up/down scripts are to be made
(Offset Edit on Dec 20 10:38PM)
Configuration:
POY11QMon -> CM Servo In1 -> CM Servo -->Out1 -> ADC -> CM Slow FM -> LSC MC Servo FM -> ETMY(x1.0) -> DAC -> ETMY
|
-->Servo Out -> SR560 (DC, 1st order 30kHz LPF) -> MC In2
Lock acquisition path 1
Initial condition:
CM Slow FM:
CM Servo setting:
- In1 Gain 31dB, SW:OFF, Offset -1.880, Boost Off, Super Boost Off, AO +8dB
MC Servo setting:
Acquisition:
- Engage LSC
- LSC MC servo gain +0.1, FM7/FM10 (Trigger FM2 with 3sec delay)
- Turn on MC
Transition:
- Enable AO path (CM servo In1 SW:ON, MC servo In2 SW:ON)
- LSC MC gain +0.1 -> +0.2
- AO path gain 8dB->14dB
- LSC MC gain +0.2 -> +0.35
- AO path gain 14dB->18dB
- CM servo offset
-1.88 -2.7 -> 0.8 0.0 (gradually)
- Enable CM servo Boost
Lock acquisition path 2
Initial condition:
CM Slow FM:
CM Servo setting:
- In1 Gain 31dB, SW:OFF, Offset -1.880, Boost Off, Super Boost Off, AO +20dB
MC Servo setting:
Acquisition:
- Engage LSC
- LSC Yarm G=+0.25 FM4/5 (Trigger FM3/6/7/8)
Transition:
- Enable MC servo In2 (SW:ON)
- Set LSC MC gain +0.2 FM7/10
- Enable LSC MC (On)
- Enable CM servo In1 (SW:ON)
- Disable LSC Yarm (OFF)
- Change CM servo offset
-1.88 -> +0.700 -2.70 -> 0.0
- Enable CM servo Boost
- Turn on LSC CM FM2 (optional)
Transition to ETMY LSC to MCL
- After all of the transition: LSC output matrix ETMY (+1.00)
- LSC output matrix MC2 (-1.00)
- LSC output matrix ETMY (0.00)
|