manasa | Update | General | IOO rack power supply | I shutdown the +/-15V and the +/-24V sorensons on the IOO rack to connect the FOL RF PDs to the rack power supply.
They were turned back ON after the work. PMC and MC were relocked.
Quote: |
[Steve, Manasa]
We ran power cables and sma cables for the FOL fiber module from the PSL table to the IOO rack.
|
|
11078
|
Thu Feb 26 16:37:21 2015 |
manasa | Frogs | LSC | RIP illegal power supply | No more illegal power supply at the LSC rack 
The amplifiers are now being powered by the rack power supply through fuse blocks.
To make new connections, I shutdown the +/-15 V low noise power supplies. They were turned back ON after the work.
Quote: |
Is this your illegally installed HP bench power supply?

If so, or if not but you care about the signal that passes through these amplifiers, I suggest you remove this temporary power supply and wire the power from the rack power supplies through the fuse blocks and possibly use a voltage regulator.
In 24 hours, that power supply will be disconnected and the wires snipped if they are still there.
|
|
11077
|
Thu Feb 26 13:55:59 2015 |
jamie | Update | Computer Scripts / Programs | FB IO load | We should use "ionice" to throttle the rsync. Use something like "ionice -c 3 rsync ..." to set the priority such that the rsync process will only work when there is no other IO contention. See "man ionice" for other options. |
11076
|
Thu Feb 26 13:17:31 2015 |
ericq | Update | Computer Scripts / Programs | FB IO load | Over the past few days, I've occasionally been peeking at the framebuilder IO load to see If I could correlate anything with it, but it's usually been low when I looked. I.e. with daqd and all models running, the %wa time was in the few percents at most.
Just now, I was seeing some EPICS sluggishness, and sure enough, the %wa was in the 50-60 range. I used iostat -xmh 5 on the framebuilder to see that /dev/sda , the /frames drive, was at 100% utilization, which means it was reading and writing as fast as it possibliy could.
I ssh'd over to nodus, and with iotop found that an rsync job was running (rsync -am --exclude .*.gwf full 131.215.114.19::40m/full ), and its IO rates corresponded very closely to the data read rates on the framebuilder from /frames.
I killed the rsync process on nodus, and the %wa time on the framebuilder dropped to near zero. The ASS striptools, where I had noticed the sluggishness, immediately started updating faster.
While rsync is supposed to play nice with a system's IO demands, maybe it only knows about nodus's IO usage, not fb which is the underlying NFS server where the frames live. I think it would be good to throttle the bandwidth of these jobs to a specific bandwidth. 50MB/s seemed like too much, so maybe 10MB/s is ok? |
11075
|
Thu Feb 26 10:56:34 2015 |
manasa | Update | General | Running cables | [Steve, Manasa]
We ran power cables and sma cables for the FOL fiber module from the PSL table to the IOO rack. |
11074
|
Thu Feb 26 01:53:35 2015 |
Koji | Update | LSC | Modelled effect of relative modulation phase | Ok... This is what I was afraid of, and it seems true.
i.e. the relation ship of the modulations for the 3f cancellation is making the PRCL signals cancel each other.
It agrees with Anamaria's analysis that 11x44 is the strongest component in aLIGO 27MHz signal.
In fact,
00x33 has the order of 
11x22 has the order of 
11x44 has the order of 
22x55 has the order of 
Therefore 11x44 is inherently the strongest contribution at 33MHz.
(And then, of couse, the signal amplitudes have additional dependences on the reflectivity
and the gain of the IFO at each freq)
If we believe this result, it may be difficult to exploit the benefit of the signals under the 3f cancellation.
We probably have to go back to the original idea of cancelling the 3f modulation by adding 3f modulation.
(i.e. Produce 33MHz signal by freq tripling, add this signal to Kiwamu's box to elliminate 3f.) |
11073
|
Thu Feb 26 01:51:39 2015 |
ericq | Update | LSC | Sideband HOMs | So, my previous post suggested that 44*11 products might be the dominating signals in our "nominal" setup. I suppose that this could be not so bad, since it's not too unlike -11*22; the 11MHz field couples into the PRC and reflects with a rapidly changing phase around PRC resonance, and 44MHz is antiresonant, so it is a good local oscillator for REFL33.
However, it then occured to me that my previous HOM analysis only looked at the 11MHz and 55MHz sidebands.
When extending this to all of the sidebands within 55MHz, I discovered a troubling fact:
With the IFO parameters I have, the second spatial order +22MHz and fourth spatial order +44MHz fields almost exactly coresonate with the carrier in the PRFPMI! (DR, too)
If this is true, then any REFL33 signal seems to be in danger if we have an appreciable amount of these modes from, say, imperfect modematching.
On the other hand, we've been able to hold the PRMI with REFL33 when ALS is "on resonance," so I'm not sure what to think. (As a reminder, this analysis is done with analytic formulae for the complex reflectivities of the arm cavities and coupled recycling cavities as a function of CARM, spatial order and field frequency. Source is attached.)

It seems the Y arm geometry is to blame for this.
 
Maybe we should try to measure/confirm the Y arm g-factor... |
Attachment 1: C1_HOMcurves_PR.png
|
|
Attachment 2: C1_HOMcurves_Y.png
|
|
Attachment 3: C1_HOMcurves_X.png
|
|
Attachment 4: C1_HOMlist.zip
|
11072
|
Thu Feb 26 00:20:54 2015 |
ericq | Update | LSC | Modelled effect of relative modulation phase | I'm working on some more modelling investigations of this whole situation. The main thing I wanted to do was to look at the complex field amplitudes / IFO reflectivity to see how the PDH signal is affected by different field components.
I still have plenty more to do, but I got a result which I though I should share. In addition to Jenne's simulation, I also see that between our "nominal" and "canceled" states as defined in Kojis ELOG 11036, there is a factor of ~20 difference in the PRCL signal in REFL33.
The plots below are kind of like "PDH Signal Budgets" of the two states.
Specifically, the reason our gain gets reduced is that, in the "canceled" state, the 44*11 and 55*22 products conspire to weaken the signal by having a slope opposite to the -11*22 type products. In contrast, in our "nominal" case, all of the products slope together.
However, this also predicts that the nominal REFL33 is more sensitive to Carrier*33 than to the signal we desire, -11*22. The only reason it ever worked seems to be the biggest contriubutor, the unexpected 44*11!
 
