40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Apr 3 17:40:18 2013, Jamie, Configuration, Electronics, putting together a 110 MHz LSC demod board 
    Reply  Wed Apr 3 18:41:22 2013, Jamie, Configuration, Electronics, putting together a 110 MHz LSC demod board 
    Reply  Wed Apr 3 22:26:51 2013, rana, Configuration, Electronics, putting together a 110 MHz LSC demod board 
       Reply  Thu Apr 4 14:37:15 2013, Jamie, Configuration, Electronics, putting together a 110 MHz LSC demod board 
          Reply  Mon Aug 26 18:55:18 2013, Jenne, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS AS110_demod_board_modifications.pdf
             Reply  Mon Aug 26 20:13:17 2013, rana, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS 
                Reply  Tue Aug 27 15:31:48 2013, Jenne, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS 
                   Reply  Tue Sep 3 21:10:36 2013, Jenne, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS 
             Reply  Tue Aug 27 17:32:52 2013, Jenne, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS 
                Reply  Tue Aug 27 18:21:35 2013, Jenne, Configuration, Electronics, 110 MHz LO options 
                   Reply  Tue Aug 27 18:58:52 2013, Koji, Configuration, Electronics, 110 MHz LO options 
                   Reply  Mon Sep 2 16:46:32 2013, Jenne, Update, Electronics, RF distribution box is on the bench 
                      Reply  Mon Sep 2 18:06:21 2013, Jenne, Update, Electronics, RF distribution box: 110 MHz LO options RF_distribution_box_proposed_modifications.pdf0902131751.jpg0902131751a.jpg
                         Reply  Tue Sep 3 21:08:13 2013, Jenne, Update, Electronics, RF distribution box: 110 MHz LO options 
                            Reply  Wed Sep 4 16:06:40 2013, Jenne, Update, Electronics, RF distribution box: Reinstalled 
                               Reply  Wed Sep 4 21:44:54 2013, Not Jenne, Update, Electronics, RF distribution box: Reinstalled 
Message ID: 9106     Entry time: Wed Sep 4 21:44:54 2013     In reply to: 9101
Author: Not Jenne 
Type: Update 
Category: Electronics 
Subject: RF distribution box: Reinstalled 

Temporary fix for the switch: give a bit of oil to the button

Permanent fix: buy better switches.

ELOG V3.1.3-