Harry | Update | General | Fiber Mode Measurement |
Quote: |
Purpose
The idea was to measure the profile of the light coming out of the fiber, so we could have knowledge of it for further design of measurement apparatuses, for characterization of the fibers' properties.
Methods
The method was the same as the last time I tried to measure the fiber mode.
This time I moved the beam profiler in a wider range along the z-axis.
Additionally, I adjusted the coupling until it gave ~1mW through the fiber, so the signal was high enough to be reliably detectable.
Measurements were taken in both X and Y transections of the beam.
The range of movement was limited by the aperture of the beam profiler, which cuts off at 9mm. My measurements stop at 8.3mm, as the next possible measurement was beyond the beam profiler's range.

Analysis
I entered my data into A La Mode, which gave me a waist of 5um, at a location of z = -0.0071 m, that is to say, 7.1mm inside the fiber.
Note that in the plot, data points and fits overlap, and so are sometimes hard to distinguish from each other.
Code is attached.

Moving Forward
Using this data, I will begin designing setups to measure fiber characteristics, the first of which being Polarization Extinction Ratio.
Eventually, the data collected from these measurements will be put to use in the frequency offset locking setup.
|
Edit
The previous data were flawed, in that they were taken in groups of three, as I had to move the micrometer stage which held the beamscan between holes in the optical table.
In order to correct for this, I clamped a straightedge (ruler) to the table, so I could more consistently align the profiler with the beam axis.
These data gave a waist w_o = 4um, located 6mm inside the fiber. While these figures are very close to what I would expect (3.3um at the end of the fiber) the fitting still isn't as good as I would like.
The fit given by ALM is below.

Moving Forward
I would like to get a stage//rail so I can align the axes of the beam and profiler more consistently.
I would also like to use an aperture the more precisely align the profiler aperture with the beam axis.
Once these measurements have been made, I can begin assembling the setup to measure the Polarization Extinction Ratio of the fiber. |
10248
|
Mon Jul 21 17:32:43 2014 |
ericq | Summary | LSC | Arm losses |
Quote: |
From the last plot:
- Subtracting the offset of 0.0095, the modulation depth were estimated to be 0.20 for 11MHz, 0.25 for 55MHz
- Carrier TEM00 1.0, 1st order 0.01, 2nd order 0.05, 3rd order 0.002, 4th order 0.004
==> mode matching ~93%, dominat higher order is the 2nd order (5%).
Eric: now we have the number for the mode matching. How much did the cavity round-trip loss be using this number?
|
Using these numbers for both arms (Modulation takes away .2*.25 = 5% power, mode matching takes away 7% after that), I get the following from my data from March:
Xarm loss is 561.19 +/- 14.57 ppm
Yarm loss is 130.67 +/- 18.97 ppm
Obviously, the Xarm number looks very fishy, but its behavior was qualitatively very different when I took the data. ASDC would change from ~0.298 to ~0.306 when the Yarm was locked vs. misaligned, whereas the xarm numbers were .240 to .275.
In any case, I'll do the measurement again tomorrow, being careful with offsets and alignment; it won't take too long. |
10247
|
Mon Jul 21 13:58:33 2014 |
ericq | Update | IOO | MC autolocker acting up |
The autolocker claimed it was running and blinking, but not doing anything (i.e. lock bit was not updating and no switches or sliders being touched)
After stopping and starting it a number of times, it began working again, through no real changes of my own. I'm a little mystified as to what the problem was... keep an eye out. |
10246
|
Mon Jul 21 12:16:27 2014 |
Akhil | Summary | Electronics | Filters used inside the Frequency Counter |
The expected bode plots for such a filter with L= 4 is attached and compared with the measured.
RXA: When comparing two things, please put them onto the same plot so that they can be compared. |
Attachment 1: FC_TF_Characterization.png
|
|
10245
|
Mon Jul 21 10:51:06 2014 |
Steve | Update | VAC | N2 supply run out |
Interlock closed valve V1, V4, V5 and VM1 when the nitrogen supply run out. The IFO pressure rose to P1 1 mTorr
In order to recover Vacuum Normal valve configuration I did the following:
Replaced both nitrogen cylinders. Confirmed pneumatic nitrogen pressure 70 PSI. Opened valves V4 and V5
At P2 < 1 mTorr, Maglev rotation 560 Hz , V1 was opened.
VM1 was opened when CC1 pressure dropped below < 1e-5 torr
Please take a look at the N2 cylinders pressure on Friday to insure that there is enough for the week end.
The daily consumption is 600-700 PSI |
Attachment 1: outofN2.png
|
|
10244
|
Mon Jul 21 10:30:38 2014 |
Harry | Update | General | Fiber Mode Measurement |
Purpose
The idea was to measure the profile of the light coming out of the fiber, so we could have knowledge of it for further design of measurement apparatuses, for characterization of the fibers' properties.
Methods
The method was the same as the last time I tried to measure the fiber mode.
This time I moved the beam profiler in a wider range along the z-axis.
Additionally, I adjusted the coupling until it gave ~1mW through the fiber, so the signal was high enough to be reliably detectable.
Measurements were taken in both X and Y transections of the beam.
The range of movement was limited by the aperture of the beam profiler, which cuts off at 9mm. My measurements stop at 8.3mm, as the next possible measurement was beyond the beam profiler's range.

Analysis
I entered my data into A La Mode, which gave me a waist of 5um, at a location of z = -0.0071 m, that is to say, 7.1mm inside the fiber.
Note that in the plot, data points and fits overlap, and so are sometimes hard to distinguish from each other.
Code is attached.

Moving Forward
Using this data, I will begin designing setups to measure fiber characteristics, the first of which being Polarization Extinction Ratio.
Eventually, the data collected from these measurements will be put to use in the frequency offset locking setup. |
Attachment 3: fiberModeMeasurement2.zip
|
10243
|
Sun Jul 20 09:26:27 2014 |
Evan | Update | Electronics | MC servo card modifications in DCC |
Quote: |
[Rana, Jenne]
We have decided to keep better track (using new-fangled digital "computers") of our modifications to electronics boards.
