries instead of one. We usually run with what is referred to as a "framebuilder" (fb) configuration:
- fb: a single daqd binary that:
- collect the data from the front ends
- coallate full data into frame file format
- calculates trend data
- writes frame files to disk.
The current configuration separates the tasks into multiple separate binaries: a "data concentrator" (dc) and a "frame writer" (fw):
- dc:
- collect data from front ends
- coallate full data into frame file format
- broadcasts frame files over local network
- fw:
- receives frame files from broadcast
- calculates trend data
- writes frame files to disk
This configuration is more like what is run at the sites, where all the various components are separate and run on separate hardware. In our case, I tried just running the two binaries on the same machine, with the broadcast going over the loopback interface. None of the systems that use separated daqd tasks see the failures that we've been seeing with the all-in-one fb configuration (and other sites like AEI have also seen).
My guess is that there's some busted semaphore somewhere in daqd that's being shared between the concentrator and writer components. The writer component probably aquires the lock while it's writing out the frame, which prevents the concentrator for doing what it needs to be doing while the frame is being written out. That causes the concentrator to lock up and die if the frame writing takes too long (which it seems to almost necessarily do, especially when trend frames are also being written out).
results
The current configuration hasn't been tweaked or optimized at all. There is of course basically no documentation on the meaning of the various daqdrc directives. Hopefully I can get Keith Thorne to help me figure out a well optimized configuration.
There is at least one problem whereby the fw component is issuing an excessively large number of re-transmission requests:
2016-06-15_09:46:22 [Wed Jun 15 09:46:22 2016] Ask for retransmission of 6 packets; port 7097
2016-06-15_09:46:22 [Wed Jun 15 09:46:22 2016] Ask for retransmission of 8 packets; port 7097
2016-06-15_09:46:22 [Wed Jun 15 09:46:22 2016] Ask for retransmission of 3 packets; port 7097
2016-06-15_09:46:22 [Wed Jun 15 09:46:22 2016] Ask for retransmission of 5 packets; port 7097
2016-06-15_09:46:22 [Wed Jun 15 09:46:22 2016] Ask for retransmission of 5 packets; port 7097
2016-06-15_09:46:22 [Wed Jun 15 09:46:22 2016] Ask for retransmission of 5 packets; port 7097
2016-06-15_09:46:22 [Wed Jun 15 09:46:22 2016] Ask for retransmission of 5 packets; port 7097
2016-06-15_09:46:22 [Wed Jun 15 09:46:22 2016] Ask for retransmission of 6 packets; port 7097
2016-06-15_09:46:23 [Wed Jun 15 09:46:23 2016] Ask for retransmission of 1 packets; port 7097
It's unclear why. Presumably the retransmissions requests are being honored, and the fw eventually gets the data it needs. Otherwise I would hope that there would be the appropriate errors.
The data is being written out as expected:
full/11500: total 182G
drwxr-xr-x 2 controls controls 132K Jun 15 09:37 .
-rw-r--r-- 1 controls controls 69M Jun 15 09:37 C-R-1150043856-16.gwf
-rw-r--r-- 1 controls controls 68M Jun 15 09:37 C-R-1150043840-16.gwf
-rw-r--r-- 1 controls controls 68M Jun 15 09:37 C-R-1150043824-16.gwf
-rw-r--r-- 1 controls controls 69M Jun 15 09:36 C-R-1150043808-16.gwf
-rw-r--r-- 1 controls controls 69M Jun 15 09:36 C-R-1150043792-16.gwf
-rw-r--r-- 1 controls controls 68M Jun 15 09:36 C-R-1150043776-16.gwf
-rw-r--r-- 1 controls controls 68M Jun 15 09:36 C-R-1150043760-16.gwf
-rw-r--r-- 1 controls controls 69M Jun 15 09:35 C-R-1150043744-16.gwf
trend/second/11500: total 11G
drwxr-xr-x 2 controls controls 4.0K Jun 15 09:29 .
