40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 1 of 349  Not logged in ELOG logo
ID Date Author Typedown Category Subject Text Attachments
  60   Sun Nov 4 23:22:50 2007 waldmanUpdateOMCOMC PZT and driver response functionsI wrote a big long elog and then my browser
hung up,  so you get a less detailed entry.
 I used Pinkesh's calibration of the PZT
 7x 
  61   Sun Nov 4 23:55:24 2007 ranaUpdateIOOFriday's In-Vac workOn Friday morning when closing up we noticed
that we could not get the MC to flash any
modes.
  
  62   Mon Nov 5 07:29:35 2007 ranaUpdateIOOFriday's In-Vac workLiyuan recently did some of his pencil beam
scatterometer measurements measuring not
the
  
  63   Mon Nov 5 14:44:39 2007 waldmanUpdateOMCPZT response functions and De-whiteningThe PZT has two control paths:  a DC coupled
path with gain of 20,  range of 0 to 300
V,  and a pair of 1:10 whitening filters,
 07110_DithertoVmonAC_sweep2-0.png071105_LSCtoVmonDC_sweep4-0.png07110_DithertoVmonAC_sweep2.pdf071105_LSCtoVmonDC_sweep4.pdf 
  68   Tue Nov 6 14:51:03 2007 tobin, robUpdateIOOMode cleaner lengthUsing the Ward-Fricke variant* of the [url=http://ilog.ligo-wa.caltech.edu/ilog/pub/ilog.cgi?group=detector&date_to_view=02/14/2004&anchor_to_scroll_to=2004:02:15:00:06:50-daniel]Sigg-Frolov
method[/url], we found the length of the
mode cleaner to be [b]27.0934020183 meters[/b],
  
  69   Tue Nov 6 15:36:03 2007 robUpdateLSCXARM lockedEasily, after resetting the PSL Uniblitz shutters.
 There's no entry from David or Andrey about
the recovery from last week's power outage,
  
  76   Wed Nov 7 09:38:01 2007 steveUpdateVACrga scanpd65-m-d2 at cc1 6e-6 torr  pd65d2.jpg 
  81   Wed Nov 7 16:07:03 2007 steveUpdatePSLPSL & IOO trend1.5 days of happy psl-ioo with litle bumps
in C1:PSL-126MOPA_HTEMP
 psl1.5dtrend.jpg 
  82   Thu Nov 8 00:55:44 2007 pkpUpdateOMCSuspension tests[Sam , Pinkesh]

We tried to measure the transfer functions
 9x 
  83   Thu Nov 8 11:40:21 2007 steveUpdatePEMparticle counts are upI turned up the psl HEPA filter to 100%
This 4 days plot shows why
 pslhepaon.jpg 
  87   Fri Nov 9 00:23:12 2007 pkpUpdateOMCX and Z resonancesI got a couple of resonance plots going for
now. I am still having trouble getting the
Y measurement going for some reason. I will
 Xtransferfunc.pdfZtransferfunc.pdf 
  88   Fri Nov 9 09:37:55 2007 steveUpdatePSLhead temp hiccupJust an other PSL-126MOPA_HTEMP hiccup.
The water chiller is at 20.00C
 headtempup.jpg 
  93   Mon Nov 12 10:53:58 2007 pkpUpdateOMCVertical Transfer functions[Norna Sam Pinkesh]

These plots were created by injected white
 VerticalTrans.pdf 
  96   Mon Nov 12 15:18:34 2007 robUpdatePSLISS
After John soldered a 3.7 MHz notch filter
onto the ISS board, I took a quick TF and
 ISS.png 
  97   Mon Nov 12 23:44:19 2007 JohnUpdatePSLISS[quote]
After John soldered a 3.7 MHz notch filter
onto the ISS board, I took a quick TF and
 ISSfilter.jpg 
  98   Tue Nov 13 14:33:40 2007 JohnUpdatePSLISS filterThe transfer function from 'In Loop Error
Point Monitor' to TP3 the filter out test
point on the ISS board.
 PB130035.JPGDSC_0165.JPG 
  101   Wed Nov 14 12:47:19 2007 tobinUpdatePSLISSJohn, Tobin

