Entry  Mon Dec 2 14:24:10 2013, Steve, Update, CDS, computer problems c1iscex.png1X6.JPG
    Reply  Tue Dec 3 17:08:06 2013, Koji, Update, CDS, computer problems 
       Reply  Wed Dec 4 12:02:39 2013, Koji, Update, CDS, FB restored 
Message ID: 9432     Entry time: Mon Dec 2 14:24:10 2013     Reply to this: 9436
Author: Steve 
Type: Update 
Category: CDS 
Subject: computer problems 

Rack 1x6 is very noisy.

 SunFire X4600 computer: FB (directly below Megatron) has it's yellow warning light on. It must be loosing one of it's  fan bearings.

 

Jetstore's error message: IDE channel #2 reading error