40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Sat May 24 22:56:57 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path
|
Mon May 26 07:59:23 2014, Koji, Update, Electronics, Amplifier removed from BeatX path
|
Tue May 27 11:58:45 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path
|
|
Message ID: 9991
Entry time: Sat May 24 22:56:57 2014
Reply to this: 9992
|
Author: |
Jenne |
Type: |
Update |
Category: |
Electronics |
Subject: |
Amplifier removed from BeatX path |
|
|
I just realized that I forgot to elog this, but yesterday afternoon I bypassed the amplifier in the BeatX path, and now the X beatnote is about -27dBm. Arms lock nicely with ALS. |