40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Nov 13 18:02:08 2013, Jenne, Update, CDS, Can't talk to AUXEY? 
    Reply  Thu Nov 14 22:23:22 2013, Jenne, Update, CDS, Can't talk to AUXEY? 
       Reply  Fri Nov 15 10:19:26 2013, manasa, Update, CDS, Can't talk to AUXEY? 
          Reply  Fri Nov 15 10:49:55 2013, jamie, Update, CDS, Can't talk to AUXEY? 
             Reply  Fri Nov 15 12:00:28 2013, Koji, Update, CDS, Can't talk to AUXEY? 
             Reply  Fri Nov 15 12:38:50 2013, Jenne, Update, CDS, Can't talk to AUXEY? 
                Reply  Fri Nov 15 13:26:00 2013, Jenne, Update, CDS, AUXEY is back 
    Reply  Mon Nov 18 21:20:54 2013, Jenne, Update, CDS, Can't talk to AUXEY? 
       Reply  Tue Nov 19 15:04:14 2013, Jenne, Update, CDS, Can talk to AUXEY again 
Message ID: 9375     Entry time: Wed Nov 13 18:02:08 2013     Reply to this: 9387   9402
Author: Jenne 
Type: Update 
Category: CDS 
Subject: Can't talk to AUXEY? 

The restore scripts from the IFO config screen half-failed, with this error:

retrying (1/5)...
retrying (2/5)...
CA.Client.Exception...............................................
    Warning: "Virtual circuit disconnect"
    Context: "c1auxey.martian:5064"
    Source File: ../cac.cpp line 1214
    Current Time: Wed Nov 13 2013 17:24:00.389261330
..................................................................

Jamie, do you know what this might be?  When requested, ETMY was not misaligned or restored, but we got these errors.  So, somehow we're not talking properly to EY, but other things seem fine (the models are running okay, the suspension is damped, etc, etc.)