The "residual" trace is the difference of REFL33 and the sum of the field products shown, to justify that all relevant products had been included.
The simulation that produced this was set up to create 4 orders of modulation at each EOM, with 3 orders of sidebands on sidebands. The demodulation phase was taken by lining up a PRM excitation entirely along I, as we would do on the actual instrument.
MIST Simulation files attached! |
Attachment 1: 33budget_canceled.png
|
|
Attachment 2: 33budget_nominal.png
|
|
Attachment 3: 2015-02-ModPhase.zip
|
11071
|
Wed Feb 25 23:48:57 2015 |
rana | Update | LSC | some thoughts |
- Comparing just the 2 cases with locking on 33, it seems that the 55 MHz gain has changed by 14 dB instead of the 10 dB that we expected. Is it that we need to measure the modulation drive change more carefully, or just that the PRMI was aligned differently?
- The 165 signal changed by a factor of 60 (35 dB) which is more consistent with a ~12 dB change in Gamma2, so not so far off.
- The fact that the whole sensing matrix increases in amplitude between 33 and 55 lock makes me think that either the alignment was very bad for the 33 lock, or that the 33 signals have a significant offset; if that's the case, then we should do as LLO and set the digital offsets in the 33 signals by locking first on 55.
- How does the REFL33 demod phase change by 70 deg?
|
11070
|
Wed Feb 25 20:00:39 2015 |
Jenne | Update | LSC | Delay line un-installed again - sensing matrix comparisons | I have measured the sensing matrix for the PRMI at the REFL photodiodes for both the nominal configuration and the 33MHz cancellation configuration. The nominal configuration measurements do not compare well with those from November (http://nodus.ligo.caltech.edu:8080/40m/10701) which makes me unhappy . Both sets of nominal config reported below are from today, after tuning the demod phases and making sure the MICH and PRCL loops looked the same as yesterday (esp. overall gain). The cancellation config data is from last night.
Note that the magnitude for each photodiode is referred to its own "PD counts". Since the electronics are different for each PD, and that is not taken into account here, you cannot directly compare an element from one PD to an element from another PD. What you can do (which is most of what we need right now) is compare all the different measurements for a single photodiode.
PRCL Sensing elements |
33 MHz cancellation, REFL55 I&Q lock |
Nominal, REFL55I&Q lock |
Nominal, REFL33I&Q lock |
|
Mag [PD counts / m] |
Phase [deg] |
Mag [PD counts / m] |
Phase [deg] |
Mag[PD counts / m] |
Phase [deg] |
REFL 11 |
3.0e13 |
0.05 |
4.2e13 |
0.1 |
2.9e13 |
0.1 |
REFL 33 |
1.1e11 |
3.4 |
1.8e12 |
0.25 |
1.2e12 |
0.3 |
REFL 55 |
1.8e10 |
2.1 |
1.4e11 |
4.8 |
9.3e10 |
4.1 |
REFL 165 |
7.0e9 |
15.5 |
6.3e11 |
0.5 |
4.2e11 |
0.9 |
MICH Sensing elements |
33MHz cancellation, REFL55 I&Q lock |
Nominal, REFL55 I&Q lock |
Nominal, REFL33 I&Q lock |
|
Mag [PD counts / m] |
Phase [deg] |
Mag [PD counts / m] |
Phase [deg] |
Mag [PD counts / m] |
Phase [deg] |
REFL 11 |
3.0e12 |
2.8 |
4.1e12 |
3.0 |
2.9e12 |
3.3 |
REFL 33 |
1.1e10 |
3.7 |
1.7e11 |
3.5 |
1.2e11 |
3.9 |
REFL 55 |
2.1e9 |
30.3 |
1.4e10 |
27.7 |
1.1e10 |
30.2 |
REFL165 |
6.4e8 |
24.4 |
6.3e10 |
21.0 |
4.5e10 |
23.0 |
So, what I'm apparently seeing is that the magnitudes of the sensing matrix signals that are made using 55MHz (i.e. everything but REFL11) change when we go into the cancellation configuration, but the phases of the sensing elements do not change significantly. Also, I am apparently seeing that REFL11 and REFL33 only have about 3 degrees of separation between the MICH and PRCL signals no matter what configuration is used. This doesn't make a lot of sense, since we know that we can lock robustly on REFL33I&Q (it's been sitting there happily as I write this elog), so it seems crazy that we could actually be so degenerate. Also, at the bottom of the elog that I wrote in November 2014, I show a sensing matrix where both REFL11 and REFL33 have about 45 degrees of separation between the MICH and PRCL signals.
I don't think I'm doing anything too crazy here, particularly with the phase. For a given PD and given DoF, I find the magnitude of the peaks of the I and Q signals, and just do atan2(Q-signal, I-signal)*180/pi, and those are the numbers that go in the phase columns above.
Before taking my measurements, I tuned up the demod phases for the PRMI-only case. I think REFL11 may have previously been tuned for CARM when the arms were held with ALS, but I don't really recall. Anyhow, now all 4 REFL PDs are tuned for PRMI-only.
This was done while the PRMI was locked with REFL 55 I&Q.
EDIT, 26Feb2015: Last night I mixed up the REFL11 and REFL33 new demod phases. Bold are the corrected version. Also, note that REFL33 was formerly tuned for PRCL in PRFPMI, which may be why it changed by ~10 degrees.
|
Old demod phase [deg] |
New demod phase [deg] |
REFL11 |
20 |
131.7 +/- 0.1 74.7 +/- 0.1 |
REFL33 |
142.2 |
74.7 +/- 0.1 131.7 +/- 0.1 |
REFL55 |
19 |
15.3 +/- 0.3
|
REFL165 |
-172 |
-170.0 +/- 0.2 |
Here's the recipe for locking REFL 55 I&Q in the nominal modulation configuration. It's the same as the REFL33 I&Q lock that I was using today, except that for the REFL33 version, the matrix elements are both unity.
PRMI REFL55 I&Q, nominal configuration |
MICH |
PRCL |
Input Matrix
|
36*REFL55Q |
12*REFL55I |
Gain |
5.0 |
-0.028 |
DoF trigger |
POP22I; 50 up, 0.5 down |
POP22I; 50 up, 0.5 down |
FMs |
FM 4, 5 on |
FM 4, 5 on |
FM trigger |
FM 2, 3, 6, 9; 50 up, 0.5 down, 5 second wait |
FM 1, 2, 6, 8, 9; 50 up, 0.5 down, 1 second wait |
Normalization |
none |
none |
Output matrix |
-1*ITMX, +1*ITMY |
1*PRM |
|
11069
|
Wed Feb 25 14:51:13 2015 |
Jenne | Update | LSC | Delay line un-installed again | And now I've removed the delay line, and am in the process of reverting the demod phases, etc. |
11068
|
Wed Feb 25 14:35:32 2015 |
Steve | Update | safety | safety audit 2015 | Safety audit went soothly. We thank all participients.
Correction list:
1, Bathroom water heater cable to be stress releived and connector replaced by twister lock type.
2, Floor cable bridge at the vacuum rack to be replaced. It is cracked.
3, Sprinkler head to be moved eastward 2 ft in room 101
4, Annual crane inspection is scheduled for 8am Marc 3, 2015
5, Annual safety glasses cleaning and transmission measurement will get done tomorrow morning. |
Attachment 1: safety2015audit.jpg
|
|
11067
|
Wed Feb 25 14:18:28 2015 |
rana | Update | LSC | Delay line re-installed, measurements round 2 | The Schnupp asymmetry is definitely not an important parameter (no need for Koji to explode). It only serves to give us a bigger Q phase signal slope, but is not significant for the I phase signals.
The main anomaly is that the REFL33 optical gain (W/m) seems to have been reduced so much by the phase and amplitude adjustment of the 55 MHz modulation signal. One guess is that the true 3f signal is being made not by the (2*f1 - (-f1)) beat, but by some higher order beat. In addition to the usual RF fields produced by the 2 modulations, we must consider that the sidebands on sidebands produce intermodulation fields just after the EOM and so the fields with which we interrogate the PRMI are more complicated.
Jenne's Optickle calculation today should show us what the sensing matrix contribution is from each pair of fields, so that we can have a sensing matrix signal budget.
|
11066
|
Wed Feb 25 12:16:27 2015 |
Koji | Update | LSC | Delay line re-installed, measurements round 2 | WHAT? WHAT? WHAT? It's obviously opposite.
If the reflectivity of the front mirror is fixed (=PRM reflectivity), the finesse increases when the reflectivity of the end
mirror (=Compond mirror reflectivity) increases. i.e. 11MHz has higher finesse, 55MHz has lower finesse.

