Eve | Update | General | Gaussianity tests |
I’m working on a code to determine the Gaussianity of a PSD.
Motivation:
It can be difficult to distinguish between GW events and non-Gaussian noise, especially in burst searches. By characterizing noise Gaussianity, we can better recognize noise patterns and distinguish between GW events and noise.
What I did:
I analyzed an hour of S5 L1 data. First, I plotted a timeseries, just to see what I was working with. Then, I produced a PSD (technically, an ASD) for the timeseries using Welch’s method in Python.
I split the data segment into smaller time-chunks and then produced a PSD for each chunk. All PSDs were superimposed in one plot. Here’s a plot for 201 time-chunks of equal length:

For a specific frequency, I can view the spread in PSD value through the production of a histogram.
Results:
I’ve made histograms displaying varying PSD values for the 201 PSD plot at 100 Hz, 500 Hz, and 1kHz.



For Gaussian noise, an exponential decay plot is expected. I will continue this analysis by following the statistical method in Ando et al. 2003 to calculate specific values indicative of the Gaussianity of various distributions. I’ll then look at different periods of time in the S5 L1 data to find periods of time suggesting non-Gaussian behavior. |
11493
|
Tue Aug 11 11:56:36 2015 |
Ignacio, Jessica | Update | PEM | Wasps obliterated maybe... |
The wasp terminator came in today. He obliterated the known wasp nest.

We discovered a second wasp nest, right next to the previous one...

Jessica wasn't too happy the wasps weren't gone!

|
11492
|
Tue Aug 11 11:30:19 2015 |
Ignacio | Update | IOO | SISO (T240-X) FF of MCL |
Last night we finally got some online subtraction going. The filter used is described in the post this eLOG is @eLOG 11488.
The results were as follow:
The filter worked as expected when subtracting noise out of MCL,

There is about a factor of 6 subtraction at the ~3Hz resonant peak. The static IIR filter predicted a factor of 6-7 subtraction of this peak as well.
The 1.2 Hz resenonant feature improved by a factor of 3. This should improve quite drastically when I implement the y-channel of the T240 seismo.
There is some high frequency noise being injected, not very noticeable, but present.
We then took a look at the power in the MC when the filter was on,

The power being transmitted in the cavity was not as stable as with the feedforward on. We believe that the filter is not at fault for this as Eric mentioned to me that the MC2 actuator lacked some sort of compensation that I need to understand a bit better.
YARM was then locked when the filter was on and we took a look at how it was doing. There was stationary sound arising from the locking of the YARM, leading us to believe that the filter might have injected some noise in the signal. IT DID.

The filter injected nasty high frequency noise at YARM from 11 Hz and on. This is to be expected since the filter did not roll off to zero at high frequencies. Implementing a 1/f rolloff should mitigate some of the injected noise.
Also, as one can see above, subtraction by around a factor of 2 or so, was induced by the mode cleaner feedforward subtraction. |
Attachment 1: MCL.png
|
|
Attachment 2: MCTRANS.png
|
|
Attachment 3: YARM.png
|
|
11491
|
Tue Aug 11 10:13:32 2015 |
Jessica | Update | General | Conductive SMAs seem to work best |
After testing both the Conductive and Isolated front panels on the ALS delay line box using the actual beatbox and comparing this to the previous setup, I found that the conductive SMAs improved crosstalk the most. Also, as the old cables were 30m and the new ones are 50m, Eric gave me a conversion factor to apply to the new cables to normalize the comparison.
I used an amplitude of 1.41 Vpp and drove the following frequencies through each cable:
X: 30.019 MHz Y: 30.019203 MHz
which gave a difference of 203 Hz.
In the first figure, it can be seen that, for the old setup with the 30m cables, in both cables there is a spike at 203 Hz with an amplitude of above 4 m/s^2/sqrt(Hz). When the 50m cables were measured in the box with the conductive front panel, the amplitude drops at 203 Hz by a factor of around 3. I also compared the isolated front panel with the old setup, and found that the isolated front panel worse by a factor of just over 2 than the old setup. Therefore, I think that using the conductive front panel for the ALS Delay Line box will reduce noise and crosstalk between the cables the most. |
Attachment 1: best4.png
|
|
Attachment 2: isolated4.png
|
|
11490
|
Tue Aug 11 02:40:29 2015 |
ericq | Update | LSC | 50m delay lines - Rough calibrations |
Jessica will soon ELOG about some measurements suggesting that the conductive connector-ized ALS delay line enclosure is the way to go, when considering crosstalk between the delay lines. It is currently mounted and hooked up on the LSC rack, though I need to make a bunch of new SMA cables now that I think a semi-permanent arrangement has been reached.
I did a rough re-calibration of the phase tracker output, since the increased cable delay changes the degree/Hz gain. This was done by fitting a line to a slow sawtooth FM of the SRS DS345's (1Hz rate, 10kHz deviation, 30MHz carrier). This resulted in the following calibration updates
-
ALSX: 19230 -> 13051 Hz/count, 3.4dB more sensitive
-
ALSY: 19425 -> 12585 Hz/count, 3.8db more sensitive
Again, this is a rough calibration. Nevertheless, it is not so surprising we don't get the 50m/30m = 4.4dB increase we would expect just from the lengths; the (I presume) increased cable loss matters. Also, the loss' frequency dependance is an additional reason that the phase tracker calibration is not constant over all frequencies.
I took spectra with the arms in IR lock, but didn't see any real improvement beyond a possible dip in the floor from 100-200Hz. This doesn't surprise me too much, however, since I don't believe that we are currently dominated by electronic noises that this gain increase would help overcome.
Last week, Koji mentioned the ALS phase noise added due to the post-cavity table motion the arm-transmitted green beams experience before hitting the beat PD. I should estimate the size of this effect for our situation. |
11489
|
Tue Aug 11 02:26:46 2015 |
ericq | Update | ASC | PRC Angular FF Lives! |
PRC Angular FF is back in action!
Short and sweet of it:
- Took witness (T240 channels) and target (POP QPD) with DC coupled oplevs on. About 25 minutes of nice stationary data.
- Downsampled everything to 32Hz, since coherence suggests subtraction only really possible from 1-5Hz.
- Prefiltering done by detrending and
ellip(3,3,40,5Hz)
- 4 second FIR impulse time was enough
- Filtered target by inverse actuator TF before sending to wiener code. The only difference between this and filtering the witnesses with the actuator TF directly is an effective RMS cost function, i.e. prefiltering.
- Spending time tweaking IIR fitting pays off. Divided out zpk(0, [p3, p3*],1), where p3 is some well fit stack/suspension resonance, so that vectfit fits remaining portion with equal numbers of poles and zeros, guaranteeing AC coupling and 1/f rolloff to prevent noise injection
- Quack->foton->OAF all worked fine
-
All in all, seems to work well. POPDC RMS goes down by a factor of 2 
- Code used lives in /users/ericq/2015-08-PRCFF and the NoiseCancellation github repo
Fit example:

Subtraction spectra

Subtraction prediction vs. reality (positive dB is good)
 
|
Attachment 1: fitExample.png
|
|
Attachment 2: FFspectra.png
|
|
Attachment 3: PITsub.png
|
|
Attachment 4: YAWsub.png
|
|
11488
|
Mon Aug 10 22:18:19 2015 |
Ignacio | Update | IOO | Ready to do some online mode cleaner subtraction |
I'm attaching a SISO IIR Wiener filter here for reference purposes that will go online either tonight or tomorrow evening. This is a first test to convince myself that I can get this to work, MISO IIR filters are close to being ready and will soon be employed.
This Wiener filter uses the STS-X channel as a witness and MCL as target. The bode plot for the filter is shown below,

The performance of the FIR and IIR Wiener filters and the ammount of subtraction achive for MCL is shown below,

Output from quack to be loaded with foton: filter.zip
K bye. |
Attachment 1: stsx.png
|
|
Attachment 2: performance.png
|
|
Attachment 3: filter.zip
|
11487
|
Mon Aug 10 15:25:05 2015 |
Steve | Update | PEM | wasp nest |
The wasp nest will be removed tomorrow from from the out side of the east arm window.
The resonant frequency of the newly arrived gravity bee detector is not known.
|
Attachment 1: waspN.jpg
|
|
11486
|
Mon Aug 10 11:57:45 2015 |
ericq | Update | General | IMC work |
Quote: |
Often when I come to manually lock the mode cleaner due to a long unlocked period, I find that the sliders are not in the state specified by the mcdown script. Furthermore, it's not the same channels every time; sometimes the servo gain is left high, sometimes the boosts are left on. I fear that some of the caput commands are failing to execute. Ugh.
|
This continues to happen. I believe the network latency boogeyman is to blame.
There was a long unlocked period because the enable switch for the MC servo fast path (FASTSW) was left off. Running the mcdown script fixed this, but included the error message:
Channel connect timed out: 'C1:IOO-MC_REFL_GAIN' not found.
CA Client Library: Ignored duplicate create channel response from CA server?
which means the IN1 gain didn't get touched. A second pass of the script produced no errors.
I'm thinking of adding some logic that if the autolocker has failed to lock for some period (5 minutes?), it should rerun mcdown. |
11485
|
Thu Aug 6 21:03:45 2015 |
Ignacio | HowTo | WienerFiltering | How to do online static IIR Wiener filtering |
In order to do online static IIR Wiener filtering one needs to do the following,
1) Get data for FIR Wiener filter witnesses and target.
2) Measure the transfer function (needs to be highly coherent, ~ 0.95 for all points) from the actuactor to the control signal of interest (ie. from MC2_OUT to MC_L).
3) Invert the actuator transfer function.
4) Use Vectfit or (LISO) to find a ZPK model for the actuator transfer and inverse transfer functions.
5) Prefilter your witness data with the actuator transfer function, to take into account the actuator to control transfer function when designing the offline Wiener FIR filter.
6) Calculate the frequency response for each witness from the FIR coefficients.
7) Vectfit the frequency reponses to a ZPK model, this is the FIR to IIR Wiener conversion step.
8) Now, either, divide the IIR transfer function by the actuator transfer function or more preferably, multiply by the inverse transfer function.
9) Use Quack to make SOS model of the IIR Wiener filter and inverse transfer function product that goes into foton for online implementation.
10) Load it into the system.
The block diagram below summarizes the steps above.

