ID |
Date |
Author |
Type |
Category |
Subject |
10404
|
Fri Aug 15 20:26:37 2014 |
ericq | Update | General | Game plan |
Quote: |
Q already did the tweak up of the PSL SHG crystal alignment. HE SHOULD ELOG ABOUT THIS. What was the final power of green that you got? Do we have any record of a previous measurement to compare to?
|
As Jenne mentioned, I did this.
Specifically, I first tweaked the mirror pointing the IR into the SGH in pitch and yaw to maximize the green power, and then adjusted the little set screws on the side of the SHG to maximize further. Power after the harmonic separator was of order 150uW. On the Y Green BBPD, I got ~48uW, instead of the 40uW Rana, Jenne, and myself saw the other night.
HOWEVER,
now that I look through old ELOGs, I find some posts by Kiwamu saying the power should be around 650uW, and that he was able to get 640uW out. So: I should do this again, systematically, more carefully, etc., etc. (Linked ELOG also states that optimum SHG temperature is alignment dependent...)
|
10403
|
Fri Aug 15 17:24:44 2014 |
Harry | Update | General | Fiber Temp. | Earlier today Q and I somewhat resurrected my old PER measurement setup so I could run the temperature characterization experiment.
Unfortunately, when I tried to use the fiber illuminator, no light came from the other end, causing me to fail my primary goal for the summer of "don't break anything." The fiber has been re-spooled and labeled appropriately. Also sorry.
In addition to this, Q and I scavenged parts from the telescopes on the PSL and Y End tables, which were either not functional, or needed to have their mode matching adjusted, since we're using the non-PM fibers for FOL, which have a different numerical aperture, and thus slightly different output modes.
Specifically, this is involved removing the rotational mounts, and appropriate beam dumping.
My "calorimeter" still remains intact, in case anyone wants to make this measurement in the future, as this is my last day in the lab.
It's also effective at keeping drinks cold, if you'd rather use it for that. |
10402
|
Fri Aug 15 14:35:57 2014 |
ericq | Update | LSC | TRY mystery offset gone | One question answered, but another raised. The offset came from LSC-TRY switching to the ETMY-QPD signal from ETMY-TRY (Hi gain pd).
BUT WHY

|
10401
|
Fri Aug 15 14:09:21 2014 |
Jenne | Update | LSC | TRY mystery offset gone | Again unknown, but about 6 hours ago (so ~8am) the offset disappeared.
Here's a 1-day trend:

|
10400
|
Fri Aug 15 13:29:31 2014 |
Jenne | Update | General | Game plan: 15 Aug | 
The game plan graffle file is now in the 40m dropbox, so anyone can edit it. Please just make sure to keep the date in the top right corner accurate. |
10399
|
Fri Aug 15 02:05:55 2014 |
Jenne | Update | LSC | ALS in-loop spectra | Not sure why, but Rana and I didn't see the super high Xarm noise with ALS that we reported last night (elog 10382).
The in-loop ALS noise seems fine. The out of loop measurement while the ALS is locked is a little tricky, since ALS hold the arms within the POX/POY linear ranges.
Here is the in-loop noise:

|
10398
|
Fri Aug 15 01:31:44 2014 |
Jenne | Update | ASC | POP QPD to ETMs model wiring complete | I have added a few things to the ASS model, and the ASC sub-block, so that we can send POP QPD information down to the ETMs for CARM angular control after we've reduced the CARM offset and gotten some carrier buildup. I did not remove our ability to actuate on PRM, so that we can still play with it in PRMIsb cases.
The input matrix has been expanded so that it can send signals to new CARM_YAW and CARM_PIT filter banks. The corresponding filter banks have been created. The output matrix was also expanded to take in the 2 new servo outputs, and so it can send signals to both ETMs, pitch and yaw. I did not include any triggering logic for this new CARM situation, since I assume we'll just turn it on and off with our scripts. (We haven't really been using the triggering capability of the PRM ASC either lately, although it's all still there). I added the inputs and outputs of the CARM servos to the list of acquired channels.
The ASC sub-block:

I also modified the top level of the ASS model. This was just a simple addition of summing nodes for the ETMs, similar to what was already in place for the PRM, so that we can send both the ASS dither alignment signals and the ASC servo control signals to the optics.
The ASS top level:

I also quickly modified the ASC screen to expose all of the new options:

The ASS model was compiled, and restarted. As usual, this temporarily removes the biases on the input pointing tip tilts, but the pointing seems to have come back without any trouble. |
10397
|
Thu Aug 14 23:19:49 2014 |
rana | Summary | LSC | ETM Violin fundamental filters moved to LSC | We used to do violin mode and test mass body mode notches in the SUS-LSC filter modules. Now we want them balanced in the LSC and triggered by the LSC, so they're in the filter modules which go from the the LSC output matrix to the SUS.