-rw-r--r-- 1 controls controls 148M Jun 15 09:29 C-T-1150042800-600.gwf
-rw-r--r-- 1 controls controls 148M Jun 15 09:19 C-T-1150042200-600.gwf
-rw-r--r-- 1 controls controls 148M Jun 15 09:09 C-T-1150041600-600.gwf
-rw-r--r-- 1 controls controls 148M Jun 15 08:59 C-T-1150041000-600.gwf
-rw-r--r-- 1 controls controls 148M Jun 15 08:49 C-T-1150040400-600.gwf
-rw-r--r-- 1 controls controls 148M Jun 15 08:39 C-T-1150039800-600.gwf
-rw-r--r-- 1 controls controls 148M Jun 15 08:29 C-T-1150039200-600.gwf
-rw-r--r-- 1 controls controls 148M Jun 15 08:19 C-T-1150038600-600.gwf
trend/minute/11500: total 152M
drwxr-xr-x 2 controls controls 4.0K Jun 15 07:27 .
-rw-r--r-- 1 controls controls 51M Jun 15 07:27 C-M-1150023600-7200.gwf
-rw-r--r-- 1 controls controls 51M Jun 15 04:31 C-M-1150012800-7200.gwf
-rw-r--r-- 1 controls controls 51M Jun 15 01:27 C-M-1150002000-7200.gwf
The frame sizes look more or less as expected, and they seem to be valid as determined with some quick checks with the framecpp command line utilities. |
12183
|
Wed Jun 15 11:21:51 2016 |
jamie | Update | CDS | still work to do to transition to new configuration/code |
Just to be clear, there's still quite a bit of work to fully transition the 40m to this new system/configuration. Once we determine a good configuration we need to complete the install, and modify the setup to run the two binaries instead of just the one. The data is also being written to a raid on the new fb1, and we need to decide if we should use this new raid, or try to figure out how to move the old jetstor raid to the new fb1 machine. |
12185
|
Wed Jun 15 22:12:55 2016 |
varun | Update | CDS | DAFI update: stereo output |
I wish to have stereo audio output for the DAF module. Hence, there needs to be a second output from the DAF. I added this second output to the model. Following are the details:
FiBox: It consists of two analog inputs which are digitized and multiplexed and transmitted optically. (only 1 fiber is needed due to multiplexing). Attachment 1 shows the fibox with its 2 analog inputs (one of which, is connected), and 1 fiber output. The output of the DAF goes to the FiBox. Until today, the Fibox recieved only 1 analog input. This analog signal comes from the DAC-8 (count starting from 0), which is located at "CH 1 OUT" SMA output in the "MONITORS" bin on the racks (attachment 2).
I have added another output channel to the DAF model both in software and in hardware. The DAF now also uses DAC-9 analog output which goes to the second analog input of the FiBox. The DAC-9 output is located at "CH 2 OUT" SMA output in the "MONITORS" bin on the racks (attachment 4).
After making the changes, the Fibox is shown in attacment 3.
Testing: The LSC input on passing through the DAF block is given through two different DAC outputs, to the same Fibox channel (one after the other), and the output is heard. More concrete testing will be done tomorrow. It will be as follows:
1) Currently, I need to search for a suitable cable that would connect the second channel of the output fibox to the audio mixer. After doing this, end to end testing of both channels will be done.
2) I could not access the AWG, probably because the DAQ was offline today afternoon. Using a signal from the AWG will give a more concrete testing of the stereo output.
3) After this, I will separate the two channels of the stereo completely (currectly they are seperated only at the DAF output stage)
4) I also will edit the medm gui appropriately.
Quote: |
I have added Enable buttons for each of the DSP blocks, and labels for the matrix elements. The input matrix takes inputs from each of the 4 channels: ADC1, ADC2, LSC and EXC, and routes them to the audio processing blocks (attachment 2). The output matrix (attachment 3) takes the outputs of the various DSP blocks and routes them to the output and then to the speakers.
