ID |
Date |
Author |
Type |
Category |
Subject |
11342
|
Mon Jun 1 20:05:36 2015 |
rana | Update | CDS | RCG Upgrade Imminent |

Quote: |
Additionally, we want to have some set of tests and diagnostics, to make sure we have not introduced unwanted behavior.
To this end I will create some test models and DTT templates, where a series of measurements can be run, like
- OLTF/delay measurement of a single all-digital loop within one model
- OLTF/delay measurements of a few all-digital loops split across two models, using IPC communcation, RFM, dolphin
- Hook up DAC -> resistor/amplifier/??? -> ADC, to check things like DAC output, ADC noise levels, IOP delays.
I'll run these test before touching anything, and make sure I understand all of the results, so that an apples-to-apples comparison can be made after the upgrade is complete.
|
I got goosebumps just imagining this. |
11341
|
Mon Jun 1 15:22:19 2015 |
Steve | Update | PEM | Guralps X- short cable is bad |
Quote: |
Koji and Steve,
The result: bad Guralp x-arm cable.
I will swap the short cables tomorrow at the base.
|
Short 46" long cables at the base plates were swapped. Their solderings looked horrible.
This cable actually worked at 5-5-2015
Bad cable at ETMY station now. The new cable should be a little bit longer ~52" |
Attachment 1: seismGur1-2.png
|
|
11340
|
Mon Jun 1 10:26:53 2015 |
ericq | Update | CDS | RCG Upgrade Imminent |
We are planning on upgrading the 40 CDS system to the latest version of the LIGO RCG software, in three weeks when Jamie is back in town.
Jamie and I spoke last week, to hash out a general plan for upgrade and preperations I can make in the meantime.
Preparation of our models for the upgrade includes;
- Check if any of the default RCG parts (filter modules, etc.) have substantially different default behavior / ports
- Cleaning up unterminated/hanging connections in the diagrams (Jamie tells me RCG is more strict about this now)
- Going through all of the build logs for our models to find what custom blocks are being pulled in from the userapps svn
- Confirm all of our running blocks and models are committed to svn
- In a new, isolated, folder, checkout the latest version of the userapps repo
- See what blocks have changed, and what model changes might be neccesary.
Once we think we know what needs to be changed in our models, we can check out the latest version of the RCG source, without linking it as the active version, and create a new build directory, without touching the old one, and create new copies of the 40m models with the neccesary modifications. This way, we can work on getting all of the 40m models compiled, without touching any of the live, running, systems.
Once our models are compiling successfully, we can work on building daqd, nds, mxstream, etc.
Additionally, we want to have some set of tests and diagnostics, to make sure we have not introduced unwanted behavior.
To this end I will create some test models and DTT templates, where a series of measurements can be run, like
- OLTF/delay measurement of a single all-digital loop within one model
- OLTF/delay measurements of a few all-digital loops split across two models, using IPC communcation, RFM, dolphin
- Hook up DAC -> resistor/amplifier/??? -> ADC, to check things like DAC output, ADC noise levels, IOP delays.
I'll run these test before touching anything, and make sure I understand all of the results, so that an apples-to-apples comparison can be made after the upgrade is complete.
Updates will be posted as I hash things out. I'm sure we have not yet thought of everything to think about and test, so ideas and feedback are very welcome. |
11339
|
Mon Jun 1 08:32:14 2015 |
Steve | Update | SUS | PRM damping restored |
Local earthquake 3.8 Mag tripped only PRM
Vac monitor is not communicating.
PSL HEPA turned on
|
Attachment 1: indio3.8Meq.png
|
|
11338
|
Fri May 29 15:12:39 2015 |
Koji | Update | Computer Scripts / Programs | Chiara Backup Hiccup |
Actual data |
Attachment 1: backup_hours.pdf
|
|
11337
|
Fri May 29 12:49:53 2015 |
Koji | Update | Computer Scripts / Programs | Chiara Backup Hiccup |
In fact, the file access is supposed to be WAY faster now than in the RAID case.
As noted in ELOG 9511, it was SCSI-2(or 3?) that had ~6MB/s thruput. Previously the backup took ~2hours.
This was improved to 30min by SATA HDD on llinux1.
I am looking at /opt/rtcds/caltech/c1/scripts/backup/rsync.backup.cumlog
In fact, this "30-min backup" was true until the end of March. After that the backup is taking 1h~1.5h.
This could be related to the recent NFS issue? |
11336
|
Fri May 29 11:28:42 2015 |
ericq | Update | Computer Scripts / Programs | Chiara Backup Hiccup |
I've changed the chiara local backup script to read a folder exclusion file, and excluded /users/public_html/detcharsummary, and things are working again.
This was neccesary because the summary pages are being updated every half hour, which is faster than the time it takes for the backup script to run, so the file index that it builds at the start becomes invalid later on in the process.
Thinking about chiara's disk, it strikes me that when we went from the linux1 RAID to a single HDD on chiara, we may have tightened a bottleneck on our NFS latency, i.e. we are limited to that single hard drive's IO rates. This of course isn't the culprit for the more recent dramatic slowdowns, but in addition to fixing whatever has happened more recently, we may want to consider some kind of setup with higher IO capability for the NFS filesystem. |
11335
|
Fri May 29 02:05:08 2015 |
ericq | Update | LSC | End Laser temperatures set |
Both green beatnotes have been found with nominal amplitudes. (X: -30dBm Y: -20dBm), at temperatures which don't seem to be prone to mode hopping.
