ID |
Date |
Author |
Type |
Category |
Subject |
11199
|
Fri Apr 3 14:57:38 2015 |
manasa | Update | SUS | BS oplev |
The BS oplev has been misbehaving and kicking the optic from time to time since noon. The kicks are not strong enough to trip the watchdogs (current watchdog max counts for the sensors is 135).
I took a look at the spectrum of the BS oplev error in pit and yaw with both loops enabled while the optic was stable. There is nothing alarmingly big except for some additional noise above 4Hz.
I have turned the BS oplev servo OFF for now. |
Attachment 1: BS_oplev_Apr3.png
|
|
11200
|
Fri Apr 3 15:15:55 2015 |
Steve | Update | SUS | BS oplev |
I saw this kicking before
Quote: |
The BS oplev has been misbehaving and kicking the optic from time to time since noon. The kicks are not strong enough to trip the watchdogs (current watchdog max counts for the sensors is 135).
I took a look at the spectrum of the BS oplev error in pit and yaw with both loops enabled while the optic was stable. There is nothing alarmingly big except for some additional noise above 4Hz.
I have turned the BS oplev servo OFF for now.
|
|
11201
|
Fri Apr 3 19:35:14 2015 |
Jenne | Update | SUS | BS oplev centered |
I think that this happens when the beam gets too close to the edge of the QPD. We see this regularly in the ETMs, if they've been kicked a bit, but not enough to trip the watchdogs. I think it might be the step/impulse response of the RES3.3 filter, which rings for almost 20 seconds.
Anyhow, I've just recentered the BS oplev. It was at -21urad in pitch, and had more than 400 counts on the top two quadrants, but only about 100 counts on the bottom two. Now it's around 300 counts on all 4 quadrants.
As a totally unrelated aside, I have installed texlive on Donatella, so that I could run pdflatex. |
11227
|
Mon Apr 20 16:42:48 2015 |
steve | Update | SUS | PRM and BS oplev laser replaced |
The laser below is dead. JDSU 1103P, SN P845655 lived for 3.5 years.
Quote: |
JDSU 1103P died after 4 years of service. It was replaced with new identical head of 2.9 mW output. The power supply was also changed.
The return spots of 0.04 mW 2.5 mm diameter on qpds are BS 3,700 counts and PRM 4,250 counts.
|
It was replaced by JDSU P/N 22037130,( It has a new name for 1103P Uniphase ) sn P919639 of mfg date 12-2014
Beam shape at 5 m nicely round. Output power 2.8 mW of 633 nm
BS spot size on qpd ~1 mm & 60 micro W
PRM spot size on qpd ~1 mm & 50 micro W |
Attachment 1: newOplevLaser.png
|
|
11234
|
Wed Apr 22 11:43:28 2015 |
Steve | Update | SUS | ETMX damping restored |
ETMX sus damping restored. |
11246
|
Fri Apr 24 23:40:15 2015 |
rana | Update | SUS | PRM and BS oplev laser replaced |
Recently, Steve replaced the HeNe which was sourcing the BS & PRM OL. After replacement, no one checked the beam sizes and we've been living with a mostly broken BS OL. The beam spot on the QPD was so tiny that we were seeing the 'beam is nearly the size of the segment gap' effect.
Today I removed 2 of the lenses which were in the beam path: one removed from the common PRM/BS path, and one removed from the PRM path. The beams on both the BS & PRM got bigger. The BS beam is bigger by a factor of 7. I've increased the loop gains by a factor of 6 and now the UGFs are ~6 Hz. The loop gains were much too high with the small beam spots that Steve had left there. I would prefer for the beams to be ~1.5-2x smaller than they are now, but its not terrible.
Many of the mounts on the table are low quality and not constructed stably. One of the PRM turning mirror mounts twisted all the way around when I tried to align it. This table needs some help this summer.
In the future: never try locking after an OL laser change. Always redo the telescope and alignment and check the servo shape before the OL job is done.
Also, I reduced the height of the RG3.3 in the OL loops from 30 to 18 dB. The BS OL loops were conditionally stable before and thats a no-no. It makes it oscillate if it saturates.
|
Attachment 1: BSOL.pdf
|
|
11256
|
Sun Apr 26 15:34:34 2015 |
Jenne | Update | SUS | PRM oplev centered |
After last week's work on the BS/PRM oplev table, I think the PRM oplev got centered while the PRM was misaligned. With the PRM aligned, the oplev spot was not on the QPD. It has been centered. |
11319
|
Fri May 22 11:59:54 2015 |
ericq | Update | SUS | DampRestore script problem |
PRM watchdog tripped, but the damprestore.py script wouldn't run.