With John's notch filter installed and the
  
  102   Wed Nov 14 16:54:54 2007 pkpUpdateOMCMuch better looking vertical transfer functions[Norna Pinkesh]

So after Chub did his wonderful mini-surgery
 VerticalTransPreampwireremovedNov142007.pdfVerticalTranswiresclampedNov142007.pdf 
  103   Wed Nov 14 17:50:00 2007 tobinUpdatePSLISSHere's the current wiring between the ISS
and its PDs:
  
  105   Thu Nov 15 17:09:37 2007 pkpUpdateOMCVertical Transfer functions with no cables attached.[Norna Pinkesh]

The cables connecting all the electronics
 VerticaltransferfuncnocablesattachedNov152007.pdf 
  106   Thu Nov 15 18:06:06 2007 tobinUpdateComputersalex: linux1 root file system hard disk's dyingI just noticed that Alex made [url=http://www.ldas-sw.ligo.caltech.edu/ilog/pub/ilog.cgi?group=40m&date_to_view=11/14/2007&anchor_to_scroll_to=2007:11:14:20:00:29-aivanov]an
entry in the old ilog[/url] yesterday, saying:
"[color=red][b]Looks like linux1 root filesystem
  
  109   Thu Nov 15 18:37:06 2007 tobinUpdateComputerspossible replacement for linux1's diskIt looks like the existing disk in linux1
is a Seagate ST380013A (this can be found
either via the smartctl utility or by looking
  
  110   Fri Nov 16 11:27:18 2007 tobinUpdateComputersscript fixI added a tidbit of code to "LIGOio.pm" that
fixes a [url=http://lhocds.ligo-wa.caltech.edu:8000/40m/EZCA]problem
with ezcastep on Linux[/url].  Scripts such
  
  111   Fri Nov 16 14:11:26 2007 tobinUpdateComputersop140Alan called to say that Phil Ehrens will be
coming by to take [b]op140[/b] off our hands.
  
  112   Fri Nov 16 14:31:43 2007 tobinUpdateComputersop140 disksPhil Ehrens stopped by and took op140's disks.  DSC_0173.JPG 
  117   Tue Nov 20 11:10:07 2007 tobinUpdateComputersepics access from matlabI installed "[url=http://www.slac.stanford.edu/~strauman/labca/]labca[/url]",
which allows [b]direct access to EPICS channels
from within Matlab[/b].  It comes with both
  
  121   Wed Nov 21 14:31:41 2007 robUpdatePSLFSS twiddle
I `tweaked' the FSS path today.  Here's what
I did:
  
  127   Tue Nov 27 20:47:00 2007 tobinUpdatePSLFSSRana, Tobin

We looked at the RF PD signal to the FSS
 fss-tf0001.pdf 
  128   Wed Nov 28 04:21:46 2007 ranaUpdatePSLFSS[quote]Rana, Tobin
[SIZE=1]
We looked at the RF PD signal to the FSS
  
  134   Wed Nov 28 17:41:34 2007 robUpdatePSLFSS againI investigated the FSS a bit more today. 
I looked at the signals coming out of the
FSS frequency reference, and saw that both
  
  136   Wed Nov 28 19:44:18 2007 tobinUpdatePSLHEPAI found the HEPA turned off completely.  I
turned it on.
  
  163   Tue Dec 4 23:16:35 2007 tobinUpdatePSLISSI was confused to find that I could increase
the ISS gain slider all the way from 15dB
to 30dB without seeing much of any increase
  