|
|
Attachment 1: IMG_20160615_145535907.jpg
|
|
Attachment 2: IMG_20160615_145413005_HDR.jpg
|
|
Attachment 3: IMG_20160616_101229499.jpg
|
|
Attachment 4: IMG_20160616_101157096.jpg
|
|
12186
|
Thu Jun 16 08:52:14 2016 |
Steve | Update | General | illuminators turned off |
PSL, BS, ITMY and ETMX the illuminators were left on over night. |
12187
|
Thu Jun 16 11:10:17 2016 |
Steve | Update | SUS | spare ETMX optics preparation to be hanged |
D Location
Number on
Drawing
|
Component
Name
|
Baked Clean
Pieces Needed
|
Pieces
In Stock
(on tower )
|
Notes |
|
|
|
|
|
31,20,19,13 |
viton tips |
|
not cut yet |
baked material in stock |
30 |
6-32x0.75" stops |
4 |
(4) |
|
29 |
steel music wire 0.017" |
not baked |
on roll |
needs good wipes |
28 |
1/4 "washer |
4 |
(4) |
|
27 |
lock washer |
4 |
50 |
install |
26 |
Ag plated 1/4-20x1.25 |
4 |
(4) |
|
25 |
Ag plated1/4-25x.75 & not plated |
20 |
(20) |
|
24 |
SS 4-40x.5 |
2 |
(2) |
|
23 |
SS 4-40x.38 |
4 |
(4) |
|
22 |
spring plunger |
4+2 |
(4+2) |
|
|
|
|
|
|
|
|
|
|
|
18 |
magnets, 1.9mm od, length 3.2 mm |
5 |
~30 not coated, rusty |
buy Ni coated ones for future use from www.electroenergy.com
|
17 |
guide rod, 0.635 mm od, 3.3 mm |
3 |
6 |
Al |
16 |
wire standoff, 1 mm od, 4.8 mm |
2 |
2 |
Al and ruby (ruby groove not centered) |
15 |
short OSEMs |
5 |
6 |
|
14 |
spare ETMX in 40m wiki |
1 |
1 |
confirmed in cabinet |
|
|
|
|
|
12 |
dumbbell standoff |
5 |
6 |
|
11 |
Al stiffening plate |
1 |
(1) |
|
10 |
wire clamp B in sus block |
2 |
(2) |
|
9 |
wire clamp A |
1 |
(1) |
|
8-7 |
lower clamp for lifting optics |
2 |
(2) |
|
6 |
upper clamp to hold down optic |
1 |
(1) |
|
5-4 |
left-right side of tower |
1 ea |
(1ea) |
|
3 |
tower base |
1 |
(1) |
|
2 |
sus block |
1 |
(1) |
|
1 |
lower and upper OSEM holders |
1ea |
(1ea) |
|
|
|
|
|
|
48 |
sandind fixture for magnet&dumbbell |
|
|
|
45 |
magnet-dumbbell assemblly fixture |
1 |
1 |
|
43 |
guide-wirestandoff gluing fixture |
1 |
1 |
Ok for larger RUBY,
unit is not in perfect condtition but usefull
|
|
|
|
|
|
|
First contact |
|
3-15-2013 purchase |
Pick up FC from Gary with purchasing date 7-7-2015
or later
|
|
FCPEEK peeler ring disk for TM cleaning |
10 front,10 back side |
have sheets only |
32&19mm ID punches ordered |
|
GordonBrush custom for LIGO optical cleaning |
~5 |
1 (3/8wide nylonSS) |
more from Calum available |
|
EP30-2 epoxy |
have |
have |
expiration date 9-24-2016 |
NOT finished, last edited 7-7 |
Attachment 1: SOSsus_Page_1.png
|
|
Attachment 2: SOSsus_Page_2.png
|
|
Attachment 3: ETMXspareTowerFace.jpg
|
|
Attachment 4: ETMXspareTowerBack.jpg
|
|
Attachment 5: magnets-dumbbells.jpg
|
|
12188
|
Thu Jun 16 11:25:00 2016 |
Johannes | Update | LSC | Y-Arm round-trip loss measurement with ALS |
Using the ALS green beat and armlength feedback I mapped an IR resonance of the Y-Arm by stepping through a ramp of offset values.
First I optimized the IR alignment with the dither scripts while LSC kept the arm on resonance, and then transitioned the length control to ALS. The beat frequency I obtained between the Y-arm green and the PSL was about 25 MHz. Then I applied a controlled ramp signal (stepping through small offset increments applied to LSC-ALSY_OFFSET, while logging the readback from channels LSC-TRY_OUT16 and ALS-Y_FC_SERVO_INMON with an averaging time of 1s.
The plots show the acquired data with fits to and , respectively.
 
The fits, weighted with inverse rms uncertainty of the data points as reported by the cds system, returned HWHM = 0.6663 ± 0.0013 [offset units] and m = -0.007666 ± 0.000023 [MHz/offset unit], which gives a combined FWHM = 10,215 ± 36 Hz. The error is based purely on the fit and does not reflect uncertainties in the calibration of the phase tracker.