It turns out the script tries to import some ezca stuff from /users/yuta ( ), which had been moved to /users/OLD/yuta ( ).
I've moved the yuta directory back to /users/ until I fix the damprestore script. |
11320
|
Fri May 22 12:09:57 2015 |
rana | Update | SUS | DampRestore script problem |
I will move it back. We need to fix our scripts to not use any users/ libraries ever again.
Quote: |
PRM watchdog tripped, but the damprestore.py script wouldn't run.
It turns out the script tries to import some ezca stuff from /users/yuta ( ), which had been moved to /users/OLD/yuta ( ).
I've moved the yuta directory back to /users/ until I fix the damprestore script.
|
|
11339
|
Mon Jun 1 08:32:14 2015 |
Steve | Update | SUS | PRM damping restored |
Local earthquake 3.8 Mag tripped only PRM
Vac monitor is not communicating.
PSL HEPA turned on
|
Attachment 1: indio3.8Meq.png
|
|
11349
|
Tue Jun 9 10:57:12 2015 |
Steve | Update | SUS | BS oplev laser tuned |
Lenses removed from oplev beam path at elog entry 11246
|
Attachment 1: 100dBStrend0425.png
|
|
Attachment 2: 18dBSdrift.png
|
|
11476
|
Mon Aug 3 08:16:19 2015 |
Steve | Update | SUS | ETMX damping restored |
|
Attachment 1: ETMXrestored.png
|
|
11525
|
Mon Aug 24 14:05:47 2015 |
ericq | Update | SUS | EricG Investigating L2A |
This afternoon, I showed Eric Gustafson some of the basics of making swept sine measurements with DTT. We turned off the f2a filters and oplev damping on the BS and made a cursory measurement of the transfer function from position drive to the oplev signals.
He will be in the lab periodically to continue this line of investigations. |
11526
|
Mon Aug 24 16:10:07 2015 |
ericq | Update | SUS | ETMY Oplev laser power is falling |
Today I noticed the box around the ETMY oplev sum flashing red, as it dipped below 1k. I don't recall seeing this recently, so I wanted to look up the history.
However, we've been having trouble with our minute (and longer) trend data, so I had to hack it out a bit... Here is the unfortunate result:

I think we can be fairly confident that this is not due to alignment drifts, we generally keep the QPD reasonably well centered. I also recentered it today, and the counts remained at ~1k.
Details of the hack that got me this data:
I ended up looking at the BURT snapshots from every night at midnight, which report a number for ETMY_OL_SUM_OUT16, and making a text file with dates and values with the following BASH spaghetti:
find /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2015 -wholename "*00*/*scy*" |xargs ack --nogroup "ETMY_OL_SUM_OUT16 1" | sed -e 's/.*2015/2015/g' -e 's/\/c1.*\([0-9]\..*$\)/, \1/g' -e 's/\//-/g' > ETMYsum.txt
This produces a file full of unsorted lines like: 2015-Aug-23-00:07, 1.106459228515625e+03
The python package pandas is good at parsing dates and automatically plotting time series:
olsum = pandas.read_csv('ETMYsum.txt', index_col=0, parse_dates=True)
olsum.plot()
|
Attachment 1: ETMYsum_trend.pdf
|
|
11527
|
Mon Aug 24 16:46:49 2015 |
ericq | Update | SUS | ETMY Oplev laser power is falling |
Repeated for all optics, ETMY seems like the only one sharply dropping for now (PRM is all over the place and hard to gauge, since we often leave it partially- or mis-aligned):

Hacky bits:
Bash:
find /opt/rtcds/caltech/c1/burt/autoburt/snapshots/2015 -wholename "*00:0*"
| xargs ack --nogroup "OL_SUM_OUT16 1"
| grep -v 'SUS-MC'
| sed -e 's/.*2015/2015/g' -e 's/\/c1.*C1:SUS-/, /g' -e 's/_OL.*\([0-9]\..*$\)/, \1/g' -e 's/\//-/g'
| sort | uniq > allOL.txt
qontrols@pianosa|~ > head allOL.txt
2015-Apr-10-00:07, BS, 1.146766113281250e+03
2015-Apr-10-00:07, ETMX, 1.597261328125000e+04
2015-Apr-10-00:07, ETMY, 4.331762207031250e+03
2015-Apr-10-00:07, ITMX, 6.488521484375000e+03
2015-Apr-10-00:07, ITMY, 1.387590234375000e+04
2015-Apr-10-00:07, PRM, 8.352053833007812e+02
2015-Apr-10-00:07, SRM, 6.099560928344727e+01
2015-Apr-1-00:07, BS, 1.180478149414062e+03
2015-Apr-1-00:07, ETMX, 1.584842480468750e+04
Python:
olsum = pd.read_csv('allOL.txt',parse_dates=True, names=['Date','Optic','Sum'])
olsum['Date'] = pd.to_datetime(olsum['Date']) # Automatic parsing didn't work for some reason
olpivot = olsum.pivot(index='Date',columns='Optic',values='Sum')
olpivot.plot()
|
Attachment 1: OLsum_trend.pdf
|
|
11566
|
Thu Sep 3 08:53:55 2015 |
Steve | Update | SUS | ETMY Oplev laser power is falling |
Rana, Steve
We investigated the ETMY oplev table set up and did not find a red herring.