If the reflectivity of the front mirror is fixed, the amplitude gain of the cavity is higher when the reflectivity of the end mirror increases. i.e. 11MHz has higher gain, 55MHz has lower gain

Quote: |
Our Schnupp asymmetry is small (3.9cm, IIRC), so the transmission of the 11MHz signal out the dark port is small. This means that the finesse of the PRC for 11MHz isn't so huge. On the other hand, since 55MHz is a higher frequency, the transmission out the dark port is larger and is a closer match to the PRM transmission, so the finesse of the PRC for 55MHz is higher.
|
|
11065
|
Wed Feb 25 11:01:05 2015 |
manasa | Update | Computer Scripts / Programs | New screen for FOL PID loop | Created a new medm screen C1ALS_FOL_PID.adl for FOL PID loop control in /medm/als/master/
This is not currently linked to the sitemap screen. |
11064
|
Wed Feb 25 04:59:47 2015 |
Jenne | Update | LSC | Delay line re-installed, measurements round 2 | [Jenne, EricQ, Rana]
We spent this evening measuring and thinking about our 3f signals, and the effect of the modulation cancellation.
I reinstalled the delay line box, and reduced the modulation depth of the 55MHz signal, so that we are in the state of modulation cancellation - there should be almost no power at 33MHz injected into the vacuum. I carefully tuned the demod phase of the REFL 11, 33 and 55 MHz PDs, and locked the PRMI on REFL55 I&Q. The signal in REFL 165 was very tiny, so as best as I could tell, the demod phase that Koji found last week was correct.
Here is a little record of what the demodulation phases should be, for the "nominal" and "cancellation" configurations, so that we don't have to continually use the time machine.
|
"Nominal" configuration |
3f modulation cancellation |
REFL 11 |
20 deg |
76.0 deg (tuned to nearest 0.5 deg) |
REFL 33 |
142.2 deg |
120.3 deg (tuned to nearest 0.1 deg) |
REFL 55 |
19 deg |
173.0 deg (tuned to nearest 0.5 deg) |
REFL 165 |
-172 deg |
18 deg (same number as last week) |
AS 55 |
-166.1 deg |
-111.1 deg (same number as last week) |
Also, here is the locking recipe for REFL55 I&Q in the cancellation configuration:
PRMI, 3f cancellation, REFL55 I&Q |
MICH |
PRCL |
Input Matrix |
acquire with -2*REFL55Q, then put matrix to -15*REFL55Q |
-12*REFL55I |
Gain |
3.0 |
-0.1 |
DoF trigger |
POP22I; 50 up, 0.5 down |
POP22I; 50 up, 0.5 down |
FMs |
FM 4, 5 on |
FM 4, 5 on |
FM trigger |
FM 1, 2, 3, 6, 9; 50 up, 0.5 down, 5 second wait |
FM 1, 2, 6, 9; 50 up, 0.5 down, 1 second wait |
Normalization |
none |
none |
Output matrix |
-1*ITMX, +1*ITMY |
1*PRM |
With this setup, we measured the sensing matrix. MICH had an excitation at 370.123 Hz with 8,000 counts to -ITMX+ITMY (this is about 0.3nm for each ITM), and PRCL had an excitation at 404.123 Hz with 50 counts to PRM. For tonight, here is a PDF of the peaks in DTT. The data is saved in /users/Templates/LSC_error_spectra/SensMat_PRMI_24Feb2015.xml.
SensMat_PRMI_24Feb2015.pdf
Rana has proposed to us an idea for why the REFL 33 signal should be dominated by the 55*22 contribution, rather than -11*22. Eric is in the process of checking this out with a Mist model to see if it makes sense. Here's the gist:
Our Schnupp asymmetry is small (3.9cm, IIRC), so the transmission of the 11MHz signal out the dark port is small. This means that the finesse of the PRC for 11MHz isn't so huge. On the other hand, since 55MHz is a higher frequency, the transmission out the dark port is larger and is a closer match to the PRM transmission, so the finesse of the PRC for 55MHz is higher.
Since the magnitudes of the fields at the reflection port are not changing significantly, our PDH signals are being created by the relative phase of something which is anti-resonant (ex. carrier or 22MHz for sideband lock) vs. something which is resonant (ex. 11MHz or 55MHz). Since the finesse of the 55MHz signal is larger, the accumulated phase change is greater, so we expect a larger slope to our PDH signals that involve 55MHz as compared to those that use 11MHz.
If we are comparing the contributions between -11*22 and 55*22, they both include the anti-resonant 22MHz. So, the difference in the signal strengths comes directly from the difference in phase accumulation due to the variation in the dark port transmission.
EricQ had a thought, and while I have enough awake brain cells to report the thought, we're going to have to revisit it when more of our brains are awake. In either case, the transmission through the dark port is small compared to the transmission of the ITMs, so why don't the ITMs dominate the finesse calculation, and thus are the 11MHz and 55MHz really getting that much of a difference in finesse? To be checked out. |
Attachment 1: SensMat_PRMI_24Feb2015.pdf
|
|
11063
|
Wed Feb 25 04:21:58 2015 |
ericq | Update | CDS | Some model updates | I changed the suspension library block to acquire the SUS_[optic]_LSC_OUT channels at 16k for sensing matrix investigations. We could save the FB some load by disabling these and oplev channels in the mode cleaner optic suspensions.
I removed nonexistant PDs from c1cal, to try and speed it up from its constantly overflowing state. It's still pretty bad, but under 60us most of the time.
I also cleaned out the unused IPCs for simulated plant stuff from c1scx and c1sus, to get rid of red blinkeys. |
11062
|
Tue Feb 24 23:39:16 2015 |
Jenne | Update | LSC | Delay line re-installed again | About 5-10 minutes ago I just put in the modulation cancellation setup according to the recipe in http://nodus.ligo.caltech.edu:8080/40m/11032 |
11061
|
Tue Feb 24 18:54:26 2015 |
ericq | Update | ASC | Single arm QPD ASC stability | I've lowered the UGFs for the transmission QPD servos to ~1-2Hz, and made it just an integrator. I left the arms locked with the QPD servos on for a few hours during the daytime today, and they succesfully prevented the Y arm from losing power from alignment drift for ~4 hours. Turning the servo off caused TRY to drop to ~0.6 or so.
The X arm was only held for 2 hours or so, because after some unlock/drift event the power was below the servo trigger threshold. However, after gently nudging ETMX to get the transmission above the threshold, the servo kicked in, and brought it right back to TRX=1.0
Unfortunately, daqd was dead for much of the day, so I don't have much data to show; the trend was inferred from the wall striptool.
It is not proven that there aren't further issues that prevent this from working with higher / more dynamic arm powers, but this is at least a point in favor of it working.
EDIT: Here's a screenshot of the wall StripTool. Brown is TRY, blue is TRX. The downturn at the very end is me deactivating the servos.

There is no scientific justifcation for the 0.9 threshold. Really, I should look at the noise/SNR again, now that there is some ND filtering on the QPDs. |
Attachment 1: trend.png
|
|
11060
|
Tue Feb 24 01:57:01 2015 |
Jenne | Update | LSC | Modelled effect of relative modulation phase | I have used Optickle to model the effect of changing the phase between the 11MHz and 55MHz EOMs. Also, I have looked at what modulation order is most significant (we hope it's -22*11 and -11*22).
First, so that we can compare these numbers more directly to measurements, I have included in the model the fraction of light that gets to each PD. I'm assuming that the Faraday is about 80% transmissive, but I don't know what the true number is. Here's a cartoon showing the attenuation factors.
EDIT, 26March2015, JCD: REFL path updated. See elog 11172.

To model the change in relative phase between the 11MHz and 55MHz modultions, I have held the 11MHz EOM stationary, and moved the 55MHz EOM. Since I needed an actual distance, I used a conversion factor,
![\frac{\rm m}{\rm deg} = \frac{360 \ \rm deg}{55 \ \rm MHz} (\rm speed \ of \ light \ [m/s])](http://latex.codecogs.com/gif.latex?%5Cfrac%7B%5Crm%20m%7D%7B%5Crm%20deg%7D%20%3D%20%5Cfrac%7B360%20%5C%20%5Crm%20deg%7D%7B55%20%5C%20%5Crm%20MHz%7D%20%28%5Crm%20speed%20%5C%20of%20%5C%20light%20%5C%20%5Bm/s%5D%29)
The sensing matrix was measured at 143Hz. It has been corrected from mevans-meters to Newtons as the denominator.