The idea will be to create a new DCC document for every electronics board (when we pull a board and modify it, it should receive this treatment) that we have, and that document will become a history of the board's life. Version 1 will be a copy of the original drawing. Version 2 should be a modified version of that drawing with the current situation. All future versions should be modified from the most recent version, to reflect any changes. Notes for each updated version should include an elog reference to the work, so that we know why we did things, and have a place to find photos of the actual modifications. Elogs should also include a link to the DCC version. DCC titles should include the phrase "40m Revisions" for ease of searching.
Patient Zero for this new system will be the PMC servo card. The DCC number is D1400221. As of this moment, this just has the V1 original drawing with no modifications.
This has been included in the 40m's DCC document tree that Jamie started back in November 2012.
|
Patient One for this new system will be the MC servo card. The DCC number is D1400242. Currently, v1 is just the original drawing with no modifications. I've updated the DCC document tree at E1400326 accordingly.
It looks like we can use Jenne's information in 40m:9892 to deduce the modifications that have been made (alternatively, someone can just pull the board and examine it on the bench). |
10242
|
Sat Jul 19 20:51:51 2014 |
Koji | Update | LSC | RIN in arm transmission |
Your calibration of the ALS signal should be revised.
The phase for the ALS is not an optical phase of the green but the phase of the phase tracker servo output.
The calibration of the phase tracker depends on the cable length of the delay line in the beat box.
It seems that we are based on this calibration. Which gives up ~19kHz/deg.
Or, equivalently, use C1:.....PHASE_OUT_HZ instead. |
10241
|
Sat Jul 19 17:36:44 2014 |
Jenne | Update | LSC | RIN in arm transmission |
I looked at what the RIN contribution of the sqrtInv sensor is by locking the arms individually on IR using POX and POY. I then took spectra of the sqrtInv channels. For the Xarm, I had forced the triggering so that the QPD was being used as the transmission PD, while the Yarm was using the regular Thorlabs PD. I also had the green lasers locked to the arms, and took beatnote spectra to see what the sensing noise of the beatnotes is, all at the same time.
For the sqrtInv channels, I used the Optickle calibration from elog 10187. For today's plot, I am using the calibration at about 1nm, since that is about where we are when we transition to the sqrtInv Thorlabs signal usually.
For the ALS channel, I was using the _FINE_PHASE_OUT signal, which is in units of degrees of phase for a single green wavelength. So, since k * x = phi, I want the phase data to be converted to radians (2*pi/360), and use k = 2*pi / lambda_green. So, doing some algebra, this gives me x = phi_degrees * lambda / 360 for my calibration.
What I see in the plot is that the ALS sensing noise is pretty bad compared to the sqrtInv channels, so maybe we don't have to work so hard on the ISS this next week. Also, the Thorlabs PD is much better than the QPDs, which maybe isn't so surprising since we have them set so that they have good SNR at higher power.
Anyhow, here's the plot:

Also, here is the Thorlabs PD only, with single arm locked on RF, with the noise calibrated to different CARM offsets:

|
10240
|
Sat Jul 19 01:59:34 2014 |
Harry | Update | General | Fiber Mode Measurement |
Purpose
We wanted to measure the mode coming out of the fibers, so we can later couple it to experimental setups for measuring different noise sources within the fiber. i.e. Polarization Extinction Ratio, Frequency Noise, Temperature Effects.
Methods
I used the beamscan mounted on a micrometer stage in order to measure the spot sizes of the fiber coupled light at different points along the optical axis, in much the same way as in the razorblade setup I used earlier in the summer.

Analysis
I entered my data (z coordinates, spot size in x, spot size in y) into a la mode to obtain the beam profile (waist size, location)
Code is attached in .zip file.
Moving Forward
After I took these measurements, Manasa pointed out that I need points over a longer distance. (These were taken over the range of the micrometer stage, which is 0.5 inches.)
I will be coming in to the 40m early on Monday to make these measurements, since precious beamscan time is so elusive.
Eventually, we will use this measurement to design optical setups to characterize Polarization Extinction Ratio, Frequency Noise, and temperature effects of the fibers, for further use in FOL. |
Attachment 3: fiberModeMeasurement1.zip
|
10239
|
Fri Jul 18 19:32:50 2014 |
Akhil | Summary | Electronics | Filters used inside the Frequency Counter |
Thanks Koji , for your hint for the brain teasing puzzle. I was looking into Filters that are usually used in devices like counters, DSO and other scopes. I found that , to improve the quality of the measurement one of the best approach is averaging. I looked deeper into averaging and found out this:
There are two general use-cases for averaging . The first, successive sample averaging, takes a single acquisition and averages between its samples. The second, successive capture averaging, combines the corresponding samples of multiple captures to create a single capture. Successive sample averaging is also called boxcar filtering or moving average filtering. In an implementation of this type of averaging each output sample represents the average value of M consecutive input samples. This type of averaging removes noise (one of the reasons the noise level was not bad: http://nodus.ligo.caltech.edu:8080/40m/10151) by decreasing the device's bandwidth(could be one of the reasons why the FC operates in 4 different frequency ranges). It applies an LPF function with a 3dB point approximated by 0.433 * s / M, where M is the number of samples to be averaged, and s is the sample rate in samples per second.
Now I tried verifying the 3 dB points in the gain plots I generated :
For 1 s Sampling time : the 3 dB point for such a Boxcar filter should be at 0.433* 1/M. If we assume that it averages for 2 samples, M=2 which gives the 3dB point at 0.288 Hz but occurs somewhere between 0.3 and 0.4 Hz. (http://nodus.ligo.caltech.edu:8080/40m/140619_120548/GainVsFreq.png)
For 0.1s Sampling time: the 3dB point should be at 2.17 Hz and in reality is 2.5 Hz(http://nodus.ligo.caltech.edu:8080/40m/140701_211904/gain.png).