Two 2 years vs one day plot below.
ps: thanks Q for fixing DTT, the auto scaling is not working at sampling rate 10 min and 1 hr period?? 
|
Attachment 1: ETMYoplev2y.png
|
|
11569
|
Thu Sep 3 19:52:24 2015 |
rana | Summary | SUS | SUS drift monitor |
Since Andrey's SUS Drift mon screen back in 2007, we've had several versions which used different schemes and programming languages. Diego made an update back in January.
Today I added his stuff to the SVN since it was lost in the NFS disks somewhere. Its in SUS/DRIFT_MON/.
Since we've been updating our userapps directory recently to pull in the screens and scripts from the sites, we also got a copy of the Thomas Abbott drift mon stuff which is better (Diego actually removed the yellow/red functionality as part of the 'upgrade'), but more complicated. For now we have the old one. I updated the good values with all optics roughly aligned just a few minutes ago.
|
Attachment 1: 07.png
|
|
11642
|
Fri Sep 25 11:08:33 2015 |
Steve | Update | SUS | wire standoffs |
Our last effort to change the existing Al-6061 wire standoffs was at April 2012
We requested sapphire and/or ruby materials with smaller R at the bottom of the groove. Groove polishing was asked for.
Insaco Inc. quote 84740 as " best effort " NO POLISHING. The groove cut to be with eximer laser.
Jeff Lewis as 9-12-2012: the LIGO sapphire prisms grooves were NOT POLISHED but Resonatics used the corner of a rasor blade to scrape off the
ablated material wich was redeposited in and around the grooves.
|
Attachment 1: wireStandOff_SOS.PDF
|
|
11643
|
Fri Sep 25 14:52:08 2015 |
Steve | Update | SUS | ETMX is not drifting |
We have talked about the drift of ETMX sus on the Wednesday meeting.
It has stopped moving on Jan 8, 2015 and it has been reasanable stable since than.
|
Attachment 1: ETMXstoppedDrifting.png
|
|
Attachment 2: 25daysArmsT.png
|
|
11646
|
Fri Sep 25 19:06:13 2015 |
rana | Update | SUS | ETMX IS drifting |
I don't see any evidence of it getting more stable. It seems there was a big step in January, but the problem we were talking about - the suspension shifting when it gets a big kick - can't be proven to be gone or not by just looking at the trends. The real issue is whether or not it slips when we put in a large step in the LSC.
Quote: |
We have talked about the drift of ETMX sus on the Wednesday meeting.
It has stopped moving on Jan 8, 2015 and it has been reasanable stable since than.
|
|
11667
|
Mon Oct 5 11:25:21 2015 |
ericq | Update | SUS | ETMY OL laser dead |
Gautam alerted me that the Y arm looked like it was being dithered, even though the ASS was turned off. I found that the ETMY OL signals were garbage, leading to the servos flipping back and forth between their rails.
We went out to the ETMY table, and found the HeNe laser to be emitting a paltry <0.5mW; the OL QPD could not register the puny beam incident on it.
Here is the last 30 days of OL_SUM:

Steve will replace the laser this afternoon. |
11668
|
Mon Oct 5 16:41:22 2015 |
Steve | Update | SUS | ETMY OL laser replaced |
This JDSU 1103P laser, sn P892324 lived for 2 years. It's power output is 0.05 mW now
It was replaced with brand new JDSU 1103P, sn P919645, Mfg date 12/2014 with 2.75 mW output.