  165   Wed Dec 5 13:49:08 2007 albertoUpdateElectronicsRF AM PD lines monitorIn the last weeks Iíve been working on the
design of an electronic board to measure
directly the power of the main spectral lines
 alberto.spectrum2.pngButterworth.PNG 
  167   Wed Dec 5 17:49:57 2007 tobinUpdatePSLISSAttached is a plot of the ISS RIN with a variety
of gain settings.   
 rin.pdf 
  168   Wed Dec 5 18:08:36 2007 AndreyUpdateASCOptical Lever laser for ETMX is installed
A new laser with \lambda=633nm has been intalled
and the mirror adjusted so that the signal
 DSC_0199.JPG 
  169   Wed Dec 5 18:22:03 2007 tobinUpdatePSLISS dark noiseAttached is a plot of the dark noise spectrum
of the ISS photodiodes (1) before fooling
with them, (2) after replacing the 4151's
 sense_noise.pdf 
  171   Wed Dec 5 20:32:51 2007 tobinUpdatePSLISS dark noiseThe ISS dark noise is not coming from the
PD heads; the spectrum is essentially unchanged
when the PD is unplugged from the ISS.  Did
  
  177   Thu Dec 6 19:30:43 2007 tobinUpdatePSLISS dark noise - 60 Hz!A higher resolution spectrum [attached] shows
that nearly all of the excess dark noise
on the ISS is in 60 Hz harmonics (with some
 iss.pdf 
  181   Fri Dec 7 18:28:30 2007 tobinUpdateComputer Scripts / Programscompiled matlab hoses itselfAndrey pointed out to me that some matlab
functions in the Signal Processing Toolbox
were dying with errors.  Looking into the
  
  182   Fri Dec 7 18:31:30 2007 tobinUpdateComputer Scripts / Programscompiled matlab hoses itselfAddendnum.  The reason the linemon_mcr command
was in the path was because of the user issuing
the command "addpath(genpath(pwd))" where
  
  183   Fri Dec 7 19:14:30 2007 tobinUpdatePSLISS dark noise - ground loop enlightenmentMy alleged 60 Hz harmonics were all from a
ground loop created by connecting the SR785
ground to the ISS circuit ground; they disappeared
  
  185   Mon Dec 10 18:42:20 2007 tobinUpdatePSLISS RIN scriptI wrote a script to measure the ISS RIN. 
The script uses the "labca" interface (described
in an [url=http://dziban.ligo.caltech.edu:40/40m/117]earlier
 rin-20071210-1831.pdf 
  192   Sun Dec 16 16:52:40 2007 dmassUpdateComputersComputer on the end FixedI had Mike Pedraza look at the computer on
the end (tag c21256). It was running funny,
and turns out it was a bad HD.
  
  193   Mon Dec 17 11:47:13 2007 albertoUpdateElectronicsan alternative design for the RFAM monitor's filter at 33MhzSince the Butterworth turned out o be rather
wide-band, I tried an other configuration
for the 33 MHz filter. Attached are the simulated
 RFSim99-33MHz.pngRF99-SimmButterworthPrototype.pngRFSim99-33MHz-TFplot.png 
  195   Tue Dec 18 00:51:39 2007 AndreyUpdateComputer Scripts / ProgramsResults of Saturday overnight measurements
As I indicated in the previous e-log entry
(#194), I made overnight measurements in
 11x 
  196   Tue Dec 18 16:50:35 2007 tobinUpdateSAFETYuvex laser safety glasses defectiveA few days ago we noticed what appeared to
be a blotched, speckled fracturing of the
coating of the "UVEX" laser safety glasses.
 bad-glasses.jpgbad-glasses-zoom.jpg 
  197   Tue Dec 18 21:31:31 2007 tobinUpdatePSLISS RINMy measurements of the ISS RIN via the SR785
and via the DAQ disagree considerably. The
spectral shapes are very similar, however,
 iss-rin.pdf 
  201   Wed Dec 19 15:51:00 2007 AndreyUpdateComputer Scripts / ProgramsDaytime measurements in XARM and their results
I was making measurements in XARM for three
different nights. All the results agree with
 11x 
  203   Wed Dec 19 16:40:12 2007 steveUpdateSAFETYlaser safety glasses measuredI measured the coarse transission at 1064nm
 of the 40m safety glasses today.
  
  205   Thu Dec 20 02:04:09 2007 AndreyUpdateComputer Scripts / ProgramsNew overnight measurements in XARM and their results
I ran in the daytime/evening time my program,
changing the damping gains in suspension
 11x 
ELOG V3.1.3-