Also, This type of filter will have very sharp nulls at frequencies corresponding to signals whose periods are integer sub-multiples of M/s. As seen my previous plots (http://nodus.ligo.caltech.edu:8080/40m/10118 , http://nodus.ligo.caltech.edu:8080/40m/10070) there are sharp nulls at frequencies
0.4 Hz for 1S sampling time and
at 1.5 Hz,3 Hz for 0.1 S sampling time as correctly predicted.
The moving average filter is L-sample moving average FIR, with the frequency response as: H(ω) = (1/L) (1 − e− jω L)/(1 − e− jω)..
There is an overall delay of (M - 1)/2 samples from such a length-M causal FIR filter.
The expected bode plots for such a filter with L= 5 is attached(attachment 2). |
Attachment 1: TheoreticalGainPlot.png
|
|
Attachment 2: TFexpected.png
|
|
10238
|
Fri Jul 18 17:10:57 2014 |
Nichin | Summary | Electronics | Characterization of demodulator boards. |
Rack 1Y2, I took transfer function measurements for each of the following demodulator boards: REFL11, REFL33, REFL55, REFL165, AS55, POP22, POX11 and POY11.
What I did:
1) Removed the wire at PD Input to demodulator board.
2) Put the MOD output from network analyzer into PD input of board.
3) Ran a sweep from 100kHz to 100MHz.
4) Measured the transfer function between PD RF MON and PD Input. (The PD RF MON signal came out of the RF multiplexer, so the mux is included as well )
5) Put the original wire back at PD Input.
Results:
The plots clearly show an attenuation of 20dB (factor of 10) for all the demodulator boards. This explains why my transimpedance measurements are off by 10 times.
Note: for REFL 165, there was an extra 100MHz high pass filter installed at PD Input. I did not remove this and made my measurements along with this.
To Do:
a) Modify the PDFR system to calibrate out this attenuation.
b) Measure the transfer function between the input and output of RF mux, so that we can have just the transfer function between PD input an PD RF MON (for documentation's sake)
|
Attachment 1: Demodulators_TF.pdf
|
|
10237
|
Fri Jul 18 16:52:56 2014 |
Andres | Update | 40m Xend Table upgrade | FInish Calculation on Current X-arm mode Matching |
Quote: |
Data and Calculation for the Xarm Current Mode Matching
Two days ago, Nick, Jenne, and I took a measurement for the Green Transmission for the X-arm. I took the data and I analyzed it. The first figure attached below is the raw data plotted. I used the function findpeaks in Matlab, and I found all the peaks. Then, by taking close look at the plot, I chose two peaks as shown in the second figure attached below. I took the ratio of the TEM00 and the High order mode, and I average them. This gave me a Mode Matching of 0.9215, which this value is pretty close to the value that I predicted by using a la Mode in http://nodus.ligo.caltech.edu:8080/40m/10191, which is 0.9343. Nick and I measured the reflected power when the cavity is unlocked and when the cavity is locked, so we measured the PreflUnLocked=52+1µW and PreflOnLocked=16+2µW and the backgroundNoise=0.761µW. Using this information we calculated Prefl/Pin=0.297. Now, since Prefl/Pin=|Eref/Ein|2, we looked at the electric fields component by using the reflectivity of the mirror we calculated 0.67. The number doesn't agree, but this is because we didn't take into account the losses when making this calculation. I'm working in the calculation that will include the losses.
Today, Nick and I ordered the lenses and the mirrors. I'm working in putting together a representation of how much improvement the new design will give us in comparison to the current setup.
|
We want to be able to graphically see how much better it is the new optical table setup in comparison to the current optical table setup. In other words, we want to be able to see how displacement of the beam and how much angle change can be obtained at the ETM from changing the mirrors angles independently. Depending on the spread of the mirrors' vectors we can observe whether the Gouy phase is good. In the plot below, the dotted lines correspond to the current set up, and we can see that the lines are not spread from each other, which essentially mean that changing the angles of the two mirrors just contribute to small change in angle and in the displacement of the beam at the ETM, and therefore the Gouy phase is not good. Now on the other hand. The other solid lines correspond to the new setup mirrors. We can observe that the spread of the line of mirror 1 and mirror 4 is almost 90 degrees, which just implies that there is a good Gouy phase different between these two mirrors. For the angles chosen in the plot, I looked at how much the PZT yaw the mirrors from the elog http://nodus.ligo.caltech.edu:8080/40m/8912. In this elog, they give a plot in mrad/v for the pitch and yaw, so I took the range that the PZT can yaw the mirrors, and I converted into mdegrees/v and then I plotted as shown below. I plot for the current setup and for the new setup in the same plot. The matlab code is also attached below. |
Attachment 1: OldAndNewSetupPlotsOfDisplacementAndAngleAtTheETM.png
|
|
Attachment 2: OldSetUpDisplacementAndNewSetup.m.zip
|
10236
|
Fri Jul 18 15:21:12 2014 |
ericq | Update | Computer Scripts / Programs | Local Chiara backups |
Quote: |
I've also written a backup script at scripts/backup/rsync_chiara.backup which keeps its books in scripts/backup/rsync_chiara.backup.log
I'm adding a entry to the root crontab on chiara to execute the script every day at 7am.
|
I had some syntax errors in the script that prevented the script from doing the right thing. The backup is now up to date, and the cronjob should work. |
10235
|
Fri Jul 18 14:59:07 2014 |
Evan | Update | IOO | MC servo TFs |
[Rana, Evan]
This morning we took several TFs of the MC servo board using the HP4395A.
The 4395 source was teed, with one output of the tee going to 4395 R and the other output going to the board's IN1. We then took TFs of (4395 A) / (4395 R), where 4395 A was one of the following four points on the servo board:
- OUT2
- A TEST1
- B TEST1
- SERVO
For each of these points, we took a TF at two gain settings: IN1 and VCO gains both at 0 dB, and then IN1 and VCO gains both at 20 dB.
Before doing these measurements, we calibrated out the cable delay. Additionally, SERVO was always loaded with 50 Ω—either from the 4395 or from a terminator.