There is 0.14 mW light returning to the qpd = 7,250 counts without AR 632 lenses |
11702
|
Tue Oct 20 15:51:44 2015 |
ericq | Update | SUS | MC2 F2P tuned |
Using a modified version of Hang's deMod_deCoup scripts, I tuned the MC2 coil output matrix to minimize the appearance of POS drive in the SUSPIT signal at 28Hz. Up until now, there was no F2P compensation. This reduced the force to pitch coupling at 28Hz by 8dB. 
Old: POS -> 1 x UL, 1 x UR, 1 x LL, 1x LR
New: POS -> 1.1054 x UL, 1.1054 x UR, 0.8946 x LL, 0.8946 LR
I checked the MCL spectrum before and after this change with OAF on, this did not spoil the feedforward length subtraction in any noticible way.
The script lives in userapps/release/isc/c1/scripts/decoup , but I've symlinked it to /opt/rtcds/caltech/c1/scripts/decoup .
The script modification I made had to do with how the I and Q data is collected. Before, it was sporadically probing the I and Q FM output monitor EPICS values; I changed it to use the avg function of cdsutils, which calculates the mean and std from the 16kHz data and have seen it improve results by 1dB or so. I've been in touch with Jenne to propagate this to the sites. |
11711
|
Fri Oct 23 21:58:10 2015 |
rana | Update | SUS | MC2 F2P mis-tuned |
The OSEMs cannot be used for coil balancing above ~10 Hz. The main coupling path from OSEM drive to sensor is not through the mirror motion, but instead direct electrical coupling of the drive wires to the sensing wires.
I put this in the elog every ~1-2 years since people keep trying it, but it keeps coming back like a zombie.
Better to use the MC angular sensors for L2A decoupling. Not perfect, but better than OSEMs. For the TMs we can use the OLs. |
11716
|
Tue Oct 27 03:46:26 2015 |
ericq | Update | SUS | MC2 F2P mis-tuned |
D'oh. Good point.
Reverted for now; I'm thinking about doing laser pointer->MC2 QPD... |
11724
|
Fri Oct 30 17:49:27 2015 |
Steve | Update | SUS | ETMX kicked up |
The oplev and the LSC are off. |
Attachment 1: ETMXkicking.png
|
|
Attachment 2: ETMXkickedbyOpPerror.png
|
|
Attachment 3: ETMXstillKicking.png
|
|
Attachment 4: ETMXkickingCond.png
|
|
Attachment 5: 7hrsETMX-Y.png
|
|
11727
|
Tue Nov 3 18:49:41 2015 |
gautam | Update | SUS | ETMX kicked up |
I was trying to take a few more IR transmission scans with ALS when the ETMX got kicked again. I'm not sure how to fix this, so for the time being, I'm leaving the Oplev servo and the LSC turned off. The oplev spot looks really far off center especially in yaw, the yaw error is ~ -80.
Quote: |
The oplev and the LSC are off.
|
|
11729
|
Wed Nov 4 14:44:00 2015 |
ericq | Update | SUS | ETMX oplev servo disabled |
I've turned the ETMX oplev servos off for the time being. (At the input side, so that no scripts will accidently turn it on).
Thus, only the local damping is being applied, let's see if we see any kicks... |
11733
|
Wed Nov 4 22:42:02 2015 |
ericq | Update | SUS | ETMX oplev servo disabled |
During this time period, it looks like there was maybe one excursion. Here are the individual OSEM signals, which I think to be calibrated to microns.

When I'm doing other things, I'm going to intentionally leave the watchdog tripped, and see if anything happens. |
11744
|
Mon Nov 9 23:22:18 2015 |
ericq | Update | SUS | ETMX oplev servo disabled |
During a ETMX kick that just occured, with only local damping on, the slow VMon channels didn't show any noticable change.

|
11752
|
Wed Nov 11 14:06:09 2015 |
rana | Update | SUS | ETMX oplev servo disabled |
How many volts does it take to pitch the ETM by 5 urad? |
11753
|
Wed Nov 11 22:11:15 2015 |
Koji | Update | SUS | PSL/IOO maintenance, TM SUS check up |
PMC
- Before any of the following work, I went to the PSL table and aligned the PMC. In fact, it has not been misaligned.
IMC
- It was claimed in the meeting today that the IMC had not been happy thesedays. I checked out what's happening.
- I found the IMC was still well aligned. Autolocker frequently stuck on a weak higher-order mode and couldn't recover TEM00 locking without help.
