40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Aug 7 15:32:37 2013, Koji, Update, ASC, ASS setting up accelerated (slightly) 
    Reply  Wed Aug 7 19:16:20 2013, Jenne, Update, ASC, ASS setting up accelerated more 
       Reply  Wed Aug 7 22:18:43 2013, Koji, Update, ASC, ASS update Screenshot-Untitled_Window.png
Message ID: 8982     Entry time: Wed Aug 7 22:18:43 2013     In reply to: 8980
Author: Koji 
Type: Update 
Category: ASC 
Subject: ASS update 

While Gautam is working on the Xarm green ASS...

The EPICS monitor points for the ASS actuators were added to the ASS model.

This will be used for the offloading the ASS actuations to the alignment biases.
As this modification allowed us to monitor the actuation apart from the dithering,
now we can migrate the ASS actuation to the fast alignment offset on the suspension.
This modification to the offset moving scripts were also done.

Screenshot-Untitled_Window.png

ELOG V3.1.3-