Message ID: 9166     Entry time: Thu Sep 26 21:55:08 2013     In reply to: 9165
Author: rana 
Type: Update 
Category: SUS 
Subject: Problems with ETMY Optical Lever 

Not so fast! We need to plan ahead of time so that we don't have to repeat this ETMY layout another dozen times. Please don't make any changes yet to the OL layout.

Its not enough to change the optics if we don't retune the loop. Please do buy a couple of JDSU (and then we need to measure their intensity noise as you did before) and the 633 nm optics for the mode matching and then we can plan about the layout.