The big thing to notice here is that the PRCL magnitude is not changing by a factor of 20. More like a factor of 2. BUT, I have not yet included the fact that Koji also reduced the 55MHz modulation amplitude by a factor of 3.
As for the mysterious degeneracy of all the REFL PDs, I think we need to take a more careful measurement. It's possible that we were seeing the real thing for REFL33, but the others don't seem to change in degeneracy with relative modulation phase.

Why does it even matter for the 3*f1 signal what is going on with the f2 modulation? Well, it appears that we are definitely being dominated by the 44*11 and 55*22 components.
To check this, I restricted Optickle to various orders of modulation (ex. up to second order only includes the [-22, -11, 0, 11, 22] MHz components), and plotted them all. The change in the signal between one trace and another is the contribution from that extra modulation order. The traces are only minutely different between orders, after the 5th order. So, since they're all overlapping with the 5th order trace anyway, I don't plot them.


EDIT: to clarify, when I said "up to X order", I meant up to that order in 11MHz sidebands. Optickle is applying the 11MHz and 55MHz modulations in the same way every time, but then I specify up to what order to include in the summation of different contributions to the field at a given port. So, for the "up to 2nd order", I only include cross terms that come from [-22, -11, 0, 11, 22] MHz. For the next order, I only include terms that come from [-33, -22, -11, 0, 11, 22, 33] MHz, etc. So, there are no 55MHz effects when I'm only including contributions up to 2nd order (since there is a maximum cross beatnote of 44MHz), but starting with 3rd order, I do start to see signals in, for example, REFL55 and AS55, since I get terms from -22*33 and -33*22. The first order in 55MHz (i.e. 55MHz*Carrier) only starts to show up when I calculate "up to 5th order" and above, since that includes [-55, -44, -33, -22, -11, 0, 11, 22, 33, 44, 55] MHz.
What happens if I reduce the 55MHz modulation depth by 10dB? Since we are dominated by 55MHz-related signals, the signal at REFL 33 goes down. The maximum change we could have seen for the REFL33 PRCL signal (difference between max of blue trace and min of orange trace) is a factor of 27.


Where are we on the x-axis of these plots, and where was the maximal cancellation place that Koji found? I need to re-check that part of the code tomorrow, to make sure that I've included all of my contributions from different components of the (field* field) matrix.
But, the moral of the story for tonight is that at least for the REFL33 signal, it's actually plausible that the optical gain went down by a factor of 20, and that the MICH and PRCL signals were degenerate. I suspect that the total cancellation place that Koji found was somewhere around 175 degrees on the x-axis of these plots and that our nominal place is around 0 deg - around there, both the magnitude and the phase situations are possible simultaneously. |
Attachment 1: ChangeInAngle_PRCLvsMICH.png
|
|
Attachment 2: REFL33_MICH_SensMat_vsModulationOrder_vsModulationPhase.png
|
|
Attachment 3: REFL33_SensMat_vsModulationPhase.png
|
|
Attachment 4: REFL33_PRCL_nominalVsLoweredGamma.png
|
|
Attachment 5: REFL33_MICH_nominalVsLoweredGamma.png
|
|
11059
|
Mon Feb 23 21:57:13 2015 |
Koji | Update | LSC | Delay line installed again (experiment, round 1) | Last Wednesday we tried PRMI 3f modulation cancellation. Under the 3f modulation cancellation, the PRMI could not be locked
with REFL signals, and the PRCL signal was just barely sufficient to lock PRCL with help of AS55Q MICH.
- The PRCL signal level in REFL33 was reduced by factor of 20 compared with the conventional modulation setting.
=> The 3f modulation cancellation does not chage the level of 11/22MHz sidebands, it is expected that REFL33 signal
has no significant change of the signal level. But it does. If we change the relative phase between the modulations
at 11 and 55MHz, the signal level is recovered by factor of 5. Therefore something related to 55MHz modulation
(55MHz x 22MHz, or 44MHz x 11MHz) was contributing more than -11MHzx22MHz.
- Under the 3f demodulation cancellation, MICH signal in the REFL ports were extremely weak and there was
no hope to use it for any feedback control.
- WIth the PRMI locking by REFL33->PRCL and AS55Q->MICH, the sensing matrix was measured. All of the REFL
ports however, showed extremely degenerate sensing matrix between MICH and PRCL.
This was enough confusing to us, and we didn't draw any useful information from these. Here are some ideas to
investigate what is happening in out optical and electrical system.
- One approach is to use as simple optical setup as possible to inspect our sensing systems. For example,
we may want to try PRX/PRY/XARM/YARM cavities to check the functions of the REFL diodes and qualitatively characterize
the sensing chain (Optical gain [W/m], noise level, demodulation phase) so that we can compare these with
an interferometer seinsing model.
- Another approach is to change the mdulation setting more freely and empirically try to find the characteristic
of our optical/electrical systems. e.g. change the relative modulation phase and/or 55MHz attenuation, and try to understand
how 11-22, 11-44, 22-55, 0-33 pairs are contributing the signal. |
11058
|
Mon Feb 23 15:04:10 2015 |
Zach | Update | General | Elog restarted | The elog crashed while I was creating an entry to the Cryo log. I restarted it with the start-elog.csh script. |
11057
|
Mon Feb 23 08:06:59 2015 |
rana | Update | ASC | QPD frontend code unified | Might have to also get the OL screens that go with this new code to see, but the calibrations don't go into the matrix, but rather into the OLPIT/OLYAW filter banks which follow the division, but before the servo filter banks. |
11056
|
Fri Feb 20 19:09:48 2015 |
ericq | Update | ASC | QPD frontend code unified | I have changed all of the oplevs and transmon QPDs to use the common ISC QPD library block, which differs mainly in its divide by zero protection.
c1scx.mdl and c1scy.mdl were directly changed for the transmon QPDs. The oplevs were done by changing the sus_single_control.mdl library part, which is used for all of the SOSs.
Then, because of the underscore introduced (i.e. OLPIT becomes OL_PIT because there is an OL block), I went on a sed safari to find and replace the new channel names into:
- The filter ini files
- various MEDM screens
- The optic misaligning scripts (which currently live in
medm/MISC/ifoalign , and need to get moved to scripts/ )
- A recent BURT snapshot, to restore all of the switches and settings easily.
scripts/activateDQ.py , which is responsible for renaming OL_PIT_IN1_DQ to OPLEV_PERROR, etc.
I've fixed everything that occured to me, and the usual ways I'm used to interacting with the oplevs all seem to work at this time, but it's entirely possible I've overlooked something.
One important note is: because we are now using an effectively immutable QPD library block, the oplev urad conversion has to take place in the DoF matrix. The EPICS records C1:SUS-[OPTIC]_OL_[DOF]_CALIB still exist, but do not multiply the fast signals. Rather, the OL_MTRX elements are multiples of the CALIB value. I thought about making a new QPD_CALIBRATED part or something, but then we're right back to using custom code, which is what we're trying to avoid.
All of the oplev DoFs are stable, I checked a few loop TFs like ETMY pitch and PRM yaw, and they looked normal. |
11055
|
Fri Feb 20 14:44:47 2015 |
ericq | Update | CDS | Bad CDS behavior | In an effort to ease the IO load on the framebuilder, I've cleaned up the DQ channels being written to disk. The biggest impact was seven 64kHz channels being written to disk, on ADC channels corresponding to microphones.
The frame files have gone from 75MB to 57MB. |
11054
|
Fri Feb 20 12:29:01 2015 |
ericq | Update | CDS | All optics damped | I noticed some diagnostic bits in the c1sus IOP complaining about user application timing and FIFO under/overflow (The second and fourth squares next to the DACs on the GDS screen.) Over in crackle-cymac land, I've seen this correlate with large excess DAC noise. After restarting all models, all but one of these is green again, and the optics are now all damped.
It seems there were some fishy BURT restores, as I found the TT control filters had their inputs and outputs switched off. Some ASS filters were found this way too. More undesired settings may still lurk in the mists...
The interferometer is now realigned, arms locked. |
11053
|
Fri Feb 20 12:08:10 2015 |
ericq | Update | CDS | Bad CDS behavior | I've been able to get all models running. Most optics are damped, but I'm having trouble with the ITMs, BS and PRM. |
11052
|
Thu Feb 19 23:23:52 2015 |
Chris | Update | CDS | Bad CDS behavior | The frontends have some paths NFS-mounted from fb. fb is on the ragged edge of being I/O bound. I'd suggest moving those mounts to chiara. I tried increasing the number of NFS threads on fb (undoing the configuration change I'd previously made here) and it seems to help with EPICS smoothness -- although there are still occasional temporal anomalies in the time channels. The daqd flakiness (which was what led me to throttle NFS on fb in the first place) may now recur as well.
Quote: |
At about 10AM, the C1LSC frontend stopped reporting any EPICS information. The arms were locked at the time, and remained so for some hours, until I noticed the totally whited-out MEDM screens. The machine would respond to pings, but did not respond to ssh, so we had to manually reboot.
Soon thereafter, we had a global 15min EPICS freeze, and have been in a weird state ever since. Epics has come back (and frozen again), but the fast frontends are still wonky, even when EPICS is not frozen. Intermittantly, the status blinkers and GPS time EPICS values will freeze for multiple seconds at a time, sporadically updating. Looking at a StripTool trace of an IOPs GPS time value shows a line with smooth portions for about 30 seconds, about 2 minutes apart. Between this is totally jagged step function behavior. C1LSC needed to be power cycled again; trying to restart the models is tough, because the EPICS slowdown makes it hard to hit the BURT button, as is needed for the model to start without crashing.
The DAQ network switch, and martian switch inside were power cycled, to little effect. I'm not sure how to diagnose network issues with the frontends. Using iperf, I am able to show hundreds of Mbit/s bandwidth betweem the control room machines and the frontends, but their EPICS is still totally wonky.
What can we do??? 
|
|
11051
|
Thu Feb 19 15:45:43 2015 |
ericq | Update | CDS | Bad CDS behavior | At about 10AM, the C1LSC frontend stopped reporting any EPICS information. The arms were locked at the time, and remained so for some hours, until I noticed the totally whited-out MEDM screens. The machine would respond to pings, but did not respond to ssh, so we had to manually reboot.
Soon thereafter, we had a global 15min EPICS freeze, and have been in a weird state ever since. Epics has come back (and frozen again), but the fast frontends are still wonky, even when EPICS is not frozen. Intermittantly, the status blinkers and GPS time EPICS values will freeze for multiple seconds at a time, sporadically updating. Looking at a StripTool trace of an IOPs GPS time value shows a line with smooth portions for about 30 seconds, about 2 minutes apart. Between this is totally jagged step function behavior. C1LSC needed to be power cycled again; trying to restart the models is tough, because the EPICS slowdown makes it hard to hit the BURT button, as is needed for the model to start without crashing.
The DAQ network switch, and martian switch inside were power cycled, to little effect. I'm not sure how to diagnose network issues with the frontends. Using iperf, I am able to show hundreds of Mbit/s bandwidth betweem the control room machines and the frontends, but their EPICS is still totally wonky.
What can we do???  |
11050
|
Thu Feb 19 04:16:45 2015 |
Jenne | Update | LSC | ALS fool attempt with PRFPMI | [Jenne, EricQ]
We tried several times tonight to engage the Fool path with the PRFPMI. No success.
First, we locked the arms on ALS, in CARM/DARM mode, and measured the cancellation ability, to make sure that the filter shape and gain was set correctly. For the PRFPMI, it was okay using the same shape as the single arm case, but the gain was +20.0. There might be a bit more cancellation to be gained if we adjust the shape at the ~1dB level, but we're already able to get 20dB of cancellation, so we decided that would be enough to give things a try. To get this much cancellation, we set the phase tracker loops to both have 2kHz UGFs, almost exactly. We should implement a UGF servo, or the amplitude method version of that as Koji suggested ages ago, so that the phase tracker is always at the same place.

