40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Nov 5 16:47:19 2013, rana, Frogs, LSC, illegal power supply about to expire 20131023_222351.jpg
    Reply  Tue Nov 5 17:12:48 2013, Jenne, Frogs, LSC, illegal power supply about to expire 
    Reply  Wed Nov 6 14:47:41 2013, Steve, Frogs, LSC, Din connectors added at 1Y2 1Y2moreDinFuses.jpg
       Reply  Wed Nov 6 15:57:22 2013, Jenne, Update, LSC, Power Supply solution 
          Reply  Fri Nov 8 17:19:27 2013, Jenne, Update, LSC, New Broadband PD for POP 22/110 IMG_1255.JPG
             Reply  Sat Nov 9 10:25:43 2013, Koji, Update, LSC, New Broadband PD for POP 22/110 
                Reply  Tue Dec 17 14:06:59 2013, rana, Update, LSC, New Broadband PD for POP 22/110 POP22110sch.pdfPOP22110.pdf
    Reply  Thu Feb 26 16:37:21 2015, manasa, Frogs, LSC, RIP illegal power supply 
Message ID: 9355     Entry time: Wed Nov 6 15:57:22 2013     In reply to: 9353     Reply to this: 9361
Author: Jenne 
Type: Update 
Category: LSC 
Subject: Power Supply solution 

We have decided that, rather than replacing the power source for the amplifiers that are on the rack, and leaving the Thorlabs PD as POP22/110, we will remove all of the temporary elements, and put in something more permanent.

So, I have taken the broadband PDs from Zach's Gyro experiment in the ATF.  We will figure out what needs to be done to modify these to notch out unwanted frequencies, and amplify the signal nicely.  We will also create a pair of cables - one for power from the LSC rack, and one for signal back to the LSC rack.  Then we'll swap out the currently installed Thorlabs PD and replace it with a broadband PD.