Today, we were getting ETM violin mode ringups while doing ALS hunt and so we moved the bandstops into the LSC. I also changed the bandstop from a wide one which missed the ETMX mode to a double bandstop which gets both the ETMX and the ETMY mode. See attached image of the Bode mag.

|
10396
|
Thu Aug 14 22:58:59 2014 |
rana, jenne | Summary | Green Locking | ALS DIFF tuning | We've been having trouble tuning the ALS DIFF matrix. Trying to see if the MC2 EXC can be cancelled in ALS DARM by adjusting the relative gains in ALSX and ALSY Phase Tracker outputs.
There's a bunch of intermittent behavior. Between different ALS locks, we get more or less cancellation. We were checking this by driving MC2 at ~100-400 Hz and checking the ALS response (with the ALS loops closed). We noticed that the X and Y readbacks were different by ~5-10 degrees and that we could not cancel this MC2 signal in DARM by more than a factor of 4-5 or so. In the middle of this, we had one lock loss and it came back up with 100x cancellation?
Attached is a PDF showing a swept sine measurement of the ALSX, ALSY, and DARM signals. You can see that there is some phase shift between the two repsonses leading to imperfect cancellation. Any ideas? Whitening filters? HOM resonance? Alignment? |
Attachment 1: sweep.pdf
|
|
10395
|
Thu Aug 14 22:31:12 2014 |
Jenne | Update | LSC | TRY gets mystery offset | I don't know why, but TRY has somehow gotten a 0.3 count offset in the last hour.
Rana and I are witnesses for each other that neither of us has gone into the IFO room in the last several hours (and we're the only ones here). For some reason though, the TRY PD now has a 0.3 count offset. We have been doing some ALS locks, but we have not run the offset script in the last several hours. Closing the green shutter doesn't change things, and we still see the offset when the MC loses lock, so it's not to do with the end or the PSL laser. We haven't been in there, so there hasn't been a change in the room lights.

|
10394
|
Thu Aug 14 22:16:02 2014 |
Jenne | Update | SUS | Violin Mode filters for ETMs | The instigator of this was that we were seeing ring-ups of ETMs during our ALS locks this evening. We measured the ETMY violin resonance to be 624.10 Hz, and Rana found an elog saying that the ETMX was around 631 Hz, so we made a 2 notch filter and added it to FM4 of the LSC-SUS filter banks for both ETMs.
For the ETMY resonance, we measured the frequency in the DARM spectrum, and when we looked at the FINE_PHASE_OUT channels, the resonance was only in the Yarm sensor. So, we conclude that it is coming from ETMY.
Also in the realm of filter modules, the FM3 boost for CARM, DARM, XARM and YARM was changed from zero crossing to ramp with a 1sec ramp time. |
10393
|
Thu Aug 14 20:52:36 2014 |
rana | Update | Wiki | Violin Mode table added to Wiki | Mech Resonance Wiki
I've updated the wiki by trawling the elog for violin entries. Please keep it up to date so that we can make violin notches.
|
10392
|
Thu Aug 14 19:33:00 2014 |
Jenne | Configuration | IOO | Moved MC2 spot | Last night, and again just now, I used the ./MC2_spot_[direction] scripts to center the MC2 spot on the trans QPD. The MCWFS handled overall alignment to correct for the fact that the ratios in the script aren't perfect. When I was finished, I ran the MC WFS relief script from the WFS screen. Last night, and again today, things had drifted until the yaw spot was more than 0.5 counts off. |
10391
|
Thu Aug 14 19:23:25 2014 |
rana | HowTo | IOO | How do I set the FSS offset to make the PZT voltage start at the right place? | When the IMC locks, we want the FAST OUT of the TTFSS box to be close to zero volts. We also want the control signal from the MC Servo board to be close to 0 V. How to set this up?
With the IMC locked, we just servo the FSS input offset to minimize the MC board output :
ezcaservo -r C1:IOO-MC_FAST_MON -g 0.1 -t 10 C1:PSL-FSS_INOFFSET
I would have used "CDSUTILS", but that seems to have some sort of ridiculous bug where we can't have prefixes on channel names, even on the command line.  |
10390
|
Thu Aug 14 18:31:45 2014 |
ericq | Update | LSC | LSC Modeling Update | Based on the game plan, I have created a slew of updated pretty plots about our signals and loops.
First: With measured arm losses, when do we start to see REFL DC dip? At what arm buildup powers?
I updated my MIST model with the arm losses I've measured (Y:130ppm, X:530ppm), and some measured transmissions from the wiki, vs. the design parameters, as I used to have. Here is the DC sweep plot which is now hanging up in the control room.

In this plot, I also calculated what MIST thinks the full arm power buildup will be as compared to our single arm locking, and I get something of order 200, rather than the 600 we've tossed around in discussions. Nothing else is very different in this plot from the old version; though the REFLDC dip is a little bit wider.
Now, here are some radiation-pressure inclusive sensing transfer functions, for the anti-spring case (which in Rob's day was easier to lock for unknown reasons):
 