I don't think that REFL 11 is seeing as much CARM as I expect. We ended up switching over to linearized REFL55 for our attempts. When we're close to zero CARM offset, the arms are constantly flashing through resonance, and we get the loud buzzing. REFL11 doesn't seem to see any of this, even though we should be close enough to see some PDH action. REFL55 does change as we get closer to resonance, so I think it's seeing some real CARM stuff.
We tried engaging the Fool, but I don't think it did anything too useful. We need to make an estimate of what we expect our gain of the REFL loop to be - or at least the sign.
The PRMI is still not stable enough. It keeps falling out of lock when we get to high-ish arm powers. Not good. More brain power tomorrow on the modulation cancellation issue.
Perhaps if things are stable at moderate arm powers, we can use an excitation to line up the ALS vs. REFL error signals, and then watch the noises of them change as we move around in CARM offset. This should tell us when the linearized REFL signal is quiet enough that it's worth triggering and trying to transfer over.
The last lockloss tonight, there was something funny going on, that we can't explain. Even though both arms were locked on the CARM/DARM combined ALS signals, beatx doesn't see the giant oscillation that causes carm to lose lock until much later. Fool was trying to do something, but that should affect both als individal signals in the same way. Mystery.

|
Attachment 1: BEATYcrazy_duringCARMdarmLock_18Feb2015.png
|
|
Attachment 2: 19Feb.png
|
|
11049
|
Thu Feb 19 04:09:21 2015 |
ericq | Update | Electronics | Second QPD Whitening Switch enabled | X end QPD has recieved 0.2+0.4 absorptive ND filters. Y end QPD got one at 0.6. This appears to have mitigated the saturations for now; the unwhitened signals no longer go negative. The digital gains have been reset.
|
11048
|
Wed Feb 18 19:06:40 2015 |
Koji | Update | LSC | ALS Fool impulse response | 
|
11047
|
Wed Feb 18 17:51:40 2015 |
ericq | Update | LSC | ALS Fool impulse response | Koji raised a good question about the step response I wrote about. Namely, if the UGF of the ALS servo is around 100Hz, we would expect it to settle with a characteristic time on the order of tens of milliseconds, not seconds, as was seen in the plot I posted.
I claim that the reason for the slow response was the fact that the feedforward FM stayed on after the kick, despite the MC filter bank being triggered off. Since it has filters that look like a oscillator at 1Hz, the ringdown or exponential decay of this filter's output in response to the large impulsive output of the PDH control signal just before being triggered down would slowly push the ALS error signal around through the feedforward path.
Given this reasoning, this should be helped by adding output triggering to the FF filter that uses the MC trigger matrix row, as I wanted to do anyways. I have now added this into the LSC model (as well as DQ at 2kHz for the MC_CTRL_FF_OUT), and the impulse response is indeed much quicker.
In the following plot, I hit ETMY with a five sample, 5000 amplitude, impulse (rather than a step, as I did yesterday). The system comes back to PDH lock after ~40ms.

|
Attachment 1: ALSfool_fasterKick.png
|
|
11046
|
Wed Feb 18 01:58:51 2015 |
ericq | Update | LSC | ALS Fool single arm performance | I'm playing around with the lastest ALS fool feedforward on the Yarm, and I like what I'm seeing.
First, I verified that I could reproduce the TF shapes in ELOG 11041, which I was able to do with a gain of +9.3 and FMs 5 and 6 in the FF module.
Then, I locked the arm on ALS with full bandwidth, and on POY with the settings currently used the MC module, and took their spectra as references. (I put an excitation on the arm at 443Hz to line them up to the same arbitrary units.)
Then, with ALS at its usual 100Hz UGF and boosts on, the Fool path on, and the MC FM set to trigger on/off at 0.8/0.5, I slowly brought ALS towards zero offset and saw it pop right into resonance. I then manually triggered the PDH boosts.
Here are some spectra, showing that, with the Fool path on:
- POY unsurprisingly picks up the high frequency noise of the ALS. (Could be mitigated by judicious lowpassing?)
- The in-fool-loop POY noise is WAY more supressed at low frequencies, so the loops are definitely working together. RMS is about 2x smaller too.

