I checked the offset situation in the CM servo boost circuit.
- The offset voltage on the CM servo screen is a raw DAC output. This number is diluted by the voltage divider before the amplifier.
So, the actual offset of the boost circuit was much smaller. (~20mV)
- There is a offset trimmer on the board. This was adjusted so that the boost does not generate an output offset.
- So the default offset is 0V.
- When the arm was locked with (digital) POY11, the CM servo offset is necessary to be -2.7 (now).
This means that analog POY11Q and digital POY11 has different offset for the best resonance transmission.
That is believable if POY11I is contributing to the digital POY11 signal. |