The attached png shows the servo board settings when these TFs were taken with the 0 dB gain settings. The settings for the 20 dB measurements are identical, except for the higher IN1 and VCO gains. |
Attachment 1: mcServoTFSettings.png
|
|
Attachment 2: MCtfs.pdf
|
|
10234
|
Thu Jul 17 22:08:14 2014 |
Koji | Update | General | 1X2 Rack Changes |
It sounds like the work was done carefully. Even so, Jenne or Manasa have to run the ALS (X and Y) to check if they are still functional. |
10233
|
Thu Jul 17 21:01:28 2014 |
Manasa | Update | General | 1X2 Rack Changes |
Quote: |
Purpose
Steve and I moved some things around in the 1X2 rack in order to make room (roughly 6") for the electronics box that will contain rf frequency counters, ADC, and Raspberry Pi's for use in the Frequency Offset Locking apparatus
Picture

Occurrences
First, we killed power by removing the fuse that the boxes we were moving were running through.
Then, we moved the boxes. I dropped//lost a washer. It didn't seem to cause any problems, so no further attempts to locate it were made.
The fuse was reinstalled, and everything was reconnected.
Moving Forward
We are now working on putting together the electronics box, which will contain ADC, and raspberry pi's. The frequency counters will be mounted on the front of the box.
Once complete, it will be installed for use in FOL.
|
Additional comments:
This was done based on the earlier proposed setup plan for the frequency counters that will be used to measure the beat note frequencies [Akhil's elog]
I switched off the power supply to the green PDs so that we don't cause any damage while moving the amplifier panel for the beat signals and beatbox. |
10232
|
Thu Jul 17 17:39:57 2014 |
Koji | Update | Electronics | PDFR debugging attempt : REFL11 |
What is the coupling factor between the RF in and the RF mon of the demodulator?
I don't assume you have the same amount RF power at those two points unless you have an RF amplifier in the mon path. |
10231
|
Thu Jul 17 17:19:25 2014 |
Steve | Update | PSL | PSL Innolight controller fan is dying with extra fan |
Quote: |
[Koji, Manasa]
The air flow from the dying fan was kinda weak and we decided to give a help with an external fan.
Koji brought a fan taken from a junk found at EE shop in W.Bridge.
The fan has been tied to the cage of the existing fan using cable ties to provide air circulation.
So even if the existing one dies anytime, we still don't super-heat anything.
The power supply for the fan rests next to the controller.
The air from the fan ventilation was hot, and now with the additional fan this hot air is actually sucked
out with stronger flow. So this is relieving for now.
|
PMC transmission as an indicator of laser controller with extra fan solution: 8 and 1day plot |
Attachment 1: fanadded.png
|
|
10230
|
Thu Jul 17 17:08:58 2014 |
Harry | Update | General | 1X2 Rack Changes |
Purpose
Steve and I moved some things around in the 1X2 rack in order to make room (roughly 6") for the electronics box that will contain rf frequency counters, ADC, and Raspberry Pi's for use in the Frequency Offset Locking apparatus
Picture

Occurrences
First, we killed power by removing the fuse that the boxes we were moving were running through.
Then, we moved the boxes. I dropped//lost a washer. It didn't seem to cause any problems, so no further attempts to locate it were made.
The fuse was reinstalled, and everything was reconnected.
Moving Forward
We are now working on putting together the electronics box, which will contain ADC, and raspberry pi's. The frequency counters will be mounted on the front of the box.
Once complete, it will be installed for use in FOL. |
10229
|
Thu Jul 17 16:39:34 2014 |
Nichin | Update | Electronics | PDFR debugging attempt : REFL11 |
In a attempt to debug the values of transimpedance generated by the PDFR system, I did a manual measurement for REFL11 PD.
- Took the tops off AS and POY tables. (REFL11 and REF PD) Under the supervising eye of Manasa
- Verify that no extra light is falling on REFL11.
- Retake DC voltage readings, power readings.
- Manually set the sweep parameters and record readings from network analyzer.
- Put the tops back on the tables
- Calculate transimpedance
Results:
REF PD(1611):
Pinc = 1.12 mW T_dc = 10000 V/A (datasheet)
Vdc = 7.68 V T_rf = 700 V/A (datasheet)
Calculated Responsivity = 0.68 A/W (Which matches perfectly with the datasheet value of 0.68 A/W)
REFL11:
Pinc = 0.87 mV T_dc = 66.2 V/A (schematic)
Vdc = 32.5 mV
Calculated Responsivity = 0.56 A/W
Network analyzer reading at 11 MHz : 0.42
Calculated RF Transimpedance = 460 V/A
40m Wiki : RF Transimpedance = 4 kV/A
I ran the same measurement using PDFR system and got the same results.
Attached: the automatic data and plot obtained.
Conclusion: The PDFR system and manual measurements agree with each other. However the values do not match with 40m Wiki. I have no clue about which measurement is correct or any mistakes I might be making in the calculations.
|
Attachment 1: REFL11_17-07-2014_154534.pdf
|
|
Attachment 2: REFL11_17-07-2014_154534.zip
|
10227
|
Thu Jul 17 16:07:34 2014 |
Emily | Update | Electronics | VCO Driver |
I took back he VCO driver that Reetika brought over to the 40m from the PSL lab. |
10226
|
Thu Jul 17 02:57:32 2014 |
Andres | Update | 40m Xend Table upgrade | FInish Calculation on Current X-arm mode Matching |
Data and Calculation for the Xarm Current Mode Matching
Two days ago, Nick, Jenne, and I took a measurement for the Green Transmission for the X-arm. I took the data and I analyzed it. The first figure attached below is the raw data plotted. I used the function findpeaks in Matlab, and I found all the peaks. Then, by taking close look at the plot, I chose two peaks as shown in the second figure attached below. I took the ratio of the TEM00 and the High order mode, and I average them. This gave me a Mode Matching of 0.9215, which this value is pretty close to the value that I predicted by using a la Mode in http://nodus.ligo.caltech.edu:8080/40m/10191, which is 0.9343. Nick and I measured the reflected power when the cavity is unlocked and when the cavity is locked, so we measured the PreflUnLocked=52+1µW and PreflOnLocked=16+2µW and the backgroundNoise=0.761µW. Using this information we calculated Prefl/Pin=0.297. Now, since Prefl/Pin=|Eref/Ein|2, we looked at the electric fields component by using the reflectivity of the mirror we calculated 0.67. The number doesn't agree, but this is because we didn't take into account the losses when making this calculation. I'm working in the calculation that will include the losses.