X = 42.64, Y ~40.15
Both arms can lock on ALS, but as Koji mentioned in ELOG 11334, the ALS noise seems anomalously high.
Details
The temperatures I posted in the previous log ended up not being so useful. To find the right end laser temperatures, I looked at the IR beatnotes on the control room analyzer out to 1GHz, and swept around the SLOW_SERVO2_OFFSET channels to change the laser temperature. During this time, the end green shutters were closed, the PSL shutter was closed, the FSS slow servo was off, and the FSS_SLOWDC was set to 0.0. (The green PSL shutter had to be open, because the IR beat fiber is coupled after it.)
For each arm, I found three temperatures where an IR beat could be observed; as Koji mentioned on Wednesday, we should use the middle mode. For each of the arms, scanning around from the middle to move the beat by +-1GHz did not cause a mode hop - the beat stayed visible on the scope. Once I found a real IR beat for the X arm, I took at look at the RF output of the X BBPD, and found my alignment from the other night was actually pretty good; I made a minor touch up to maximize the green beat.
For the AUX X innolight, I was able to find the actual temperature of the laser crystal when at the correct point, remove the digital offset, and return to the same temperature with the controller front panel dial. This temperature is 42.64 degrees Celcius. There is no diode temperature control on the unit, as far as I could tell, but the maximum green transmitted power through the X arm is about the same as it's ever been, around GTRX=0.5.
My motivation for doing this was that I always have problems remembering the historical typical values for the digital temperature offset. It seems much cleaner to me to set things up such that a beat is visible "at the origin" (i.e. FSS_SLOWDC=0 and SLOW_SERVO2_OFFSET=0) I suppose that this will also depend on what mode of the PMC we're locked to. During my time working today, its been locked near the middle of its range, currently sitting at 145V.
However, for the AUX Y lightwave, I was a little perplexed to find that moving the the laser crystal setpoint around does not apear to change the real laser temperature at all. Thus I could not offload the digital offset in the same way. Aditionally, the lightwave controller does not have the same temperature measuring accuracy as the innolight, even with the back panel voltage readout that is hooked up to the multimeter that lives under the optical table. The best I can tell is around 40.1-40.2 degrees C. Y_SLOW_SERVO2_OFFSET of -10690 counts gives a beat <100MHz at FSS_SLOWDC=0. This is actually very close to the previous operating point, so the same mode seems to still work.
The arms now easily lock on ALS, albeit with higher noise. With arms locked on ALS, POX and POY show >1kHz rms noise.
I gave the PRFPMI locking script a few tries, but it's having problems keeping the PRMI locked. The ALS is a few times noisier than usual, and I haven't revisited the validity of the PRC angular feedforward, so I'm not so surprised. |
11334
|
Thu May 28 21:10:46 2015 |
Koji | Update | Green Locking | ALS-X noise hunting |
I have been looking at the X-end ALS setup.
I was playing with the control bandwidth to see the effect to the phase tracker output (i.e. ALS err).
For this test the arm was locked with the IR and the green beat note was used as the monitor.
From the shape of the error signal, the UGF of the green PDH was ~10kHz. When I increased the gain
to make the servo peaky, actually the floor level of the ALS err became WORSE. I did not see any improvement
anywhere. So, high residual error RMS cause some broadband noise in the ALS??? This should be checked.
Then when the UGF was lowered to 3kHz, I could see some bump at 3kHz showed up in the ALS error.
I didn't see the change of the PSD below 1kHz. So, more supression of the green PDH does not help
to improve the ALS error?
Then, I started to play with the phase tracker. It seems that someone already added the LF booster
to the phase tracker servo. I checked the phase tracker error and confirmed it is well supressed.
Further integrator does not help to reduce the phase tracker error.
For the next thing I started to change the offset of the phase tracker. This actually changes
the ALS error level! The attached plot shows the dependence of the ALS error PSD on the phase tracker
output. At the time of this measurement, the offset of -10 exhibited the best noise level.
This was, indeed, factor of 3~5 improvement compared to the zero offset case below 100Hz.
I'm afraid that this offset changes the beat frequency as I had the best noise level at the offset of -5
with a different lock streatch. We should look at this more carefully. If the beat freq changes the offset,
this give us another reason to fix the beat frequency (i.e. we need the frequency control loop.
= Today's ALSX error would have not been the usual low noise state.
We should recover the nominal state of the ALS and make the same test = |
Attachment 1: 150528_ALS.pdf
|
|
11333
|
Thu May 28 17:12:32 2015 |
ericq | Update | IOO | FSS SLOW not engaged: is this intentional? |
Yes, I had turned it off while looking for the PSL/X AUX beat, and forgot to turn it back on.
I will post an elog with more detail this evening, but I found a temperature which restored the X green beatnote at its nominal amplitude (-30dBm) with no mode hops within +-1 IR beat GHz, and offloaded the slow offset slider to the X-end laser crystal dial. I will look for the Y beatnote after dinner.
Currently the control room analyzer is hooked up to recieve the Y IR and green beats; no X signals. |
11332
|
Thu May 28 17:00:04 2015 |
Koji | Update | IOO | FSS SLOW not engaged: is this intentional? |
I found that FSS SLOW servo is not engaged. Is this intentional test to keep the NPRO temp constant?
This is making the FSS Fast unhappy (~ -7.5V right now). |
11331
|
Thu May 28 16:43:52 2015 |
Steve | Update | PEM | Guralps swapped |
Koji and Steve,
The result: bad Guralp x-arm cable.