 
Next: Include new AO path TFs into CM model Look at possibilities for engaging AO path
With these TFs, and the recently measured+fit new AO TF, here are the open loop gains of the slow, digital, SqrtInv-sensed MCL CARM and fast, analog, REFLDC-sensed AO CARM loops for the region of offsets we've achieved and a little lower. The slow digital loop includes the 1k LP that we have used in the past, in addition to the normal CARM filters. I still need to figure out the right sequence of ( offset reduction / crossover frequency motion / overall gain adjustment ) that gets the coupled cavity resonance solidly within the loop bandwidth.
|
10389
|
Thu Aug 14 18:10:46 2014 |
Harry | Update | General | Fiber Temperature Effects Setup | Purpose
We want to characterize the sort of response the fibers have to temperature gradients along them (potentially altering indices of refraction, etc.)
Experimental Setup
I have constructed a sort of two chambered "calorimeter" (by which I mean some coolers and other assorted pieces of recycling.)
The idea is that half of the length of PM fiber resides in one chamber, and the other in the other.
One chamber will remain at an uncontrolled, stable temperature (as measured by thermocouple probe) while the other's temperature is varied using a heat gun.
Using this setup, one can measure losses in power, and effects on polarization within the fiber.
Caveat
This is currently living on the electronics bench until tomorrow morning, and is a little fragile, just in case it needs to be moved. |
Attachment 1: tempAffectsSetup.zip
|
10388
|
Thu Aug 14 18:05:05 2014 |
Jenne | Update | General | Updated game plan |
Quote: |
- Oplevs for PR2, PR3 => Almost impossible.
|
Because of the limited table space inside? That's the main reason I can think of that this method is hard. Am I missing something? |
10387
|
Thu Aug 14 18:02:11 2014 |
Koji | Update | General | Updated game plan | Got the idea of ASC.
- Oplevs for PR2, PR3 => PR2 seems OK. PR3 almost impossible. well turned out not too crazy. We need outside electronics.
- RF QPD => not trivial and very technical but possible. All outside work.
- Better TT => might be a good solution. |
10386
|
Thu Aug 14 15:51:37 2014 |
Jenne | Update | General | Updated game plan |
Quote: |
- ALS
End PDH UGF improvement / post mixer LPF investigation (with in 2 weeks)
- MC/FSS
Riju measured the MC REFL PD transimpedance. See ELOG and related.
- ASC
Why do we want to see less PRM motion? I thought PRC motion was causing
LSC issue of the central part. We wanted to maximize the PRM effect, don't we?
(Or is this to supress ETM motion during full lock?)
|
End PDH - good point, thanks.
ASC - Yes, this is so that we can use the POP QPD to feed back to the common ETMs after the CARM offset is already quite small. We will not use POP DC QPD for PRC any more.
Also, for future PRC ASC, I keep coming back to this in my head, but maybe it is less painful to install oplevs for PR2, PR3 than it would be to make an RF QPD. Neither is going to be trivially easy. But if we had sensors of the tip tilt motions, we could feed all of that back to the PRM to stabilize the PRC. |
10385
|
Thu Aug 14 15:42:29 2014 |
Koji | Update | General | Updated game plan | - ALS
End PDH UGF improvement / post mixer LPF investigation (with in 2 weeks)
- MC/FSS
Riju measured the MC REFL PD transimpedance. See ELOG and related.
- ASC
Why do we want to see less PRM motion? I thought PRC motion was causing
LSC issue of the central part. We wanted to maximize the PRM effect, don't we?
(Or is this to supress ETM motion during full lock?) |
10384
|
Thu Aug 14 15:10:47 2014 |
Andres | Update | IMC | Calculation for the input mode cleaner |
Quote: |
Can you please give us some more details on how this design was decided upon? What were the design considerations?
It would be nice to have a shorter path length for WFS2. What is the desired spot size on the WFS? How sensitive are they going to be to IMC input alignment? Are we still going to be recentering the WFS all the time?
|
I did the calculation, and I reduced the beam Path. In my calculation, I restricted the waist size at the WFSs to be between 1mm-2mm also the other parameter is that the Gouy Phase different between the WFSs have to be 90 degrees. I also try to minimize the amount of mirrors used. I found the Gouy phase to be 89.0622 degrees between the WFSs and the following table shows the solution that I got from a la mode:
label z (m) type parameters
----- ----- ---- ----------
MC1 0 flat mirror none:
MC3 0.1753 flat mirror none:
MC2 13.4587 curved mirror ROC: 17.8700 (m)
Lens1 28.8172 lens focalLength: 1.7183(m)
BS2 29.9475 flat mirror none:
First Mirror 30.0237 flat mirror none:
Lens3 30.1253 lens focalLength: -0.100 (m)
Lens2 30.1635 lens focalLength: 0.1250(m)
WFS1 30.2269 flat mirror none:
Second Mirror 30.2650 flat mirror none:
Third Mirror 30.5698 flat mirror none:
Lens4 30.8113 lens focalLength: -0.075 (m)
WFS2 31.0778 flat mirror none:
In the first image attached below is the a la mode solution that show the waist size in the first WFS, and I used that solution to calculate the solution of the waist size for the second WFS, which is shown in figure 2. I photoshop a picture to illustrate how the new setup it supposed to look like. |
Attachment 1: SolutionForTheModeCleanerSetup00.png
|
|
Attachment 2: SolutionForTheModeCleanerSetup11.png
|
|
Attachment 3: PossibleSetupForModeCleaner.PNG
|
|
Attachment 4: alaModeSolution.zip
|
10383
|
Thu Aug 14 14:58:03 2014 |
Jenne | Update | General | Updated game plan | 
(Updated as of 4pm) |
10382
|
Thu Aug 14 02:51:46 2014 |
Jenne | Update | General | Game plan | [Jenne, Rana]
* Decided that earlier mode hop scan won't give us the information that we were hoping for. We need to think about where we can actually see the frequency change. Can we use the IR beatnote that we will soon have to do this? We'd only be able to scan one laser temp at a time, but that's okay. Leave, say, the PSL temperature alone, and scan one of the end laser temps. Using the PSL as the reference, we will be able to see if the frequency of the end laser goes crazy and jumpy as we pass through a certain temp. Then, repeat while holding the end laser constant and scan the PSL. Thoughts?
* Meditated on PSL oplev servo, but I need to make a Matlab script that can evaluate different loops according to a cost function based on elog 9690.
* Aligned IFO to IR, then greens to arms (got back to 0.9 for GTRY, but only about 0.5 for GTRX, with the PSL green shutter closed). Then aligned green beams on the PSL table, since the PSL green pointing had changed a bit from Q's crystal alignment tweak-up earlier today. Beatnotes are nice and big (see elog 10381 - The Yarm is the larger beatnote, and the Xarm is the smaller one.)
* Was not able to lock ALS comm/diff and hold long enough to get both arms to IR resonance. Also, saw that TRY's RIN was more than 50%(!!!). We took a look, and there seems to be much more low frequency noise than there was when the spectrum in the control room was taken for the multicolor metrology paper:

* Tried to balance the ALS comm/diff input matrix, with not a lot of success. First of all, it looks like the Xarm has overall about 10 times more noise! We were exciting MC2 in position (~88 Hz, about 130 counts I think), and then looking at DARM_IN1 for the peak. When DARM_IN1 was just one of the 2 ALS error signals (i.e. one matrix element set to zero), versus when both matrix elements were set to 1, we saw a factor of only about 3 in reduction of the peak height. We were hoping to have better cancellation of this pure CARM signal in the DARM channel. The Xarm green PDH loses lock every ~5 or 10 minutes, and when we relock it, this cancellation seems different, so we want to try again tomorrow when the ALS is locked on comm / diff, rather than just the free running ALS that we have now. Although, if the balance of the input matrix changes lock-to-lock, we may need to consider redoing the green PSL table layout so we get a pure DARM beatnote signal like they have at the sites.
* We want to change how the watch script for ALS works, although this is a low-priority task. Rather than looking at the control signal, we should maybe look at the sum of all the coil outputs, multiplied by a pendulum TF, and use that as a rough displacement sensor. We want to be careful of pushing too hard at low frequencies, but we want to allow higher frequency actuation without having the watch script shut things down.
* Also, I should put on the to-do list the revamp of the ALS find IR resonance script. |
10381
|
Wed Aug 13 23:58:49 2014 |
rana | HowTo | Computer Scripts / Programs | HP8591E spectrum analyzer remote scan |
Quote: |
The script for running continuous scans on HP 8591E spectrum analyzer is located at scripts/general/netgpibdata/HP8591E_contdScan.py
|
There was no such script in the directory when I looked today, but I found one called HP8591E. Of course, it didn't run because it hadn't been tested from the scripts directory and pointed to some /users/nichin/ stuff.
I modified a couple of lines and then committed it and the default .YML parameter file to the SVN. It runs and produces plots continuously from the scripts directory.
*** also, as you can see, we have mostly recovered the green beat amplitudes after yesterday's FLL attack on the ALS *** |
Attachment 1: HP8591E_View.pdf
|
|
10380
|
Wed Aug 13 23:08:17 2014 |
rana | Update | IOO | FSS box TFs | As EQ pointed out recently, we're injecting into the FSS error point just after an RF pi filter, but before the VGA. We wondered what the weird filter impedance was doing to our signal if we inject after it. I used LISO to model this FSS common section and attach the plots.
The first plot shows the TF between the Test 1 input and the AD602 VGA input. This is NOT the input that we are actually using.
The second plot shows the TF between the IN1 port (which we are actually using) and the VGA input.
Neither of them shows the 1 MHz bump that we see in the measurements, so I suspect that the board has been modified...the hunt continues. We've got to pop the top of the TTFSS and take photos and measure from IN1 to VGA input.
** FSScomm.fil is now in the LISO SVN. The following command line will run it with two different cases and cat the PDF files into one. If you use an auto-refresh PDF viewer like Okular or Mac Preview, its a nicer display than the usual GNUplot window:
./mfil FSScomm.fil; sleep 1; pdftk FSScomm_run*.pdf cat output FSScomm.pdf |
Attachment 1: FSScomm.pdf
|
|
10379
|
Wed Aug 13 22:01:57 2014 |
rana | Update | IMC | Calculation for the input mode cleaner | Nic, Andres, and I discussed some more about the MC WFS project today. We want to shorten the proposed WFS2 path. Andres is going to explore moving the 2" diameter lens in coming up with layouts. We also want the WFS to face west so that we can see the diode face with an IR viewer easily and dump the reflected beams in the razor dumps.
We wondered about fixing the power levels and optical gain:
- What is the MC modulations depth? What would happen if we increase it a little? Does anyone know how to set it? Will this help the MC frequency noise?
- What is the max power on the WFS? I guess it should be set so that the power dissipation of the detector is less than 1 W with the MC unlocked. So P_diss = (100 V)*(I_tot), means that we should have less than 10 mA or ~50 mW when the MC is unlocked.
- Another consideration is saturation. The RF signals are tiny, but maybe the DC will saturate if we use any more power. The quadrants are saturated when unlocked and ~200 mV locked. According to D990249, the DC gain in the head is 1000 V/A. The measured power levels going into the heads (w/ MC unlocked) are: P_WFS1 = 4.9 mW and P_WFS2 = 7.7 mW. We don't have control of the DC gain, but there is a 10x and 100x switch available inside the demod board (D980233). From these numbers, I figure that we're in the 100x position and so the effective DC gain between photocurrent and the DC readback voltages is 100 kOhm. Therefore, we are in no danger of optical or electronics saturation. And the unlocked photocurrent of ~40/100000=0.4 mA => 0.04 W heat generated in the diode, so we're OK to increase the power level by another factor of 2-4 if we want.
- We noticed that the ADC inputs are moving by ~50 counts out of 65000, so we're doing a really bad job of signal conditioning. This was previously noticed 6 years ago but we failed to follow up on it. Feh.
While checking this out, I converted the McWFS DC offsets script from csh to bash and committed it to the SVN. We need to remove the prefix 'feature' that Jamie has introduced to cdsutils so that we can use C1 again.
|
10378
|
Wed Aug 13 19:23:09 2014 |
Jenne | Update | LSC | PSL, Aux laser mode hop check | This afternoon Q helped me put in some temporary PDs for checking for any mode hopping behavior in our 3 main lasers.
Q helped me install PDA55s on each of the lasers (I did the ends, he did the PSL) so that we could do the mode hop temperature check. For the Yend, I took the leakage transmission through the first Y1 steering mirror after the laser. This beam was dumped, so I replaced the dump with a PDA55. For the Xend, the equivalent mirrors are too close to the edge of the table, so I put in a spare Y1, and reflect most of the light to a beam dump. The leakage transmission then goes to a PDA55. Note that for both of these cases, no alignment of main laser path mirrors was touched, so we should just be able to remove them when we're through. For the PSL, I believe that Q took the rejected light from one of the PBSes before the PMC.
The end temporary PDs are using the TRX / TRY cables, so we will be looking at the C1:LSC-TR[x,y] channels for the power of the end lasers. The PSL's temporary PD is connected to the PMC REFL cable. For the end PDs, since I had filter banks available, I shuttered the end lasers and removed the dark offset. I then changed the gains to 1, so the values are in raw counts. The usual transmission normalization gains are noted in one of the control room notebooks.
I did a slow ezcastep and ramped the temperature of all 3 lasers over about an hour. Since we usually use the PSL around FSS slow slider value of zero, I swept that from -10 to +10. Since we usually use the Xend laser at around 10,000 counts, I swept that from 0 to 20,000. For the Yend laser, it is usually around -10,000 counts, so I swept it from -20,000 to 0. ezcastep -s 0.2 C1:ALS-X_SLOW_SERVO2_OFFSET +1,20000 C1:ALS-Y_SLOW_SERVO2_OFFSET +1,20000 C1:PSL-FSS_SLOWDC +0.001,20000
I was looking for something kind of similar to what Koji saw when he did this kind of sweep for the old MOPA (elog #2008), but didn't see any power jumps that looked suspicious.
Here is the PSL:

The Xend:

And the Yend:

|
10377
|
Wed Aug 13 17:37:43 2014 |
Jenne | Update | General | Game plan | 
Here's the game plan for things that we need to do to get this IFO locked up.
Red is for things that should be done today, or tomorrow if they don't get finished today (eg. laser mode hopping temperature check). Orange is for things that will become red once the current red things are gone (eg. inferring the POP QPD gouy phase, and moving it to minimized PRM information). Green is for things that we'd like to do, but aren't high priority (eg. X green mode matching). Blue is for things that we should remember, but not plan on working on soon (eg. putting PZTs on the Yend table for green).
TODAY so far:
Q already did the tweak up of the PSL SHG crystal alignment. HE SHOULD ELOG ABOUT THIS. What was the final power of green that you got? Do we have any record of a previous measurement to compare to?
Q helped me install PDA55s on each of the lasers (I did the ends, he did the PSL) so that we could do the mode hop temperature check. For the Yend, I took the leakage transmission through the first Y1 steering mirror after the laser. This beam was dumped, so I replaced the dump with a PDA55. For the Xend, the equivalent mirrors are too close to the edge of the table, so I put in a spare Y1, and reflect most of the light to a beam dump. The leakage transmission then goes to a PDA55. Note that for both of these cases, no alignment of main laser path mirrors was touched, so we should just be able to remove them when we're through. For the PSL, I believe that Q took the rejected light from one of the PBSes before the PMC. He mentioned that he bumped something, so had to realign the beam into the PMC, but that he was able to get the transmission back up to 0.802, when we were seeing it in the mid 0.7's for the last several days.
The end temporary PDs are using the TRX / TRY cables, so we will be looking at the C1:LSC-TR[x,y] channels for the power of the end lasers. The PSL's temporary PD is connected to the PMC REFL cable. For the end PDs, since I had filter banks available, I shuttered the end lasers and removed the dark offset. I then changed the gains to 1, so the values are in raw counts. The usual transmission normalization gains are noted in one of the control room notebooks.
I did a slow ezcastep and ramped the temperature of all 3 lasers over about an hour. I'll write a separate elog about how that went. |
10376
|
Wed Aug 13 16:12:55 2014 |
Harry | Update | General | FOL Layout Diagram | Per Q's request, I've made up a diagram of the complete FOL layout for general reference.