Once the PDH loop is running, the ALS loop can be switched out at the CARM FM output without much of an effect beyond a small kick.
However, looking at the loop shapes, maybe I got lucky here. I took the usual injection TFs at the MC FM, the CARM FM, and at ETMY, to get the overall OLG; all of them have >0.9 coherence pretty much everywhere except the first two points.
As desired, the PDH loop looks pretty normal.
I have no intuition about how the fooled CARM loop should look, since this is even more complicated than a two-loop system.
I don't currently know what is causing the odd feature in the overall at ~50Hz, and it spooked me out when I saw the multiple UGF crossings. The only thing I could think of happening there is the pole in the ALS phase tracker boost. I turned it off, and remeasured; the feature persists...

To wrap it up, here's something I think is pretty cool. Here's what happens when I give ETMY a 1000 count position step impulse (no ramp). [Here, CARM is on ALS with G=12, but only FM5 on]

Although the arm was controlled with IR before the kick, ALS maintained control. As soon as ALS brought the arm back towards resonance, the PDH loop picked it right back up.
Coooool.
Some random notes:
- We should really DQ the output of the feedforward FM. I'll try to remember to do this tonight
- I was having problems with the zero crossing triggering, so I didn't end up using it, desipte trying to. Maybe we should implement the Schmitt-y style of "Am I below the threshold? Wait. Am I closer to zero now? Ok, Go!"
- The 1Hz pole in the FF FM rings, unsurprisingly, when the MC FM triggers on briefly, which can be a pain. I made a FM4 which is a Q=1 (instead of 7) pole pair for less ringy. This probably hurts the cancellation somewhat, but I was impatient.
- Alternatively, we could try to figure out how to force history clear when the MC filter is triggered off.
DTT data is attached, in case it's useful to anyone! |
Attachment 1: ALSfool_spectra.png
|
|
Attachment 2: ALSfool_kick.png
|
|
Attachment 3: ALSfool_LoopShapes.png
|
|
Attachment 4: ALSfool_Feb182015.zip
|
11045
|
Tue Feb 17 19:49:51 2015 |
Koji | Update | LSC | Delay line un-installed again | The modulation setting was reverted.
Demod phase for REFL11/33/55/165 and AS55 were reverted to the previous numbers too. |
11044
|
Tue Feb 17 16:44:04 2015 |
Koji | Update | LSC | Delay line installed again | For tonight's experiment, I re-installed the delay line cable and changed the attenuation to 10dB for the 55MHz modulation.
I quickly locked the PLL and checked that the modulation is the ratio of the field strength between the worst (19ns) and best
case (28ns) is 31dB, that is ~35 times reduction. |
11043
|
Tue Feb 17 16:36:08 2015 |
Jenne | Update | LSC | ALS fool math | Here is an updated cartoon, with the ALS sensor explicitly shown as the beatbox times the closed loop response of the phase tracker servo.
The most important transfer functions are written on the diagram. Others can be extracted from the attached Mathematica file (which corresponds to this diagram).

|
Attachment 1: ALSfool_LoopDiagram_17Feb2015.png
|
|
Attachment 2: ALS_REFL_comboLocking_16Feb2015.nb.zip
|
11042
|
Tue Feb 17 04:04:32 2015 |
Jenne | Update | LSC | ALS fool math | I re-did the Mathematica notebook according to the most current diagram (note to daytime self: attach .nb file!!!), and found that the denominator has changed, such that plugging in the new D=-A_refl*P_als*S_als gives the same
full-system closed loop gain of 
where is the open loop gain, and the * indicates either the REFL or ALS portions of the system.
I have also plotted some things with Matlab, although I'm a little confused, and my daytime self needs to spend some more time thinking about this.
In the actuators (both for REFL and ALS), I include a pendulum, the digital anti-imaging filters that let us go from the 16kHz model to the 64kHz IOP and the analog anti-imaging filters after the DAC. Note to self: still need to include violin filters here.
For the servo gains, I copy the filters that we are using from Foton, and give them the same overall gain multiplier that is in the filter bank. For the ALS going through the CARM filter bank, this is FMs 1, 2, 3, 5, 6 with a gain of 15. For the RF (actually, POY here) going through the MC filter bank, this is FMs 4, 5, 7 with a gain of 0.08.
For the plants of each system, since this is still single arm lock, I just include a cavity pole (80kHz for ALS, 18kHz for REFL).
In the sensors (both for REFL and ALS), I include the analog anti-aliasing as well as the digital anti-aliasing to allow us to go from the 64kHz IOP to the 16kHz front end system. For the ALS I also include in the sensor the closed loop response of the phase tracker loop (H/(1-H), where H is the open loop gain of the phase tracker). For both sensors, I also include a semi-arbitrary number to make the full single-loop open loop gain have a UGF of 200Hz. In the ALS sensor, I also include a minus sign to make the full open loop gain have the correct phase.
Here I plot the open loop gains of the individual single loops, as well as the open loop gain of the full system (Hals + Hrefl - Hals*Hrefl). I feel like I must be missing a minus sign in my ALS loop, but I don't know where, and my nighttime brain doesn't want to just throw in minus signs without knowing why. That will affect how the final ALSfool (blue trace) looks, so maybe it's not really as crazy as it looks right now.

Also, I was trying to explain to myself why we are getting the shape that we are in our measurements of the cancellation (http://nodus.ligo.caltech.edu:8080/40m/11041). But, I can't. Below are the plots of the transfer functions from either point 9 or 10 (before or after the G_refl) to point 5, which is the ALS error point. The measurement in elog 11041 should correspond to the blue trace here. For these traces, the decoupling is set to just (-A_refl), although there aren't any noticeable changes in the shape if I just set D=0. If we start with the assumption that D=0, the shape and magnitude are basically identical to this plot, and then as we make D=-A_refl P_als S_als, the transfer functions both go to zero.
So. Why is it that with no decoupling, the transfer function from 10 to 5 is tiny? Why do the shapes plotted below look nothing at all like the measured cancellation shape? Daytime brain needs to think some more.

|
Attachment 1: OpenLoopGainComparison_16Feb2015.png
|
|
Attachment 2: CancellationTFs_DecouplingIsArefl.png
|
|
11041
|
Tue Feb 17 00:24:47 2015 |
rana, jenne | Update | LSC | ALS Fool filter updated for more cancellation | Today we measured the TFs again and then updated the filter in the POY -> ALS FF path so as to get 10x better cancellation.

