Quote: |
1) c1auxex - fixed
Tried telnet c1auxex => rejected by the host
Went down to the south end. Power cycled the target. Came back to the control room.
=> Confirmed the epics read/write is back.
Burtrestored the epics vars for the target to the snapshot on 31th Oct at 5:07.
|
When I came in this morning, in addition to the fb being unhappy [elog 9436] (which Koji later fixed [elog 9437] ), c1auxex was down / not talking to the world nicely.
I tried telnet-ing, but was rejected, so EricQ and I went down to the Xend and pushed the reset button on the computer. The computer came back up just fine, and I did a burt restore to 03:07 on Nov 30th. |