|
10375
|
Wed Aug 13 13:08:24 2014 |
rana | Update | IMC | Calculation for the input mode cleaner | Can you please give us some more details on how this design was decided upon? What were the design considerations?
It would be nice to have a shorter path length for WFS2. What is the desired spot size on the WFS? How sensitive are they going to be to IMC input alignment? Are we still going to be recentering the WFS all the time? |
10374
|
Wed Aug 13 10:50:04 2014 |
Andres | Update | IMC | Calculation for the input mode cleaner | Calculation for the input mode cleaner
I have been working on the calculation for the input mode cleaner. I have come out with a new optical setup that will allow us increase the Gouy phase different between the WFS to 90 degrees. I use a la mode to calculate it. The a la mode solution :
label z (m) type parameters
----- ----- ---- ----------
MC1 0 flat mirror none:
MC3 0.1753 flat mirror none:
MC2 13.4587 curved mirror ROC: 17.8700
Lens1 29.6300 lens focalLength: 1.7183
BS2 29.9475 flat mirror none:
First Mirror 30.0237 flat mirror none:
WFS1 30.2269 flat mirror none:
Second Mirror 30.2650 flat mirror none:
Third Mirror 30.5698 flat mirror none:
Lens2 30.9885 lens focalLength: 1
Fourth Mirror 31.0778 flat mirror none:
Lens3 31.4604 lens focalLength: 0.1000
Fifth Mirror 31.5350 flat mirror none:
Sixth Mirror 31.9414 flat mirror none:
WFS2 31.9922 flat mirror none:
I attached a pictures how the new setup is supposed to look like. |
Attachment 1: ModeCleanerSetup0.PNG
|
|
Attachment 2: alaModeModeCleanersolution.png
|
|
10373
|
Wed Aug 13 10:49:39 2014 |
Harry | Update | General | Weekly Update | In the past week, I designed and assembled coupling telescopes for the PSL and Y Arm Lasers
The Y Arm was coupled to ~5mV, and the PSL remains uncoupled.
For the next week, I'm planning on working on things like my presentation and/or final report.
Though as of last night, my computer refuses to turn on, so there may be some further "troubleshooting" involved in that whole process. |
10372
|
Wed Aug 13 03:03:37 2014 |
ericq | Update | General | Green beatnote troubles | [Jenne, Rana, ericq]
No luck locking tonight, as spent a while trying to figure out the complete absence of the green beatnotes. Long story short, we ended up having to adjust the pointing on the PSL table.
Unrelated to this, we also turned on the noise eater on the PSL laser because why not.
We hooked the BBPDs directly up to a 300MHz scope to try to see the beat as it happened. We witnessed a very strange intermittent ~800MHz oscillation on the Y BBPD, and weirder still, on both the RF and DC outputs of the PD, and the frequency was independent of the laser temperatures. This is to be investigated in the future, but was not related to the beat note state.
Some progress was made when we took some components out, and looked at the far field of the PSL-Ygreen overlap, and saw some misalignment, and corrected it. Putting the end laser temperature in the usual area allowed the beat note to be found, with the eventual amplitude of ~-40dBm directly out of the BBPD. The Y green alignment was pretty bad throughout, so this can be improved to bring the beat amplitude up. We should also check and make sure we're well aligned to the SHG with the PSL light. We're leaving the X beat for tomorrow, now knowing that we should be able to get it with careful alignment. |
10371
|
Tue Aug 12 23:07:24 2014 |
Harry | Update | General | PSL Telescope | I put the PSL telescope in place, and started coupling to it.
Unfortunately, I was only able to couple about 55 uW into the "fiber coupler" (read: fiber coupled splitter). See picture below:

Additionally, I'm not sure why this is, but both of the splitters we ordered don't split equally, but to 90% and 10% in each output port.
We also found that, since we aren't using the fibers we originally intended to, the specs are a little different, and the waist we're trying to have at the collimator face is now 283 um. |
10370
|
Tue Aug 12 18:20:13 2014 |
ericq | Update | IOO | FSS box TFs | I made some measurements of the FSS box today, to have TFs for a loop model, but also to see what the difference between the different inputs was.
As a reminder, the FSS box takes the error signal from the MC servo, does some filtering, and sends out two outputs: one to the laser PZT via KojiBox and Thorlabs HV amplifier, and one to be summed with the PMC modulation signal to the PC. Rana found the schematic at D040105
The MC error signal currently enters via a port called "IN1", but there is also a "Test 1 in," which experiences different filtering. I measured the TFs from each of these inputs to both the FAST and PC outputs. There is also an IN2, that is added after the offset point, but was not able to make a good measurement, for reasons unknown. From these TFs, I inferred the difference between the PC and FAST path, as well as the difference between IN1 and Test 1 in.
Specifically, I plugged the cable that is usually connected to the MC servo output, labelled "TO FSS BOX", into the RF out of the AG4395. I then took a BNC cable from the FAST out, or PC out, and fed it into a mini circuits DC block (BLK-89-S+), and then into input A, after checking on a scope that the signal was roughly zeroed and not too huge. Unbeknownst to me at the time, the PC drive output can be pretty big, and could potentially fry the analyzer's input. Fortunately, I think I avoided this fate.
 
A ~1.3 MHz bump can be seen here, which would conspire with the bump in the demod board I measured yesterday, to steal even more phase around 1MHz. Maybe we can modify the FSS box to help our gain peaking situation out.
The data is attached.
RXA: Shazam! |
Attachment 3: FSSdata.zip
|
10369
|
Tue Aug 12 14:29:01 2014 |
ericq | Update | General | Reasonable alignment restored |
I'm leaving the interferometer with the PRM aligned, so that all optics (except SRM) are near the center of their oplev range. I'm curious as to what their variance will be over the next day; this can inform whether we need to improve the ETMY oplev's angular range or not.
|
Here's an 12 hour minute-trend of all of the oplevs. The worst offenders are ITMY pitch and yaw, and ITMX pitch.
Additionally, ETMY's yaw range is +-30urad, and here we see it wandering by 10 urad in a half day. We probably need more range.