I will swap the short cables tomorrow at the base.
|
Attachment 1: GursSwapped.png
|
|
11330
|
Thu May 28 15:10:44 2015 |
rana | Update | PEM | Seismic Confusion |
You are plotting the STS channels, not Guralp. These are for the Trillium 240 seismometer.
Also, you cannot tell if the seismometer is working by plotting the MEAN trend. That just gives the average and we need the fluctuations. Better off looking at the spectrum like I did last time.
And....its not good enough to just do the bubble. You have to do the mass centering procedure that you and I did last time with the breakout paddle. |
11329
|
Thu May 28 10:42:19 2015 |
Steve | Update | PEM | bad Guralp X-cable |
Quote: |
Tried swapping cables at the Guralp interface box side. It seems that all of our seismic signal problems have to do with the GUR2 cable being flaky (not surprising since it looks like it was patched with Orange Electrical tape!! rather than proper mechanical strain relief).
After swapping the cables today, the GUR2 DAQ channels all look fine: i.e. GUR1 (the one at the Y end) is fine, as is its cable and the GUR2 analog channels inside the interface box.
OTOH, the GUR1 DAQ channels (which have GUR2 (EX) connected into it) are too small by a factor of ~1000. Seems like that end of the cable will need to be remade. Luckily Jenne is still around this week and can point us to the pinout / instructions. Looks like there could be some shorting inside the backshell, so I've left it disconnected rather than risk damaging the seismometer. We should get a GUR1 style backshell to remake this cable. It might also be possible that the end at the seismometer is bad - Steve was supposed to swap the screws on the granite-aluminum plate on Thursday; I'll double check.
|
The Guralps were swapped.
What I did: turned DC power off at 1X1, hand carried them, centered each leveling bubbles, gently locked the jack screws and turned power back on.
ETMY at the east end now has CMG-T40-0008, sn T4157 as channel C1:PEM-SEIS_STS_1_Y_OUT_DQ.........
ETMX at south end now has CMG-T40-0053, sn T4Q17 as channel C1:PEM-SEIS_STS_2_Y_OUT_DQ.........
Conclusion: Guralps are fine. X cable is bad. It was bad 6 months ago when it was made.
We can still swap the 3ft short cables at the granite base if Rana has not done it.
|
Attachment 1: Gurs180dXbad.png
|
|
Attachment 2: swappedGurs.png
|
|
11328
|
Wed May 27 17:14:08 2015 |
ericq | Update | LSC | X Aux Laser crystal temperature changed |
Rana suspects that the lack of X beatnote is related to the PSL laser temperature change (ELOG 11294).
I used the information on the wiki and old elogs (wiki-40m, ELOG 6732), to deduce that the new end laser temperatures should be:
- X end-> 38.98 C
- Y end-> 35.80 C
I went out to the X end and found the laser crystal temperature set to 40.87, which is not what the measurements I linked to suggest would be the ideal temperature for the previous NPRO laser temperature of 30.89, which would be 37.02. I could not find any elog describing the choice of this setpoint.
I've changed the X end laser crystal temperature to the value above. I've hooked up the X IR and green beatnotes to go the control room analzyer, and have been looking for the beatnote as I adjust the digital temperature offset, but haven't found it yet...
If this proves totally fruitless, we can just put the lasers back to their original temperatures, since it's unclear if it helped the PC drive noise levels. |
11327
|
Wed May 27 15:20:54 2015 |
ericq | Update | Computer Scripts / Programs | Chiara Backup Hiccup |
The local chiara backups are still failing due to vanished source files. I've emailed Max about the summary page jobs, since I think they're running remotely. |
11326
|
Wed May 27 02:53:57 2015 |
ericq | Update | General | ifo recovery log |
Given my suspicion of fault with the X Green BBPD, Koji generously provided me with another one that he had confirmed to be working.
However, I turns out I was mistaken. With the existing BBPD, I did indeed witness a beat in the RF output, but it is somehow something like 20dBm smaller than it should be. This is why I missed it the other night. Here's a video of a RF output on a scope, wherein the beat is only barely visible because I've set the trigger level very low. I could not make the beatnote any larger through any alignment motions; I had gotten to this point by doing near/far field overlap on the PSL table.
I'm not sure what could have caused this. Mode mismatch? By eye, the beam spots looked about the same in the near and far fields, and we haven't had to touch the mode matching in quite some time... I've given up on trying to solve this for tonight.
Just for kicks, I hooked up the fiber PD IR beatnotes as inputs to the ALS DFD. The X beat is too small to even really see above the control room analyzer's noise floor, but the Y beat looked big enough. With the arms locked on IR, the phase tracker output RMS was a few kHz, so not even worth thinking about any further. Not so surprising.
Finally, I put back / hooked up everything in its nominal state. |
11325
|
Tue May 26 19:57:11 2015 |
rana | Update | Computer Scripts / Programs | ifoCoupling |
Looks like a very handy code, especially with the real statistical tests.