This yields a finesse of 388.4 ± 1.4, corresponding to a total loss (including transmissivities) of 16178 ± 58 ppm. These uncertainties include the reported accuracies of FSR and phase tracker calibration from elog 9804 and elog 11761.
The resulting loss is a little lower than that of elog 11712, which was done before the phase tracker re-calibration. Need to check for consistency. |
Attachment 1: T_vs_steps.pdf
|
|
Attachment 2: f_vs_steps.pdf
|
|
12189
|
Thu Jun 16 12:06:59 2016 |
ericq | Update | LSC | RF Amp installed at POY11 RF output |
I have installed a ZFL-500LN on the RF output of POY11. This should reduce the effect of the CM board voltage offsets by increasing the size of the error signal coming into the board. Checking with an oscilloscope at the LSC rack, the single arm PDH peak to peak voltage was something like 4mV, now it is something like 80mV. 

The setup is similar to the REFL165 situation, but with the amplifier in proximity with the PD, instead of at the end of a long cable at the LSC rack.
The PD RF output is T'd between an 11MHz minicircuits bandpass filter and a 50 Ohm terminator (which makes sure that signals outside of the filter's passband don't get reflected back into the PD). The output of the filter is connected directly to the input of the ZFL-500LN, which is powered (temporarily) by picking off the +15V from the PD interface cable via Dsub15 breakout. (I say temporarily, as Koji is going to pick out some fancy pi-filter feedthrough which we can use to make a permanent power terminal on the PD housing.)
The max current draw of this amplifier is 60mA. Gazing at the LSC interface (D990543), I think the +15V on the DSUB cable is being passed from the eurocard crate; I don't see any 15V regulator, so maybe this is ok...
The free swinging PDH signal looked clean enough on a scope. Jamie is doing stuff with the framebuilder, so I can't look at spectra right now. However, turning the POY whitening gain down to +18dB from +45dB lets the Y arm lock on POY with all other settings nominal, which is about what we expect from the nominal +23dB gain of the amplifier.
I would see CM board offsets of ~5mV before, which was more a little more than a linewidth before this change. Now it will be 5% of that, and hopefully more manageable. |
12190
|
Thu Jun 16 15:57:46 2016 |
gautam | Update | COC | Contrast as a function of RoC of ETMX |
Summary
In a previous elog, I demonstrated that the RoC mismatch between ETMX and ETMY does not result in appreciable degradation in the mode overlap of the two arm modes. Koji suggested also checking the effect on the contrast defect. I'm attaching the results of this investigation (I've plotted the contrast, rather than the contrast defect 1-C).
Details and methodology
- I used the same .kat file that I had made for the current configuration of the 40m, except that I set the reflectivities of the PRM and the SRM to 0.
- Then, I traced the Y arm cavity mode back to the node at which the laser sits in my .kat file to determine what beam coming out of the laser would be 100% matched to the Y arm (code used to do this attached)
- I then set the beam coming out of the laser for the subsequent simulations to the value thus determined using the
gauss command in finesse.
- I then varied the RoC of ETMX (I varied the sagittal and tangential RoCs simultaneously) between 50m and 70m. As per the wiki page, the spare ETMs have an RoC between 54 and 55m, while the current ETMs have an RoC of 60.26m and 59.48m for the Y and X arms respectively (I quote the values in the "ATF" column). Simultaneously, at each value of the RoC of ETMX, I swept the microscopic position of the ETMX HR surface through 2pi radians (-180 degrees to 180 degrees) using the
phi functionalilty of finesse, while monitoring the power at the AS port of this configuration using a pd in finesse. This guarantees that I sweep through all the resonances. I then calculate the contrast using the above formula. I divided the parameter space into a grid of 50 points for the RoC of ETMX and 1000 points for the microscopic position of ETMX.
- I fixed the RoC of ETMY as 57.6m in the simulations... Also, the
maxtem option in the .kat file is set to 4 (i.e. higher order modes with indices m+n<=4 are accounted for...)
Result:
Attachment #1 shows the result of this scan (as mentioned earlier, I plot the contrast C and not the contrast defect 1-C, sorry for the wrong plot title but it takes ~30mins to run the simulation which is why I didn't want to do it agian). If the RoC of the spare ETMs is about 54m, the loss in contrast is about 0.5%. This is in good agreement with this technical note by Koji - it tells us to expect a contrast defect in the region of 0.5%-1% (depending on what parameter you use as the RoC of ETMY).
