Entry  Tue Sep 17 18:44:29 2013, Masayuki, Update, LSC, LSC calibration screen calibration_screen.png
    Reply  Fri Sep 20 22:49:10 2013, Masayuki, Update, LSC, LSC calibration screen plot.pdf
       Reply  Wed Sep 25 08:11:01 2013, Masayuki, Summary, LSC, LSC calibration screen plot.pdfScreenshot.pngScreenshot-1.pngfringe.pdf
          Reply  Fri Sep 27 13:55:11 2013, Masayuki, Update, LSC, LSC calibration screen 
             Reply  Fri Sep 27 21:01:50 2013, Masayuki, Update, LSC, LSC calibration screen 
                Reply  Mon Sep 30 11:33:15 2013, rana, Update, LSC, LSC calibration screen 
Message ID: 9136     Entry time: Tue Sep 17 18:44:29 2013     Reply to this: 9149
Author: Masayuki 
Type: Update 
Category: LSC 
Subject: LSC calibration screen 

I update the LSC calibration screen. This screen is for real time calibration of each DOF with using error signal and control signal. The formula of the calibration is

x_dis = V_err/H + A V_fb

,where x_dis is the disturbance without surpression, V_err and V_fb are error signal and control signal, H is the transfer function from the displacement to output and A is the efficiency of the actuator.

I will put the filter of 1/H into the CINV filter bank and actuator efficiency into the A filter bank.

 

Attachment 1: calibration_screen.png  12 kB  | Show | Show all