I would make sure to use much smaller excitation amplitudes. Since the coupling is nonlinear, we expect that its only a good noise budget estimator when the excitation amplitude is less than a factor of 3 above the quiesscent excitation. |
11324
|
Tue May 26 11:05:10 2015 |
Steve | Update | PEM | worked around ETMY seism. |
The cable tray holder cross beam is removed and cut short for good access to seismometer. |
Attachment 1: ETMYseismic.png
|
|
Attachment 2: cut.jpg
|
|
11323
|
Sun May 24 14:45:02 2015 |
Koji | HowTo | General | How to launch StripTools at specified locations |
LLO Operator Tips:
koji.arai@cr9:/opt/rtcds/userapps/trunk/asc/l1/scripts/initial_alignment$ cat autostart_strips.sh
#!/bin/bash
# Baffle window setup 1500x480
StripTool -xrm 'StripTool.StripGraph.geometry:1500x470+0+24' /opt/rtcds/userapps/trunk/asc/l1/scripts/initial_alignment/baffle_pd.stp &
sleep 1
# DC signals setup
StripTool -xrm 'StripTool.StripGraph.geometry:1500x470+0+470' /opt/rtcds/userapps/trunk/asc/l1/scripts/initial_alignment/dc_signals.stp &
sleep 1
# WFS prx mich sry setup
StripTool -xrm 'StripTool.StripGraph.geometry:1500x470+0-24' /opt/rtcds/userapps/trunk/asc/l1/scripts/initial_alignment/wfs_prx_mich_sry.stp &
sleep 1
exit
|
11322
|
Sat May 23 22:43:10 2015 |
ericq | Update | General | ifo recovery log |
Running train-of-thought elog:
East N2 cylinder found empty, replaced. West is >2kpsi
Removed Yuta-specific code from damprestore. A grep for 'yuta' in the python files within /scripts/ shows some other occurances, but nothing that is really in use at this time. New feature of damprestore.py: remembers oplev status.
Ran LSCoffsets.
WFS offsets relieved (all <20).
Adjusted FSS offset to minimize MC_FAST_MON
ASS ran (but the arm alignment has been astoundingly stable lately. I haven't touched it all this week)
ITMX is the only optic that got a correction over 20 counts.
BS and *TM oplev spots look well centered, except for ITMX.
I undid the gain reduction rana introduced because X ASS seemed to be really slow. It is currently fine in its older state. What's going on here?
Some network latency stuff is going on, even freezing up terminals when trying to write text files. This may (or may not) be correlated with the summary page rysnc jobs on nodus. It occurs to me that we have a DAQ ethernet network seperate from the martian network, but the frame transfers need to go through the martian network, since nodus is the only way out to the outside world. If we had a machine/gateway directly from the DAQ network to the caltech network, the martian network wouldn't get bogged down when frames are being uploaded
GTRY = 0.55, ok. Aligned GTRX to 0.52, also ok
Y beatnote was found easily. Have spent >30 minutes looking for X green beatnote. Typical FSS slow and X temperature ranges don't seem to be giving much. Will check the beat alignment with a scope, but if the beat is too high to begin with, it may not work...
I suspect a problem with the X Green BBPD
I could see the IR beatnote between the PSL and AUX X lasers at the input to the frequency counter. (I believe it is a real beatnote because it reacted as expected to the end temperature moving, and stabilizing the end laser to the arm). However, when placing the IR beatnote at a frequency which should've made the green beatnote visible on an analyzer and/or scope, no beatnote was found. I played with the beat alignment to no avail; the DC output of the BBPD behaved as expected, but I never saw anything in the RF output or on the control room analyzer. I also checked the beatnote signal chain by hooking up a 1mV 26MHz signal into the cable that hooks up to the RF out of the BBPD; the signal showed up clearly on the control room analyzer.
I'm not sure what may have happened. ELOG 9996 may be related.
I'm calling it a night. |
11321
|
Fri May 22 18:09:58 2015 |
ericq | Update | Computer Scripts / Programs | ifoCoupling |
I've started working on a general routine to measure noise couplings in our interferometers. Often this is done with swept sine measurements, but this misses the nonlinear part of the coupling, especially if the linear part is alreay reduced through some compensation or feedforward scheme. Rana suggested using a series of narrow band-limited noise injections.
The structure I'm working on is a python script that uses the AWG interface written by Chris W. to create the excitations. Afterwards, I calculate a series of PSD estimates from the data (i.e. a spectrogram), and apply a two-sample, unequal variance, t-test to test for statisically significant increases in the noise spectra to try and evaluate the nonlinear contriubutions to the noise. I've started a git repository at github.com/e-q/ifoCoupling with the code.
So far, I've tested one such injection of noise coupling from the ETMX oplev error point to the single arm length error signal. It's completely missing the user interface and structure to do a general series of measurements, but this is just organizational; I'm trying to get the math/science down first.
Here's a result from today:

Median, instead of the usual mean, PSDs are used throughout, to reject outliers/glitches.
The linear part of the coupling can be estimated using the coherence / spectrum height in the excitation band, but I'm not sure what the best what to present/paramerize the nonlinear parts of each individaul excitation band's result is.
Also, I anticipate being able to write an excitation auto-leveling routine, gradually increasing the exctiation level until the excited spectrum is some amount noisier than the baseline spectrum, up to some maximum amount configurable by the user.
The excitation shaping could probably be improved, too. It's currently and elliptic + butterworth bandpass for a sharp edge and rolloff.
I'm open to any thoughts and/or suggestions anyone may have! |
Attachment 1: ETMX_PIT_L_coupling.png
|
|
11320
|
Fri May 22 12:09:57 2015 |
rana | Update | SUS | DampRestore script problem |
I will move it back. We need to fix our scripts to not use any users/ libraries ever again.
Quote: |
PRM watchdog tripped, but the damprestore.py script wouldn't run.
