Entry  Thu Aug 22 21:16:47 2013, Manasa, Update, Green Locking, GTRY normalized 
    Reply  Thu Aug 22 22:05:36 2013, rana, Update, Green Locking, GTRY normalized 
Message ID: 9056     Entry time: Thu Aug 22 22:05:36 2013     In reply to: 9055
Author: rana 
Type: Update 
Category: Green Locking 
Subject: GTRY normalized 

Meh. 600 counts is too weak.  You should fix the electronics so that the maximized green laser transmission gives more like ~10000 counts.