|
10368
|
Tue Aug 12 13:31:58 2014 |
Jenne | Update | PEM | Seismometer cables in place, ready for sensors | [TaraV, Jenne]
The short cable from the slab to the sensor has been assembled and installed for the Trillium slab at the corner station. The corner still needs the sensor and the long cable, both of which are in use by the gyro experiment.
The STS-2 cable that was running to the Xend was pulled, and the new long Guralp cable that Den made was installed with help from Andres. The Xend just needs the sensor itself, which is also in use in gyro-land.
So, once we get the 2 seismometers and the one cable back from Zach, we should have 3 sensors nicely on the slabs that Den and Steve designed. |
10367
|
Tue Aug 12 02:09:39 2014 |
ericq | Update | General | Reasonable alignment restored | I took over the IFO, after Jenne's locking efforts, which included manual alignment, since the ASS was doing bad things.
For whatever reason, the Yarm ASS TT gains needed to be flipped back to go in the right direction. I've restored the old BURT snap file, and the ASS seems to work for now.
Furthermore, I added some FMs to the Yarm ASS to be able to ramp down gains, to be done as new offsets are ramped in, so that a smooth offset transition is possible. The new version of the script works reasonably, but could be smoother still... Once I iron this out, I'll do the same change to the Xarm, and update the buttons.
In any case, I was able to run ASS on both arms; single arm lock maxed out at around 0.85, maybe because we're only getting 0.78 from the PMC and 16k from the MC? I then aligned and locked the PRM, then reentered the oplevs on all of the PRMI optics. Oddly, the ETMs were at single uRads on their oplevs.
With this arm alignment, I was able to get the green TRX to ~0.55, and thus the beatnote to around -25dBm, which is still lower than we'd like. I didn't touch the Y green alignment, though it is pretty bad, at transmission of below 0.2 when "locked" on the 00 mode.
When I try to lock things, the initial ALS CARM and DARM locking seems to go fine, actuating on the ETMs for both DoFs, but ETMX is getting kicked during the resonance search every time. Maybe improving green alignment / increasing beatnote amplitudes will hopefully help some.
I'm leaving the interferometer with the PRM aligned, so that all optics (except SRM) are near the center of their oplev range. I'm curious as to what their variance will be over the next day; this can inform whether we need to improve the ETMY oplev's angular range or not. |
10366
|
Mon Aug 11 23:50:38 2014 |
rana | Configuration | Wiki | DokuWikis are back up |
Quote: |
Quote: |
It looks like auth is broken on the AIC wiki (though working fine on ATF and Cryo). I did some poking around but can't see how anything we did could have broken it.
|
I went into local.php and changed $conf['useacl'] = 1; to $conf['useacl'] = 0; and it looks like the auth issue goes away (I've changed it back). This isn't a fix (we want to use access control), but it gives us a clue as to where the problem is.
|
There was still some residual permissions issue. This is now bypassed and so the ACL is ON and all seems to be back the way it was. I've tested that I can login and edit the wiki.
Some useless knowledge follows here. Please ignore.
After some hours of reading unhelpful DokuWiki blogs, I just put the backup wiki into the local disk on NODUS and then made a soft link to point to that from /users/public_html/wiki/. So this implies that the new NFS setup on chiara is different enough that it doesn't allow read/write access to the apache user on the NODUS/Solaris machine. |
10365
|
Mon Aug 11 23:32:54 2014 |
ericq | Summary | IOO | MC demod measurement | Here's the magnitude plot of the board TF. As mentioned above, this was done with Marconi+Scope, so we were not able to get the phase of this transfer function.