The cancellation went from ~10 dB to ~30 dB. This seems good enough. The new filter 'Comp1' is just constructed by eye. We then had to tune the filter module gain to a few %. Seems good enough for now, but we should really try to understand what it is and why it is the way that it is. In the above plot, the ORANGE trace is the old cancellation and the GREEN one is the new one. The filter TF is attached below - its not special, we made it by presing buttons in FOTON until the TF matched the measured TF of ALSY/LSC-MC_CTRL_FF_OUT.

|
Attachment 1: ALSfoo_150216.png
|
|
Attachment 2: 15.png
|
|
11040
|
Mon Feb 16 21:52:51 2015 |
rana | HowTo | Treasure | big Dataviewer windows | Following this entry, I have made the same change in the controls account on rossa:
In the ~/.grace/gracerc file (create one if it doesn't exist), put in a line which reads:
PAGE LAYOUT FREE
Now we can scale our dataviewer live and playback plots by stretching the window with our mouse. The attached screenshot shows how I filled up one of the vertical monitors with a DV window for arm locking. |
Attachment 1: bigDV.png
|
|
11039
|
Mon Feb 16 15:08:26 2015 |
Jenne | Update | LSC | ALS fool measured decoupling TF | Dang it, yes. You're right. I should have caught that.
Since Dcpl and Srefl are both zero during the measurement (since it was an ALS lock), this is actually

So, I need to remove the effect of the ALS closed loop, to get the actual quantity I was looking for. |
11038
|
Mon Feb 16 03:10:42 2015 |
Koji | Update | LSC | ALS fool measured decoupling TF | Wonkey shape: Looks like a loop supression. Your http://nodus.ligo.caltech.edu:8080/40m/11016 also suggests it too, doesn't it? |
11037
|
Mon Feb 16 02:49:57 2015 |
Jenne | Update | LSC | ALS fool measured decoupling TF | I have measured very, very carefully the transfer function from pushing on MC2 to the Yarm ALS beatnote. In the newest loop diagram in http://nodus.ligo.caltech.edu:8080/40m/11030, this is pushing at point 10 and sensing at point 4.
Since it's a bunch of different transfer functions (to get the high coherence that we need for good cancellation to be possible), I attach my Matlab figure that includes only the useful data points. I put a coherence cutoff of 0.99, so that (assuming the fit were perfect, which it won't be), we would be able to get a maximum cancellation of a factor of 100.
This plot also includes the vectfit to the data, which you can see is pretty good, although I need to separately plot the residuals (since the magnitude data is so small, the residuals for the mag don't show up in the auto plot that vectfit gives).