It turns out the script tries to import some ezca stuff from /users/yuta ( ), which had been moved to /users/OLD/yuta ( ).
I've moved the yuta directory back to /users/ until I fix the damprestore script.
|
|
11319
|
Fri May 22 11:59:54 2015 |
ericq | Update | SUS | DampRestore script problem |
PRM watchdog tripped, but the damprestore.py script wouldn't run.
It turns out the script tries to import some ezca stuff from /users/yuta ( ), which had been moved to /users/OLD/yuta ( ).
I've moved the yuta directory back to /users/ until I fix the damprestore script. |
11318
|
Wed May 20 11:41:59 2015 |
ericq | Update | General | some status |
West cyclinder is empty, east is at 2000 psi; regulated N2 pressure is 64psi. I'll replace the west one after the meeting. |
11317
|
Wed May 20 03:08:27 2015 |
rana | Update | General | some status |
I think that the real clue was that the dropouts are in some channels and not in others:
https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20150519/psl/
As it turns out, the channel with no dropouts is the RAW PSL RMTEMP channel. All the others are the minute trends. So something is up with the trend making or the trend reading in the cluster.
Quote: |
There's a few hours so far after today's c1cal shut off that the summary page shows no dropouts. I'm not yet sure that this is related, but it seems like a clue.
|
|
11316
|
Tue May 19 19:24:30 2015 |
rana | Update | PEM | Seismic BLRMS filters |
I was wondering about the design of the BLRMS fitlers for the seismic channels since the STS ones seem to have so little gain compared to the Guralps.
Here are some plots of the Bode magnitude and impulse responses of the bandpass filters (before the low passing). There's a bunch of entries from Masha on this from her SURF summer. Can anyone comment on why they are all so different?
One of the old Masha entries speaks of designing the lowpass filter in an intelligent way: by adjusting the filter order until the power in the stopband is less than 1% of the power in the passband. Seems like we could do that for bandpass too. For now I have made the names reasonable and changed all of the BP filters to 4th order Butterworth.
Also, it turns out that the Vel2Vel (gain ~0.02) filters were mistakenly on in the STS BP filter banks. The GUR inputs have a gain to scale the counts to velocity, but the STS seem to already be in microns/sec (where is this gain?) so I turned off and deleted the Vel2Vel filters; in any case the gain should not be done seperately in each BP bank, but altogether before the BP filtering. |
Attachment 1: BLRMS_BP.pdf
|
|
Attachment 2: BLRMS_imp.pdf
|
|
11315
|
Tue May 19 18:55:12 2015 |
rana, ericQ | Update | General | some status |
After one day the pressures are east/west = 2200/450 PSI
Quote: |
- New east pressure reading is 2500 PSI. Regulated N2 pressure is 68 PSI.
|
|
11314
|
Tue May 19 18:38:33 2015 |
rana | Update | CDS | MXstream restart script working (beta) |
Good catch; that was some seriously bad programming on my part. I had some undeclared variable garbage going on. I fixed it and re-implemented the script in CRON on megatron. The log file shows that it has detected no problems for the last several checks. I'll check it again tomorrow to see if its doing good or bad. |
11313
|
Tue May 19 17:53:38 2015 |
rana | Update | Modern Control | Brushing up on Wiener Filtering |
Good to see that misofw.m is still alive and well. Todo:
- Apply weighting to the filter via time domain SOS prefiltering of the signals (see Jenne's code from the LLO Global FF paper)
- Consider using some of the MC SUSPOS signals. Its not strictly legal, but I wonder if its responsible for out noise below 1 Hz.
- Steve was in the midst of hooking up the Wilcoxones to get better subtraction at 5-15 Hz, but couldn't find cables. We need to hunt them down in W Bridge.
- Attach one of the medium or big Lings to the MC2 chamber platform and see if we can do this in hardware without driving the suspension. WE want to use a DAC channel (from where?) and pipe it to the Ling using a medium high current drive. Might start with the 50 Ohm output of the SR560 and later use a BUF634 ala Crackle coil driver.
|
11312
|
Tue May 19 17:03:34 2015 |
Koji | Update | CDS | MXstream restart script working (beta) |
AutoMX is resetting mx_stream every 5 minutes. Basically everytime AutoMX is called,
it resets mx_stream. Is the mx_stream stalling such often? Or the script is detecting false alerms?
> tail -200 /opt/rtcds/caltech/c1/scripts/cds/autoMX.log
Tue May 19 16:43:01 PDT 2015
LSC - FB bad. Runnning restart:
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1sus closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1lsc closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1ioo closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1iscex closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1iscey closed.
0
Tue May 19 16:48:02 PDT 2015
LSC - FB bad. Runnning restart:
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1sus closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1lsc closed.
ssh_exchange_identification: read: Connection reset by peer
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1iscex closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1iscey closed.
0
Tue May 19 16:53:01 PDT 2015
LSC - FB bad. Runnning restart:
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1sus closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1lsc closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1ioo closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1iscex closed.
* Stopping mx_stream ... [ ok ]
* Starting mx_stream ... [ ok ]
Connection to c1iscey closed.
|
11311
|
Tue May 19 16:18:57 2015 |
ericq | Update | General | crons fixed |
I wrapped rampdown.py in rampdown.sh, which is just these lines:
#!/bin/bash
source /ligo/cdscfg/workstationrc.sh
/opt/rtcds/caltech/c1/scripts/SUS/rampdown.py > /dev/null 2>&1
This is now what megatron's cron runs. It appears to be working.
