Author: Koji 
Type: Update 
Category: IOO 
Subject: WFS with beam dumps 

Unfortunately this does not work. These WFSs are not the detectors which we can move freely.
In order to move the WFS detectors, we need the precise design of the Gouy phase for each WFS heads.
Without the design, we can't move the detectors.