|
Attachment 1: iir.png
|
|
11484
|
Thu Aug 6 11:45:01 2015 |
Jessica | Update | General | ALS Delay Line front panel testing |
Koji had suggested that I sync up the two function generators to ensure that they have the same base frequency and so that crosstalk will actually appear at the expected frequency. After syncing up the two function generators, I drove the following frequencies through each cable:
Conductive SMAs:
X: 29.537 MHz Y: 29.5372 MHz
Isolated SMAs:
X: 29.545 MHz Y: 29.5452 MHz
Each time, the difference between the frequencies was 200 Hz, so if there was crosstalk, a spike should appear in the PSDs at 200 Hz when frequencies are being driven through both cables simulataneously, but not when just one is on. We very clearly see a spike at 200 Hz in both the X arm and the Y arm with the conductive SMAs, indicating crosstalk. For the front panel with isolated SMAs, we see a spike at 200 Hz when both frequencies are on, but it is much less pronounced than with the conductive SMAs. It seems as though there will be crosstalk using either panel, just less with the isolated SMAs. |
Attachment 1: conductive_X.png
|
|
Attachment 2: conductive_Y.png
|
|
Attachment 3: isolated_X.png
|
|
Attachment 4: isolated_Y.png
|
|
11483
|
Thu Aug 6 09:16:57 2015 |
Steve | Update | VAC | Chiara gets new Ethernet card |
- Yesterday we did put the vacuum system into safe to reboot mode for the ethernet card swap.
- Atm1, IFO pressure
- Atm2, as prepared valve configuration where " moving " means closed and disconnected
|
Attachment 1: ChiaraNetCard.png
|
|
Attachment 2: 23.png
|
|
11482
|
Thu Aug 6 04:36:41 2015 |
ericq | Update | ASC | Reviving PRC angular feedforward |
Tonight, I've taken a bunch of data where the PRC is carrier locked and the ITM oplevs have the DC coupling FM turned on, as we use during locking. This is to inform new feedforward filters to stabilize the PRC angular motion, by using Wiener filtering with the POP QPD as the target, and local seismometers/accelerometers as witnesses. So far I've looked at the 1800 seconds leading up to GPS time 1122885600, but there has been plenty of locked time tonight if I need to retrieve more.
I've also measured the PRM ASC output torque -> POP QPD spot motion with high (>0.95) coherence from 0.1Hz to 10Hz.
Prefiltering so far consists of a 4th order elliptic LP at 5 Hz, with the target subtraction band being the 1-3Hz range.
With offline FIR filtering, the RMS pitch motion is reduced by a factor of 3 just with the STS1_X data. IIR fitting remains to be done.
The PRC yaw motion, which is marginally noisier, is a little more tangled up across X and Y.
Plots / filters forthcoming pending more analysis. |
11481
|
Thu Aug 6 01:38:19 2015 |
ericq | Update | Computer Scripts / Programs | Chiara gets new Ethernet card |
Since Chiara's onboard ethernet card has a reputation to be flaky in Linux, Koji suggested we could just buy a new ethernet card and throw it in there, since they're cheap.
I've installed a Intel EXPI9301CT ethernet card in Chiara, which detected it without problems. I changed over the network settings in /etc/networking/interfaces to use eth1 instead of eth0, restarted nfs and bind9, and everything looked fine.
Sadly, EPICS/network slowdowns are still happening. :( |
11480
|
Wed Aug 5 17:15:08 2015 |
Eve | Update | Summary Pages | Fixed ASC Tab |
I've fixed the ASC tab on the summary pages to populate the graphs with data without causing an error.
Motivation: The ASC tab was showing no data. It resulted in a name error when generated.
What I did:
A name error indicates a bad channel name in the plot definition. I identified two errors in the code:
- I said C1:SUS_MC1_ASCPIT_OUT16.mean instead of C1:SUS-MC1_ASCPIT_OUT16.mean (underscore should be dash)
- The channel C1:ASX-XARM_M1_PUT_OSC_CLKGAIN was resulting in a name error. I removed it.
Results:
The plots are not processing without error. However, no titles or axis labels are present on the plots- I'll work on adding these.
|
11479
|
Wed Aug 5 10:56:07 2015 |
ericq | Update | CDS | Many models crashed |
Last night around 1AM, many of the the frontend models crashed due to an ADC timeout. (But none of the IOPs, and all the c1lsc models were fine.)
First, on c1sus (Wed Aug 5 00:56:46 PDT 2015)
[1502036.695639] c1rfm: ADC TIMEOUT 0 46281 9 46153
[1502036.945259] c1pem: ADC TIMEOUT 0 56631 55 56695
[1502036.965969] c1mcs: ADC TIMEOUT 1 56706 2 56770
[1502036.965971] c1sus: ADC TIMEOUT 1 56706 2 56770
Then, simultaneously on c1ioo, c1iscex, and c1iscey. (Wed Aug 5 01:10:53 PDT 2015)
[1509007.391124] c1ioo: ADC TIMEOUT 0 46329 57 46201
[1509007.702792] c1als: ADC TIMEOUT 1 63128 24 63192
[2448096.252002] c1scx: ADC TIMEOUT 0 46293 21 46165
[2448096.258001] c1asx: ADC TIMEOUT 0 46669 13 46541
[1674945.583003] c1scy: ADC TIMEOUT 0 46297 25 46169
[1674945.685002] c1tst: ADC TIMEOUT 0 52993 1 52865
I'm still working on getting things back up and running. Just restarting models wasn't working, so I'm trying some soft reboots...
UPDATE: A soft reboot of all frontends seems to have worked, |
Attachment 1: crashes.png
|
|
11478
|
Tue Aug 4 03:02:30 2015 |
ericq | Update | LSC | Beat note Alignment fluctuation effects measured |
Notes from tonight's work:
- PMC alignment tweaked. Not much gained
- WFS/MC2 offsets tweaked after recentering beams on WFS and some hand alignment.
- Vertex oplevs realigned for the first time in forever
- With an RF coupler, measured the X green beatnote to be +5dBm into the splitter. This resulted in -33dBm at the control room analyzer.
- Switched the ALS demod board inputs, from piping the delayed signal to the RF input, to sendingit to the LO input. This was motivated by wanting the mixer closer to compression, hopefully to reduce beatnote amplitude fluctuation sensitivity. This won some noise >100Hz.
- This led to record ALS noise levels - X:217Hz, Y:203Hz

- +2dBm into the board still leaves us some headroom for futher amplification. Board schematic lists +10dBm LO as "nominal," but maybe this isn't worth it...
- PRFPMI locking is still stalled at bringing in the RF signals. Debugging continues.
- Some beatnote amplitude fluctuation investigations (see below)
- Note to self: demod board schematics include an unspecified RF lowpass. Check out what got stuffed in there.
I've explored the beatnote fluctuations a bit further.
First, I realized that we already had a channel than functions much like an RF level monitor: the phase tracker Q output. I verified that indeed, the Q signal agrees with the RF monitor signals from the demod board within the phase tracker bandwidth. This simplifies things a little.
I also found that the Y beat suffers a fair bit less from these effects; which isn't too surprising given our experience with the alignment stability.
One possible caveat to my earlier conclusions is that the beatnote amplitude could be fluctuating due to real RIN of the green light transmitted through the cavity. In fact, this effect is indeed present, but can't explain all of the coherence. If it did, we would expect the DC green PDs (ALS-TR[X/Y]) to show the same coherence profile as the RF monitors, which they don't.

The next thing I was interested was whether the noise level predicted via coherence was realistic.
To this end, I implemented a least-squares subtraction of the RF level signal from the phase tracker output. I included a quadratic term of the RF power, but this turned out to be insiginficant.
Indeed, using the right gain, it is possible to subtract some noise, reproducing nearly the same spectrum as the coherence based estimate. The discrepency at 1Hz is possible from 1Hz cavity RIN, as suggested by the presence of some coherence with TRX.

