Entry  Thu Aug 1 22:58:45 2013, Charles, Update, ISS, CTN Servo - Explicit Requirement and Proposed Servo CTN_Servo_TF_-_Proposed_v_Req.pngCTNServo_v3.fil
    Reply  Mon Aug 5 11:53:45 2013, Evan, Update, ISS, CTN Servo - Explicit Requirement and Proposed Servo 
Message ID: 8964     Entry time: Mon Aug 5 11:53:45 2013     In reply to: 8959
Author: Evan 
Type: Update 
Category: ISS 
Subject: CTN Servo - Explicit Requirement and Proposed Servo 

I goofed on the transfer function requirement by not giving you the plant transfer function, which looks to be about 0.014 V/V, independent of frequency (PSL:1278). This needs to be compensated for in the electronic transfer function.