40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 341 of 341  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  17155   Fri Sep 23 14:10:19 2022 RadhikaUpdateBHDBH55 RFPD installed - part I[Radhika, Paco, Anchal]

I placed a lens in the B-beam
path to focus the beam spot onto the RFPD
 IMG_3766.jpegIMG_3770.jpegIMG_3773.jpeg 
  17156   Fri Sep 23 18:31:46 2022 ranaUpdateBHDBH55 RFPD installed - part IA design flaw in these initial LIGO RFPDs
is that the SMA connector is not strain releieved
by mounting to the case. Since it is only
  
  17157   Fri Sep 23 19:04:12 2022 AnchalUpdateBHDBH55 LSC Model Updates - part IIIBH55

I further
updated LSC model today with following changes:


BH55 whitening switch binary
  
  17158   Fri Sep 23 19:07:03 2022 TegaUpdateComputersWork to improve stability of 40m models running on teststand [Chris, Tega]

Timing glitch investigation:


Moved dolphin
 dolphin_state_all_green.pngdolphin_state_IPC_glitch.png 
  17159   Mon Sep 26 11:39:37 2022 PacoUpdateBHDBH55 RFPD installed - part II[Paco, Anchal]

We followed rana's suggestion
for stress relief on the SMA joint in the
 PXL_20220926_175010061.MOTION.jpgBH55_Transimpedance_Measurement.pdf 
  17160   Tue Sep 27 10:50:11 2022 PacoUpdateBHDcalibrated LO phase noiseLocked LO phase to ITMX single bounce beam
at the AS port, using the DCPD (A-B) error
point and actuating on LO1 POS. For this
 lo_phase_asd.pdf 
  17161   Wed Sep 28 16:37:26 2022 PacoUpdateBHDcalibrated LO phase noise; update[yuta, paco]

Update; the high frequency ( >
100 Hz) drop is of course not real and comes
 lo_phase_asd.pdf 
  17162   Wed Sep 28 19:15:56 2022 KojiUpdateGeneralTesting 950nm laser found in trash pileI don't know what was wrong with the
past setup but the 950nm laser (QPHOTONICS
QFLD-950-3S) just worked fine up to ~300MHz
 PXL_20220929_013850989.MP.jpgPXL_20220929_013859439.jpgPXL_20220929_013911125.jpg 
  17163   Wed Sep 28 21:54:08 2022 PacoUpdateBHDcalibrated LO phase noise; updateRepeated the LO phase noise measurement,
this time with the LO - ITMY single
bounce, and a couple of fixes Koji
 dcpd_phase_asd.pdflo_phase_asd.pdf 
  17164   Thu Sep 29 15:12:02 2022 JCUpdateComputersSetup the 6 new front-ends to boot off the FB1 clone[Jamie, Christopher, JC]

This morning we decided to label
the the fiber optic cables. While doing this,
  
  17165   Thu Sep 29 18:01:14 2022 AnchalUpdateBHDBH55 LSC Model Updates - part IVMore model changes

c1lsc:


BH55_I and BH55_Q are now
being read at ADC_0_14 and ADC_0_15. The
  
ELOG V3.1.3-