However, this is actually kind of weird. In reality, I would've expected the coupling of RF level fluctuations to be more like a bilinear coupling; changing the gain of the mixer, rather than directly introducing a linearly added noise component. Maybe I just discovered the linear part, and the bilinear coupling is the left over low frequency noise... I need to think this over a little more. |
Attachment 1: coherences.png
|
|
Attachment 2: linX.png
|
|
11477
|
Mon Aug 3 18:19:09 2015 |
Jessica | Update | General | Anodization of front panels accounted for |
Previously, I had gotten the same results for the conductive and the isolated front panels. Today, I sanded off the anodized part on the back of the conductive front panel. I checked afterwards with a mulitmeter to ensure that it was indeed conductive through all the SMA connectors.
I drove a frequency of 29.359 Hz through the X Arm cable and 29.3592 Hz through the Y Arm cable, giving a difference of 200 Hz. Previously, there would only be a spike in the Y Arm at the difference, while the X Arm did not change if the Y arm was on or off. Now that the panel is fully conductive, a spike can also be seen in the X arm, indicating that crosstalk may possibly be happening with this panel, now that the spike corresponds to both the X arm and Y arm. These results are only after one set of data. Tomorrow I'll take two more sets of data with this panel and do a more in depth comparison of these results to what had been previously seen. |
Attachment 1: redo_conduct1X.png
|
|
Attachment 2: redo_conduct1Y.png
|
|
11476
|
Mon Aug 3 08:16:19 2015 |
Steve | Update | SUS | ETMX damping restored |
|
Attachment 1: ETMXrestored.png
|
|
11475
|
Sat Aug 1 20:46:29 2015 |
Koji | Update | PEM | X seismo station short cable removed |
OMG |
11474
|
Sat Aug 1 17:04:29 2015 |
Eve | Update | Summary Pages | States and Triggers in SPs |
I've added states to the summary pages to only show data for times at which one certain channel is above a specified threshold. So far, I've incorporated states for the IOO tab to show when the mode cleaner is locked.
You can see these changes implemented in the IOO tab of my personal summary pages for June 30: https://ldas-jobs.ligo.caltech.edu/~eve.chase/summary/day/20150630/ioo/.
I've written a description of how to add states to summary pages here: https://wiki-40m.ligo.caltech.edu/DailySummaryHelp#How_to_Define_and_Implement_States. |
11473
|
Fri Jul 31 10:36:22 2015 |
Steve | Update | PEM | X seismo station short cable removed |
Quote: |
Atm1, New short-50" long cable was installed at ETMY end ( Y-station ) between Guralp-B ( MIT ) and granite base.
Interface box input 2 was left connected to cable 1 and input 1 to cable 2. This plot shows no change.
Atm2, Than I swapped the two long cables at the interface box
Now the signal seems to be ok <2 Hz,
>2 Hz some problem exist.
Channel Name |
Location |
Seismometer |
40m long cable |
Interfacebox input
|
50" short cable
|
C1:PEM-RMS_GUR2X_.... |
ETMX |
Guralp -A |
2 |
2 |
Jenne's friend |
C1:PEM-RMS_GUR1X_.... |
ETMY |
Guralp-B |
1 |
1 |
Koji |
I will look for more bad soldering tomorrow. How many cables did she make?
|
We have to redo this cable also |
Attachment 1: IMG_0009.JPG
|
|
11472
|
Thu Jul 30 19:12:52 2015 |
Ignacio | Update | IOO | YAW and PIT WFS Wiener filtering |
Rana pointed out that another way to mitigate seismic motion at in the mode cleaner would be to look at the YAW and PITCH output channels of the WFS sensors that control the angular alignment of the mode cleaner.
I downloaded 45 mins of data from the following two channels:
C1:IOO-WFS1_YAW_OUT_DQ
C1:IOO-WFS1_PIT_OUT_DQ
And did some quick offline Wiener filtering with no preweighting, the results are shown in the PSD's below,

and

I'm quite surprised at the Wiener subtraction obtained for the YAW signal, it required no preweighting and there is about an order of magnitude improvement in our region of interest, 1-3 Hz. The PIT channel didn't do so bad either.
|
Attachment 1: YAW.png
|
|
Attachment 2: PIT.png
|
|
11471
|
Thu Jul 30 18:58:36 2015 |
Jessica | Update | General | ALS Delay Line Box Front Panel Testing |
I tested both of the front panels (conductive and isolated SMAs) with the ALS Delay Line Box by driving extremely close frequencies through the cables. By doing this, we would expect that a spike would show up in the PSD if there was crosstalk between the cables.
In the plots below, for the conductive panel, the frequencies used were
X Arm: 22.329 MHz Y Arm: 22.3291 MHz
For the isolated panel, the frequencies were
X Arm: 22.294 MHz Y Arm: 22.2943 MHz
This gives a difference of 100 Hz for the conductive panel and 300 Hz for the isolated panel. Focusing on these areas of the PSD, it can be seen that in the Y Arm cable there is a very clear spike within 30 Hz of these differences when frequencies are being driven through both cables as opposed to the signal being in only the Y Arm. In the X Arms, the noise in general is higher when both cables are on, but there is no distinct spike at the expected frequencies. This indicates that some sort of crosstalk is probably happening due to the strong spikes in the Y Arm cables.
|
Attachment 1: Xarm_diff.png
|
|
Attachment 2: Yarm_diff.png
|
|
Attachment 3: Xarm_isolated.png
|
|
Attachment 4: Yarm_isolated.png
|
|
11470
|
Thu Jul 30 15:58:00 2015 |
ericq | Update | LSC | Beat note Alignment fluctuation effects measured |
However, I wonder how much of the low frequency noise can be explained by instability of the beat alignement on the PSL table, and how this might be quantified.
|
I followed my hunch, and the truth comes out.
I recalled that the aLIGO demod board has a handy DB9 output on the back panel for the detected power at the RF and LO inputs. I hooked this up into the BEATY ADC channels while checking the ALSX spectrum in IR lock.
This is assuredly the limiting factor in our ALS sensitivity.
Note: I'm calling the fluctuations of the beatnote amplitude "RF Amplitude RIN," to put things in reasonble units. I haven't looked up the board's conversion of dBm to V, but the LO should be around 0dBm in this measurement.
 