I also added the workstationrc line to the n2 and chiara HDD checking scripts that run on nodus, which should resolve the issue from ELOG 11249 |
11310
|
Tue May 19 14:51:44 2015 |
ericq | Update | Modern Control | Brushing up on Wiener Filtering |
As part of preparing for the SURF projects this summer, I grabbed ~50 minutes of MCL and STS_1 data from early this morning to do a little MISO wiener filtering. It was pretty straightforward to use the misofw.m code to achieve an offline subtraction factor of ~10 from 1-3Hz. This isn't the best ever, but doesn't compare so unfavorably to older work, especially given that I did no prefiltering, and didn't use all that long of a data stretch.
Code and plot (but not data) is attached. |
Attachment 1: mclData.png
|
|
Attachment 2: mclWiener.zip
|
11309
|
Tue May 19 11:50:52 2015 |
manasa | Update | PEM | No noticeable effect from M4.0 earthquake |
There was an earthquake: M4.0 - 40km SSW of South Dos Palos, California
No noticeable effects on the IFO. MC did not lose lock; however the arms did unlock. |
11308
|
Tue May 19 11:24:44 2015 |
ericq | Update | Computer Scripts / Programs | Notification Scheme |
Given some of the things we've facing lately, it occurs to me that we could be better served by having some sort of unified human-alerting scheme in place, for things like:
- Local/offsite backup failures
- Vaccumm system problems
- HDD status for things like /frames/ and /cvs/cds/, whether the disks are full, or their SMART status indicates imminent mechanical failure
Currently, many of these things are just checked sporadically when it occurs to someone to do so, or when debugging random issues. Smoother IFO operation and peace of mind could be gained if we're confident that the relevant people are notified in a timely manner.
Thoughts? Suggestions on other things to monitor, like maybe frontend/model crashes? |
11307
|
Tue May 19 11:15:09 2015 |
ericq | Update | Computer Scripts / Programs | Chiara Backup Hiccup |
Starting on the 14th (five days ago) the local chiara rsync backup of /cvs/cds to an external HDD has been failing:
caltech/c1/scripts/backup/rsync_chiara.backup.log:
2015-05-13 07:00:01,614 INFO Updating backup image of /cvs/cds
2015-05-13 07:49:46,266 INFO Backup rsync job ran successfully, transferred 6504 files.
2015-05-14 07:00:01,826 INFO Updating backup image of /cvs/cds
2015-05-14 07:50:18,709 ERROR Backup rysnc job failed with exit code 24!
2015-05-15 07:00:01,385 INFO Updating backup image of /cvs/cds
2015-05-15 08:09:18,527 ERROR Backup rysnc job failed with exit code 24!
...
Code 24 apparently means "Partial transfer due to vanished source files."
Manually running the backup command on chiara worked fine, returning a code of 0 (success), so we are backed up. For completeness, the command is controls@chiara: sudo rsync -av --delete --stats /home/cds/ /media/40mBackup
Are the summary page jobs moving files around at this time of day? If so, one of the two should be rescheduled to not conflict. |
11306
|
Tue May 19 00:19:23 2015 |
rana | Update | General | some status |
There's a few hours so far after today's c1cal shut off that the summary page shows no dropouts. I'm not yet sure that this is related, but it seems like a clue. |
Attachment 1: Screen_Shot_2015-05-19_at_12.17.39_AM.png
|
|
11305
|
Mon May 18 18:03:12 2015 |
rana | Update | General | some status |
The c1cal model was maxing out its CPU meter so I logged onto c1lsc and did 'rtcds c1cal stop'. Let's see if this changes any of our FB / DAQD problems. |
Attachment 1: CPUtrend.png
|
|
11304
|
Mon May 18 17:44:30 2015 |
rana | HowTo | CDS | Bypassing the CDSUTILS prefix issue |
Too weird. I undid me changes. We'll have to make the C1: stuff work inside each python script.
Quote: |
This makes things act weird:
controls@pianosa|MC 1> z avg 1 "C1:LSC-TRY_OUT"
IFO environment variable not specified.
|
|
11303
|
Mon May 18 17:42:14 2015 |
rana, ericQ | Update | General | some status |
Today at 5 PM we replaced the east N2 cylinder. The east pressure was 500 and the west cylinder pressure was 1000. Since Steve's elogs say that the consumption can be as high as 800 per day we wanted to be safe.
- We closed the black valve before the regulator and closed the valve on the cylinder.
- We unscrewed the brass fill line to the cylinder.
- We unchained the cylinder and put in the dolly (and attached the chains on there).
- We rolled in a fresh cylinder from outside using the red dolly (it should have chains).
- We put it in place, hooked up the chains, and screwed on the brass nozzle with the large adjustable wrench (need to put a non-adjustable here).
- Opened up the cylinder valve.
- Opened up the black valve.
- New east pressure reading is 2500 PSI. Regulated N2 pressure is 68 PSI.
Quote: |
1) Checked the N2 pressures: the unregulated cylinder pressures are both around 1500 PSI. How long until they get to 1000?
|
|
11302
|
Mon May 18 16:56:12 2015 |
ericq | HowTo | CDS | Bypassing the CDSUTILS prefix issue |
This makes things act weird:
controls@pianosa|MC 1> z avg 1 "C1:LSC-TRY_OUT"
IFO environment variable not specified.
|
11301
|
Mon May 18 16:28:18 2015 |
ericq | Update | General | some status |
Quote: |
4) Noticed that DAQD is restarting once per hour on the hour. Why?
|
It looks like daqd isn't being restarted, but in fact crashing every hour.
