Entry  Tue Jan 7 22:44:45 2014, Jenne, Update, CDS, daqd on fb is segfaulting every ~30 seconds 
    Reply  Tue Jan 7 23:08:01 2014, jamie, Update, CDS, /frames is full, causing daqd to die 
       Reply  Tue Jan 7 23:13:47 2014, jamie, Update, CDS, /frames is full, causing daqd to die 
          Reply  Tue Jan 7 23:50:27 2014, jamie, Update, CDS, /frames space cleared up, daqd stabilized 
             Reply  Tue May 13 17:45:21 2014, rana, Update, CDS, /frames space cleared up, daqd stabilized 
                Reply  Thu May 15 01:42:07 2014, rana, Update, CDS, /frames space cleared up, daqd stabilized 
Message ID: 9955     Entry time: Thu May 15 01:42:07 2014     In reply to: 9949
Author: rana 
Type: Update 
Category: CDS 
Subject: /frames space cleared up, daqd stabilized 

 Script seems to be working now:

nodus:~>df -h | grep frames

fb:/frames              13T    12T   931G    93%    /frames