Today, Nick and I ordered the lenses and the mirrors. I'm working in putting together a representation of how much improvement the new design will give us in comparison to the current setup.
|
Attachment 1: RawDataForTheModeGreenScan.png
|
|
Attachment 2: ResultForModeMatching.png
|
|
Attachment 3: DataAndCalculationOfModeMismatch.zip
|
10225
|
Thu Jul 17 01:24:35 2014 |
rana | Update | IOO | MC / EOM Stability Mystery Solved! |
MC loop is near unstable. Common gain reduced. Needs more loop tuning.
We've often seen that the MC gets into a state where it keeps losing lock and the EOM drive shows a large RMS. We've usually been looking at the noise spectrum to diagnose this.
Tonight we finally just measured the OLG. The attached plot shows the loop gain measured with the 4395 on the MC servo board
Although the phase margin is a healthy 45 degrees, its close to instability at 1 MHz. For this plot, I reduced the gain by 3 dB and now the margin is ~7 dB. So usually its pretty close to unstable and at least its always making a noise peak.
That whole TF above a few hundred kHz is weird. We should tune out whatever makes it so flat and also remove the resonance that makes the 1 MHz peak; maybe its from some post mixer low pass?
Anyone interested in helping in the investigation ought to measure the TF of the MC demod board, the MC servo board, and the FSS box.
Silver lining: if we fix this loop shape, we might be able to have a much more stable IMC and IFO. |
Attachment 1: MC_OLG.pdf
|
|
10224
|
Thu Jul 17 00:38:30 2014 |
Jenne | Update | LSC | RIN in arm transmission |
[Rana, Jenne]
We had a look at the RIN of the transmission signals TRX and TRY, when the arms were individually locked on IR. If the intensity noise is very bad, then the transmission signals aren't really a good option to use for locking. So, if the RIN is bad, we need to work on our intensity stabilization.
We need to understand what the situation is with the AOM, and why it isn't working as expected, so that we can reinstall it. We also need to decide if we're going to use the SR560 setup, or if the Chas ISS is sufficiently characterized for us to use.
The RIN is certainly bad. Also, I don't know why the Xarm's RIN is worse between 10 Hz and a few hundred Hz than the Yarm.

|
10223
|
Wed Jul 16 23:02:16 2014 |
Koji | Summary | Electronics | Bode Plots and complete Characterization of Frequency Counter |
If I assume 1sample delay for 0.1s sampling rate, the delay is Exp[-I 2 pi f T], where T is the sampling period.
This means that you expect only 36 deg phase delay at 1Hz. In reality, it's 90deg. Huge!
Also there are suspicious zeros at ~1.6Hz and ~3Hz. This may suggest that the freq counter is doing some
internal averaging like a moving average.
It would be interesting to apply a theoretical curve on the plot. It's an intellectual puzzle. |
10222
|
Wed Jul 16 22:17:40 2014 |
Akhil | Summary | Electronics | Bode Plots and complete Characterization of Frequency Counter |
Goal:
To estimate the transfer function and the noise in the FC that is a part of the FOL-PID loop.
Measurements Taken:
The setup used for the measurements is described in my previous elogs.
The input modulation signal and the FC output were recorded simultaneously for a certain period of time and the phase and gain are estimated from the data.
Analysis(Data and code attached):
The recordings must contain equal number of data points(around 6000 data points in my measurements) for analysis.
The steps I followed to generate these plots are:
- Took the FFT of both FC out data(from FC) and Modulation input(from SRS via ADC).
- Estimated the phase angles at the particular modulation frequencies from the FFT data(in Matlab using angle(x) for phase at the frequency f(x);x: is the frequency bin)
- Then for the phase of the system at a particular modulation frequency,
Phase(system) =Phase(FC Signal) - Phase(Input Signal)
- Plotted the acquired phase vs the modulation frequency on a Semi-log graph.
Results:
From the plots its can be inferred that :the delay of the FC is almost 0 until the modulation of 0.1 Hz. Then there are phase shifts of +/- 180 degrees showing that the system has multiple poles and zeroes(will be estimated after I have phase plots at few more carrier frequencies).
To Do Next:
Phase plots for varying carrier frequencies and different sampling times.
Installation of FC inside the 40m. |
Attachment 1: Phase_Data.zip
|
Attachment 2: Bode100MHz.png
|
|
10221
|
Wed Jul 16 21:24:41 2014 |
Reetika | Update | Electronics | VCO Driver inside 40m |
I found the VCO driver, that Rana asked me to locate, inside the 40m. I already have one VCO from PSL lab. Now, I have kept both of them inside the 40m lab(one on the cart in the side of the Y-arm and the other near the X-arm electronics table). |
10220
|
Wed Jul 16 21:23:35 2014 |
Manasa | Update | PSL | PSL Innolight controller fan is dying |
[Koji, Manasa]
The air flow from the dying fan was kinda weak and we decided to give a help with an external fan.
Koji brought a fan taken from a junk found at EE shop in W.Bridge.
The fan has been tied to the cage of the existing fan using cable ties to provide air circulation.
So even if the existing one dies anytime, we still don't super-heat anything.
The power supply for the fan rests next to the controller.
The air from the fan ventilation was hot, and now with the additional fan this hot air is actually sucked
out with stronger flow. So this is relieving for now. |
Attachment 1: IMG_1659.JPG
|
|
Attachment 2: IMG_1658.JPG
|
|
10219
|
Wed Jul 16 19:38:37 2014 |
manasa | Summary | PSL | AOM alignment issues and removed from beam path |
AOM removed from the beampath and PMC relocked.