Going into the logs in target/fb/logs/old, it looks like at 10 seconds past the hour, every hour, daqd starts spitting out:
[Mon May 18 12:00:10 2015] main profiler warning: 1 empty blocks in the buffer
[Mon May 18 12:00:11 2015] main profiler warning: 0 empty blocks in the buffer
[Mon May 18 12:00:12 2015] main profiler warning: 0 empty blocks in the buffer
[Mon May 18 12:00:13 2015] main profiler warning: 0 empty blocks in the buffer
...
***CRASH***
An ELOG search on this kind of phrase will get you a lot of talk about FB transfer problems.
I noticed the framebuilder had 100% usage on its internal, non-RAID, non /frames/, HDD, which hosts the root filesystem (OS files, home directory, diskless boot files, etc), largely due to a ~110GB directory of frames from our first RF lock that had been copied over to the home directory. The HDD only has 135GB capacity. I thought that maybe this was somehow a bottleneck for files moving around, but after deleting the huge directory, daqd still died at 4PM.
The offsite LDAS rsync happens at ten minutes past the hour, so is unlikely to be the culprit. I don't have any other clues at this point. |
11300
|
Mon May 18 14:46:20 2015 |
manasa | Summary | General | Delay line frequency discriminator for FOL error signal |
Measuring the voltage noise and frequency response of the Analog Delay-line Frequency Discriminator (DFD)
The schematic and an actual photo of the setup is shown below. The setup was checked to be physically sturdy with no loose connections or moving parts.

The voltage noise at the output of the DFD was measured using an SR785 signal analyzer while simultaneously monitoring the signal on an oscilloscope.
The noise at the output of the DFD was measured for no RF input and at several RF input frequencies including the zero crossing frequency and the optimum operating frequency of the DFD (20MHz).
The plot below show the voltage noise for different RF inputs to the DFD. It can be seen that the noise level is slightly lower at the zero crossing frequency where the amplitude noise is eliminated by the DFD.

I also did measurements to obtain the frequency response of the setup as the cable length difference has changed from the prior setup. The cable length difference is 21cm and the obtained linear signal at the output of the DFD extends over ~ 380MHz which is good enough for our purposes in FOL. A cosine fit to the data was done as before. //edit- Manasa: The gain of SR560 was set to 20 to obtain the data shown below//
Fit Coefficients (with 95% confidence bounds):
a = -0.8763 (-1.076, -0.6763)
b = 3.771 (3.441, 4.102)

Data and matlab scripts are zipped and attached. |
Attachment 4: DFD.zip
|
11299
|
Mon May 18 14:22:05 2015 |
ericq | Update | Computer Scripts / Programs | rsync frames to LDAS cluster |
Quote: |
Still seems to be running without causing FB issues.
|
I'm not so sure. I just was experiencing some severe network latency / EPICS channel freezes that was alleviated by killing the rsync job on nodus. It started a few minutes after ten past the hour, when the rysnc job started.
Unrelated to this, for some odd reason, there is some weirdness going on with ssh'ing to martian machines from the control room computers. I.e. on pianosa, ssh nodus fails with a failure to resolve hostaname message, but ssh nodus.martian succeeds. |
11298
|
Mon May 18 11:59:07 2015 |
rana | Update | General | some status |
Yes - my rampdown.py script correctly ramps down the watchdog thresholds. This replaces the old rampdown.pl Perl script that Rob and Dave Barker wrote.
Unfortunately, cron doesn't correctly inherit the bashrc environment variables so its having trouble running.
On a positive note, I've resurrected the MEDM Screenshot taking cron job, so now this webpage is alive (mostly) and you can check screens from remote:
https://nodus.ligo.caltech.edu:30889/medm/screenshot.html |
11297
|
Mon May 18 09:50:00 2015 |
ericq | Update | General | some status |
Quote: |
Added this to the megatron crontab and commented out the op340m crontab line. IF this works for awhile we can retire our last Solaris machine.
|
For some reason, my email address is the one that megatron complains to when cron commands fail; since 11:15PM last night, I've been getting emails that the rampdown.py line is failing, with the super-helpful message: expr: syntax error |
11296
|
Sun May 17 23:46:25 2015 |
rana | Update | ASC | IOO / Arm trends |
Looking at the summary page trends from today, you can see that the MC transmission is pretty flat after I zeroed the MCWFS offsets. In addition, the transmission from both arms is also flat, indicating that our previous observation of long term drift in the Y arm transmission probably had more to do with bad Y-arm initial alignment than unbalanced ETMY coil-magnets.
Much like checking the N2 pressure, amount of coffee beans, frames backups, etc. we should put MC WFS offset adjustment into our periodic checklist. Would be good to have a reminder system that pings us to check these items and wait for confirmation that we have done so. |
11295
|
Sat May 16 21:40:29 2015 |
rana | Update | PEM | Guralp maintenance |
Tried swapping cables at the Guralp interface box side. It seems that all of our seismic signal problems have to do with the GUR2 cable being flaky (not surprising since it looks like it was patched with Orange Electrical tape!! rather than proper mechanical strain relief).
After swapping the cables today, the GUR2 DAQ channels all look fine: i.e. GUR1 (the one at the Y end) is fine, as is its cable and the GUR2 analog channels inside the interface box.
