40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Nov 7 14:39:49 2013, Jenne, Update, LSC, Lock Acquisition Game Plan LockAcquisition_7Nov2013.pdf
    Reply  Fri Nov 8 18:12:21 2013, Jenne, Update, LSC, PRFPMI: Not crossing any resonances 2f_resonances_Xarm_CARMsweep.pngAllModFreq_resonances_Xarm_CARMsweep.png
    Reply  Tue Nov 12 16:49:22 2013, Jenne, Update, LSC, Xend QPD and Whitening board pulled IMG_1262.JPGIMG_1260.JPGIMG_1264.JPGIMG_1276.JPG
       Reply  Wed Nov 20 17:05:15 2013, Jenne, Update, LSC, Xend QPD and Whitening board replaced 
       Reply  Wed Dec 18 00:26:15 2013, Jenne, Update, LSC, Xend QPD schematic investigation 
          Reply  Wed Dec 18 11:32:34 2013, rana, Update, LSC, Xend QPD schematic investigation 
    Reply  Wed Nov 13 01:35:40 2013, Jenne, Update, LSC, PRM motion causing trouble? xarmRIN_vs_CARM.pngASportOverlap_moveGaussianBeams.png
       Reply  Wed Nov 13 09:31:15 2013, Gabriele, Update, LSC, PRM motion causing trouble? 
          Reply  Wed Nov 13 19:22:58 2013, Jenne, Update, LSC, PRM motion correlated to intracavity power POPDC_sensors_30oct2013.pngAOMmodulated_POPDC_OSEM.pdf
             Reply  Thu Nov 14 02:50:43 2013, Jenne, Update, LSC, PRM oplev measured and modeled TF PRM_OL_TF_model.pngPRM_OLPIT_TF.pdfPRM_OLYAW_TF.pdf
                Reply  Mon Nov 18 21:02:54 2013, Jenne, Update, LSC, PRM oplev measured and modeled TF PRM_OLG_NewOld.pngPRM_oplev_improvement.pdf
                   Reply  Mon Nov 18 21:40:24 2013, Koji, Update, LSC, PRM oplev measured and modeled TF 
                      Reply  Tue Nov 19 14:47:44 2013, Jenne, Update, LSC, PRM oplev measured and modeled TF 
             Reply  Thu Nov 14 02:55:26 2013, rana, Update, SUS, PRM motion correlated to intracavity power 
                Reply  Thu Nov 14 11:41:19 2013, Steve, Update, SUS, PRM sensors effected by IR IRon_off.png
                   Reply  Thu Nov 14 14:35:12 2013, Steve, Update, SUS, IR effect on MC and PRM sensors MC_PRM_IReffect.png
                      Reply  Fri Dec 6 10:03:07 2013, Steve, Update, SUS, IR effect on MC sensors only 10minPMCnotLocked.png6Dec2013.png
Message ID: 9418     Entry time: Wed Nov 20 17:05:15 2013     In reply to: 9367
Author: Jenne 
Type: Update 
Category: LSC 
Subject: Xend QPD and Whitening board replaced 

[EricQ, Jenne]

We have put the Xend QPD back in place, and centered it.  The whitening board was replaced by me a few days ago.

We also went down to the Yend and centered the Yend QPD.

I used the offset.py script that Masayuki wrote to zero the offsets of the individual quadrants when the PSL shutter was closed, and then I averaged the output of the SUM filter banks, and made the gains 1/AvgSum, so that both the Thorlabs PD and the QPD are normalized to 1 at single-arm resonance, for each arm.

I don't know what the gain is of the QPD head off the top of my head, relative to the Thorlabs PD, but eventually we want them to be the same, so that 1=1 and 700=700 on each PD.