40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Aug 1 12:12:35 2013, gautam, Update, CDS, New model for endtable PZTs
|
Thu Aug 1 13:09:17 2013, gautam, Update, CDS, New model for endtable PZTs-procedure
|
Thu Aug 1 15:06:59 2013, jamie, Update, CDS, New model for endtable PZTs
|
Thu Aug 1 15:28:44 2013, gautam, Update, CDS, New model for endtable PZTs-problem solved
|
Thu Aug 1 20:58:56 2013, gautam, Update, CDS, New model for endtable PZTs-MEDM Screens setup   
|
Mon Aug 5 18:18:32 2013, gautam, Update, CDS, Choosing LO Amplitudes and Frequencies
|
Mon Aug 5 19:10:01 2013, Koji, Update, CDS, Choosing LO Amplitudes and Frequencies
|
Tue Aug 6 16:36:51 2013, gautam, Update, CDS, Choosing LO Amplitudes and Frequencies-revised
|
Wed Aug 7 23:40:49 2013, gautam, Update, CDS, X-End Green ASS - A first update
|
Sat Aug 10 05:53:51 2013, gautam, Update, CDS, X-End Green ASS - Roundup
|
Mon Aug 12 12:57:59 2013, Jenne, Update, CDS, X-End Green ASS - Roundup
|
Mon Aug 12 13:30:33 2013, Jamie, Update, CDS, X-End Green ASS - Roundup
|
|
Message ID: 8952
Entry time: Thu Aug 1 15:28:44 2013
In reply to: 8951
|
Author: |
gautam |
Type: |
Update |
Category: |
CDS |
Subject: |
New model for endtable PZTs-problem solved |
|
|
Quote: |
I don't know what's going on here (why the channels are white), and I don't yet have a suggestion of where to look to fix it but...
Is there a reason that you're making a new model for this? You could just use and existing model at c1iscex, like the c1scx, and put your stuff in a top-names block. Then you wouldn't have to worry about all of the issues with adding and integrating a new model.
|
Koji just fixed this.
It seems that the new model's channels were not automatically added to the master file in the framebuilder (/opt/rtcds/caltech/c1/target/master). Adding the following two lines to the master file fixed the problem;
/opt/rtcds/caltech/c1/chans/daq/C1ASX.ini
/opt/rtcds/caltech/c1/target/gds/param/tpchn_c1asx.par
The box is now green. It looks like C1ASX.ini is created automatically in /opt/rtcds/caltech/c1/chans but the master file needs to be manually edited. The channels are now showing up on dataviewer etc. I have updated the information on the wiki page.
|