OTOH, the GUR1 DAQ channels (which have GUR2 (EX) connected into it) are too small by a factor of ~1000. Seems like that end of the cable will need to be remade. Luckily Jenne is still around this week and can point us to the pinout / instructions. Looks like there could be some shorting inside the backshell, so I've left it disconnected rather than risk damaging the seismometer. We should get a GUR1 style backshell to remake this cable. It might also be possible that the end at the seismometer is bad - Steve was supposed to swap the screws on the granite-aluminum plate on Thursday; I'll double check. |
Attachment 1: GurPost_150516.png
|
|
11294
|
Sat May 16 21:05:24 2015 |
rana | Update | General | some status |
1) Checked the N2 pressures: the unregulated cylinder pressures are both around 1500 PSI. How long until they get to 1000?
2) The IMC has been flaky for a day or so; don't know why. I moved the gains in the autolocker so now the input gain slider to the MC board is 10 dB higher and the output slider is 10 dB lower. This is updated in the mcdown and mcup scripts and both committed to SVN. The trend shows that the MC was wandering away after ~15 minutes of lock, so I suspected the WFS offsets. I ran the offsets script (after flipping the z servo signs and adding 'C1:' prefix). So far powers are good and stable.
3) pianosa was unresponsive and I couldn't ssh to it. I powered it off and then it came back.
4) Noticed that DAQD is restarting once per hour on the hour. Why?
5) Many (but not all) EPICS readbacks are whiting out every several minutes. I remote booted c1susaux since it was one of the victims, but it didn't change any behavior.
6) The ETMX and ITMX have very different bounce mode response: should add to our Vent Todo List. Double checked that the bounce/roll bandstop is on and at the right frequency for the bounce mode. Increased the stopband from 40 to 50 dB to see if that helps.
7) op340 is still running ! The only reason to keep it alive is its crontab:
op340m:SUS>crontab -l
07 * * * * /opt/rtcds/caltech/c1/burt/autoburt/burt.cron >> /opt/rtcds/caltech/c1/burt/burtcron.log
#46 * * * * /opt/rtcds/caltech/c1/scripts/general/scripto_cron /opt/rtcds/caltech/c1/scripts/PSL/FSS/FSSSlowServo > /cvs/cds/caltech/logs/scripts/FSSslow.cronlog 2>&1
#14,44 * * * * /cvs/cds/caltech/conlog/bin/check_conlogger_and_restart_if_dead
15,45 * * * * /opt/rtcds/caltech/c1/scripts/SUS/rampdown.pl > /dev/null 2>&1
#10 * * * * /opt/rtcds/caltech/c1/scripts/general/scripto_cron /opt/rtcds/caltech/c1/scripts/MC/autolockMCmain40m >/cvs/cds/caltech/logs/scripts/mclock.cronlog 2>&1
#27 * * * * /opt/rtcds/caltech/c1/scripts/general/scripto_cron /opt/rtcds/caltech/c1/scripts/PSL/FSS/RCthermalPID.pl >/cvs/cds/caltech/logs/scripts/RCthermalPID.cronlog 2>&1
00 0 * * * /var/scripts/ntp.sh > /dev/null 2>&1
#00 4 * * * /opt/rtcds/caltech/c1/scripts/RGA/RGAlogger.cron >> /cvs/cds/caltech/users/rward/RGA/RGAcron.out 2>&1
#00 6 * * * /cvs/cds/scripts/backupScripts.pl
00 7 * * * /opt/rtcds/caltech/c1/scripts/AutoUpdate/update_conlog.cron
00 8 * * * /opt/rtcds/caltech/c1/scripts/crontab/backupCrontab
added a new script (scripts/SUS/rampdown.py) which decrements every 30 minutes if needed. Added this to the megatron crontab and commented out the op340m crontab line. IF this works for awhile we can retire our last Solaris machine.
8) To see if we could get rid of the wandering PCDRIVE noise, I looked into the NPRO temperatures: was - T_crystal = 30.89 C, T_diode1 = 21 C, T_diode2 = 22 C. I moved up the crystal temp to 33.0 C, to see if it could make the noise more stable. Then I used the trimpots on the front of the controller to maximimize the laseroutput at these temperatures; it was basically maximized already. Lets see if there's any qualitative difference after a week. I'm attaching the pinout for the DSUB25 diagnostics connector on the back of the box. Aidan is going to help us record this stuff with AcroMag tech so that we can see if there's any correlation with PCDRIVE. The shifts in FSS_SLOW coincident with PCDRIVE noise corresponds to ~100 MHz, so it seems like it could be NPRO related.
|
Attachment 1: 48.png
|
|
Attachment 2: 39.png
|
|
11293
|
Sat May 16 20:37:09 2015 |
rana | HowTo | CDS | Bypassing the CDSUTILS prefix issue |
The CDSUTILS package has a feature where it substitutes in a C1 or H1 or L1 prefix depending upon what site you are at. The idea is that this should make code portable between LLO and LHO.
Here at the 40m, we have no need to do that, so its better for us to be able to copy and paste channel names directly from MEDM or whatever without having to remove the "C1:" from all over the place.
the way to do this on the command line is (in bash) to type:
export IFO=''
To make this easier on us, I have implemented this in our shared .bashrc so that its always the case. This might break some scripts which have been adapted to use the weird CDSUTILS convention, so beware and fix appropriately.
|