Quote:

Well, let's see how the CM servo can handle this.
The key point here is that we have enough data to start the design of the CM servo.

 It seems to me that current design of the common mode servo is already fine. Attached plots show common mode open and closed loop transfer function.

Frequency response of the servo is taken from the document D040180. I assumed coupled cavity pole to be ~100 Hz.

The only question is if our EOM has enough range. Boost 2 increases noise injection by 10 dB in the frequency range 20-50 kHz. Boost 3 has even higher factor.

Attachment 1: CM_OL.pdf  79 kB  | Hide | Hide all | Show all
CM_OL.pdf
Attachment 2: CM_CL.pdf  86 kB  | Show | Hide all | Show all