Entry  Wed May 7 16:31:12 2014, jamie, Update, CDS, cdsutils updated to version 226 
    Reply  Wed May 7 17:10:59 2014, rana, Update, CDS, cdsutils updated to version 226 
    Reply  Wed May 7 22:47:33 2014, rana, Update, CDS, cdsutils updated to version 226: not working on pianosa or rossa 
       Reply  Wed May 7 23:30:21 2014, jamie, Update, CDS, cdsutils should be working now 
          Reply  Thu May 8 01:33:21 2014, ericq, Update, CDS, python issues 
             Reply  Thu May 8 15:55:43 2014, jamie, Update, CDS, python issues 
    Reply  Wed Jun 18 13:39:01 2014, rana, Update, CDS, cdsutils reverted to version 238 
Message ID: 9928     Entry time: Thu May 8 01:33:21 2014     In reply to: 9926     Reply to this: 9931
Author: ericq 
Type: Update 
Category: CDS 
Subject: python issues 

On pianosa: The ezca.Ezca class somehow initializes with its prefix set to "C1:", even though the docstring says the default is None. This makes existing scripts act wonky, because they're looking for channels like "C1:C1:FO-BLAH".

In ligo/apps/linux-x86_64, I ran ln -sfn cdsutils-old cdsutils to get the old version back for now, so I don't have to edit all of our up/down scripts.

Also, Chiara can't find the epics package when I try to load Ezca. It exists in '/usr/lib/pymodules/python2.6/epics/__init__.pyc' on pianosa, but there is no corresponding 2.7 folder on chiara.

 