- I modified /opt/rtcds/caltech/c1/scripts/MC/mcdown for easier relocking on TEM00.
The MC_REFL_GAIN and MC_VCO_GAIN for relocking was set to be 27 and -3, in stead of 0 and 10, respectively.
This means that REFL_GAIN is not changed before and after the locking. Only VCO_GAIN is lowered for lock acquisition.
The corresponding lines in mcdown are excerpted here.
#set servo and boost gains for re-acquisition
#${ewrite} C1:IOO-MC_REFL_GAIN 0 &
${ewrite} C1:IOO-MC_REFL_GAIN 27 &
#${ewrite} C1:IOO-MC_VCO_GAIN 10 &
${ewrite} C1:IOO-MC_VCO_GAIN -3 &
We still have some chance of locking on higher-order modes. If I jiggle the VCO gain slider from -31 to 0, eventually I find TEM00.
I don't know how to do it in the script yet. For now, I increased tickle amplitude from 300 to 500.
/opt/rtcds/caltech/c1/scripts/MC/MC2tickleON
amp=300
=>
amp=500
- IMC was locked and aligned with the WFS. The WFS feedback offsets were offloaded to the alignment slider (via the MEDM button as usual).
TM SUS
- I wanted to use ASS. => The OL damping and ASC inputs are enabled for ETMX. The filter bank output of the ASS servos are all turned on.
- The arms were locked and aligned with ASS. The ASS servo offsets were offloaded to the ASC offset sliders (as usual).
- I found the X arm spot positionis moving slowly in pitch. I wanted to know what is causing this.
- Turned off all the OPLEV dampings for the four test masses.
- Took the power spectra of the OSEM output (e.g. C1:SUS-ITMX_LLSEN_OUT)
See attachment 1 (The DTT XML file can be found as /users/koji/151111/TM_SUS.xml )
- It seems that something is wrong with ITMX UL OSEM
The signal level seems to be identical with the others. However, the noise level is huge. We need to check if the cable connection is OK.
- ITMY LL shows remarkably higher bounce mode although I can't tell if this is normal or not.
- The OPLEV dampings have been restored. |
Attachment 1: TM_SUS.pdf
|
|
Attachment 2: TM_SUS_SD.pdf
|
|
11755
|
Thu Nov 12 09:15:56 2015 |
Steve | Update | SUS | ITMX osems |
The ITMX OSEMS are oscillating. |
Attachment 1: ITMX.png
|
|
11758
|
Thu Nov 12 10:47:17 2015 |
ericq | Update | SUS | ETMX oplev servo disabled |
By looking at the oplev and Vmons before and after a step of 90 counts in SUS-ETMX_PIT_OFFSET, I observe:
UL: +1.53mV / urad
UR: -1.94mV / urad
LR: -1.54mV / urad
LL: +1.92mv / urad
The random error associated with these measurements is ~0.02mV
So, the ~7urad urad shift seen in my earlier post would mean a change of around 10mV in the Vmon signals, which isn't evident in the traces. So, this is possibly a piece of evidence in favor of a real mechanical shift, rather than an electronic glitch. |
11760
|
Fri Nov 13 15:20:24 2015 |
Steve | Update | SUS | OSEMs |
Are they oscillating or not ?
Quote: |
The ITMX OSEMS are oscillating.
|
ETMX, ETMY and MC2 POS _biases are off. Why ?
The Epics MEDMs screens are going blank in ~3-5 minutes reluctantly. |
Attachment 1: OSEMs.png
|
|
Attachment 2: POSbiasOFF.png
|
|
11770
|
Tue Nov 17 00:57:21 2015 |
ericq | Update | SUS | ITMX UL calmed? |
After running dither alignment for all mirrors, all oplevs were recentered. (Except ETMY, since we did that earlier today.)
Looking at Koji's template for OSEM signals, the ITMX UL sensor noise floor seems more in line with the LL sensor, though there continues to be more noise than in other mirrors.

Trending the sensor signals over the past 7 days, Koji's measurement looks to have been taken during a time when the UL sensor voltage had jumped down. Did someone squish the satellite box cable? I have not done so.

I think that the step right at the end is due to a new POS offset of -2k counts, which I think Koji put into place earlier today.
