Sat May 24 22:56:57 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path
|
Mon May 26 07:59:23 2014, Koji, Update, Electronics, Amplifier removed from BeatX path
|
Tue May 27 11:58:45 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path
|
|
Message ID: 9992
Entry time: Mon May 26 07:59:23 2014
In reply to: 9991
Reply to this: 9995
|
Author: |
Koji |
Type: |
Update |
Category: |
Electronics |
Subject: |
Amplifier removed from BeatX path |
|
|
And the out-of-loop level of the ALSX compared with the previous measurement is ...?
Quote: |
I just realized that I forgot to elog this, but yesterday afternoon I bypassed the amplifier in the BeatX path, and now the X beatnote is about -27dBm. Arms lock nicely with ALS.
|
|