Entry  Wed Sep 4 16:08:22 2013, manasa, Update, SUS, MC2 tickler turned OFF 
    Reply  Wed Sep 4 20:39:23 2013, rana, Update, SUS, MC2 tickler turned OFF 
       Reply  Wed Sep 4 22:14:35 2013, Jenne, Update, SUS, MC2 tickler turned OFF 
          Reply  Thu Sep 5 00:40:33 2013, rana, Update, SUS, MC2 tickler turned OFF 
Message ID: 9102     Entry time: Wed Sep 4 16:08:22 2013     Reply to this: 9104
Author: manasa 
Type: Update 
Category: SUS 
Subject: MC2 tickler turned OFF 

 [Jenne, Manasa]

While we were trying to relock the MC after Jenne put back the RF box, we found there was some mysterious motion in MC2. After spending time trying to figure out where this was coming from, the source was found to be at LOCKIN2 of MC2 suspension "The MC TICKLERthat was left enabled. This was turned OFF and MC locked just fine after that.

 

EDIT JCD:  The Tickler should be disabled, if the autolocker is disabled.