If you recall from http://nodus.ligo.caltech.edu:8080/40m/11020, we are expecting this transfer function to consist of the suspension actuator (pendulum with complex pole pair around 1Hz), the ALS plant (single pole at 80kHz) and the ALS sensor shape (the phase tracker is an integrator, with a boost consisting of a zero at 666Hz and a pole at 55Hz). That expected transfer function does not multiply up to give me this wonky shape. Brain power is needed here.
Just in case you were wondering if this depends on the actuator used (ETM vs MC2), or IFO configuration (single arm vs. PRFPMI), it doesn't. The only discrepancy between these transfer functions is the expected sign flip between the MC2 and ETMY actuators. So, they're all pretty consistent.
Before locking the PRFPMI, I copied the boost filter (666:55) from the YARM ALS over to Xarm ALS, so now both arms have the same boost.
YARM_actTF_compareActuators.pdf
Things to do for ALSfool:
- Put fitted TF into the MC_CTRL_FF filter bank, and try to measure the expected cancellation, a la http://nodus.ligo.caltech.edu:8080/40m/11009
- Quick test with single arm, ALS locked using full loop (high gain, all boosts), since the previous versions were with ALS very loosely locked.
- Does this measured transfer function actually give us good cancellation?
- Think. Why should the transfer function look like this??
- Try it on the full PRFPMI
|
Attachment 1: ALSfool_measuredActuatorTF_YarmOnly_15Feb2015.png
|
|
Attachment 2: YARM_actTF_compareActuators.pdf
|
|
11036
|
Mon Feb 16 01:45:12 2015 |
Koji | Summary | LSC | modulation depth analysis | Based on the measured modulation profiles, the depth of each modulation was estimated.
Least square sum minimization of the relative error was used for the cost function.
-8th, -12th~-14th, n=>7th are not included in the estimation for the nominal case.
-7th~-9th, -11th~-15th, n=>7th are not included in the estimation for the 3f reduced case.
Nominal modulation
m_f1 = 0.194
m_f2 = 0.234
theta_f1f2 = 41.35deg
m_IMC = 0.00153
3f reduced modulation
m_f1 = 0.191
m_f2 = 0.0579
theta_f1f2 = 180deg
m_IMC = 0.00149
(Sorry! There is no error bars. The data have too few statistics...) |
Attachment 1: modulation_nominal.pdf
|
|
Attachment 2: modulation_3f_reduced.pdf
|
|
11035
|
Mon Feb 16 00:08:44 2015 |
Koji | Summary | LSC | [ELOG LIST] 3f modulation cancellation | This KTP crystal has the maximum allowed RF power of 10W (=32Vpk) and V_pi = 230V. This corresponds to the maximum allowed
modulation depth of 32*Pi/230 = 0.44. So we probably can achieve gamma_1 of ~0.4 and gamma_2 of ~0.13. That's not x3 but x2,
so sounds not too bad.
Then Kiwamu's triple resonant circuit LIGO-G1000297-v1 actually shows the modulation up to ~0.7. Therefore it is purely an issue
how to deliver sufficient modulation power. (In fact his measurement shows some nonlinearity above the modulation depth of ~0.4
so we should keep the maximum power consumption of 10W at the crystal)
This means that we need to review our RF system (again!)
- Review infamous crazy attn/amp combinations in the frequency generation box.
- Use Teledyne Cougar ampilfier (A2CP2596) right before the triple resonant box. This should be installed closely to the triple resonant box in order to
minimize the effects of the reflection due to imperferct impedance matching.
- Review and refine the triple resonant circuit - it's not built on a PCB but on a universal board. I think that we don't need triple
resonance, but double is OK as the 29.5MHz signal is small.
We want +28V supply at 1X1 for the Teledyne amp and the AOM driver. Do we have any unused Sorensen? |
11034
|
Sun Feb 15 20:55:48 2015 |
rana | Summary | LSC | [ELOG LIST] 3f modulation cancellation | I wonder if DRMI can be locked on 3f using this lower 55 MHz modulation depth. It seems that PRMI should be unaffected, but that the 3*f2 signals for SRCL will be too puny. Is it really possible to scale up the overall modulation depths by 3x to compensate for this? |
11033
|
Sun Feb 15 16:20:44 2015 |
Koji | Summary | LSC | [ELOG LIST] 3f modulation cancellation | Summary of the ELOGS
3f modulation cancellation theory http://nodus.ligo.caltech.edu:8080/40m/11005
3f modulation cancellation adjustment setup http://nodus.ligo.caltech.edu:8080/40m/11029
Experiment http://nodus.ligo.caltech.edu:8080/40m/11031
Receipe for the 3f modulation cancellation http://nodus.ligo.caltech.edu:8080/40m/11032
Modulation depth analysis http://nodus.ligo.caltech.edu:8080/40m/11036 |
11032
|
Sat Feb 14 22:14:02 2015 |
Koji | Summary | LSC | [HOW TO] 3f modulation cancellation | When I finished my measurements, the modulation setup was reverted to the conventional one.
If someone wants to use the 3f cancellation setting, it can be done along with this HOW-TO.
The 3f cancellation can be realized by adding a carefully adjusted delay line and attenuation for the 55MHz modulation
on the frequency generation box at the 1X2 rack. Here is the procedure:
1) Turn off the frequency generation box
There is a toggle switch at the rear of the unit. It's better to turn it off before any cable action.
The outputs of the frequency generation box are high in general. We don't want to operate
the amplifiers without proper impedance matching in any occasion.
2) Remove the small SMA cable between 55MHz out and 55MHz in (Left arrow in the attachment 1).
According to the photo by Alberto (svn: /docs/upgrade08/RFsystem/frequencyGenerationBox/photos/DSC_2410.JPG),
this 55MHz out is the output of the frequency multiplier. The 55MHz in is the input for the amplifier stages.
Therefore, the cable length between these two connectors changes the relative phase between the modulations at 11MHz and 55MHz.
3) Add a delay line box with cables (Attachment 2).
Connect the cables from the delay line box to the 55MHz in/out connectors. I used 1.5m BNC cables.
The delay line box was set to have 28ns delay.
4) Set the attenuation of the 55MHz EOM drive (Right arrow in the attachment 1) to be 10dB.
Rotate the attenuation for 55MHz EOM from 0dB nominal to 10dB.
5) Turn on the frequency modulation box
For reference, the 3rd attachment shows the characteristics of the delay line cable/box combo when the 3f modualtion reduction
was realized. It had 1.37dB attenuation and +124deg phase shift. This phase change corresponds to the time delay of 48ns.
Note that the response of a short cable used for the measurement has been calibrated out using the CAL function of the network analyzer. |
Attachment 1: freq_gen_box.JPG
|
|
Attachment 2: delay_line.JPG
|
|
Attachment 3: cable_spec.pdf
|
|
11031
|
Sat Feb 14 20:37:51 2015 |
Koji | Summary | LSC | 3f modulation cancellation | Experimental results
- PD response [Attachment 1]
The AUX laser temperature was swept along with the note by Annalisa [http://nodus.ligo.caltech.edu:8080/40m/8369]
It is easier to observe the beat note by closing the PSL shutter as the MC locking yields more fluctuation of the PSL
laser freuqency at low frequency. Once I got the beat note and maximized it, I immediately noticed that the PD response
is not flat. For the next trial, we should use Newfocus 1611. For the measurement today, I decided to characterize the
response by sweeping the beat frequency and use the MAXHOLD function of the spectrum analyzer.
The measured and modelled response of the PD are shown in the attachment 1. It has non-intuitive shape.
Therefore the response is first modelled by two complex pole pair at 127.5MHz with Q of 1, and then the residual was
empirically fitted with 29th polynomial of f.
- Modulation profile of the nominal setting [Attachment 2]
Now the spectrum of the PD output was measured. This is a stiched data of the spectrum between 1~101MHz and 99~199MHz
that was almost simultaneously measured (i.e. Display 1 and Display 2). The IF bandwidth was 1kHz. The PD response correction
described above was applied.
It obviously had the peaks associated with our main modulations. In addition, there are more peaks seen.
The attachment 2 breaks down what is causing the peaks.
- Carrier: The PLL LO frequency is 95MHz. Therefore the carrier is locked at 95MHz.
- Modulation sidebands (11/55MHz series):
Series of sidebands are seen at the both side of the carrier. Their frequency is 95MHz +/- n * fmod (fmod = 11.066128MHz).
Note that the sidebands for n>10 were above 200MHz, and n<-9 (indicated in gray) were folded at 0Hz.
With this measurement BW, the following sidebands were buried in the noise floor.
n = -8, -12, -13, and -14, n<= -16, and n>=+7
- Modulation sidebands for IMC and PMC (29.5MHz and 35.5MHz):
First order sidebands for the IMC and PMC modulations of sidebands are seen at the both side of the carrier.
Their frequency is 95MHz +/- 29.5MHz or 33.5MHz. The PMC modulation sidebands are supposed to be blocked
by the PMC. However, due to finite finesse of the PMC, small fraction of the PMC sidebands are transmitted.
In deed, it is comparable to the modulation depth of the IMC one.
- RF AM or RF EMI for the main modulation and the IMC modulationand:
If there is residual RF AM in the PSL beam associated with the IMC and main modulations, it appears as the
peaks at the modulation frequency and its harmonics. Also EM radiation couples into this measument RF system
also appears at these frequencies. They are seen at n * fmod (n=1,2,4,5) and 29.5MHz.
- Reflection/distortion or leakage from mixer IF to RF:
The IF port of the mixer naturally has 190MHz signal when the PLL is locked. If the isolation from the IF port to the RF port
is not enough, this signal can appear in the RF monitor signal via an imperfection of the coupler or a reflection from the PD.
Also, if the reflecrtion/distortion exist between the PD and the mixer RF input, it also cause the signal around 190MHz.
It is seen at 190MHz +/- n* fmod. In the plot, the peak at n=0, -1 are visible. In fact these peak were secondarily dominant
in the spectrum when there was no 6dB attenuation in the PD line. WIth the attenuator, they are well damped and don't disturb
the main measurment.
From the measured peak height, we are able to estimate the modulation depths for 11MHz, 55MHz, IMC modulations, as well as
the relative phase of the 11MHz and 55MHz modulation. (It is not yet done).
- 3f modulation reduction [Attachment 3]
Now, the redcution of the 3f modulation was tried. The measured modulation levels for the 11MHz and 55MHz were almost the same.
The calculation predicts that the modulation for the 55MHz needs to be 1/3 of the 11MHz one. Therefore the attenuation of 9dB and 10dB
of the modulation attenuation knob at the frequency generation box were tried.
To give the variable delay time in the 55MHz line, EG&G ORTEC delay line unit was used. This allows us to change the delay time from
0ns to 63.5ns with the resolution of 0.5ns. The frequency of 55MHz yields a phase sensitivity of ~20deg/ns (360deg/18ns).
Therefore we can adjust the phase with the precision of 10deg over 1275deg.
The 3rd-order peak at 61.8MHz was observed with measurement span of 1kHz with very narrow BW like 30Hz(? not so sure). The delay
time was swept while measuring the peak height each time. For both the atteuation, the peak height clearly showed the repeatitive dependence
with the period of 18ns, and the 10dB case gave the better result. The difference between the best (1.24e-7 Vpk) and the worst (2.63e-6 Vpk)
was more than a factor of 20. The 3rd-order peak in the above broadband spectrum measurement was 6.38e-6 Vpk. Considering the attenuation
of the 55MHz modulation by 10dB, we were at the exact unluck phase difference. The improvement expected from the 3f reduction (in the 33MHz signal)
will be about 50, assuming there is no other coupling mechanism from CARM to REFL33.
I decided to declare the best setting is "10dB attenuation & 28ns delay".
- Resulting modulation profile [Attachment 4]
As a confirmation, the modulation profie was measured as done before the adjustment.
It is clear that the 3rd-order modulation was buried in the floor noise. 10dB attenuation of the 55MHz modulation yields corresponding reduction of the sidebands.
This will impact the signal quality for the 55MHz series error signals, particularly 165MHz ones. We should consider to install the Teledyne Cougar amplifier
next to the EOM so that we can increase the over all modulation depth. |
Attachment 1: beat_pd_response.pdf
|
|
Attachment 2: beat_nominal.pdf
|
|
Attachment 3: 3f_reduction.pdf
|
|
Attachment 4: beat_3f_reduced.pdf
|
|
11030
|
Sat Feb 14 20:20:24 2015 |
Jenne | Update | LSC | ALS fool cartoon | The ALS fool scheme is now diagrammed up in OmniGraffle, including its new official icon. The mathematica notebook has not yet been updated.

EDIT, JCD, 17Feb2015: Updated cartoon and calculation: http://131.215.115.52:8080/40m/11043
|
Attachment 1: ALSfool_LoopDiagram.png
|
|
Attachment 2: ALSfool_LoopDiagram.graffle.zip
|
|