40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Mar 17 09:27:05 2014, Steve, Update, SUS, 4.4M local earthquake 4.4M-Encino.png3.9-4.4Meq.pngEQdamage4.4.png
    Reply  Mon Mar 17 20:44:42 2014, rana, Update, SUS, 4.4M local earthquake 
       Reply  Mon Mar 17 21:55:36 2014, Koji, Update, SUS, 4.4M local earthquake 
          Reply  Tue Mar 18 00:51:02 2014, Jenne, Update, SUS, 4.4M local earthquake 
          Reply  Tue Mar 18 08:31:37 2014, Steve, Update, SUS, 4.4M local earthquake & its miracle miracel.pngETMX_LR.JPGETMX_LR-UL.JPGETMX_UL-LL-S-IRshield.jpg
             Reply  Tue Mar 18 18:05:57 2014, Steve, Update, SUS, ETMX osem UR ETMX_URcollapsing.jpgETMX_outoffocus.JPGURisFREE.png
Message ID: 9737     Entry time: Tue Mar 18 08:31:37 2014     In reply to: 9735     Reply to this: 9738
Author: Steve 
Type: Update 
Category: SUS 
Subject: 4.4M local earthquake & its miracle 

Quote:

It was little bit surprising to me but Rana's professorial rock'n roll excitation released its sticking on the unconfirmed thing by unconfirmed reason.

I aligned the Xarm manually and via ASS.

Now we are back in the normal state.

 This recovery proceeder deserves a pattern

Note: IR shield glass position variations,  Atm4

Attachment 1: miracel.png  336 kB  | Show | Show all
Attachment 2: ETMX_LR.JPG  650 kB  Uploaded Tue Mar 18 16:26:14 2014  | Show | Show all
Attachment 3: ETMX_LR-UL.JPG  1.158 MB  Uploaded Tue Mar 18 16:26:55 2014  | Show | Show all
Attachment 4: ETMX_UL-LL-S-IRshield.jpg  454 kB  Uploaded Wed Mar 19 10:48:21 2014  | Show | Show all
ELOG V3.1.3-