40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Fri Apr 18 20:17:17 2014, Jenne, Update, LSC, ALS noisy 
|
Mon Apr 21 22:53:16 2014, manasa, Update, LSC, ALS noise 
|
Tue Apr 22 01:11:42 2014, Jenne, Update, LSC, TRY 60Hz noise
|
Tue Apr 22 21:54:50 2014, manasa, Update, LSC, TRY 60Hz noise
|
Tue Apr 22 22:49:10 2014, rana, Update, LSC, TRY 60Hz noise
|
Wed Apr 23 19:58:00 2014, manasa, Update, LSC, TRY 60Hz noise
|
Tue May 6 18:32:14 2014, steve, Update, LSC, TRY 60Hz noise hunt
|
Wed May 7 14:01:36 2014, steve, Update, LSC, TRY 60Hz noise hunt
|
Thu May 8 17:25:17 2014, steve, Update, LSC, TRY 60Hz noise hunt
|
Fri May 16 16:08:12 2014, steve, Update, LSC, Isolating base plates
|
Wed Apr 23 23:48:30 2014, manasa, Update, LSC, Y end whitening board  
|
Thu Apr 24 14:23:09 2014, not manasa, Update, LSC, Y end whitening board
|
Thu Apr 24 23:55:31 2014, Koji, Update, LSC, Y end whitening board
|
Fri Apr 25 10:43:57 2014, Koji, Update, LSC, (Fixed) Y end whitening board   
|
Thu Dec 11 18:12:46 2014, ericq, Update, LSC, (Fixed) Y end whitening board
|
Thu Dec 11 22:44:23 2014, rana, Update, LSC, QPD screens
|
Thu Apr 24 00:11:35 2014, Jenne, Update, LSC, Yend shutter back.
|
Sun Apr 27 20:26:19 2014, Koji, Update, LSC, Phase Tracker servo characterization 
|
Sun Apr 27 21:30:59 2014, Koji, Update, LSC, ALS servo characterization 
|
Mon Apr 28 10:24:10 2014, Koji, Update, LSC, error signal characterization 
|
Mon Apr 28 10:34:51 2014, Koji, Update, LSC, new ALS servo design 
|
Mon Apr 28 10:48:48 2014, Koji, Update, LSC, new ALS servo design: comparison 
|
Mon Apr 28 10:59:54 2014, Koji, Update, LSC, New ALS servo design: expected error signals 
|
Mon Apr 28 11:08:11 2014, Koji, Update, LSC, New ALS servo design: expected error signals
|
|
Message ID: 9844
Entry time: Wed Apr 23 23:48:30 2014
In reply to: 9842
Reply to this: 9849
|
Author: |
manasa |
Type: |
Update |
Category: |
LSC |
Subject: |
Y end whitening board |
|
|
The MON outputs of the Y end QPD whitening board were hot earlier today while pulling it out of the crate. After swapping the 4 pin lemo connector with an isolated panel mount bnc connector, I stuck the board back into the crate and this immediately kicked the ETMY suspension. Jenne and I went to the Y end to look at what was going on. We removed the board from the crate after smelling something burning. The MON output ports of the whitening board were super hot this time. There is no sign of any components melting on the board (comparing the board with its pictures that were taken earlier) and a tester board stuck into the crate lights up just fine.
So the back panel is still ok. We need to troubleshoot or replace the whitening board.
Edit, JCD: The attached photos are from right after I replaced the "Rgain" resistor, elog 9823. What they show is that it looks like some of the melting / burning may have already been happening before I pulled the board, and I just never noticed :( In particular, look at the resistors on the main board above the blue "G" sticker. There isn't a difference that I can tell between this photo from last week, and today's situation.
 |
|
|
|
|