Conclusion:
It doesn't seem that switching out the current ETM with one of the spare ETMs will result in dramatic degradation of the contrast defect...
Misc notes:
- Regarding the
phase command in Finesse - EricQ pointed out that the default value of this is 3, which as per the manual could give unphysical results sometimes. The flags "0" or "2" are guaranteed to yield physical results always according to the manual, so it is best to set this flag appropriately for all future Finesse simulaitons.
- I quickly poked around inside the cabinet near the EX table labelled "clean optics" to see if I could locate the spare ETMs. In my (non-exhaustive) search, I could not find it in any of the boxes labelled "2010 upgrade" or something to that effect. I did however find empty boxes for ETMU05 and ETMU07 which are the ETMs currently in the IFO... Does anyone know if I should look elsewhere for these?
EDIT 17Jun2016: I have located ETMU06 and ETMU08, they are indeed in the cabinet at the X end...
- I'm attaching a zip file with all the code used to do this simulation. The phase flag has been appropriately set in the (only) .kat file. setLaserQparam.py was used to determine what beam parameter to assign to be perfectly matched to the Y arm. modeMatchCheck_ETM.py was used to generate the contrast as a function of the RoC of ETMX.
- With regards to the remaining checks to be done - I will post results of my investigations into the HOM scans as a function of the RoC of the ETMs and also the folding mirrors shortly...
|
Attachment 1: contrastDefect.pdf
|
|
Attachment 2: finesseCode.zip
|
12191
|
Thu Jun 16 16:11:11 2016 |
jamie | Update | CDS | upgrade aborted for now |
After poking at the new configuration more, it also started to show instability. I couldn't figure out how to make test points or excitations available in this configuration, and adding in the full set of test point channels, and trying to do simple things like plotting channels with dtt, the frame writer (fw) would fall over, apparetnly unable to keep up with the broadcast from the dc.
I've revered everything back to the old semi-working fb configuration, and will be kicking this to the CDS group to deal with. |
12192
|
Thu Jun 16 18:08:57 2016 |
Johannes | Update | PSL | Before the AOM installation |
There was only one razor blade beam dump labeled for atmospheric use left, but that's all we need. Steve is working on restocking. I placed the modified AOM mount on the PSL table near its intended location (near the AOM where it doesn't block any beams).
Things to keep in mind:
- The laser power needs to be turned down for the installation of the AOM. Current laser settings are: Crystal Temperature: 29.41 C, Diode Current: 2.1 A.
- The AOM driver must not be left unterminated when turned on (which it currently is and will be).
- The HEPA filters are currently running at ~50%. While the PSL enclosure is open for the work we'll set them to 100% and lower them after a job well done.
The setup:

The AOM has a deflection angle of about 20 mrad, which requires about 10cm of path for a separation of 2mm of the two beams. I need to survey closer and confirm, but I hope I can fit the beam dump in before the PMC (this of course also depends on the spot size). Alternatively, the PMC hopefully isn't resonant for anything remotely relevant at 80MHz offset, in which case we can also place the beam dump in its reflection path.
So this is the plan:
- Determine coupling efficiency into PMC for reference
- Turn down laser power
- No signal on AOM driver modulation input
- Mount AOM, place in beam path, and align
- Correct alignment into PMC?
- Secondary beam detectable? Adjust modulation input and laser power until detectable.
- Find a place for beam dump
- Confirm that primary beam is not clipping with PMC
- Turn up laser power
- Determine coupling efficiency with restored power to compare
Any thoughts? Based on the AOMs resting place I assumed that it is supposed to be installed before the PMC, but I'm actually not entirely sure where it was sitting before. |
12193
|
Thu Jun 16 18:42:12 2016 |
rana | Update | COC | Contrast as a function of RoC of ETMX |
That sounds weird. If the ETMY RoC is 60 m, why would you use 57.6 m in the simulation? According to the phase map web page, it really is 60.2 m. |
12194
|
Thu Jun 16 23:02:57 2016 |
gautam | Update | COC | Contrast as a function of RoC of ETMX |
Quote: |
That sounds weird. If the ETMY RoC is 60 m, why would you use 57.6 m in the simulation? According to the phase map web page, it really is 60.2 m.
|
This was an oversight on my part. I've updated the .kat file to have all the optics have the RoC as per the phase map page. I then re-did the tracing of the Y arm cavity mode to determine the appropriate beam parameters at the laser in the simulation, and repeated the sweep of RoC of ETMX while holding RoC of ETMY fixed at 60.2m. The revised contrast defect plot is attached (this time it is the contrast defect, and not the contrast, but since I was running the simulation again I thought I may as well change the plot).