The coherence between the phase tracker output and the LO amplitude is significant over a broad range, mostly dipping where real cavity motion peeks up into the spectrum.
Also, the feature from 10-100Hz in the RIN spectrum is one I've often seen directly in ALS spectra when beatnote alignement is bad or the beatnote frequency is high, convincing me further that this is what's to blame.
So: what do we do? Is there anything we can do to make the green alignment more stable? |
Attachment 1: RF_RIN.png
|
|
Attachment 2: RF_RINspec.png
|
|
Attachment 3: RFampCoh.xml.zip
|
11469
|
Thu Jul 30 15:24:54 2015 |
Steve | Update | PEM | Y sesimostation is back on |
Atm1, New short-50" long cable was installed at ETMY end ( Y-station ) between Guralp-B ( MIT ) and granite base.
Interface box input 2 was left connected to cable 1 and input 1 to cable 2. This plot shows no change.
Atm2, Than I swapped the two long cables at the interface box
Now the signal seems to be ok <2 Hz,
>2 Hz some problem exist.
Channel Name |
Location |
Seismometer |
40m long cable |
Interfacebox input
|
50" short cable
|
C1:PEM-RMS_GUR2X_.... |
ETMX |
Guralp -A |
2 |
2 |
Jenne's friend |
C1:PEM-RMS_GUR1X_.... |
ETMY |
Guralp-B |
1 |
1 |
Koji |
I will look for more bad soldering tomorrow. How many cables did she make?
|
Attachment 1: NewShortCable-Y-B-Gur2.png
|
|
Attachment 2: interfaceInputSwapped.png
|
|
Attachment 3: sameasAtm2.png
|
|
11468
|
Thu Jul 30 14:42:03 2015 |
ericq | Update | LSC | aLIGO demod board lives! |
ALS is not currently limited by the demod board or whitening electronics.
The noise budget in the green locking paper shows the main noise sources to be these two, plus the residual fluctuations of the green PDH loop.
So, one next step is AUX PDH noise budget.
However, I wonder how much of the low frequency noise can be explained by instability of the beat alignement on the PSL table, and how this might be quantified.
Yesterday, I put together a few measurements to asses whether the new demod board has moved us in the right direction. Specifically I measured the output of the phase tracker in the following states, adjusting the phase tracker gain to maintain a ~2kHz UGH (but no boost on):
- Whitening chassis inputs terminated. BEAT_I input channels were given a 3000 count offset to give the phase tracker something to work with. This is a typical beatnote amplitude with the new RF amplifiers.
- aLIGO LSC demod board driven with an SRS SD345 at 30MHz. (First with +3dBm into the splitter, which is about what it sees with the green beatnotes, then with +13dBm into the splitter, to give the board the +10dBm LO it expects)
- Arms locked with POX, POY. AUX laser temperature servos on. Green beatnotes in the 20-40MHz range.
Results: The beat frequency spectrum is above the measured demod board and whitening chassis/ADC noise at all frequencies. It's a little close at 10Hz.
One nice feature is that the beat spectra are far more similar to each other than they used to be. RMS noise is in the 300-400Hz range, which isn't mindblowing, but not terrible. On the order of 50 pm for each arm. Most of this comes from below 10Hz.
Another thing to note is that, when we switch in the 50m cables, we should win a fair bit of Hz/V gain and push down these noises futher. (We're currently using 30m cables.)

By looking at some coherences, we can attribute some of the noise when IR locked to both colors of PDH loops.
Specifically, the coherence with the Green PDH error implicates the residual frequency noise of the AUX laser above a few hundred Hz, whereas the feature from 20-50Hz is probably real cavity motion, not ALS sensing noise. Some of the 1-3Hz noise is from real suspension/stack resonances too.

If it turns out that we do want to push the demod board noise down further, we could think about increasing the RF amplification. Driving the board harder translates directly to better noise performance. The 60Hz harmonics aren't so exciting, but not the end of the world.

Data files are attached, if you're in to that sort of thing. |
Attachment 1: partialALSbudget.png
|
|
Attachment 2: demodDriveLevels.png
|
|
Attachment 3: ALScoherences.png
|
|
Attachment 4: partialALSbudget.zip
|
11467
|
Thu Jul 30 14:27:18 2015 |
Eve | Update | Summary Pages | ALS, ASC, LSC Summary Pages |
I've switches the ALS, ASC, and LSC plots on the summary pages from plotting raw frames, to plotting minute trends, instead. Now, the plots contain information, instead of being completely blank, but data is not recorded on the plots after 12UTC.
Typically, I make changes to the summary pages on my own version of the pages, found at https://ldas-jobs.ligo.caltech.edu/~eve.chase/summary/day/, where I change the summary pages for June 30 and then import such changes into the main summary pages.
|
11466
|
Thu Jul 30 13:34:52 2015 |
Koji | Update | PEM | Y sesimostation is back on |
Please check the spectra. If something is wrong, please swap the cables between X and Y in order to see if the cable is still the issue. I believe the cable was nicely made as I carefully checked the connection twice or more during and after the soldering work. |
11465
|
Thu Jul 30 11:47:54 2015 |
Koji | Summary | CDS | Status of the frame data syncing |
Today it was synced at 5AM but that was all.
40m:
controls@nodus|minute > pwd
/frames/trend/minute
controls@nodus|minute > ls -l 11222|tail
-rw-r--r-- 1 controls controls 35521183 Jul 29 21:59 C-M-1122264000-3600.gwf
-rw-r--r-- 1 controls controls 35509281 Jul 29 22:59 C-M-1122267600-3600.gwf
-rw-r--r-- 1 controls controls 35511705 Jul 29 23:59 C-M-1122271200-3600.gwf
-rw-r--r-- 1 controls controls 35809690 Jul 30 00:59 C-M-1122274800-3600.gwf
-rw-r--r-- 1 controls controls 35752082 Jul 30 01:59 C-M-1122278400-3600.gwf
-rw-r--r-- 1 controls controls 35927246 Jul 30 02:59 C-M-1122282000-3600.gwf
-rw-r--r-- 1 controls controls 35775843 Jul 30 03:59 C-M-1122285600-3600.gwf
-rw-r--r-- 1 controls controls 35648583 Jul 30 04:59 C-M-1122289200-3600.gwf
-rw-r--r-- 1 controls controls 35643898 Jul 30 05:59 C-M-1122292800-3600.gwf
-rw-r--r-- 1 controls controls 35704049 Jul 30 06:59 C-M-1122296400-3600.gwf
controls@nodus|minute > ls -l 11223|tail
total 139616
-rw-r--r-- 1 controls controls 35696854 Jul 30 08:02 C-M-1122300000-3600.gwf
-rw-r--r-- 1 controls controls 35675136 Jul 30 08:59 C-M-1122303600-3600.gwf
-rw-r--r-- 1 controls controls 35701754 Jul 30 09:59 C-M-1122307200-3600.gwf
-rw-r--r-- 1 controls controls 35718038 Jul 30 10:59 C-M-1122310800-3600.gwf
LDAS Minute trend:
[koji.arai@ldas-pcdev3 C-M-11]$ pwd
/archive/frames/trend/minute-trend/40m/C-M-11
[koji.arai@ldas-pcdev3 C-M-11]$ ls -l |tail
-rw-r--r-- 1 1001 1001 35518238 Jul 29 19:59 C-M-1122256800-3600.gwf
-rw-r--r-- 1 1001 1001 35514930 Jul 29 20:59 C-M-1122260400-3600.gwf
-rw-r--r-- 1 1001 1001 35521183 Jul 29 21:59 C-M-1122264000-3600.gwf
-rw-r--r-- 1 1001 1001 35509281 Jul 29 22:59 C-M-1122267600-3600.gwf
-rw-r--r-- 1 1001 1001 35511705 Jul 29 23:59 C-M-1122271200-3600.gwf
-rw-r--r-- 1 1001 1001 35809690 Jul 30 00:59 C-M-1122274800-3600.gwf
-rw-r--r-- 1 1001 1001 35752082 Jul 30 01:59 C-M-1122278400-3600.gwf
-rw-r--r-- 1 1001 1001 35927246 Jul 30 02:59 C-M-1122282000-3600.gwf
-rw-r--r-- 1 1001 1001 35775843 Jul 30 03:59 C-M-1122285600-3600.gwf
-rw-r--r-- 1 1001 1001 35648583 Jul 30 04:59 C-M-1122289200-3600.gwf
|
11464
|
Thu Jul 30 10:38:18 2015 |
Steve | Update | PEM | Y sesimostation is back on |
Koji soldered new 50" long cable for the Y station.
|
Attachment 1: Guralps_are_back_on.png
|
|
Attachment 2: Ystation.jpg
|
|
11463
|
Thu Jul 30 03:19:24 2015 |
ericq | Update | LSC | Back towards PRFPMI |
The refreshed ALS didn't look so bad today (elog forthcoming), so I decided to give PRFPMI locking a shot tonight. I was able to hold the PRMI while swinging through resonsance, but transitions to RF signals failed. Demod angles / whitening gains/ etc. etc. all need to be rechecked
Some little things here and there that got cleaned up...
- The PRM oplev beam was being blocked. Why? I removed the block. Should recheck OLTF/spot size on QPD.
- ALS -> CARM, DARM signs changed, maybe because I've used the delayed beat as the RF input on the demod board, whereas I imagine it may have been the LO in the beatbox. No big deal.
- REFL165 whitening gain and input matrix updated. Should recheck demod angles.
- PRMI triggering settings weren't being set in the script. It's important to include arm transmission signals, since POP2F signals can momentarily dive when swinging through resonance.
- I should revisit phase tracker UGF normalization. I/Q amplitudes are varying quite a bit from lock to lock.
- PRC angular feedforward disabled for now; need to remeasure the witness/target data with DC coupled ITM oplevs
- I think there has been a little bit of MC servo tweaking since our last locks, may need to recheck AO TF / gains.
|
11462
|
Thu Jul 30 02:06:20 2015 |
Ignacio | Update | IOO | MC2 <-> MCL Actuator TF fitted |
Eric downloaded MC2 to MCL transfer function data (H) as well as its inverse, MCL to MC2 (Hinv). He also downloaded new MCL and MC2 data.
I used vectfit to fit the MC2 to MCL transfer function,

