The previous LSC whitening filters for the DCPDs were in an unknown state (although the transfer functions were actually measured and fit a while ago)
They had no DC gain control and some of the channels had modifications.
To make the setup clear, the filter module was replaced with the spare module without any modification.
The channels are now respoding to the whitening gain switches. So far there is no screen for the new whitening gains yet.
Also I found that POX11 DC cable has not been connected. Now it is connected. |