AOM alignment:
1. Measured the initial power after PMC as 1.30W and reduced it down to 130mW.
2. Checked the power in the AOM zero order transmission before touching it. For 0-1V modulation input, the power dropped from 125uW to 98.3uW.
3. Steered the mirror right before the AOM to increase AOM zero order transmission and then carefully moved the AOM around to obtain maximum power attenuation. I repeated this a few times and the maximum attenuation that I could obtain was 125uW to 89.2uW (~30% attenuation).
Although this is not the right way to align the AOM, we do not have much options with the current setup as there is not enough separation between the zero order and first order beams and the AOM is on a fixed rigid mount.
4. I tried to dump the first order beam from the AOM and it wasn't satisfactory as well. There is barely any separation between the zero order and first order beams.
PMC relocking:
1. SInce the alignment to the PMC was disturbed by moving the AOM and the steering mirror in front of it, the PMC alignment was lost.
2. I could not relock the PMC at low power or high power. Rana had to come to rescue and fixed the alignment so that we could see flashes of PMC on the trans camera (This was done by aligning refl beam to the PMC REFL PD while giving a triangular ramp to the PMC PZT voltage).
Also I should not have tried to lock the PMC at high power as I could have been steering the beam at high power to the edges of the PMC mirrors that way and burning stuff easily.
3. Before fine tuning the alignment, I decided to remove the AOM from the beam path as there needs some work done on it to make it useful.
4. I removed the AOM from the beam path and relocked the PMC.
5. PMC is relocked with 0.79 counts in TRANS and I measured the power after PMC 1.30W
Attachment: picture showing AOM removed from the beampath. |
Attachment 1: AOMremoved.jpg
|
|
10218
|
Wed Jul 16 17:34:11 2014 |
Harry | Update | General | Fiber Coupled |
Purpose
To couple the spare NPRO into our Panda PM980 fibers, in order to carry out tests to characterize the fibers, in order to use them in FOL.
Design
Manasa and I spent this morning building the setup to couple NPRO light into the fibers. We used two steering mirrors to precisely guide the beam into the coupler (collimator).
We also attached the lens to a moveable stage (in the z axis), so the setup could be fine tuned to put the beam waist precisely at the photodiode.
The fiber was attached to a fiber-coupled powermeter, so I would be able to tell the coupling efficiency.

Methods
During alignment, the NPRO was operating at 1.0 amps, roughly half of nominal current (2.1A).
I first placed the coupler at the distance that I believed the target waist of 231um to be.
Using the steering mirrors and the stage that holds the couple, I aligned the axes of the coupler and the beam.
Finally, I used the variable stage that the lens is attached to to fine tune the location of the target waist.
Results
Once I was getting readings on the powermeter (~0.5nW), the laser was turned up to nominal current of 2.1A.
At this point, I and getting 120nW through the fiber.
While far from "good" coupling, it is enough to start measuring some fiber characteristics.
Moving Forward
Tomorrow, I hope to borrow the beam profiler once again so as to measure the fiber mode.
Beyond this, I will be taking further measurements of the Polarization Extinction Ratio, the Frequency Noise within the fiber, and the effects of a temperature gradient upon the fiber.
Once these measurements are completed, the fiber will have been characterized, and will be ready for implementation in FOL. |
10217
|
Wed Jul 16 17:06:41 2014 |
Nichin | Update | Computer Scripts / Programs | HP8591E spectrum analyzer remote scan |
Updated script does the following:
1) Gets the highest 2 peaks
2) Puts a marker on the peaks. Now it looks very similar to the spectrum analyzer display.
3) The refresh rate is still 3 seconds. It might become better if the analyzer was hooked up to a wired martian LAN port rather than the wireless module I am using now.
PFA a sample pdf |
Attachment 1: HP8591E_View.pdf
|
|
10216
|
Wed Jul 16 15:26:48 2014 |
Steve | Update | PSL | PSL Innolight controller fan is dying |
Quote: |
Quote: |
Also, while I was working on the PSL table, I heard noise that sounded like a bearing rolling around. I suspected the HEPAs, since the one on the north east corner of the table has a problem when it's turned up high (we've known about this for a long time), however turning off the HEPAs didn't affect the noise. The noise is strongest near the back of the PSL controller on the shelf above the table, and the PSL controller box is vibrating. So, I suspect that the fan on the PSL controller box is about to give out.
EDIT: To clarify, I mean the Innolight's controller.
|
The bearing is chirping in the back of the 2W Innolight laser controller. It is loud enough to hear it. I placed 4 soft rubber feet under the controller to avoid shaking other things on self.
The HEPA filter bearing becomes noisy at 50V
Keep it at 20V for low noise
|
The fan is dying. It is changing speed erratically and stops for short time periods. It is very likely to stop rotating soon. It will halt all operations in the lab. We can not see the PMC-T power because Manasa is working on
AOM alignment.
|
10215
|
Wed Jul 16 07:51:52 2014 |
Akhil | Update | General | Weekly Update |
Work Done:
- Solved all the timing issues pertaining to the R Pi and the FC.
- Took all the measurements for complete characterization of the frequency counter(Phase Plots to follow shortly).
- Finished installation of the FC on the martian and created a channel for the FC frequencies(will be tested in this week).
Plans for this Week:
- Testing of the EPICS soft IOC created for the FC as a channel access server and hence completing the installation of the FC.
- Placing the FC inside the lab( plan discussed in this elog: http://nodus.ligo.caltech.edu:8080/40m/10163) with proper supervision.
- Characterization of the temperature actuator.
Inside the 40m Lab:
I will need to be inside the lab to place the FC . This will be done in the morning session (on thursday) with supervision of Manasa and Steve(if required).
|
10214
|
Wed Jul 16 02:22:10 2014 |
Koji | Update | Electronics | Test run of PDFR system |
Log-log ... |
10213
|
Wed Jul 16 01:54:25 2014 |
Nichin | Update | General | Work plan for next week |
1) Debugging transimpedance calculations in the PDFR
Requires presence of an expert whenever I get inside the lab to take DC measurements or check the illuminating fibers.
