40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Aug 1 12:12:35 2013, gautam, Update, CDS, New model for endtable PZTs C1ASX_GDS_TP.png
    Reply  Thu Aug 1 13:09:17 2013, gautam, Update, CDS, New model for endtable PZTs-procedure 
    Reply  Thu Aug 1 15:06:59 2013, jamie, Update, CDS, New model for endtable PZTs 
       Reply  Thu Aug 1 15:28:44 2013, gautam, Update, CDS, New model for endtable PZTs-problem solved 
    Reply  Thu Aug 1 20:58:56 2013, gautam, Update, CDS, New model for endtable PZTs-MEDM Screens setup MAIN_SCREEN.pdfMATRICES.pdfLOCKINS.pdfCONTROL_FILTERS.pdf
       Reply  Mon Aug 5 18:18:32 2013, gautam, Update, CDS, Choosing LO Amplitudes and Frequencies  GTR_Power_Spectrum.pdf
          Reply  Mon Aug 5 19:10:01 2013, Koji, Update, CDS, Choosing LO Amplitudes and Frequencies  
             Reply  Tue Aug 6 16:36:51 2013, gautam, Update, CDS, Choosing LO Amplitudes and Frequencies-revised powerSpec0806.pdf
                Reply  Wed Aug 7 23:40:49 2013, gautam, Update, CDS, X-End Green ASS - A first update time-series.pdf
                   Reply  Sat Aug 10 05:53:51 2013, gautam, Update, CDS, X-End Green ASS - Roundup New_ASX_MEDM_MAIN.pdf
                      Reply  Mon Aug 12 12:57:59 2013, Jenne, Update, CDS, X-End Green ASS - Roundup 
                         Reply  Mon Aug 12 13:30:33 2013, Jamie, Update, CDS, X-End Green ASS - Roundup 
Message ID: 8951     Entry time: Thu Aug 1 15:06:59 2013     In reply to: 8949     Reply to this: 8952
Author: jamie 
Type: Update 
Category: CDS 
Subject: New model for endtable PZTs 

Quote:

I have made a new model for the endtable PZT servo, and have put it in c1iscex. Model name is c1asx. Yesterday, Koji helped me start the model up. The model seems to be running fine now (there were some problems initially, I will post a more detailed elog about this in a bit) but some channels, which are computer generated, don't seem to exist (they show up as white blocks on the MEDM GDS_TP screen). I am attaching a screenshot of the said screen and the names of the channels. More detailed elog about what was done in making the model to follow.

 

C1ASX_GDS_TP.png

 

Channel Names:

C1:DAQ-DC0_C1ASX_STATUS (this is the channel name for the two leftmost white blocks)

C1:DAQ_DC0_C1ASX_CRC_CPS

C1:DAQ-DC0_C1ASX_CRC_SUM

I don't know what's going on here (why the channels are white), and I don't yet have a suggestion of where to look to fix it but...

Is there a reason that you're making a new model for this?  You could just use and existing model at c1iscex, like the c1scx, and put your stuff in a top-names block.  Then you wouldn't have to worry about all of the issues with adding and integrating a new model.

ELOG V3.1.3-