Oddly enough, the bump that I saw is not included in Minicircuit's data on the SCLF-5. |
Attachment 2: demodLP.txt
|
# F(Hz) RMS(mV)
1035 38.6
2031 38.47
4031 38.47
8032 38.38
16030 38.10
32030 38.10
64030 38.16
128000 38.10
256000 38.22
... 12 more lines ...
|
10364
|
Mon Aug 11 22:07:31 2014 |
Koji | Summary | IOO | MC demod measurement | SCLF-5!? It's surprising as the cut off of the OLTF is just above 1Hz. cf this entry
This means that not the demod board but MC or FSS boards seem to have large attenuation above 1MHz.
In this situation, does SCLF-10/10.7 really help us? |
10363
|
Mon Aug 11 21:03:48 2014 |
ericq, rana | Summary | IOO | MC demod measurement | We measured the TF of the MC Demod board today.
We set the Marconi to +3dBm and drove the PD IN port of the demod board, starting at 29.5 MHz. Then we looked at the beat signal amplitude in the output of the demod board. So this is a transfer function but with mag only. Plots from Q below.
Rana took the demod board out and took pictures of it. Inside, the post mixer low pass is a SCLF-5 from mini-circuits. This has a lot of cutoff down low. Since the purpose of this filter is only to cutoff the 2f-1f and the 3f-2f products, we need to have a lot of attenuation at 29.5 MHz. One day, we may want to re-instate that notch for the (3*f1- f_MC) beat frequency, but for now we want stability.
So, I recommend that we (Steve) get 3 each of the SCLF-10 and SCLF-10.7 from Mini-Circuits Tuesday morning. Maybe we can put them into a spare board?
Also, we should probably remove the 140kHz:70kHz lead filter which is in the MC servo board. Its out of date. I think it would be fine for us to get a 7-15 kHz UGF for the CM servo and the MC can basically do that already. Mainly we want to fix the high frequency shape to get more stability.
After the measurements and photos, we had to reset the MCWFS offsets to get the WFS to not break the lock. Seems very sensitive to offsets. Hopefully Andres will give us a new Gouy phase telescope. |
10362
|
Mon Aug 11 10:23:39 2014 |
steve | Summary | SUS | oplev laser summary updated |
Quote: |
2005 ALL oplev servos use Coherent DIODE LASERS # 31-0425-000, 670 nm, 1 mW
Sep. 28, 2006 optical lever noise budget with DC readout in 40m, LIGO- T060234-00-R, Reinecke & Rana
May 22, 2007 BS, SRM & PRM He Ne 1103P takes over from diode
May 29, 2007 low RIN He Ne JDSU 1103P selected, 5 purchased sn: T8078254, T8078256, T8078257, T8078258 & T8077178 in Sep. 2007
Nov 30, 2007 Uniphase 1103P divergence measured
Nov. 30, 2007 ETMX old Uniphase 1103P from 2002 dies: .............., running time not known......~3-5 years?
May 19, 2008 ETMY old Uniphase 1103P from 1999 dies;.....................running time not known.....~ ?
Oct. 2, 2008 ITMX & ITMY are still diodes, meaning others are converted to 1103P earlier
JDSU 1103P were replaced as follows:
May 11, 2011 ETMX replaced, life time 1,258 days or 3.4 years
May 13, 2014 ETMX , LT 1,098 days or 3 y
May 22, 2012 ETMY, LT 1,464 days or 4 y
Oct. 5, 2011 BS & PRM, LT 4 years, laser in place at 1,037 days or 2.8 y
Sep. 13, 2011 ITMY old 1103P & SRM diode laser replaced by 1125P ..........old He life time is not known, 1125P in place 1,059 days or 2.9 y
June 26, 2013 ITMX 622 days or 1.7 y note: we changed because of beam quality.........................laser in place 420 days or 1.2 y
Sep. 27, 2013 purchased 3 JDSU 1103P lasers, sn: P893516, P893518, P893519 ......2 spares ( also 2 spares of 1125P of 5 mW & larger body )
|
May 13, 2014 ETMX, .............laser in place 90 d
May 22, 2012 ETMY,
Oct. 7, 2013 ETMY, LT 503 d or 1.4 y............bad beam quality ?
Aug. 8, 2014 ETMY, .............laser in place 425 days or 1.2 y
|
10361
|
Mon Aug 11 08:04:01 2014 |
Steve | Update | SUS | ETMX damping restored | |
10360
|
Sun Aug 10 00:54:54 2014 |
Harry | Update | General | AUX Couping | The Y End laser dumped SHG light has been coupled into the yellow fiber that terminates at the PSL table.
It's not super stably coupled, and only at 5mW. I'll be interested to see what it is on monday. |
10359
|
Sat Aug 9 14:35:28 2014 |
Koji | Summary | IOO | MC servo analysis | Eric's OLTF turned out consistent with the AO path TF that has been measured by me on Jul 31 (entry 10322).
Attachment 1:
Updated empirical fit of the open loop TF by LISO.
In this fit, I gave some of the poles/zeros associated with the boost manually set so that I can use them for the servo design.
LISO itself can make better fitting if all of the variables are moved.
Atatchment 2:
The OLTF data and LISO source for the fitting.
Attachment 3:
Comparison of the AO path TFs. The red one was measured directly on Jul 31. The TF is normalized at the low frequency.
The blue was estimated from the OLTF model given above. They are well consistent now.
Attachment 4:
Now some servo design was tried. In the new design (blue), zeros of the super boost frequency was moved from 20kHz to 30kHz
with the hope of having flatter AO response. The improvement is very little while costing costing above 100kHz. Note that the vertical
axis is intentionally in a linear scale. In fact, the AO response is much improved compared to the one before the MC UGF was increased
(shown in magenta). We have a flatter response both in magnitude and phase.
Therefore I think there is no need to tweak the boost frequency for the AO path.
I'd rather recommend to inspect the high frequency LPFs to earn more gain margin at 1MHz as explained in entry 10322.
Attachment 5:
This figure shows the comparison of the TFs for the current and new design trial, just in case someone is interested in to see.
|
Attachment 1: MC_OLTF_Fit.pdf
|
|
Attachment 2: liso.zip
|
Attachment 3: MC_CLTF_Fit.pdf
|
|
Attachment 4: MC_CLTF_new.pdf
|
|
Attachment 5: MC_OLTF_new.pdf
|
|
10358
|
Fri Aug 8 20:22:12 2014 |
Jenne | Metaphysics | General | kitchen sink water off |
Quote: |
When I got back to the lab, there was enough water that it was seeping under the wall, and visible outside. Physical plant says it will take an hour before they can come, so I'm getting dinner, then will let them in.
|
The guy from physical plant came, and turned off the water to the kitchen sink. He is putting in a work order to have the plumbers come look at it on Monday morning. It looks like something is wrong with the water heater, and we're getting water out of the safety overpressure valve / pipe.
The wet things from under the sink are stacked (a little haphazardly) next to the cupboards. |
10357
|
Fri Aug 8 19:42:59 2014 |
Jenne | Metaphysics | General | kitchen sink flooding | When I got back to the lab, there was enough water that it was seeping under the wall, and visible outside. Physical plant says it will take an hour before they can come, so I'm getting dinner, then will let them in. |
10356
|
Fri Aug 8 18:08:12 2014 |
Koji | Summary | IOO | MC servo analysis | The closed gain I meant is the AO path: Use IN2 to excite the MC loop and measure IN1 using MON2(?).
In order to obtain the open loop gain from this meausrement, the gain mismatching needs to be compensated, though.
This measurement is to correctly predict the AO path response from the open loop transfer function.
Anyway, the openloop gain seems nicely measured. I'll try to predict AO path response from this. |
10355
|
Fri Aug 8 16:45:40 2014 |
Nichin | Update | Wiki | PDFR wiki updated | The PDFR system has been documented in the 40m wiki and all the relevant information about making changes and keeping it updated have been mentioned.
https://wiki-40m.ligo.caltech.edu/Electronics/PDFR_system
This pretty much wraps up my SURF 2014 project at the 40m lab. |
|