During a lull in Koji vs. The Arm, I switched on the MC2_TRANSQPD feedback path to check out its UGF. In the past months, when its been on, it has had a gain of ~0.03 - 0.1.
Today, I found that with the gain turned up to 11, it has a ~1 minute step response time (as you see in the above Strip chart). So its had a UGF of ~2 hours or so during the times when we thought it might be doing bad or good or magic.
I leave it on now to see if it behaves well over the next days. Let's see if Steve thinks its good or not based on his trend monitoring.
** also touched up the PMC pointing (using the PMC REFL image / please never align the beam into the PMC without this camera image) |