Message ID: 9333
Entry time: Mon Nov 4 09:03:21 2013
In reply to: 9330
|
Author: |
Steve |
Type: |
Update |
Category: |
PSL |
Subject: |
PMC auto locker |
|
|
Quote: |
I was working on the electronics bench and what sounded like a huge truck rolled by outside. I didn't notice anything until now, but It looks like something became misaligned when the truck passed by (~6:45-6:50 pm). I can hear a lot of noise coming out of the control room speakers and pretty much all of the IOO plots on the wall have sharp discontinuities.
I haven't been moving around much for the past 2 hours so I don't think it was me, but I thought it was worth noting.
|
The PMC auto locker is not set to acquire error message made me lock PMC manually. Arms locked instantly: TRY 0.9 V and TRX 0.65 V |
|
|