According to the wiki, the Vmax/2 values and the current values are:
Sensor
|
Vmax/2
|
Vnow
|
UL
|
0.985
|
0.75
|
UR
|
0.855
|
0.865
|
LR
|
0.735
|
0.938
|
LL
|
0.775
|
0.60
|
SD
|
0.835
|
1.16
|
|
Attachment 1: TM_nov17.pdf
|
|
11774
|
Tue Nov 17 15:59:23 2015 |
rana | Update | SUS | ITMX UL calmed? |
Although this noise is bad, we have always had these kind of humps around the bounce mode. Our interpretation in the past was that this was due to poor alignment of the OSEM in the frame, leading to a large vertical to horizontal coupling. Once you implement the BLRMS for the SUS channels, we'll be able to trend the noise over long periods of time. |
11792
|
Fri Nov 20 09:45:39 2015 |
steve | Summary | SUS | oplev laser summary |
Quote: |
Quote: |
May 13, 2014 ETMX, .............laser in place 90 d
May 22, 2012 ETMY,
Oct. 7, 2013 ETMY, LT 503 d or 1.4 y............bad beam quality ?
Aug. 8, 2014 ETMY, .............laser in place 425 days or 1.2 y
|
Sept. 5, 2014 new 1103P, sn P893516 installed at SP table for aLIGO oplev use qualification
|
|
Attachment 1: oplev_summery.png
|
|
11878
|
Mon Dec 14 14:08:49 2015 |
Steve | Update | SUS | Ruby wire standoffs update |
Two companies are willing to make the ruby grooves and the third one is still working on their quote.
The price is ~$100 each. The cost goes down 10% if we order 50 instead of 30 pieces.
How many should we get ? |
11903
|
Mon Dec 28 14:12:23 2015 |
Steve | Update | SUS | 4.2M EQ |
Suspensions are recovered after 4.2 Mag earth quake. No obvoius sign of damage.
|
Attachment 1: 4.2Meq.png
|
|
Attachment 2: recovered4.2M.png
|
|
11904
|
Wed Dec 30 11:09:52 2015 |
Steve | Update | SUS | 4.4M EQ |
Suspensions recovered after 4.4 Mag EQ
|
Attachment 1: 4.4MeqDevore.png
|
|
Attachment 2: free.png
|
|
11927
|
Tue Jan 12 07:54:23 2016 |
Steve | Update | SUS | ETMX damping restored |
PMC locked and ETMX suspension damping restored. |
11932
|
Thu Jan 14 13:44:05 2016 |
Steve | Update | SUS | earthquake 3.6M |
No obvious sign of damage.
|
Attachment 1: 3.6M_JohannesburgCA.png
|
|
Attachment 2: ETMX_3.6_M.png
|
|
11935
|
Tue Jan 19 10:25:53 2016 |
Steve | Update | SUS | EQ 3.6M Ludlow |
Just an other local earthquake 3.6 Mag Ludlow, Ca
No obvious sign of damage
|
Attachment 1: EQ_3.6M_Ludlow.png
|
|
11939
|
Wed Jan 20 09:36:11 2016 |
Steve | Update | SUS | ETMX damping restored |
ETMX suspension damping restored.
|
Attachment 1: EQ.png
|
|
11948
|
Mon Jan 25 08:36:46 2016 |
Steve | Update | SUS | PRM damping restored |
PRM suspension damping restored after 4.1 Mag Ludlow earthquake.
|
Attachment 1: EQ4.1mLudlow.png
|
|
Attachment 2: EQ7.1mAlaska_4.1mLudlow.png
|
|
Attachment 3: 7.1_4.1.png
|
|
11975
|
Thu Feb 4 10:14:52 2016 |
Steve | Update | SUS | earthquake 3.5M |
|
Attachment 1: EQ3.5m_Simmier.Ca.png
|
|
11980
|
Mon Feb 8 09:37:07 2016 |
Steve | Update | SUS | EQ 3.9m |
No sign of damage
|
Attachment 1: EQ3.9mSimmierCa.png
|
|
12001
|
Mon Feb 22 08:45:46 2016 |
Steve | Update | SUS | EQ 4.3 grabs ITMX-UL magnet |
Local EQ4.3
kicks ITMX-UL magnet into stuck position.
Hopefully it is only sticking. |
Attachment 1: EQ4.3LucerneV.png
|
|
Attachment 2: ITMX-UL.png
|
|
12003
|
Mon Feb 22 23:00:21 2016 |
ericq | Update | SUS | ITMX free, green is flashing |
Taking inspiration from J. Lewis et. al, ITMX has been freed.
Even better, I'm now seeing Green flashes in the X arm.  |