The ZPK parameters for this fit were,
Zeros 1278.36719876674 + 0.00000000000000i
-100.753249679343 + 0.00000000000000i
-18.6014192997845 + 13.0294910760217i
-18.6014192997845 - 13.0294910760217i
Poles -1.11035771175328 + 7.03549674098987i
-1.11035771175328 - 7.03549674098987i
-18.8655320274072 + 0.00000000000000i
-690.294337433234 + 0.00000000000000i
Gain 0.00207206036014220
Using the above vectfit model, I filtered the raw MC2 signal to get 'MCL'. The PSD's of the raw MCL data and the filtered MC2 result is shown below,

The lack of accuracy of the transfer function at replicating MCL at frequencies lower than 0.7Hz is expected, the vectfit model I generated fails to follow accurately the raw transfer function data. My question: Does it matter? My guess: Probably not. In order to mitigate seismic noise from the mode cleaner we are mainly concerened with the 1-3 Hz region.
I also used vectfit to fit the transfer function for MCL to MC2,

This one was harder to fit accurately for some reason, I could do it with four pairs of zeros and poles but it took some preweighting.
The ZPK parameters for the above fit were,
Zeros 0.173068278283995 + 0.00000000000000i
0.995140531040529 + 0.0268079821980457i
0.995140531040529 - 0.0268079821980457i
0.894476816129099 + 0.00000000000000i
Poles -19.9566906920707 + 18.0649464375308i
-19.9566906920707 - 18.0649464375308i
-109.275971483008 + 0.00000000000000i
-1791.88947801703 + 0.00000000000000i
Gain 1237.46417532120
Similarly, using this ZPK model, I filtered the MCL signal to get 'MC2'. I plotted the PSD for the MC2 signal and the filtered MCL to get,

Again, the lack of accuracy of the filtered MC2 at replicating MCL below 0.7 Hz and above 12 Hz is due to the inverse transfer function failing to converge in these ranges. |
Attachment 1: TF_BODE.png
|
|
Attachment 2: MC2_2_MCL.png
|
|
Attachment 3: TF_INV_BODE.png
|
|
Attachment 4: MCL_2_MC2.png
|
|
11461
|
Wed Jul 29 21:40:39 2015 |
Koji | Summary | CDS | Status of the frame data syncing |
The trend data hasn't been synced with LDAS since Jul 27 5AM local.
40m:
controls@nodus|minute > pwd
/frames/trend/minute
controls@nodus|minute > ls -l 11222 | tail
total 590432
-rw-r--r-- 1 controls controls 35758781 Jul 29 11:59 C-M-1122228000-3600.gwf
-rw-r--r-- 1 controls controls 35501472 Jul 29 12:59 C-M-1122231600-3600.gwf
-rw-r--r-- 1 controls controls 35296271 Jul 29 13:59 C-M-1122235200-3600.gwf
-rw-r--r-- 1 controls controls 35459901 Jul 29 14:59 C-M-1122238800-3600.gwf
-rw-r--r-- 1 controls controls 35550346 Jul 29 15:59 C-M-1122242400-3600.gwf
-rw-r--r-- 1 controls controls 35699944 Jul 29 16:59 C-M-1122246000-3600.gwf
-rw-r--r-- 1 controls controls 35549480 Jul 29 17:59 C-M-1122249600-3600.gwf
-rw-r--r-- 1 controls controls 35481070 Jul 29 18:59 C-M-1122253200-3600.gwf
-rw-r--r-- 1 controls controls 35518238 Jul 29 19:59 C-M-1122256800-3600.gwf
-rw-r--r-- 1 controls controls 35514930 Jul 29 20:59 C-M-1122260400-3600.gwf
LDAS Minute trend:
[koji.arai@ldas-pcdev3 C-M-11]$ pwd
/archive/frames/trend/minute-trend/40m/C-M-11
[koji.arai@ldas-pcdev3 C-M-11]$ ls -l | tail
-rw-r--r-- 1 1001 1001 35488497 Jul 26 19:59 C-M-1121997600-3600.gwf
-rw-r--r-- 1 1001 1001 35477333 Jul 26 21:00 C-M-1122001200-3600.gwf
-rw-r--r-- 1 1001 1001 35498259 Jul 26 21:59 C-M-1122004800-3600.gwf
-rw-r--r-- 1 1001 1001 35509729 Jul 26 22:59 C-M-1122008400-3600.gwf
-rw-r--r-- 1 1001 1001 35472432 Jul 26 23:59 C-M-1122012000-3600.gwf
-rw-r--r-- 1 1001 1001 35472230 Jul 27 00:59 C-M-1122015600-3600.gwf
-rw-r--r-- 1 1001 1001 35468199 Jul 27 01:59 C-M-1122019200-3600.gwf
-rw-r--r-- 1 1001 1001 35461729 Jul 27 02:59 C-M-1122022800-3600.gwf
-rw-r--r-- 1 1001 1001 35486755 Jul 27 03:59 C-M-1122026400-3600.gwf
-rw-r--r-- 1 1001 1001 35467084 Jul 27 04:59 C-M-1122030000-3600.gwf
|
11460
|
Wed Jul 29 17:51:56 2015 |
Ignacio | Update | PEM | Accelerators moved back to MC1 and MC2 |
We are done taking accelerator huddle test data. So I moved back all six accelerometers and cables to MC1 and MC2. I also relabel each of the accelerometers properly since the labels on them were confusing.
 
