Entry  Sat Nov 2 19:36:15 2013, Charles, Update, General, Possible misalignment? 
    Reply  Mon Nov 4 09:03:21 2013, Steve, Update, PSL, PMC auto locker  3dTREND.png
Message ID: 9333     Entry time: Mon Nov 4 09:03:21 2013     In reply to: 9330
Author: Steve 
Type: Update 
Category: PSL 
Subject: PMC auto locker  

Quote:

 I was working on the electronics bench and what sounded like a huge truck rolled by outside. I didn't notice anything until now, but It looks like something became misaligned when the truck passed by (~6:45-6:50 pm). I can hear a lot of noise coming out of the control room speakers and pretty much all of the IOO plots on the wall have sharp discontinuities.

I haven't been moving around much for the past 2 hours so I don't think it was me, but I thought it was worth noting.

 The PMC auto locker is not set to acquire error message made me lock PMC manually.  Arms  locked instantly: TRY 0.9 V and TRX 0.65 V