2) Creating and incorporating canonical data plots with every measurement of PDFR.
3) Transfer function fitting for transimpedance
4) Improve the Spectrum analyzer scan scripts as mentioned in my elog. |
10212
|
Wed Jul 16 01:46:41 2014 |
Nichin | Update | Electronics | Test run of PDFR system |
A test run was conducted on the PDFR system last afternoon and transimpedance plots were generated for 6 of the PDs. The laser was shut down after the test run.
I have not verified (yet) if the transimpedance values indicated by the plots are correct or not. The values mostly look INCORRECT. But the peaks are exactly where they need to be. *phew!*
Reasons: Incorrect calibration, Light other than from the PDFR system fibers on the PDs
Will have to work on debugging all this. |
Attachment 1: PDFR_testRun_15-07-2014.pdf
|
|
10211
|
Wed Jul 16 01:35:16 2014 |
Koji | Summary | LSC | Python Wavelet peak finding for dramatic ALS - Red Resonance finding speedup |
From the last plot:
- Subtracting the offset of 0.0095, the modulation depth were estimated to be 0.20 for 11MHz, 0.25 for 55MHz
- Carrier TEM00 1.0, 1st order 0.01, 2nd order 0.05, 3rd order 0.002, 4th order 0.004
==> mode matching ~93%, dominat higher order is the 2nd order (5%).
Eric: now we have the number for the mode matching. How much did the cavity round-trip loss be using this number? |
10210
|
Wed Jul 16 01:27:01 2014 |
Nichin | HowTo | Computer Scripts / Programs | HP8591E spectrum analyzer remote scan |
The script for running continuous scans on HP 8591E spectrum analyzer is located at scripts/general/netgpibdata/HP8591E_contdScan.py
Give the file HP8591E_param.yml as an argument when running the script. This contains the sweep parameters: Start and stop frequencies along with the place where the plot is stored as a PDF.
The default PDF is located on the Desktop and is named HP8591E_View.pdf Open this using okular and then run the script. (Okular pdf viewer automatically reloads the PDF as and when a new one is created)
What the script does:
1) Set the start and stop frequencies as given in the .yml file
2) Take a data trace and plot it in a PDF.
3) Repeat taking traces and update the PDF. Untill Ctrl+C is pressed (PDF refresh rate: approximately every 3 seconds )
4) Exit smoothly after the keyboard interrupt.
Other details:
This spectrum analyzer is connected to a GPIB - Ethernet controller that is configured as santuzza.martian (192.168.113.109)
I have currently stolen the wireless modem from the spectrum analyzer inside the lab (vanna.martian) and using it for this one. *poker face*
To improve:
Get the plot to show where the two biggest peaks are located. Currently it recognizes only the biggest one.
Possibly have makers on the two peaks.
PFA a sample pdf |
Attachment 1: HP8591E_View.pdf
|
|
10209
|
Wed Jul 16 01:18:02 2014 |
rana | Summary | LSC | Python Wavelet peak finding for dramatic ALS - Red Resonance finding speedup |
New script called scripts/ALS/findRedResonance.py finds the IR resonance in less than 20 seconds.
- Do a ~2 FSR scan of the arm over 10 seconds using the Phase Tracker servo offset ramp. (dt = 10 s)
- Load the frame data for the TR_OUT and the Phase Tracker phase. (dt = 2 s)
- Use Python (modern) SciPy to find all peaks with moderate SNR (dt = 3 s)
- Take the top 3 peaks (all presumably TEM00) and choose the one closest to zero and go there.
The above is the gist of what goes on, but there were several issues to overcome to get the code to run.
- None of our workstations have a modern enough Python distro to run either the ipython notebooks or the new SciPy with wavelets, so I installed Anaconda Python in the controls home directory.
- In order to get the peak finder function to work well I gave it a range of peak widths to look for. If we change the speed of the ALS scan by more than 3x, we probably have to change the width array in the function.
- I've used the find_peaks_cwt function in SciPy. This uses a Ricker ('Mexican Hat') wavelet to find peaks by doing multi-res transforms and looking for ridges in the wavelet space (I think)
- To make the code run fast, I downsample from 16 kHz to 1 kHz right at the top. Would be better if we had downsampling in v2 of the getData function.
|
Attachment 1: findRedResonance.pdf
|
|
10208
|
Wed Jul 16 01:04:09 2014 |
Jenne | Update | LSC | Data for DARM on sqrtInv investigation |
I realized while I was looking at last night's data that I had been doing CARM sweeps, when really I wanted to be doing DARM sweeps. I took a few sets of data of DARM sweeps while locked on ALSdiff. However, Rana pointed out that comparing ALSdiff to TRX-TRY isn't exactly a fair comparison while I'm locked on ALSdiff, since it's an in-loop signal, so it looks artificially quiet.
Anyhow, I may consider transitioning DARM over to AS55 temporarily so that I can look at both as out-of-loop sensors.
Also, so that I can try locking DARM on DC transmission, I have added 2 more columns to the LSC input matrix (now we're at 32!), for TRX and TRY. We already had sqrt inverse versions of these signals, but the plain TRX and TRY were only available as normalization signals before. Since Koji put in the facility to sqrt or not the normalization signals, I can now try:
Option 1: ( TRX - TRY ) / (TRX + TRY)
Option 2: ( TRX - TRY ) / sqrt( TRX + TRY )
DARM does not yet have the facility to normalize one signal (DC transmission) and not another (ALS diff), so I may need to include that soon. For tonight, I'm going to try just changing matrix elements with ezcastep.
