Fri Mar 28 20:23:02 2014, rana, Summary, IOO, MC2 moved
|
Mon Mar 31 11:34:00 2014, manasa, Summary, IOO, MC2 moved
|
Thu Apr 10 10:52:15 2014, manasa, Summary, IOO, MC2_TRANS path in WFS servo
|
Fri Apr 25 23:08:57 2014, rana, Summary, IOO, MC2_TRANS QPD Servo re-re-engaged again
|
Sat Apr 26 13:19:59 2014, ericq, Summary, IOO, MC2_TRANS QPD Servo re-re-engaged again
|
Mon Apr 28 15:47:57 2014, manasa, Summary, IOO, MC2_TRANS QPD Servo trend
|
Mon Apr 28 20:31:38 2014, rana, Summary, IOO, MC2_TRANS QPD Servo trend
|
Wed Apr 30 21:57:07 2014, rana, Summary, IOO, MC2_TRANS QPD Servo now on for real 
|
|
Message ID: 9794
Entry time: Thu Apr 10 10:52:15 2014
In reply to: 9764
|
Author: |
manasa |
Type: |
Summary |
Category: |
IOO |
Subject: |
MC2_TRANS path in WFS servo |
|
|
Quote: |
Quote: |
I've also turned on the MC2 TRANS path to gather some data over the weekend on how well or bad it works. Please turn it off on Monday.
|
MC2_TRANS path in WFS servo turned OFF.
|
[From yesterday]
The MC had not been stable lately with WFS drifting constantly. I checked the servo and found that the MC_TRANS path was still running. It turned out that the autolocker script enables the TRANS path in the locking process. I have turned the MC_TRANS path servo inputs OFF and now it is no more a part of the WFS servo.
P.S. Jenne fixed the PMC alignment mostly in pitch to bring it up to 0.81 from 0.77. But the temperature fluctuations have still not got us to the sweet spot for optimum PMC trans. |