Entry  Fri Dec 20 00:16:39 2013, Koji, Summary, CDS, RCG parsing bug? Bit2Word1.pngBit2Word2.png
    Reply  Fri Dec 20 11:40:13 2013, Jamie, Summary, CDS, RCG parsing bug? 
    Reply  Fri Dec 20 18:00:02 2013, Koji, Summary, CDS, RCG parsing bug? Screenshot-c1lsc-LSC.png
Message ID: 9503     Entry time: Fri Dec 20 11:40:13 2013     In reply to: 9498
Author: Jamie 
Type: Summary 
Category: CDS 
Subject: RCG parsing bug? 

I submitted a bug report for this:

https://bugzilla.ligo-wa.caltech.edu/bugzilla3/show_bug.cgi?id=553

However, given how old our RCG version is (2.5 vs. 2.8 current deployed at the sites) I don't think we're going to see any traction on this.  Even if this is still a bug in 2.8, they'll only fix it in 2.8.  There's no way they're going to make a bug fix release for 2.5.

We need to upgrade.

ELOG V3.1.3-