Since I changed the c1lsc.mdl model, I compiled it, restarted the model, and checked the model in. I have also added these 2 columns to the AUX_ERR sub-screen for the LSC input matrix. I have not changed the LSC overview screen. |
10207
|
Tue Jul 15 22:23:51 2014 |
Andres | Update | 40m Xend Table upgrade | Scan the Xarm for the mode matching |
Nick and I with the help of Jenne scan the green light when the cavity is unlocked. Nick placed a Beam dump on the IR so that we can just scan the green, but it was removed as soon as we finished with the measurement. I'm working on the calculation, and i'll be posted solution tonight. |
10206
|
Tue Jul 15 21:43:28 2014 |
Jenne | Update | LSC | QPDs back |
I removed the dumps in front of the trans QPDs. The Yend QPD needed re-normalization, so I did that. |
10205
|
Tue Jul 15 18:39:04 2014 |
Harry | Update | General | Weekly Plan (7.16.14) |
The Past Week
Attempted to design coupling telescope, turned out waist measurement was still off. Took another waist measurement, this time more reasonable.
Used recent waist measurement to actually design a coupling system to couple NPRO light into Panda PM980 fibers (see recent elog)
The Next Week
Assemble fiber coupling system
Measure coupling efficiency, ensure it's at least 60%
Begin measuring Polarization Extinction ratio
Materials
PLCX lens with f = 0.25m ------> status: here
Fiber Coupled Powermeter//PD ------> status: unknown (have any laying around?)
Quarter Wave Plate, Polarizing Beamsplitter, Photodiodes ------> status: here
other components from original razorblade measurement setup |
10204
|
Tue Jul 15 18:26:40 2014 |
Harry | Update | General | Beam Waist, Telescope, and Fiber Coupling |
Goal
To design an optical setup (telescope / lens) to couple 1064nm NPRO light into PANDA PM980 fibers in order to characterize the fibers for further use in the frequency offset locking setup.
Design

Calculations
The beam waist of the NPRO was determined as 233um 6cm in front of the NPRO. This was used as the seed waist in ALM.
The numerical aperture of the fiber was given as 0.12, which allowed me to calculate the maximum angle of light it would accept, with respect to the optical axis, as NA = sin(theta) where theta is that angle.
Given that the coupler has a focal length of 2mm, I used the formula r = f * tan(theta), to yield a "target waist" for efficient coupling into the fiber. This ended up being 241.7um.
Since there was not a huge difference between the natural beam width of the NPRO and our target waist, I had no need for multiple lenses.
I used 230um as a target waist for a la mode, to leave myself some room for error while coupling. This process gave me a beam profile with a lens (f=0.25m), and a target waist of 231um, located 38.60cm from the coupling lens
I have attached ALM code, as well as the beam profile image. Note that the profile takes zero to be the location of the NPRO waist.

Next Steps
After this setup is assembled, and light is coupled into the fibers, we will use it to run various tests to the fiber, for further use in FOL. First of all, we wish to measure the coupling efficiency, which is the purpose of the powermeter in the above schematic. We will measure optical power before and after the fibers, hoping for at least ~%60 coupling. Next is the polarization extinction ratio measurement, for which we will control the input polarization to the fibers, and then measure what proportion of that polarization remains at the output of the fiber. |
Attachment 3: fiberTesting.zip
|
10203
|
Tue Jul 15 17:34:01 2014 |
manasa | Update | PSL | proposing AOM re-alignment |
I am going to tweak the alignment of the beam into the AOM (before the PMC) tomorrow morning. If anybody has any objections to this, please raise a red flag.
Proposed alignment procedure:
1. Reduce PSL power to say 10%
2. Since the AOM is not on any sort of a mechanical stage, I will have to just play around carefully until I see a maximum power rejection into first order.
I am assuming that moving the AOM is not going to affect the input pointing because all these activities are happening before the PMC. So as long as I have the output beam from the AOM aligned to the PMC at the end, everyone should be happy. |
10202
|
Tue Jul 15 12:36:17 2014 |
Nichin | Update | Electronics | RF cables rerouted |
Quote: |
I have not connected them to the RF switch yet. ( until I figure out how to get both the switches working properly)
|
I went into the lab and connected the RF cables to the Mux. Will take measurements for each PD henceforth. |
10201
|
Tue Jul 15 11:04:05 2014 |
Steve | Update | safety | safety glasses must be worn all times! |
This is the third safety glasses that I found laying around in the IFO lab lately. Safety glasses must be worn ALL times in the IFO room!
This rule is essential for your protection! Please do not enter if you can not put up with this regulation!
|
Attachment 1: safetyglasses.jpg
|
|
10200
|
Tue Jul 15 01:41:43 2014 |
Jenne | Update | LSC | Data for DARM on sqrtInv investigation |
I took some data tonight for a quick look at what combinations of DC signals might be good to use for DARM, as an alternative to ALS before we're ready for RF.
I had the arms locked with ALS, PRMI with REFL33, and tried to move the CARM offset between plus and minus 1. The PRMI wasn't holding lock closer than about -0.3 or +0.6, so that is also a problem. Also, I realized just now that I have left the beam dumps in front of the transmission QPDs, so I had prevented any switching of the trans PD source. This means that all of my data for C1:LSC-TR[x,y]_OUT_DQ is taken with the Thorlabs PDs, which is fine, although they saturate around arm powers of 4 ever since my analog gain increase on the whitening board. Anyhow, the IFO didn't hold lock for much beyond then anyway, so I didn't miss out on much. I need to remember to remove the dumps though!!
Self: Good stuff should be between 12:50am - 1:09am. One set of data was ./getdata -s 1089445700 -d 30 -c C1:LSC-TRX_OUT_DQ C1:LSC-TRY_OUT_DQ C1:LSC-CARM_IN1_DQ C1:LSC-PRCL_IN1_DQ |
10199
|
Tue Jul 15 01:31:13 2014 |
Akhil | Summary | Electronics | Timing Issues of Mini Circuits UFC-6000: Solved |
The attached are the PSD plots with improved FC timing(with the same code as in http://nodus.ligo.caltech.edu:8080/40m/10151). More plots(Phase and PSD) to follow.
|
Attachment 1: qnoise.png
|
|
Attachment 2: qnoise.pdf
|
|