As per this plot, if the ETMX RoC is ~54.8m (the closer of the two spares to 60.2m), the contrast defect is 0.9%, again in good agreement with what the note linked in the previous elog tells us to expect... |
Attachment 1: contrastDefect.pdf
|
|
12195
|
Fri Jun 17 15:22:31 2016 |
gautam | Update | VAC | N2 supply line restored after retiling |
Quote: |
The drill room floor will be retiled Thursday, June 16. Temporary nitrogen line set up will allow emptying the hole area.
Ifo room entry will be through control room.
|
The retiling work has finished, Steve and I restored the N2 supply configuration to its normal state. The sequence of steps followed was:
- Went to the X end and closed the following valves, roughly in this order: VAEE, VAEV, VABS, VABSCI, VASV, VASE, V4, V1.
- Checked the RPM on the various turbo pump controllers to make sure they were in their nominal states
- Disconnect the electrical connections to V1, V4, V5 and VA6 - just to make sure some spurious signal doesn't unintentionally open any of these valves while we are mucking around with the N2 supply
- Close the valves on the N2 cylinders in the drill room. Disconnect the temporary nitrogen line (at this point, the N2 pressure to the IFO valves goes down from ~7-PSI to 0), reconnect the old supply chain, taking care that we aren't unintentionally loosening any of the Swagelock connections while unscrewing stuff
- Replaced one of the N2 cylinders that was running low.
- Reopen the cylinders, restore N2 pressure to IFO valves to ~70PSI.
- Do steps 1-3 in reverse: i.e. reconnect power to all valves, open them in the reverse order we closed them while monitoring the state of the various turbo pumps.
- Acknowledged the error message on the C0VAC medm screen
Note: the valve isolating the RGA automatically shutoff during this work, possibly because it detected a pressure above its threshold - after checking the appropriate pressure gauges, we reopened this valve as well.
The attached screenshot suggests that everything went as planned and that the vacuum system is back to normal...
|
Attachment 1: c0vac_06172016.png
|
|
12196
|
Fri Jun 17 22:36:11 2016 |
Johannes | Update | PSL | AOM installation |
Subham and I have placed the AOM back into the setup right in front of the PMC.
Steps undertaken:
- The HEPA filters were turned off for some reason. They were turned back on, running at 100% while the enclosure was open.
- Before the installation, after initial realignment, the PMC TRANSPD read out 748 mV.
- The laser injection current was dialed down to 0.8 A (just above the threshold, judging by PMC cameras.
- AOM was attached to the new mount while staying connected to its driver. Put in place, a clamp prevents the cable from moving anywhere near the main beam.
- Aligned AOM to beam, centering the beam (by eye) on front and back apertures.
- We then applied an offset to the AOM driver input, eventually increasing it to 0.5 V. A secondary beam became clearly visible below the primary beam.
- In order to place the razor blade dump (stemming from a box, labeled "cleaned for atm use") before the PMC, where the beam separation was about 3 mm, to make sure we can hit the edged area, we had to place the dump at an angle, facing up.
- Keeping the 0.5V offset on the driver input, with the lights off, we increased the laser diode current in steps of ~200 mA to its original value of 2.1A, while checking for any IR light scattered from the beam dump. Not a trace.
- At original current setting, we realigned the beam into the PMC, and obtained 743 mV on the TRANSPD in the locked state.
- Closed off PSL table, dialed HEPAs down to 50%

|
Attachment 1: aom_new_mount.jpg
|
|
12197
|
Mon Jun 20 01:38:04 2016 |
rana | Update | COC | Contrast as a function of RoC of ETMX |
So, it seems that changing the ETMX for one of the spares will change the contrast defect from ~0.1% to 0.9%. True? Seems like that might be a big deal. |