Message ID: 8896     Entry time: Tue Jul 23 00:51:46 2013     In reply to: 8892     Reply to this: 8910
Author: Koji 
Type: Update 
Category: endtable upgrade 
Subject: End table picture 

The spot on the IPANG QPD was checked. The spot is higher than the center and South side of the lens.
Some photos are found below.

The spot on the IPANG steering mirrors in the ETMY chamber was also checked.
It is clipped at the top of the steering mirror. (See attachment 4)
So basically the spot is about 1" above the center of the mirror.

Attachment 1: P7224222.JPG  439 kB  | Hide | Hide all
P7224222.JPG
Attachment 2: P7224223.JPG  418 kB  | Hide | Hide all
P7224223.JPG
Attachment 3: P7224224.JPG  449 kB  | Hide | Hide all
P7224224.JPG
Attachment 4: P7224238.JPG  329 kB  | Hide | Hide all
P7224238.JPG
ELOG V3.1.3-