QED
|
Attachment 1: FullSizeRender.jpg
|
|
Attachment 2: FullSizeRender_2.jpg
|
|
11459
|
Wed Jul 29 14:32:01 2015 |
Steve | Update | General | How not to solder |
Quote: |
Quote: |
Koji and Steve,
The result: bad Guralp x-arm cable.
I will swap the short cables tomorrow at the base.
|
Short 46" long cables at the base plates were swapped. Their solderings looked horrible.
This cable actually worked at 5-5-2015
Bad cable at ETMY station now. The new cable should be a little bit longer ~52"
|
Koji could pull out easily 11 of the wires from their socket. |
Attachment 1: coldSoldering.jpg
|
|
11458
|
Wed Jul 29 11:15:21 2015 |
Jessica | Summary | LSC | PSDs of Arms with seismometer subtraction |
Ignacio and I downloaded data from the STS, GUR1, and GUR2 seismometers and from the mode cleaner and the x and y arms. The PSDs along the arms have the most noise at frequencies greater than 1 Hz, so we should focus on filtering in that area. The noise levels start dropping at around 30 Hz, but are still much higher than is seen at frequencies below 1 Hz. However, because the spectra is so low at frequencies below that, Wiener filtering alone injected a significant amount of noise into those frequencies and did not do much to reduce the noise at higher frequencies. Pre-filtering will be required, and I have started implementing a pre-filter, but with no improvements yet. So far, I have tried making a bandpass filter, but a highpass filter may be ideal in this case because so much of the noise is above 1 Hz. |
Attachment 1: Arms_PSD.png
|
|
Attachment 2: XArm_PSD.png
|
|
Attachment 3: YArm_PSD.png
|
|
11457
|
Wed Jul 29 10:34:42 2015 |
Ignacio | Summary | LSC | Coherence of arms and seismometers |
Jessica and I took 45 mins (GPS times from 1122099200 to 1122101950) worth of data from the following channels:
C1:IOO-MC_L_DQ (mode cleaner)
C1:LSC-XARM_IN1_DQ (X arm length)
C1:LSC-YARM_IN1_DQ (Y arm length)
and for the STS, GUR1, and GUR2 seismometer signals.
The PSD for MCL and the arm length signals is shown below,

I looked at the coherence between the arm length and each of the three seismometers, plot overload incoming below,
For the coherence between STS and XARM and YARM,

For GUR1,

Finally for GUR2,

A few remarks:
1) From the coherence plots, we can see that the arm length signals are coherent with the seismometer signals the most from 0.5 - 50 Hz. This is most evident in the coherence with STS. I think subtraction will be most useful in this range. This agrees with what we see in the PSD of the arm length signals, the magnitude of the PSD starts increasing from 1 Hz and reaches a maximum at about 30 Hz. This is indicative of which frequencies most of the noise is present.
2) Eric did not remember which of GUR1 and GUR2 corresponded to the ends of XARM and YARM. So, I went to the end of XARM, and jumped for a couple seconds to disturb whatever Gurald was in there. Using dataviewer I determined it was GUR1. Anyways, my point is, why is GUR1 less coherent with both arms and not just XARM? Since it is at the end of XARM, I was expecting GUR1 to be more coherent with XARM. Is it because, though different arms, the PSD's of both arms are roughly the same?
3) Similarly, GUR2 shows about the same levels of coherence for both arms, but it is more coherent. Is GUR2 noisier because of its location?
Code: ARMS_COH.m.zip |
Attachment 1: PSD_ARMS_MCL.png
|
|
Attachment 2: XARM_STS_COH.png
|
|
Attachment 3: YARM_STS_COH.png
|
|
Attachment 4: XARM_GUR1_COH.png
|
|
Attachment 5: YARM_GUR1_COH.png
|
|
Attachment 6: XARM_GUR2_COH.png
|
|
Attachment 7: YARM_GUR2_COH.png
|
|
Attachment 8: ARMS_COH.m.zip
|
11456
|
Tue Jul 28 20:42:50 2015 |
Jessica | Summary | General | New Seismometer Data Coherence |
I was looking at the new seismometer data and plotted the coherence between the different arms of C1:PEM_GUR1 and C1:PEM_GUR2. There was not much coherence in the X arms, Y arms, or Z arms of each seismometer, but there were within the x and y arms of the seismometer.
I think the area we should focus on with filtering is lower ranges, between 0.01 and 0.1, because that it where coherence is most clearly high. It is higher in high frequencies but also incredibly noisy, meaning it probably wouldn't be good to try to filter there. |
Attachment 1: Coherence1.png
|
|
Attachment 2: Coherence2.png
|
|
11455
|
Tue Jul 28 17:07:45 2015 |
Jamie | Update | General | Data missing |
Quote: |
For the past couple of days, the summary pages have shown minute trend data disappear at 12:00 UTC (05:00 AM local time). This seems to be the case for all channels that we plot, see e.g. https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20150724/ioo/. Using Dataviewer, Koji has checked that indeed the frames seem to have disappeared from disk. The data come back at 24 UTC (5pm local). Any ideas why this might be?

