Message ID: 900     Entry time: Fri Aug 29 12:43:44 2008
Author: josephb 
Type: Summary 
Category: Computers 
Subject: c1susvme1 down 
Around noon today, c1susvme was having problems. The C0DAQ_RFMNETWORK light was red. The status light was off, the sig det light was amber and the own data light was green. I could also ssh in, but could not not run startup. I switched off the watchdogs for c1susvme2 (the watchdogs for c1susvme1 had already been tripped), and manually power cycled the crate.

However, when c1susvme1 when it came back up it had not mounted the usual cvs/cds/ directories. c1susvme2 did however. c1susvme1 has been on the new network for awhile, while c1susvme2 was switch over today. So apparently switching networks doesn't help this particular problem.

I did a remote reboot of c1susvme1, and it came up with the correct files mounted. Both machines ran their approriate startup.cmd files and are currently green.