40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Apr 3 17:40:18 2013, Jamie, Configuration, Electronics, putting together a 110 MHz LSC demod board 
    Reply  Wed Apr 3 18:41:22 2013, Jamie, Configuration, Electronics, putting together a 110 MHz LSC demod board 
    Reply  Wed Apr 3 22:26:51 2013, rana, Configuration, Electronics, putting together a 110 MHz LSC demod board 
       Reply  Thu Apr 4 14:37:15 2013, Jamie, Configuration, Electronics, putting together a 110 MHz LSC demod board 
          Reply  Mon Aug 26 18:55:18 2013, Jenne, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS AS110_demod_board_modifications.pdf
             Reply  Mon Aug 26 20:13:17 2013, rana, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS 
                Reply  Tue Aug 27 15:31:48 2013, Jenne, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS 
                   Reply  Tue Sep 3 21:10:36 2013, Jenne, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS 
             Reply  Tue Aug 27 17:32:52 2013, Jenne, Configuration, Electronics, putting together a 110 MHz LSC demod board for AS 
                Reply  Tue Aug 27 18:21:35 2013, Jenne, Configuration, Electronics, 110 MHz LO options 
                   Reply  Tue Aug 27 18:58:52 2013, Koji, Configuration, Electronics, 110 MHz LO options 
                   Reply  Mon Sep 2 16:46:32 2013, Jenne, Update, Electronics, RF distribution box is on the bench 
                      Reply  Mon Sep 2 18:06:21 2013, Jenne, Update, Electronics, RF distribution box: 110 MHz LO options RF_distribution_box_proposed_modifications.pdf0902131751.jpg0902131751a.jpg
                         Reply  Tue Sep 3 21:08:13 2013, Jenne, Update, Electronics, RF distribution box: 110 MHz LO options 
                            Reply  Wed Sep 4 16:06:40 2013, Jenne, Update, Electronics, RF distribution box: Reinstalled 
                               Reply  Wed Sep 4 21:44:54 2013, Not Jenne, Update, Electronics, RF distribution box: Reinstalled 
Message ID: 9095     Entry time: Mon Sep 2 16:46:32 2013     In reply to: 9072     Reply to this: 9096
Author: Jenne 
Type: Update 
Category: Electronics 
Subject: RF distribution box is on the bench 

I have pulled the RF distribution box out of the rack, so I can look at it, and modify it to have 2 110 MHz spigots. I'm going to make the mods as in elog 9072.

Before I pulled the distribution box, I turned off the RF Generation Box, so don't be surprised that the MC will not lock.  I have terminated the cables that bring the 11 and 55 MHz signals from the generation box to the distribution box, so if someone does turn on the generation box, there won't be bad reflections.

To get the box out, in addition to unplugging all of the cables that go to the distribution box, I had to disconnect 2 of the ADC ribbon cables from the top row of RFPD demod / whitening / ADC boards, since they were in the way.  Everything is labeled, so it should be easy to put back together.

Note to Future Jenne:  Past Jenne put the screws needed for those ADC cables and to hold the box in the rack, in the plastic box that is on the floor in front of the LSC rack. 

Also, I measured the 110 MHz port before I pulled the board, so I would know what my "before" looked like.  I was using the 300MHz 'scope's measurement functions, so these are in volts, not dBm.  Amplitude = 1.33V, RMS = 456 mV, freq = 109.4-111.9 MHz

ELOG V3.1.3-