|
Possible explanations:
- The data transfers to LDAS had been shut off while we were doing the DAQ debugging. I don't know if they have been turned back on. Unlikely this is the problem since you would probably see no data at all if this were the case.
- wiper script parameters might have been changed to store less of the trend data for some reason.
- Frame size is different and therefore wiper script parameters need to be adjusted.
- Steve deleted it all.
- ...
|
11454
|
Tue Jul 28 16:42:25 2015 |
Steve | Update | General | Jamies entry was deleted |
Sorry Jamie, I accidentally deleted your elog entry #11453 |
11453
|
Tue Jul 28 15:06:27 2015 |
Steve | Update | IOO | PSL HEPA turned on |

|
Attachment 1: noHepa.jpg
|
|
11452
|
Tue Jul 28 15:05:09 2015 |
Steve | Update | safety | fire alarm test ? no |
We just had fire alarm trigged avacuation of the 40m lab.
It turned out that the CES building second floor sensor caused this action. |
Attachment 1: 6minGaps.png
|
|
11451
|
Tue Jul 28 14:58:59 2015 |
Steve | Update | General | do not place anything on optical table tops |
Specially heavy items: old analoge scope or hardware loaded boxes......etc
The table cover section holding crossbars are not evenly spaced.
You have to center each cover section on the cross bar so it is supported on both sides !
I will clean up on this table tomorrow
|
Attachment 1: tabletops!.jpg
|
|
Attachment 2: tabletops!!.jpg
|
|
11450
|
Tue Jul 28 09:31:35 2015 |
Ignacio | Update | General | Newest accelerometer huddle test |
I downloaded new accelerometer huddle test data from last night and analyzed it. This new data set is ~55 mins and uses the same Wiener filter parameters as previous huddle test analysis, the main difference being six accelerometers used in the Wiener filter and the improved experimental set up.
After computing the ASD for the self noise for each of the six accelerometers, (being witnessed by the remaining five), we get,

Now computing the mean of the above signals and the corresponding error bars gives the following result,

Comparing to prevoius huddle tests, I can note two trends on the Wiener subtraction:
1) When using six accelerometers, the subtraction above ~8 Hz drastically improves.
2) When using three accelerometers, there is better cancellation in the 1-5 Hz region, see http://nodus.ligo.caltech.edu:8080/40m/11442. This might have to do with how much more closer the accelerometers are to each other? |
Attachment 1: selfnoise_allsix_miso_newest.png
|
|
11449
|
Tue Jul 28 05:00:03 2015 |
Ignacio | Update | General | Seismometer cans |
I've have been talking a little bit with Steve about the seismometer enclosures.
We want to improve on the current stainless steel cans that cover the two Guralps at the end of the arms. In order to do this, we want to cover the interior of the cans with copper foil to improve the thermal conductivity of the enclosure to better control the temperature inside it. Ideally, we would want to copper plate the cans, but cost and difficulty has been an issue.
I have done some rough calculations and it seems that we need a copper layer of thickness being about a third that of the stainless steel can. This happens to be around 0.5-0.6 mm since we have 16 gauge (~1.6 mm) stainless steel cans.
After wrapping the cans interior with copper, we will insulate them with foam in order to improve its thermal inertia. We want to probably use the same foam that Megan has been using for her seismometer enclosure. I have yet to think about a heater, but something similar to Megans resistor thing would work only smaller. I would be placed inside the can, right on the center of its bottom in order to ditribute heat evenly.
|
11448
|
Mon Jul 27 17:51:06 2015 |
Eve | Update | Summary Pages | New summary page tabs and other improvements |
The summary pages can still be found at https://nodus.ligo.caltech.edu:30889/detcharsummary/ (EDIT: in an older version of this post I listed an incorrect url). They are operational and include data from some channels for intermittent periods of time.
Motivation: to make the summary pages more informative and useful for all
What I did:
I have added tabs for ALS, ASC, and LSC subsystems. While there is currently no data on the plots, I plan on checking all channels with DataViewer to set appropriate axis ranges so that we can actually see the data.
I altered which channels are used to represent spectra for OpLev systems to more appropriately provide PSDs.
I've changed the check code status page to include "warning" labels. Previously, when the summary pages ran, resulting in a warning message, the check code status page would list this as an "error", implying that the summary pages were not properly produced.
Results:
All features were implemented, but I need to investigate some of these channels to understand why we aren't seeing many channels in the plots. I am working on some other changes to the summary pages, including providing a Locked status which will only show data in a timeseries for a selected period of time. |
11447
|
Mon Jul 27 16:47:53 2015 |
ericq | Update | IOO | MC2 -> MCL Actuator TF |
Our noise cancellation SURFS will be doing online subtraction on the mode cleaner length, among other things.
I made a measurement of the MC2 actuator transfer function by injecting noise from 1-100Hz into LSC_MC2_EXC for about 15 minutes, then estimating the TF from MC2_OUT to IOO_MC_L with CSD/PSD. The inverse of this TF will be applied to their Wiener target data to give us the direct subtration filter we want.
I figured I would post the results here for posterity. The last time this seems to have been done is in ELOG 5900. There are some differences found here, the effective Q of the 1Hz pendulum resonance seems lower, and the behavior above 20Hz has definitely changed.
IIR fits will be done by one of the SURFs to be used in their Wiener filter calculations.

Data attached! |
Attachment 1: mc2_2_mcl.png
|
|
Attachment 2: MC2_2_MCL_TF.txt.zip
|
11446
|
Fri Jul 24 23:08:53 2015 |
Ignacio | Update | PEM | MC1 accelerators moved for future huddle test |
I have moved the MC1 accelerators and cable to the huddle test set up, in order to see how a six witness huddle test with the improved set up will do.
Here is a picture of the accelerometer set up,

Our motivation for doing this is to see if more witness signals used in the Wiener filter really does indeed improve subtraction, as it was seen from previous huddle results, specially in the region above 10 Hz. |
11445
|
Fri Jul 24 20:32:15 2015 |
ericq | Update | Electronics | LSC LO distribution box power button replaced |
As happened with the RF distribution box in the IOO rack a while back, the shiny blue power button in the LSC LO distribution box failed today. I replaced it with a simple switch, but since the original was a double throw, the replacement was way too big to fit without major panel surgery. So, instead, I installed it in the grille on the roof of the chassis. It a tight press/snap fit, though; I don't think it is at risk of easily coming loose.
After reinstalling the box, I confirmed that POX POY and AS55 could all lock arms, so I deem the operation a success.
Before:

After:

|
Attachment 1: 2015-07-24_15.43.56.jpg
|
|