A while ago, I noticed that the most significant bits of the LSC whitening DOs are not toggling.
I track this issue down and found what is happening. I need experts' help.


To illuminate the issue, terminators are connected to Bit15 of the Bit2Word blocks in the LSC model (attached screen shots).

The corresponding source file is found in c1lsc.c at the following location.
The last channels of the Bit2Word are connected to lsc_cm_slow (the filter module).
This is the source of the issue. This wrong assignment of the connections
can't be changed by connecting Go-From tags to the chennels.

/opt/rtcds/caltech/c1/rtbuild/src/fe/c1lsc/c1lsc.c

3881// Bit2Word:  LSC_cdsBit2Word1                                                                                                              
3882{
3883double ins[16] = {
3884        lsc_as110_logicaloperator4,
3885        lsc_as110_logicaloperator1,
3886        lsc_refl11_logicaloperator4,
3887        lsc_refl11_logicaloperator1,
3888        lsc_pox11_logicaloperator4,
3889        lsc_pox11_logicaloperator1,
3890        lsc_poy11_logicaloperator4,
3891        lsc_poy11_logicaloperator1,
3892        lsc_refl33_logicaloperator4,
3893        lsc_refl33_logicaloperator1,
3894        lsc_pop22_logicaloperator4,
3895        lsc_pop22_logicaloperator1,
3896        lsc_pop110_logicaloperator4,
3897        lsc_pop110_logicaloperator1,
3898        lsc_as165_logicaloperator4,
3899        lsc_cm_slow
3900};
3901lsc_cdsbit2word1 = 0;
3902for (ii = 0; ii < 16; ii++)
3903{
3904if (ins[ii]) {
3905lsc_cdsbit2word1 += powers_of_2[ii];
3906}
3907}
3908}

3946// Bit2Word:  LSC_cdsBit2Word2                                                                                                              
3947{                                                                                                                                           
3948double ins[16] = {                                                                                                                          
3949        lsc_as55_logicaloperator4,                                                                                                          
3950        lsc_as55_logicaloperator1,                                                                                                          
3951        lsc_refl55_logicaloperator4,                                                                                                        
3952        lsc_refl55_logicaloperator1,                                                                                                        
3953        lsc_pop55_logicaloperator4,                                                                                                         
3954        lsc_pop55_logicaloperator1,                                                                                                         
3955        lsc_refl165_logicaloperator4,                                                                                                       
3956        lsc_refl165_logicaloperator1,                                                                                                       
3957        lsc_logicaloperator_cm_ctrl,                                                                                                        
3958        ground,                                                                                                                             
3959        ground,                                                                                                                             
3960        lsc_logicaloperator_popdc,                                                                                                          
3961        lsc_logicaloperator_poydc,                                                                                                          
3962        lsc_logicaloperator_poxdc,                                                                                                          
3963        lsc_logicaloperator_refldc,                                                                                                         
3964        lsc_cm_slow                                                                                                                         
3965};                                                                                                                                          
3966lsc_cdsbit2word2 = 0;                                                                                                                       
3967for (ii = 0; ii < 16; ii++)                                                                                                                 
3968{                                                                                                                                           
3969if (ins[ii]) {                                                                                                                              
3970lsc_cdsbit2word2 += powers_of_2[ii];
3971}
3972}
3973}

 